CS Paper Radar

Optimization of a Hybrid Solar-Biogas-Battery Energy Storage Microgrid: A Case Study

John Elomunait, Jesse Thornburg

eess.SY econ.GN ·submitted 2026-11-25 01:09 UTC · v1
published

Abstract

Low-income regions like eastern Uganda often lack reliable grid power. This paper presents the techno-economic optimization of the Soroti Integrated Renewable Energy Microgrid (SIREM), a hybrid renewable system for grid-access expansion where Soroti District household grid access stands at 16.7\%. The microgrid integrates concentrating solar power (CSP) with thermal storage, biogas combined cycle generation, and lithium iron phosphate battery storage. Using Xendee optimization software with six years of NASA POWER data, the optimal configuration comprises a 37 MW CSP field, 70 MWh molten-salt storage, a 5 MW CSP turbine, a 6 MW biogas CCGT, and a 10 MWh battery system. The design delivers 61.3 GWh annually with a 42.91% IRR, 2-year payback, and levelized cost of electricity of 0.1991 USD/kWh generation (0.3752 USD/kWh load-served), achieving 32.2% total savings versus grid-only supply while exporting 28.8 GWh annually, demonstrating the viability of hybrid renewable microgrids for grid expansion in sub-Saharan Africa.

Comment
6 pages, 6 figures, presented at IEEE PES/IAS PowerAfrica Conference 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Optimization of a Solar-Grid Water Supply System with Hydraulic Energy Storage: A Case Study

eess.SY econ.GN ·2026-11-23 ·Mariamawit Gashahun Arega, Jesse Thornburg
published similarity 0.67
Abstract · 6 pages, 3 figures, presented at 2026 IEEE PES/IAS PowerAfrica Conference

Given the high cost of grid-scale batteries, other energy storage approaches are needed for developing and low-income regions. Elevated volumes of water are often more economically feasible energy storage options than batteries in these contexts. This paper presents a dual-framework modeling approach for one such energy storage setup: a solar-grid hybrid water supply system in the arid Afar region of Ethiopia. By utilizing an elevated 1,900 m3 water reservoir as a "hydraulic battery," the system replaces traditional electrochemical storage, significantly reducing capital expenditures. Using Python for high-resolution technical simulation and Xendee for economic optimization, the study shows a 55.1% solar fraction and a 10% Internal Rate of Return (IRR). The results confirm that hybrid systems with hydraulic storage offer a financially viable and reliable solution for water access in energy-constrained regions.

0.27

Co-Optimized Generation, Transmission, and Storage Expansion: System Value and Optimal Duration of Pumped-Storage Hydropower

eess.SY math.OC ·2026-08-27 ·Rafael Benchimol Klausner, Rafael Kelman
similarity 0.59
Abstract

Expansion planning models usually fix storage duration before optimization, setting how much storage power to build but not for how long it can discharge. We present a generation-transmission-storage expansion framework in which candidates of many durations compete on annualized cost, making the duration mix an optimization outcome. It is a rolling-horizon, two-stage stochastic linear program, each five-year stage is a full year at hourly resolution under ten coherent inflow, wind, and solar scenarios. We apply it to the Brazilian Interconnected System over 2030-2050, where demand roughly doubles to 1,716 TWh/year and variable renewable energy (VRE) supplies most new capacity. Two cases are compared: 36 pumped-storage hydropower (PSH) candidates over four subsystems and nine durations (4-144 h) alongside 4-h battery energy storage systems (BESS), and BESS alone. With PSH available, the model builds 31.2 GW / 755 GWh of PSH and no BESS, dominated by 12-h capacity with 4.9 GW of 72-h units. Without PSH it builds 38 GW / 152 GWh of BESS and 7.8 GW more gas-fired capacity, mostly open-cycle peakers. PSH lowers 2050 annualized system cost by US$ 5.0 billion/year (6.8%), operating cost by 23.5%, thermal generation by 34 TWh/year, and long-run marginal cost by 20%; 2035 VRE curtailment falls from 8.4% to 3.2%. The magnitudes are specific to Brazil, but the underlying mechanism is general: limiting storage candidates to a single duration understates the system's optimal energy-storage requirement and overstates its residual need for thermal capacity.

