CS Paper Radar

Use of the Common Information Model (IEC 61970) for Standardized Data Exchange in HVDC Digital Twin Systems

Ferran Bohigas-Daranas, Arkadius Burek, Eduardo Prieto-Araujo, Oriol Gomis-Bellmunt

eess.SY ·submitted 2026-08-10 08:15 UTC · v1
published

Abstract

Digital Twins (DTw) are emerging as transformative tools for High Voltage Direct Current (HVDC) transmission systems, enabling real-time monitoring, predictive maintenance, and operational optimization. However, the effectiveness of these virtual replicas fundamentally depends on seamless, reliable data exchange with their physical counterparts and any other support system. The current landscape of HVDC DTw implementations reveals a critical challenge: the absence of standardized data exchange protocols leads to vendor lock-in, interoperability issues between systems from different vendors. The contribution of this paper is to propose the standardization of Common Information Model (CIM) defined in IEC 61970 standard family, as the data exchange methodology in HVDC DTws, which is exemplified with the Cigre B4 example, as well as connected to the IEC 61850 standard for real time station control, via the harmonization guidelines from the IEC 62361-102 technical report.

Comment
Based on work done by the Cigre WG B4.104 Presented at HVDC Colloquium organized by Leuven University in 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Automated consolidation of dispersed DSO data resources into a consistent digital twin of the distribution grid

eess.SY ·2026-11-03 ·Fabian Böhm, Benjamin Sawicki, Claudio Stucki, Pulkit Nahata, Gabriela Hug +1 more
published similarity 0.55
Abstract · This paper is a preprint of a paper accepted by IET conference proceedings and is subject to Institution of Engineering and Technology Copyr…

The energy transition causes a growing number of distributed flexible energy resources in the low voltage grid. To utilize that flexibility, automation and control algorithms are needed, which typically are developed in theoretical research. We build a cyberphysical algorithm test bed to bridge the gap between theoretical research and practical application in cooperation with a local DSO in Walenstadt, Switzerland. To obtain suitable monitoring and data analysis capabilities from their existing data landscape, we propose tool-independent data harmonization measures in preparation for a digital twin of the grid. For data extraction from high-security network zones we developed a secure pipeline that implements a logical data diode ensuring one-way traffic only. Furthermore, we established a test community of voluntary prosumer households, whose flexible assets were made accessible through a common backend, giving us actuation capabilities. The presented publish-subscribe architecture is not only suitable to integrate various data sources into a central data collection, but also to manage access privileges of different stakeholders. This could support unbundling of an organization's data flows and the implementation of data space concepts.

0.48

SEAL-DT: An End-to-End Security Engineering and Assurance Framework for Cross-Domain Digital Twins

cs.CR ·2026-10-12 ·Iraklis Varlamis, Stelios Zindros, Christos Sardianos, Thomas Lagkas, Panagiotis Sarigiannidis +1 more
similarity 0.52
Abstract

Cyber-physical systems connect physical processes, software, networks and organizations. Securing them requires a clear account of what happened, what was observed, which actions were authorized and what evidence supports each decision. Digital Twin (DT) descriptions often fail to explain how these elements stay consistent, blur the distinction between physical events and uncertain observations, or detach simulation results from their requirements and assumptions. This paper presents SEAL-DT (Security Engineering and Assurance Lifecycle for Digital Twins), a structured approach to building and evaluating secure DTs. It brings entity definitions, process models, deterministic simulations, data contracts, evidence records, automated tests and reproducible results into one connected model. The main contribution is an end-to-end DT security framework, spanning scenario definition, entity/process modelling, simulation, security decision logic, evidence handling, validation and reproducible reporting. Security decisions and simulation results thus trace back to their data, assumptions and requirements. A DT is more than a copy of system state: it states what it can observe, how accurate and current its information is, where it came from and which decisions it may support. We demonstrate SEAL-DT in five scenarios: Car2X protection, passive IoT-device detection, an industrial control surrogate, lawful acquisition in a smart home, and medical-IoT monitoring that preserves continuity of care. Each includes formal models, deterministic and negative experiments, uncertainty analyses, schema-valid fixtures, technical reports and verified manifests, testing multiple configurations under normal and adverse conditions. Results show that the framework supports consistent model construction, traceable execution and comparable internal validation, and that security findings link to observable evidence.

