Abstract

Strictures caused by esophageal cancer can narrow down the esophageal lumen, leading to dysphagia. Palliation of dysphagia has driven the development of a Robotic Soft Esophagus (RoSE), which provides a novel in vitro platform for esophageal stent testing and food viscosity studies. In RoSE, peristaltic wave generation and control were done in an open-loop manner since the conduit lacked visibility and embedded sensing capability. Hence, in this work, RoSE version 2.0 (RoSEv2.0) is designed with embedded Time Of Flight (TOF) and pressure sensors to measure conduit displacement and air pressure, respectively, for modeling and control. Model Predictive Control (MPC) of RoSEv2.0 is implemented to govern the peristalsis and air pressure profile autonomously. The implemented MPC used Sparse Identification Nonlinear Dynamics with Control (SINDYC) models to estimate the future states of ROSEv2.0. The dynamic models are discovered from the TOF and pressure sensor data. Peristalsis waves of speed 20 mm/s, wavelength 75 mm, and amplitudes 5, 7.5, and 10 mm were successfully generated by the MPC. Additionally, RoSEv2.0 with the MPC was employed to perform stent migration testing with various food bolus consistencies. The major contribution claimed in this paper is the application of SINDYC-based MPC to solve the closed-loop control problem of RoSE for achieving desired peristaltic waves.

Comment
Accepted manuscript. 12 pages. Published in IEEE Transactions on Industrial Electronics. Project page: https://bhattner143.github.io/rosev2-dtsindyc.github.io/ Code: https://github.com/bhattner143/SINDYc_MPC_RoSE_symmetric_peristaltic
Journal ref
IEEE Trans. Ind. Electron., vol. 69, no. 10, pp. 10363-10373, Oct. 2022
DOI
10.1109/TIE.2021.3121755

Closest papers

Nearest neighbours by meaning across the whole index.

RoSE: A Robotic Soft Esophagus for Endoprosthetic Stent Testing

cs.RO ·2026-08-10 ·Dipankar Bhattacharya, Sherine Jesna V. A., Leo K. Cheng, Weiliang Xu
publishedcode/datahighly cited similarity 0.58
Abstract · Author accepted manuscript. 31 pages, 13 figures, 3 tables. Published in Soft Robotics (2021). Project page: https://bhattner143.github.io/r…

Soft robotic systems are well suited for developing devices for biomedical applications. A bio-mimicking robotic soft esophagus (RoSE) is developed as an in vitro testing device of endoprosthetic stents for dysphagia management. Endoprosthetic stent placement is an immediate and cost-effective therapy for dysphagia caused by malignant esophageal strictures from esophageal cancer. However, later stage complications, like stent migration, could weaken swallow efficacy in the esophagus. The stent radial force (RF) on the esophageal wall is pivotal in avoiding stent migration. Due to limited randomized controlled trials in patients, stent design and stenting guidelines remain incomplete. To address this knowledge deficit, we investigate RoSE by implanting two stents (A and B) of different radial stiffness characteristics, to measure stent RF and its effect on migration. Endoscopic manometry under peristalsis is also performed to study the impact of stenting and stent dysfunction on intra-bolus pressure signatures (IBPSs) and swallowing efficacy. Each implanted stent undergoes experiments with varied peristalsis velocity, wavelength, and bolus concentrations. The results show that stiffer stent B has a higher RF, whereas stent A maintains a lower RF profile due to lesser stiffness. High RF is necessary to minimize migration under prolonged peristaltic contractions in RoSE. For manometry, stent A slightly increases IBPS, but stiffer stent B significantly decreases IBPS, especially for higher-concentration boluses. If a stiffer stent buckles, it can reduce swallow efficacy and cause recurrent dysphagia. RoSE is therefore an innovative soft robotic platform for testing endoprosthetic stents and addressing clinical challenges in stent evaluation.

0.84

Learning-Based Pressure Predictive Control of a Vertebraic Soft Robotic Tail

cs.RO ·2026-09-24 ·Wenjian Yang, Nan Huang, Yukang Nie, Fang Chen, Wanchao Chi +2 more
similarity 0.45
Abstract

Soft robots have attracted much attention for their safe human-robot interaction and flexibility, but the typical continuum structure and nonlinear material behavior make the kinematics modelling complex, especially in non-static motions. In this work, we proposed an LSTM-based pressure predictive control (PPC) for the motion control of a vertebraic soft robotic tail and the coordination with a quadruped robot. The PPC consists of an inverse kinematics (IK) model, a forward kinematics (FK) model and a pressure compensation (P-comp) model, and achieves non-static and quasi-static motion control of the tail. Compared with the IK-only model, the average RMSE of the PPC's simulation trajectories reduces by 69.8%, when executing target trajectories. In the coordinated motions of the soft tail quadruped, using a prediction data set to train the PPC enables next-moment action prediction and reduces computation time by 60.9%, which enhances the real-time response of the tail to match the quadruped torso's moving rate. The PPC provides a simple and effective method to model the soft tail for both non-static and quasi-static motion control, and grants the soft tail quadruped with the functionality of interacting with the environment.