0.30

Optimal Power Sharing for Hybrid Energy Storage Systems Based on Karush-Kuhn-Tucker Conditions

eess.SY ·2026-09-25 ·Juan Diego Rios-Peñaloza, Milan Prodanovic, Javier Roldán-Pérez
similarity 0.58
Abstract · Submitted to a scientific journal for possible publication. 10 pages, 15 figures

Renewable energy power plants are increasingly expected to provide ancillary services to the grid. Yet, the variability of sources such as solar photovoltaics requires additional operational flexibility to deliver these services. In this context, hybrid energy storage systems (HESSs) offer an appropriate solution, because different technologies with complementary characteristics can be applied and leveraged to share the power demand and improve the overall performance. Yet, a proper power sharing requires a detailed model of the storage elements. This aspect has barely been studied in the literature, where most models consider constant efficiencies. Moreover, most formulations are based on optimisation problems that are computationally too demanding to be solved in real time. In this paper, a controller is proposed to minimise the losses of a HESS considering detailed power-dependent efficiency curves of each storage technology. The power sharing method is based on the analytical verification of the Karush-Kuhn-Tucker (KKT) conditions, which makes it computationally efficient and suitable for real-world deployment. The proposed controller is applied to a test case consisting of a 10 MW PV power plant with a HESS based on a lithium-ion battery and a redox-flow battery, each with 2.5 MW power and 5 MWh capacity. The main contributions are verified via numerical simulations performed in MATLAB/Simulink, whereas a real-time implementation deployed in OPAL-RT demonstrates the viability of the algorithm for real-time applications.

0.29

PyPSA-Libya: An Open-Source Energy System Model for National Decarbonization and Hydrogen Export Pathways

cs.CE eess.SY ·2026-10-28 ·Mohamed Abuella
code/data similarity 0.57
Abstract · 36 pages, 15 figures, 10 tables

Libya possesses significant renewable energy potential that remains largely untapped. This paper presents PyPSA-Libya, a national-scale model built on the PyPSA-Earth framework, designed to explore optimal transition pathways for the Libyan power sector. We present two primary studies: (1) an electricity-only capacity expansion analysis comparing a zero-emission constraint against an unconstrained baseline at 36-cluster resolution, and (2) a sector-coupled hydrogen export study evaluating the levelized cost of exporting 70 TWh/year of hydrogen to Europe under three technological scenarios and a 100 EUR/tonne CO2 carbon tax regime. Results indicate that while solar PV dominates the domestic capacity mix, integration of hydrogen production significantly alters grid storage requirements. Furthermore, under carbon pricing, steam methane reforming with carbon capture (SMR-CC) frequently out-competes pure green electrolysis, establishing a lower-cost compliance pathway for cross-border export. The model, data, and configuration files are released under an open-source license to support transparent energy planning in Libya.

0.34

Review on State-of-the-art Energy Systems in the Arctic

eess.SY ·2026-09-09 ·Bilal Babar, Sabrina Sartori
similarity 0.54
Abstract · 35 pages, 6 figures and 6 tables, preprint, title updated

The Arctic regions remain heavily dependent on fossil fuels for energy generation. At the same time, the Arctic is warming at a rate considerably faster than the global average, increasing the need for low-carbon and climate-resilient energy systems. This review documents the current energy systems and assesses state-of-the-art energy solutions applicable to Arctic and cold-climate regions, as well as the future direction of these emerging energy systems, and analyses the role of energy storage, heating requirements, and advanced energy solutions. A total of 88 research articles were systematically reviewed. The reviewed studies indicate the potential for wind and solar to reduce dependence on fossil-fuel based energy generation. For energy storage, the reviewed solutions include hydrogen for long-term storage, battery-based system for short-term storage and regulation, and thermal storage using boreholes to meet heating demand. Where a fully renewable system cannot provide the required reliability, diesel can serve as back up generation. Some barriers to widespread adoption are technological, such as the need for specialized planning tools and equipment resilient to harsh weather, and social and institutional, such as the need for governmental support, subsidies, and appropriate legal frameworks.

