CS Paper Radar

DosePET: An Open-Source Dataset with 2100 Radiation Dose Maps for PET/CT

Eleftherios Tzanis, Antonios Tzortzakakis, Michail E. Klontzas

cs.AI physics.med-ph ·submitted 2026-11-25 08:55 UTC · v1
datasetcode/data

Abstract

Large collections of three-dimensional radiation dose maps linked to patient anatomy are needed to develop artificial intelligence (AI) models for personalized internal dosimetry in nuclear medicine, but access to such data remains limited. Here we present DosePET, an open-source dataset of 2,100 patient-specific absorbed-dose maps generated by Monte Carlo simulation of publicly available PET/CT examinations: 1,503 [18F]FDG examinations from ENHANCE.PET and 369 [18F]PSMA-1007 and 228 [68Ga]Ga-PSMA-11 examinations from PSMA-PET-CT-Lesions, acquired at five institutions with seven scanner models. For each examination, the CT was resampled to the native PET grid to build a voxelized patient phantom, the quantitative PET image defined the radionuclide source, and radiation transport was simulated with GATE version 9.4. Organ and tissue masks were generated from the CT with TotalSegmentator. Each study folder contains a NIfTI dose map integrated from scan time to infinity, 117 binary organ/tissue masks, a report of regional dosimetric quantities, including mean absorbed doses, dose conversion factors and scan-time dose rates, and simulation metadata. The total processing time was 1,542.4 hours. Python tools support selective downloading and conversion to scan-time dose-rate or dose-per-decay maps, and an agent skill guides pairing with the source PET/CT images. DosePET is publicly available at https://huggingface.co/datasets/eltzanis/DosePET.

Comment
9 pages, 2 figures, 2 tables; supplementary material included

Closest papers

Nearest neighbours by meaning across the whole index.

DoseBridge: Denoising Diffusion Bridge Model for Dose Prediction in Lung Intensity-Modulated Proton Therapy

cs.CV ·2026-08-10 ·Zerun Zhang, Xiaoda Cong, Xiangkun Xu, Peter Y. Chen, Xuanfeng Ding
similarity 0.66
Abstract

Most radiotherapy dose-prediction models use only CT images and anatomical structures, although intensity-modulated proton therapy (IMPT) dose also depends strongly on beam geometry and available clinical datasets are often small. We present DoseBridge, a denoising diffusion bridge model that uses the patient CT as a structured bridge endpoint and encodes plan-specific beam geometry in a spatially aligned beam mask. Multiscale fusion combines CT, target, organ-at-risk, and beam-mask representations with 1.95% additional parameters. DoseBridge was retrospectively evaluated on single-institution CT images and treatment plans from 52 patients with advanced-stage lung cancer treated with 60 Gy in 30 fractions; 42 cases were used for training and 10 for testing. Performance was assessed using image-similarity, dose-volume, and Lyman-Kutcher-Burman normal-tissue complication probability (NTCP) metrics and compared with two deep-learning models. On the test cohort, DoseBridge achieved a mean absolute error of 4.170 Gy, peak signal-to-noise ratio of 23.06 dB, and structural similarity index of 0.798, outperforming both comparison models on these metrics. Clinical target volume D95 differed from the reference dose by 0.62 +/- 1.6 Gy; signed organ-at-risk mean-dose differences ranged from -0.32 to 0.24 Gy, and NTCP differences were -0.40 +/- 2.2 and 0.52 +/- 3.4 percentage points for acute esophagitis and radiation pneumonitis, respectively. Changing only the beam mask redirected predicted low-dose entrance regions while preserving the high-dose target region. To our knowledge, DoseBridge is the first denoising diffusion bridge model for radiotherapy dose prediction. These results support its feasibility as a beam-aware planning prior for lung IMPT, pending evaluation in larger external cohorts.