0.25

Orientation Control of Soft Robots via Adiabatic Spectral Submanifolds

cs.RO eess.SY ·2026-09-13 ·Aron Karakai, Roshan S. Kaundinya, Mike Yan Michelis, Robert Katzschmann, George Haller
published similarity 0.45
Abstract · This paper has been accepted for presentation at the 2026 IEEE Conference on Decision and Control (CDC)

Soft robots are commonly sought for safety-critical interactions in delicate environments, where accurate position and orientation control is imperative. Model predictive control (MPC) offers a solution, but it requires a model of the robot's infinite-dimensional nonlinear dynamics that is at once accurate and computationally cheap. Recent theory on adiabatic spectral submanifolds (aSSMs) and their applications to soft robots provide data-driven model-reduction methods to construct such models. Here, we extend these methods to identify aSSMs from enlarged observable datasets and upgrade the currently available aSSM-MPC schemes. Evaluated on a high-fidelity finite-element simulation of a pressure-actuated soft arm, our controller reduces position and orientation tracking error by more than 60% compared to existing data-driven baselines.

0.47

Dynamic Shape Control of Soft Trunk Robots

cs.RO ·2026-11-04 ·Hehui Zheng, Marc Stampanoni, Roshan S. Kaundinya, Ronan Hinchet, George Haller +1 more
similarity 0.42
Abstract

Controlling the shape profile of soft trunk robots extends their reach into complex regions of the workspace and enhances their use in practical applications. Recent advances in soft robot design have enabled soft trunk robots to achieve greater flexibility in conforming to complex shapes. Specifically, trunk robots whose geometries are designed as helicoids have been shown to enable extreme shape-changing capabilities. Their compliance makes them highly nonlinear, which in turn makes shape control difficult. On similar tendon-driven trunk robots, model-based controllers based on the theory of adiabatic spectral submanifolds (aSSMs) have achieved high accuracy in closed-loop end-effector tracking. We extend this approach by learning an aSSM model of the full body of a trimmed-helicoid soft trunk robot from data and use this in a model predictive control (MPC) scheme to demonstrate a range of shape control tasks on hardware. On closed-loop dynamic shape regulation, our method outperforms the available linear baselines by a factor of 10. In human-in-the-loop interactive demos, our method completes section-by-section shaping and balances a tennis ball for over 25 seconds, while the linear baselines fall short. A model-free reinforcement learning policy trained for 12 hours on hardware fails on the same balancing task. These results establish aSSM-based MPC as a practical route to full-body shape control on real soft hardware.

0.21

Towards Effective Physical Reservoir Computing with a Pneumatic Soft Robot

cs.RO ·2026-09-02 ·Jeevan Hebbal Manjunath, Jun Wang, Suyi Li, Wenlong Zhang
publishedbenchmark similarity 0.42
Abstract · 6 pages; 5 figures, accepted for 2026 Modeling, Estimation, and Control Conference (MECC)

Physical reservoir computing (PRC) refers to the use of a physical dynamical system as a computational resource for tasks such as state estimation and control, but there has been a lack of formal study of design rules towards more effective design of such physical reservoirs. Using a pneumatic soft arm with a five-pouch sensing column, this work studies how the pouch interconnection topology, robot stiffness, and the number of instrumented sensors affect bending-angle estimation performance. Across 36 matched trials spanning waveform, baseline pressure of the sensing column, and actuation range, all designs are evaluated under the same-time bending-angle estimation benchmark using 0.2 s of pressure history and a fixed ridge estimator. Our analysis of the experimental results leads to three design guidelines. First, independently sealed pouches preserve a much richer observable state than a shared manifold. Second, increasing the baseline pressure of the sensing column makes the pouch responses more redundant and increases estimation error most strongly in the coupled topology. Third, in the sealed topology, two strategically placed sensors already recover most of the attainable benefit, three capture essentially all of it, and additional sensors provide little or no additional value. In summary, the results suggest that topology, stiffness, and number of instrumented sensors should be co-designed for accurate PRC of soft robot states; stronger excitation alone cannot recover the diversity that poor design choices have already removed.

