CS Paper Radar

Daily listing

2026-11-17 · eess.IV

9 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 9

Gaussian Splatoms: Direct Atomic Structure Identification in Electron Tomography

eess.IV cs.CV ·2026-11-17 ·Nalini Singh, Tiffany Chien, Cedric Lim, Arthur R. C. McCray, Colin Ophus +1 more
Abstract · 26 pages, 14 figures

Atomic electron tomography (AET) computationally reconstructs the 3D atomic structure of materials from a series of 2D projection measurements acquired at different tilt angles. Inspired by Gaussian splatting techniques from computer vision, we introduce an atom-centric parameterization for modeling AET samples. Instead of a conventional volumetric representation with a grid of voxels, we model the sample as a list of atoms, where each atom is a 3D Gaussian characterized by learned location, scale, and amplitude. The Gaussian model is a natural fit for atoms that allows us to easily incorporate prior information grounded in physics; we impose isotropy of atoms, a minimum interatomic distance, and realistic atomic radii. We show in simulation that our method is more robust than volumetric baselines to real-world imaging challenges, including a limited number of measurements and low electron dose. We further show that our method yields a more physically plausible reconstruction of an experimental 23,000 atom iron-platinum nanoparticle than a previously published volumetric reconstruction. Beyond tomography, our representation is a promising tool for any atomic resolution imaging modality (e.g. multislice electron ptychography).

0.33

Streaming Generative Video Compression with Embedding Alignment and In-Context Propagation

eess.IV cs.CVcs.MM ·2026-11-17 ·Zhitao Wang, Hengyu Man, Han Liu, Wenrui Li, Debin Zhao +1 more
code/data
Abstract · 15 pages, 18 figures, 5 tables, including supplementary material

Video compression at ultra-low bitrates presents substantial challenges in preserving perceptual quality. Although pretrained video diffusion transformers (DiTs) provide powerful generative priors, existing generative video compression (GVC) methods built on them typically rely on computationally expensive VAE decoders to reconstruct video frames. Moreover, jointly refining multiple frames to exploit the inherent spatiotemporal modeling capabilities of video DiTs introduces additional buffering delay. To address these challenges, we propose SGVC, a streaming generative video compression framework that adapts a pretrained latent video DiT into a causal pixel-space refiner. Specifically, SGVC projects decoded features from a contextual pixel codec directly into the DiT input embedding space. To bridge the representation gap between codec-derived embeddings and pretrained DiT embeddings, we introduce Embedding Alignment, which aligns the projected embeddings with input embeddings extracted from the original frames during training. The refined DiT hidden states are then mapped directly to the pixel domain through a lightweight reconstruction path, bypassing the pretrained VAE decoder. To further exploit the spatiotemporal priors of the video DiT while maintaining causal decoding, we introduce In-Context Propagation, which reuses layer-wise K/V states across frames to exploit historical generative context, improving temporal consistency without requiring clip-wise buffering. Extensive experiments demonstrate that SGVC achieves competitive rate-perception performance, with average BD-rate savings of 71.97% over S$^2$VC in terms of DISTS. Project Page: https://chigland.github.io/SGVC/

0.29

LIC-Audit: How Comparable Are Reported Gains in Learned Image Compression?

eess.IV cs.CVstat.AP ·2026-11-17 ·Haisheng Fu, Jie Liang, Runyu Yang, Feng Ding, Xin Dong +2 more
benchmark
Abstract · 31 Pages, 4 figures

Learned image compression (LIC) papers often report BD-rate improvements of only a few percent. They are measured against VTM reference software whose version keeps changing: the claims we audit name 7 versions, 5 in 2025 papers alone. But how comparable are these numbers across papers, and what evidence should future papers give for such small gains? We introduce LIC-Audit, an analysis of 353 released rate-distortion curves from 36 repositories, and a controlled re-evaluation of eight public codec releases with 28,193 encode-decode records. We identify three problems. First, different VTM reference runs change BD-rates by up to 3.56 percentage points, and on CLIC Pro published numbers order 10 of 55 method pairs differently from a common computation; comparing codecs directly over a fixed quality range removes this dependence. Second, releases use different and mostly undocumented conventions for counting bits, computing PSNR, and padding images. Under consistent measurement, the GLIC method's 1.00% lead over the HPCM method on Tecnick becomes a 1.43% deficit, changing only the padding reverses the comparison of HPCM and CMIC, and most gaps narrow when MS-SSIM replaces PSNR. Third, average curves hide how much results vary from image to image, so whether a small gain is statistically significant depends on the assumed variation. An optimistic assumption calls 12.0% of comparisons between equally good codecs significant on test sets as small as Kodak, instead of 5%; a cautious one leaves 18 of 45 differences between recent codecs undecided, yet per-image results show 12 of them to be significant. Beyond auditing past results, LIC-Audit provides a versioned evaluation protocol, a public leaderboard website with a scoring tool, source-linked benchmark data, per-image measurements, and reporting guidelines, to help future LIC papers make comparable and verifiable claims of progress.