0.29

Resilient Design and Optimal Operation of Battery Energy Storage Systems for Behind-the-Meter Data Center Microgrids

eess.SY ·2026-09-16 ·Hamed Haggi, Chinmay Morankar
similarity 0.54
Abstract · Under Review

This paper proposes a high-fidelity hyperscale data center load modeling framework that disaggregates facility demand into IT and non-IT components and represents load behavior at second- and minute-level resolutions. Building upon this foundation, a comprehensive multi-phase optimization framework is developed for the planning and resilient design of BESS for BTM data center microgrids. The framework deploys BESS on the load side to act as a dynamic buffer between stochastic demand and generation assets. By smoothing the load spikes and excursions before they are observed by gas turbines, the load-side BESS reduces operational stress and limits conditions that can contribute to SSTI issues, shaft fatigue, system trips, equipment damage, and forced outages. Simultaneously, generation-side BESS resources are optimally sized to provide spinning reserves and enhance system resilience. The proposed methodology co-optimizes BESS with solar, wind, natural gas fuel cells, simple-cycle gas turbines, and combined-cycle gas turbines while incorporating operational, reliability, resiliency, and technology-specific constraints. Simulation results demonstrate the proposed methodology's ability to identify cost-effective, resilient, and operationally feasible designs that satisfy the demanding reliability requirements and energy market challenges of next-generation hyperscale data centers while providing planning insights for investors, developers, and system operators.

0.19

Optimizing Multi-Market Participation of Battery and Electrolyser Systems Based on Field Performance

cs.LG ·2026-08-17 ·Chunyang Zhao, Stoyan Trenchev, Shi You, Chresten Træholt
published similarity 0.54
Abstract · 6 pages, 8 figures. Accepted at the 2026 IEEE Power and Energy Society General Meeting (PESGM)

The increasing share of renewable energy in power systems creates a need for fast-response and flexible resources to maintain system stability. With the expansion of electricity markets and ancillary service products, opportunities arise to stack revenues across multiple services. Long-term Power-to-X (PTX) electrolysers and short-term battery energy storage systems (BESS) are prevalent flexible resources, yet most studies neglect real hardware behavior, such as ramp limits, efficiency, and setpoint-tracking accuracy. This work presents experimental and modeling results for a 55 kW/79 kWh BESS and an electrolyser comprising three 2.4 kW units. Key characteristics are identified through measurements and embedded into a price-driven optimization framework for participation in the Danish electricity and ancillary service markets, utilizing real market data from 2022 to 2025. The optimized daily profits for multi-market participation are 1,749.27 DKK and 289.46 DKK for the BESS and electrolyser, respectively. With the demonstrated business cases for BESS and PTX systems, this work highlights the importance of incorporating experimental performance when evaluating participation across multiple markets and years.

0.38

Optimal Demand Response-Based Energy Management for Campus Buildings with Battery Energy Storage Systems: A Case Study of the ELB Building

eess.SY ·2026-10-14 ·Ali Beidoun, Quang Manh Hoang, Guilherme Vieira Hollweg, Van-Hai Bui
published similarity 0.53
Abstract · 1-12

Buildings account for a significant portion of global electricity consumption, making demand response (DR) an effective strategy for reducing energy costs and improving grid flexibility. This paper presents an optimal energy management framework for a campus building that integrates demand response and battery energy storage systems (BESS) to minimize electricity costs while satisfying operational constraints and occupant comfort requirements. The proposed optimization model schedules building loads and battery charging/discharging based on time-varying electricity prices and building demand profiles. The framework is validated using the Engineering Laboratory Building (ELB) at the University of Michigan-Dearborn as a real-world case study. Four operating scenarios are investigated: (i) baseline operation, (ii) demand response without battery energy storage, (iii) battery energy storage, and (iv) demand response with battery energy storage. Simulation results demonstrate that demand alone reduces the building's electricity cost by approximately 12% compared with conventional operation. When battery energy storage is incorporated, the total electricity cost reduction increases to approximately 26%, highlighting the significant economic benefits of coordinated demand response and energy storage scheduling. The results demonstrate that integrating battery energy storage with demand response substantially enhances the operational flexibility of campus buildings and provides an effective solution for cost-effective and sustainable building energy management.

0.27