0.30

Respiratory Mask Testing: Airway Inertance and System Dynamics

eess.SY physics.bio-ph ·2026-10-03 ·Mark M. Koeroghlian, Suraj Pawar, Raul G. Longoria
unusual similarity 0.41
Abstract

Life support equipment coupled to the human lungs forms a complex, nonlinear dynamic system. Current respiratory mask test standards rely on sinusoidal breathing machines and surrogate trachea geometries that substantially reduce physiologically relevant airway inertance. This paper shows that the ISO 16900-5 trachea does not generate physiologically meaningful exhalation momentum, limiting the ability of standard test configurations to reveal valve dynamics relevant to human use. A physiologically motivated ``lip-nozzle'' surrogate is introduced as a diagnostic tool to restore realistic momentum transfer, enabling observation of exhalation behavior that is not observable under existing test conditions. Nonlinear dynamic simulations incorporating this surrogate reveal a force-balanced operating regime in which exhalation-jet momentum can offset flow-induced valve resistance, in one representative case reversing exhalation mean effective pressure from resistive to assistive. This effect depends on the relationship between the valve's restoring force and lift, representing a design consideration relevant to future valve development. Implications for mask design, valve placement, and future test methods are discussed. This work does not propose new performance limits or acceptance criteria; rather, it demonstrates how current test fixtures suppress inertance- and momentum-driven effects that can materially influence exhalation valve dynamics.

0.26

Optimal Excitation Trajectories for System Identification of Underwater Vehicles

cs.RO ·2026-09-15 ·Fotis Panetsos, Kostas J. Kyriakopoulos
top venue similarity 0.41
Abstract · Accepted for publication at the 2026 IEEE International Conference on Robotics and Automation (ICRA 2026)

In this work, we propose a structured methodology for the system identification of underwater vehicles through the design of optimal excitation trajectories. To this end, the trajectories are parameterized using Bezier curves, which ensure smooth and differentiable motion profiles while facilitating the enforcement of constraints through appropriate manipulation of the control points. An optimization problem is formulated to determine a dynamically feasible excitation trajectory that respects safety limits and maximizes the quality of the collected data, thereby enabling reliable estimation of the vehicle's dynamic parameters using least squares. The proposed methodology is experimentally validated in a laboratory water tank, where the dynamic parameters, identified from the optimized trajectory, are evaluated by predicting the vehicle's velocity through forward simulation on previously unseen trajectories.

0.40

Synthetic Dataset Generation, Physical Consistency and Active Learning for Shape-Informed Surrogate Modeling of Hemodynamics

cs.CE physics.flu-dyn ·2026-10-19 ·Francesco Romor, Richard Schussnig, Charles A. Taylor, Gerhard A. Holzapfel, Alfonso Caiazzo
similarity 0.41
Abstract

Model order reduction has the potential to enable real-time patient-specific assessment of cardiovascular flows. However, it still faces significant challenges stemming from the geometric variability of vascular anatomies. Building upon the SynthAorta dataset (Bosnjak et al., IEEE Trans. Med. Imag. 45(1), 2026) of physiological aortic geometries, we generate an extensive dataset of physiologically consistent computational fluid dynamics solutions through an automatic boundary-condition adjustment procedure. A common reference geometry allows all patient-specific anatomies to be represented by displacement fields, providing point-to-point correspondence without the need for geometric registration. Based on this dataset, we develop Graph U-Net and Transformer U-Net surrogate models to predict velocity and pressure fields at peak systole. We further investigate two strategies to enhance data efficiency and prediction accuracy: active learning and differentiable physical consistency constraints based on the finite element residual. The results show that active learning is strongly regime-dependent: while it offers little benefit over random sampling during early training, it improves performance during fine-tuning through gradient- and subspace-based acquisition strategies. Similarly, physical consistency constraints prove to be substantially more effective as a fine-tuning objective than as a regularizer applied throughout training. Finally, out-of-distribution studies demonstrate that the primary limitation of surrogate models lies in the geometric support of the underlying parametrization rather than in the neural network architectures themselves. The proposed framework combines synthetic dataset generation, geometry-aware surrogate modeling, physics-informed optimization, and active learning into a scalable workflow for inter-patient hemodynamic prediction.

0.03