0.20

Digital Twin Enabled Talkative Power Conversion

eess.SY ·2026-11-16 ·Peter A. Hoeher, Yang Leng, Maximilian Mewis-Noll, Rongwu Zhu
similarity 0.49
Abstract

Talkative Power Conversion (TPC) is a paradigm in which communication is integrated directly into switched-mode power electronic converters (PECs) by modulating their inherent switching ripple. TPC enables simultaneous power transfer and information exchange without dedicated transmitter-side communication hardware, and avoids additional wiring. This paper combines, for the first time, the Digital Twin (DT) concept with the TPC paradigm. By establishing interaction between one or several physical power converters and their virtual counterpart(s), the DT framework enables enhanced modeling, prediction, and optimization of individual or networked PECs. We distinguish three coupling architectures--embedded DT, remote DT, and networked DT--and demonstrate the added value of combining DT and TPC concepts when the DT and PEC are not co-located. The proposed framework is based on state-space modeling in conjunction with Kalman filtering and facilitates joint treatment of data transmission, parameter estimation, and system operation, thereby improving robustness, adaptability, and power efficiency. The presented approach highlights the potential of DT-enhanced TPC as a key enabler for future cyber-physical energy systems with tightly integrated power and communication functionalities.

0.28

A Multi-Viewpoint Modeling Framework for Digital Twin Integration and Reuse with LLM-Assisted Compatibility Analysis

cs.SE ·2026-08-24 ·Nafiseh Soveizi, Milan Kopp, Parinaz Rashidi, Qing Shan, Geerten M. Hengeveld +2 more
similarity 0.48
Abstract · 45 page, 14 figs, 6 tables, 2 Appendix, Submitted to the International Journal on Software and Systems Modeling (SoSyM)

Digital Twin (DT) ecosystems integrate heterogeneous computational models to represent complex systems under evolving, purpose-specific objectives. Systematic reuse of existing high-quality models and datasets is essential for scalable DT development, yet is constrained by heterogeneity in semantic intent, data structures, behavioral interfaces, and execution environments. As a result, integration becomes a cross-model, cross-view consistency problem that is hard to predict, quantify, and compare across design choices. Existing standards and integration platforms address these concerns separately, offering limited support for structured, purpose-aware compatibility assessment and early feasibility analysis when models are reused under new DT objectives. This paper introduces a multi-viewpoint integration modeling framework grounded in the Reference Model of Open Distributed Processing (RM-ODP). The framework structures integration-relevant knowledge across domain, information, computational, engineering, and technology viewpoints, representing cross-view dependencies as explicit, machine-actionable metadata. It comprises (i) a viewpoint-structured Model Metamodel for systematic model description and discovery, and (ii) a pattern-aware Mismatch Detector that operationalizes cross-view compatibility constraints via integration patterns, combining deterministic rule generation with Large Language Model (LLM)-assisted reasoning. This enables systematic identification of semantic, informational, and runtime inconsistencies and supports reasoning about integration feasibility and effort before implementation. Expert validation and an environmental modeling case study show that the approach enables structured compatibility reasoning, improves transparency of integration assumptions, strengthens cross-view interoperability, and supports scalable reuse in heterogeneous DT ecosystems.

0.30

Data Center Load Reductions: Attribution, Measurement Limits, and Estimation

eess.SY ·2026-10-28 ·Abdallah Alalem Albustami, Ahmad F. Taha, Mohammad Alwahdanee, Zuhaib Shakeel Muhammad
similarity 0.48
Abstract

Hundreds of gigawatts of data center loads are seeking interconnection in the United States given the massive growth of artificial intelligence and cloud computing. In recent years, several incidents of data centers reducing their loads by hundreds to thousands of megawatts have been documented, raising grid reliability concerns. U.S. regulators have since ordered reliability standards for the integration of computational loads, and the North American Electric Reliability Corporation (NERC) now calls on transmission owners to install disturbance recorders at these facilities to support root cause analysis. Such recorders usually observe only electrical quantities at the point of interconnection (POI). A sudden load reduction can be caused by a change in workload or a switch to backup supply. This work shows when POI measurements can distinguish the two mechanisms. It is established that they can produce identical POI voltage and current in a quasi-static constant power model, and during the transient their separation depends on the reduction relative to measurement noise, the clearing time, the dynamics through which workload reaches the POI, and the recorder bandwidth. When POI data are insufficient, an estimator that uses workload data is proposed to determine how much of the facility stayed connected. The results of this work identify the measurements and grid information utilities need to determine why data center load dropped.