0.27

Virtual EMI Receiver Generation (VERGE) for Improved EMI Removal in MRI

eess.IV ·2026-11-17 ·Alexander Mertens, Diego Martinez, Amgad Louka, Ying Yang, Chad Harris +1 more
unusual
Abstract

MRI is not designed to operate in the presence of EMI emitting electronic devices. To accomodate this, we propose VERGE which improves on previous EMI removal methods and can operate without external EMI sensors. VERGE estimates a reference coil non-linearly from all imaging and non-imaging coils by training a small per-scan convolutional neural net to generate a virtual coil. The virtual coil is then used with STRIDE, a reference-based EMI removal method. For single-source EMI contamination, VERGE performed similarly to the reference method. For multi-source dynamic EMI contamination, VERGE outperformed the comparison methods. Notably, VERGE with zero physical EMI sensors outperformed the comparison methods even with two physical EMI sensors. A non-linearly estimated virtual EMI coil improves reference-coil-based EMI removal under dynamic multi-source EMI, and enables effective EMI removal without physical EMI sensors or training data.

0.26

MedImgAnnotator: batch wise medical image annotation and preprocessing tool

cs.CV eess.IV ·2026-11-17 ·Ewunate Assaye Kassaw, Amit Mehndiratta, Peush Sahni, Anup Singh
code/data
Abstract

The curation of large cohort datasets for developing deep learning models demands annotating or editing over the AI-predicted labels. However, openly available annotation tools are time-consuming, as they involve complex navigational steps and do not support batch processing. This study aimed to develop a simple, fast, semiautomated batch-annotation tool named MedImgAnnotator. The tool was created by integrating editing tools, image mask pair matching logic, preprocessing functions, object detection tool, and a plugin management system. Its performance was evaluated in terms of active annotation time and ease of use by the developer and 12 users using open-source MR and CT scans. Additionally, the tool had been used by the MICCAI 2026 CARE Challenge liver segmentation best performance winner to annotate liver masks from 6412 MRI volumes. The evaluation results showed that MedImgAnnotator reduced active annotation time from 206.5+/-32.87 (average active annotation time of openly available tools) seconds to 59 seconds. The Wilcoxon signed-rank test of 12 users evaluation results recorded P values of 0.032 and 0.008 for the active annotation time and higher ease of use rating metrics, respectively, indicating that the current tool significantly reduces annotation time and enhances ease of use. Moreover, the tool utilization for annotating different regions of interest from different modality scans and body regions shows its usability across modalities and areas of interest. MedImgAnnotator, which significantly reduces active annotation time for large imaging cohorts, is available as an executable file and as a Python script. Access link: https://ewunateassaye.github.io/developed-tools/medimgannotator.html

0.26

SWIMSS: An Open Multi-Center SwinUNETR Model for Multiple Sclerosis White Matter Lesion Segmentation

eess.IV ·2026-11-17 ·Federico Spagnolo, Po-Jui Lu, Mario Ocampo-Pineda, Lester Melie-Garcia, Esther Ruberte +23 more
code/data
Abstract

Purpose: To develop and validate SWIMSS (SWInUNETR for Multiple Sclerosis white matter lesion Segmentation), a SwinUNETR-based deep learning (DL) model for reliable automated white matter (WM) lesion segmentation, in a large multicentric cohort of people with multiple sclerosis (pwMS). Methods: A real-world longitudinal dataset of 1,385 pwMS from seven Swiss clinical centers was used to train, validate, and test SWIMSS and two state-of-the-art DL architectures: UNETR and MSSegDiff. Inference results obtained with LST-AI were also compared. Preprocessed magnetization-prepared rapid acquisition gradient echo and fluid-attenuated inversion recovery MRI sequences, acquired with various MR systems and field strengths, served as model inputs. Model performance was evaluated using the Dice similarity coefficient (DSC) with 95% confidence intervals (CI). Results: SWIMSS achieved the highest performance, with a DSC of 81.37 (95% CI: 80.63-82.11), outperforming UNETR (79.06; 95% CI: 78.33-79.79), MSSegDiff (75.70; 95% CI: 74.97-76.43), and LST-AI (63.19; 95% CI: 62.08-64.30). Normalized DSC followed a similar trend, with SWIMSS reaching 84.88. Lesion detection F1 achieved 81.14. Statistical analyses confirmed its superior performance (p < 0.001). Conclusion: SWIMSS achieved state-of-the-art performance for WM lesion segmentation. By making this model publicly available, we enable broader access to high-quality segmentation tools, allowing smaller centers, often lacking large annotated datasets or computational resources, to benefit from a model trained on a diverse, large-scale cohort. This promotes more equitable access to advanced imaging analysis and supports reproducibility and standardization in MS research.