0.04

Generative Priors for Total-Body PET Reconstruction

eess.IV cs.CV ·2026-09-18 ·Movindu Dassanayake, George Webber, Denis Prokopenko, Julia A. Schnabel, Andrew J. Reader
published similarity 0.65
Abstract · MICCAI RIME 2026 (Accepted Poster)

Total-body positron emission tomography (TB-PET) enables fast, low-dose, and dynamic imaging over a long axial field of view, but reconstruction remains challenging due to reduced counts, large image volumes, and increased data dimensionality. Generative models offer powerful learned priors for low-count PET, yet explicit PET measurement conditioning at TB scale has not been demonstrated. Inspired by PET decomposed diffusion sampling (PET-DDS), we propose TB-PET-DDS, a reconstruction framework that combines a CT-conditioned generative prior with patient-specific list-mode PET data. During reverse diffusion, PET consistency is enforced using a closed-form 3D TB-PET maximum-a-posteriori expectation maximisation fusion update, rather than relying solely on image-domain conditioning. The synthetic measurements are generated from the low-dose vendor reconstruction, providing a controlled inverse problem and retaining a full-dose reference. Proof-of-concept evaluation was performed on a single clinical TB-PET acquisition, with reconstruction hyperparameters selected against the full-dose reconstruction from the same case for all models. TB-PET-DDS improved NRMSE and SSIM relative to the DDIM and Image-DDS baselines, improving through-plane consistency in coronal views while enhancing agreement with the measured PET data. Although smoothed low-dose vendor reconstructions achieved the best global voxel-wise metrics, TB-PET-DDS produced the lowest liver coefficient of variation. These results demonstrate the feasibility of measurement conditioned diffusion reconstruction at TB scale and provide an initial route towards learned, projector-consistent generative reconstruction for low-count TB-PET imaging.

0.13

RIQE: a NIQE-style reference model for Computed Tomography

eess.IV cs.CV ·2026-09-30 ·Fabio Mattiussi
code/data similarity 0.60
Abstract · 17 pages, 6 figures, 6 tables. Code and model: https://github.com/Metallogik/RIQE, archived at doi:10.5281/zenodo.23055559

The Natural Image Quality Evaluator (NIQE) scores an image by its statistical distance from a model fitted on pristine images, and its distributed model is fitted on photographs. We release the Radiology Image Quality Evaluator (RIQE), a NIQE-style model fitted on 3,792 full-dose slices from 158 patients of the public LDCT-and-Projection-data collection, with a declared intensity mapping, a manifest of every slice and a script that reproduces the fit. On 40 held-out patients, RIQE ranks reduced-dose reconstructions, simulated by projection-domain noise insertion, worse than the full-dose reconstruction of the same slice in 240 of 240 chest and 230 of 240 abdominal pairs, and ranks images with 20% more noise worse than their source in 97.5-100% of cases. Its preferences among filtered images, however, do not follow lesion signal. With a 4 mm, +10 HU lesion inserted in noisy abdominal slices, RIQE prefers bilateral filtering to the unfiltered image in every image up to a 32 HU residual, at which 29% of the lesion's matched-filter signal remains and its detectability index falls from 0.51 to 0.33; it never prefers Gaussian smoothing, which at the same 32 HU residual leaves 70% of the signal and a detectability index of 0.48. Fitted on photographs with the parameters published for NIQE, the same code ranks every simulated reduced-dose abdominal image better than its full-dose counterpart. RIQE is suited to ranking a degraded image against its source; under the conditions tested it should not be the sole criterion for selecting, comparing or tuning denoisers.

0.56

Efficient 3D Whole-Body PET Image Denoising via Conditional Rectified Flow With Optimized Sampling Strategy

cs.CV ·2026-09-15 ·Jiale Shen, Guolin Wang, Chenhao Wang, Xinhui Su, Wei Luo +1 more
similarity 0.59
Abstract