0.31

EMT Modeling and Coordinated Mode-Transition Ride-Through Control of Modern Data Centers

eess.SY ·2026-11-05 ·Junyuan Zheng, Salish Maharjan, Min Lwin, Soummya Roy, Zhaoyu Wang +3 more
similarity 0.48
Abstract

Large data centers are emerging as power-electronic loads whose response to grid voltage disturbances can affect bulk-system stability. This paper presents the composition and control characteristics of a proprietary electromagnetic transient (EMT) model of a modern data center comprising an uninterruptible power supply (UPS) with battery energy storage, induction-motor cooling loads, a computer room air handler (CRAH) driven by a variable-frequency drive (VFD), and an aggregated server load. A voltage-based state machine coordinates three aspects of the facility response: the UPS operating mode (eco, double conversion, or battery), the supply path of the CRAH, and a ramped reconnection of the grid-side UPS converter after the disturbance clears. A 100 MW facility is implemented in PSCAD/EMTDC and benchmarked against the PSSE PERC1 aggregate data center model under a symmetrical three-phase fault and low- and high-voltage ride-through (LVRT/HVRT) events. The two models agree closely in their voltage and active-power trajectories, while the EMT model also resolves the converter and motor-reacceleration transients that the phasor-domain model cannot.

0.50

Comparison of Open-Source PSCAD EMT Models for Large-Scale AI Data Centers in Smart Grids

eess.SY ·2026-11-17 ·Alex Chen, Ahmad Mohammad Saber, Deepa Kundur
similarity 0.48
Abstract · 5 pages, 2 figures, submitted to PESGM 2027

The rapid deployment of artificial intelligence data centers (AIDCs) introduces gigawatt-scale, highly nonlinear, and fast-varying electronic loads that challenge grid voltage regulation, frequency stability, and disturbance ride-through. Capturing their transient behavior during grid faults and rapid computational workload swings requires high-fidelity electromagnetic transient (EMT) simulations rather than root mean square models. However, limited methodologies exist to audit the component-level adequacy of EMT AIDC models. This paper proposes a software-agnostic, 41-point fidelity framework spanning 11 categories that synthesizes 37 criteria from an existing modeling guideline with four novel requirements: frequency ride-through compliance, disaggregated fan and chiller cooling loads, temperature-dependent thermal response, and DC information technology (IT) load representations. Applying this framework to the four publicly available AIDC models in PSCAD/EMTDC reveals varying degrees of completeness: while the models capture IT load transitions, uninterruptible power supplies, and transfer switches for bulk stability studies, critical gaps remain in electro-thermal cooling coupling, internal protective relaying, and site-level controls. Addressing these gaps will enable comprehensive protection coordination and ride-through compliance studies.

0.20

Hosting Capacity Assessment of Data Centers with Voltage Ride-Through Capability in Power Systems

eess.SY ·2026-09-02 ·Pengyu Ren, Wei Sun, Fei Teng
similarity 0.48
Abstract

Large data centers are emerging as concentrated, power-electronic grid loads whose abrupt disconnection or transfer to on-site backup supply during voltage disturbances can remove large demand from the power system, and may create a system-level stability problem. Their interconnection feasibility therefore depends not only on steady-state thermal and voltage limits, but also on whether internal power-conditioning systems can maintain IT service while limiting customer-initiated load reduction. This paper presents a voltage ride-through (VRT)-aware data center and grid co-planning framework that couples transmission-level fault simulation with an internal data center ride-through model. Python-based dynamic simulations generate point-of-interconnection (POI) voltage trajectories under selected network faults, and the resulting waveforms drive an internal model incorporating IT and cooling-load dynamics, DC-link, Uninterruptible Power Supply (UPS) response, and converter apparent power limits. The IEEE 118-bus case study shows that internal VRT capability can become a binding interconnection constraint: steady-state planning alone can overestimate feasible data center capacity, whereas increased UPS converter headroom progressively restores hosting capacity. Under the reduced-order response models studied, the grid-forming mode provides greater ride-through margin than the current-limited grid-following mode under the same network fault conditions. The results further show that VRT constraints can materially change both the total hosting capacity of data centers and its spatial allocation across candidate interconnection buses.

0.16