0.22

SurgCBVR: A Multi-Domain Benchmark for Content-Based Surgical Video-to-Video Retrieval

eess.IV cs.AI ·2026-11-17 ·Mohammad Eslami, Mousa Moradi, Negin Ghamsarian, Nazlee Zebardast, Jennifer L Lindsey +4 more
benchmark
Abstract

Hospitals record thousands of hours of surgical video annually, yet these archives remain difficult to search by content. Surgeons cannot readily retrieve similar operations, complications, or workflow events. Existing surgical computer vision primarily produces labels rather than retrieving relevant videos. We introduce SurgCBVR, the first benchmark for content-based video-to-video retrieval in surgery. It integrates eight public datasets across four domains-ophthalmic, laparoscopic, robotic-assisted, and colonoscopy-covering six procedure types, 679 cases, and 76,489 clips (106 hours). SurgCBVR comprises two tiers: Scene, retrieving the same operative state across cases and sites, and Workflow, retrieving and localizing phase transitions and deviations. Scene includes 74,765 clips spanning 40 classes, three temporal granularities, and three playback speeds; Workflow contains 1,724 transition clips. Fixed clip lengths and frame counts, together with phase-classifier oracle and duration-only baselines, help assess label and timing shortcuts. We evaluate six generic and surgical foundation models, two video retrieval methods, and contrastive heads trained on SurgCBVR, using within-dataset, cross-dataset, and pooled-gallery retrieval restricted to the same procedure type. Frozen representations barely outperform a timing-only baseline, transition retrieval approaches chance, and trained heads lose up to half their accuracy across datasets. These findings expose substantial limitations in current video representations and establish SurgCBVR as a benchmark for advancing surgery-aware retrieval.

0.20

Uncovering the Invisible in Routine Radiology: Cross-Modal Detection of MRI-Verified Soft-Tissue Pathologies from CBCT via Physics-Guided 3D Self-Supervised Learning

eess.IV cs.CVcs.LG ·2026-11-17 ·Evgeny Alves Limarenko
Abstract

Routine X-ray modalities like cone-beam computed tomography (CBCT) are optimized for high-contrast mineralized tissues, leaving soft-tissue abnormalities buried beneath photon noise and below human visual perception. Thus, detecting non-calcified pathologies requires secondary magnetic resonance imaging (MRI). We demonstrate that sub-visual radiographic signatures of soft-tissue pathology are physically preserved within routine CBCT scans and can be extracted for opportunistic screening using a targeted, physics-guided deep learning pipeline, even under extreme paired-data scarcity. Using the temporomandibular joint (TMJ) as a model system (N = 212 paired CBCT-MRI joints), we address the severe overfitting of high-capacity 3D networks through a two-stage framework. First, we employ a frozen full-grid 3D masked autoencoder (BertsWin) pre-trained on 6,550 unlabeled CBCT volumes via the GradientConductor (GCond) optimizer and an anatomy-aware objective (PhysLoss) redirecting gradient flow into the [-300, 300] HU soft-tissue window. Second, automated localization of the condylar zenith drives a deterministic 3D cropping that eliminates 81% of background osseous variance. Evaluated via a patient-isolated 3x10-fold stratified cross-validation protocol, a statistically robust sub-visual signal for MRI-verified synovial effusion (ROC AUC = 0.793) emerges exclusively from representations pre-trained with the PhysLoss and GCond regime. Crucially, only this setup captures true 3D anatomical chirality (p < 0.001) and high intra-patient structural consistency (0.791) over inter-patient noise; conversely, identical architectures pre-trained with standard L2 loss or unmasked variance decomposition (MVC) collapse to random guessing. These findings establish a generalizable paradigm for repurposing routine, low-contrast radiographic scans into opportunistic screening tools for occult soft-tissue disease.

0.19

Beyond Accuracy: Benchmarking Uncertainty Quantification in Retinal Disease Screening

eess.IV ·2026-11-17 ·Mahvash Jebeli, Mohammad Eslami, Nazlee Zebardast, Lucia Sobrin, Tobias Elze
benchmarkdataset
Abstract

Reliable uncertainty quantification (UQ) is essential for evaluating retinal AI systems beyond classification accuracy, yet it remains unclear whether existing UQ strategies generalize across diseases, model architectures, and reliability criteria. We introduce a large-scale, multi-disease benchmark comprising over $242,000$ fundus photographs from $32$ datasets covering diabetic retinopathy, age-related macular degeneration, and glaucoma. We evaluate six representative UQ strategies across three Vision Transformer configurations, assessing discrimination, probabilistic calibration, selective prediction, and conformal prediction-set coverage. Our findings reveal no universally superior model or UQ strategy: methods that improve reliability in one disease or architecture may underperform in another, while improvements in discrimination, calibration, and selective prediction do not necessarily align. Notably, computationally intensive methods do not consistently outperform simple confidence scores, and domain-specific foundation models and calibration-oriented loss functions do not guarantee greater reliability. In contrast, conformal prediction provides a complementary framework for achieving near-nominal marginal prediction-set coverage across diverse settings, subject to its statistical assumptions. These findings challenge universal UQ recommendations and highlight the need for disease-specific, model-specific, and multidimensional reliability evaluation before clinical deployment. We release standardized dataset splits, trained checkpoints, evaluation code, and an interactive research demonstration to support reproducible benchmarking.

0.11