Reducing radiation exposure in Positron Emission Tomography (PET) is important for patient safety; however, ultra-low-dose imaging suffers from severe noise, which may affect diagnostic interpretation without appropriate image enhancement. While current 3D deep generative models, particularly diffusion models, have shown strong reconstruction fidelity, their practical use can be limited by long inference times. In contrast, faster 2D-based alternatives may have difficulty maintaining volumetric consistency, an important consideration for whole-body PET imaging analysis. To bridge this gap, we propose a one-pass conditional 3D rectified flow (3D Flow) framework for whole-body PET image denoising that incorporates a novel optimized non-uniform sampling strategy. The model is trained with a one-pass linear-interpolant velocity-matching objective. This approach reconstructs a full 3D volume in approximately 30 seconds in our implementation, compared with multi-hour inference for the evaluated 3D DDPM baseline. Evaluations including zero-shot transfer to an independent clinical dataset show that our model achieves favorable global image quality and lesion conspicuity compared with the evaluated 3D DDPM and DDIM baselines, including on challenging short-acquisition data. Furthermore, the proposed method shows promising zero-shot transfer performance across the evaluated datasets and unseen dose levels (down to 1/100 of the standard dose), with artifact-focused visual comparisons supporting the need for further lesion-level validation. By balancing reconstruction fidelity and computational efficiency, this work presents a candidate approach for ultra-low-dose whole-body PET image denoising.

0.08

Personalising Deformable Image Registration with Clinical Context and Deformation History for Adaptive Radiotherapy

eess.IV cs.AI ·2026-10-13 ·Caiwen Jiang, Songlin Zhao, Yuzhen Ding, Jia Mi, Samir H. Patel +21 more
benchmark similarity 0.59
Abstract · 27 pages, 7 figures and 6 tables. The submission includes Supplementary Information

Adaptive radiotherapy must account for anatomical changes during treatment, but doing so depends on reliably mapping targets, organs at risk and dose across serial images. Existing registration methods treat each image pair independently, without using radiotherapy-specific context or the patient's preceding anatomical trajectory. We developed Clinical-context-Aware and Patient-adaptive Deformable Image Registration (CAP-DIR), integrating source contours, dose, clinical text and prior-registration features. We evaluated 16,361 CT examinations from 3,473 patients across four institutional cohorts and five public benchmarks. CAP-DIR increased internal-test organ-at-risk-region normalized cross-correlation from 84.76% to 96.92% relative to the strongest learning-based comparator, with low deformation folding, and remained superior across seven external cohorts. In a blinded review of 20 longitudinal cases, clinically acceptable contours increased from 45.0% to 82.5% for clinical target volumes and from 22.5% to 62.5% for organs at risk, while estimated editing time decreased. In a controlled benchmark, CAP-DIR reduced global dose-mapping error by 34.5% relative to the strongest comparator. These findings show that clinically informed, longitudinal registration can improve contour usability and dose mapping for adaptive radiotherapy.

0.36

Extending TotalSegmentator: Predicting Patient and Acquisition Characteristics from CT and MR Images

cs.AI ·2026-08-29 ·Jakob Wasserthal, Joshy Cyriac, Michael Bach, Kimia Mozahheb Yousefi, Minh-Son To +5 more
code/data similarity 0.59
Abstract

Background: Patient details and acquisition metadata are important for clinical decisions, image quality control, and automated research pipelines, but may be missing or unreliable in imaging archives. Purpose: To develop and evaluate a fast open-source model that predicts patient and acquisition characteristics directly from CT and MR images. Materials and Methods: Separate 3D ResNet-10 ensembles for CT and MR were trained on 57,291 and 43,200 clinical examinations acquired from 2011 to 2025. Both predicted weight, height, age, sex, contrast presence, vertebral coverage, and image noise. The CT model additionally predicted scanner manufacturer, tube voltage, tube current, convolution kernel, and post-injection time; the MR model predicted sequence class. Performance was evaluated on internal CT (n=501) and MR (n=636) test sets and an external CT dataset (n=54). Results: Internal CT MAEs were 3.90 kg, 3.68 cm, and 4.42 years for weight, height, and age, with sex F1=0.990; corresponding MR results were 4.34 kg, 4.62 cm, 7.13 years, and F1=0.970. The CNN outperformed a segmentation-derived XGBoost baseline for all four core targets in both modalities (adjusted P<=.042). F1 scores were 0.963 for CT contrast, 0.953 for MR sequence, and 0.823 for MR contrast. External CT MAEs were 4.45 kg, 4.05 cm, and 5.17 years, with sex F1=0.971. CPU inference required 20 seconds for CT and 12 seconds for MR. Conclusion: One 3D multitask model per modality can rapidly recover patient and acquisition characteristics from heterogeneous CT and MR examinations. Models are available in TotalSegmentator: https://github.com/wasserth/TotalSegmentator

0.43

Domain-Adapted Latent Diffusion Models for CT-to-PET Image Translation

cs.CV ·2026-10-26 ·Yann Bourdé, Lea Bogensperger, Arnela Hadzic, Michael Krauthammer
similarity 0.59
Abstract

Positron Emission Tomography (PET) provides important metabolic information for tumor detection and staging but remains significantly less accessible than Computed Tomography (CT) due to its high cost, infrastructure requirements, and reliance on injected radioactive tracers. CT-to-PET image translation using generative models aims to address this disparity, yet state-of-the-art diffusion-based methods are limited by the scarcity of paired training data. To overcome this, we propose a domain-adapted latent diffusion framework that transfers natural-image priors using a relatively small dataset of 21,930 paired CT/PET slices, incorporating a signed power transform to resolve extreme intensity sparsity in PET data. Compared to CPDM, a state-ofthe-art baseline for CT-to-PET image translation, our approach yields superior performance in pixel-wise reconstruction and localized tumor fidelity, demonstrating effective transfer of natural-image priors to the medical domain. We further provide a systematic analysis of evaluation metric reliability for sparse PET data, showing that standard full-image metrics can be misleading indicators of translated image quality, and propose background-filtered and mask-restricted metrics as more clinically meaningful alternatives.

0.16

Lesion-Aware Adaptive Fourier Neural Operator for CT-to-PSMA PET Synthesis in Prostate Cancer

cs.CV physics.med-ph ·2026-08-11 ·Rashmi Bhaskara, Waleed M. Almutairi, Matthew Gopaulchan, Maram Musaad Alqurashi, Francis Asamoah +3 more
similarity 0.58
Abstract

Deep learning models that synthesize PET from CT or MRI can reduce patient dose and scanner demand, but are typically optimized with global losses such as L1 or mean squared error (MSE) that treat all voxels similarly. In whole-body PSMA-PET, tumor voxels occupy only a small fraction of the volume, yet carry the clinically relevant activity signal; as a result, models can achieve high structural similarity index measure (SSIM) and peak signal-to-noise ratio (PSNR) while still underestimating lesion activity or failing to preserve tumor-specific structure. Radiomics provides biologically meaningful descriptors of tumor intensity and texture, but direct radiomics conditioning is time-consuming because it requires feature extraction from delineated lesion regions. We propose LAFNO, a Lesion-Aware Adaptive Fourier Neural Operator for CT-to-PSMA-PET synthesis that replaces high-dimensional radiomics conditioning with two efficient CT-derived proxy channels. Motivated by radiomics analysis of PSMA-avid tumor core and peritumoral regions, LAFNO uses a contrast proxy for local density variation and a disorder proxy for local texture heterogeneity, both injected into the model bottleneck. LAFNO combines whole-volume reconstruction with lesion-level total lesion activity (TLA), tumor-core contrast, and peritumoral supervision. We evaluated LAFNO against four baseline architectures on the TCIA PSMA-PET-CT-Lesions dataset. LAFNO remained competitive on whole-volume image quality, achieving SSIM of 0.960 and 0.938 for 18F- and 68Ga-PSMA, respectively, while reducing per-patient TLA error to 48.3% and 64.0% for 18F- and 68Ga-PSMA, respectively, and achieving the highest tumor-core radiomics reproducibility across all feature classes for both tracers. Peritumoral reproducibility remained tracer-dependent, indicating that biological fidelity in synthetic PSMA-PET remains challenging.

0.04