Respiratory Mask Testing: Airway Inertance and System Dynamics

Mark M. Koeroghlian, Suraj Pawar, Raul G. Longoria

eess.SY physics.bio-ph ·submitted 2026-10-03 02:23 UTC · v1
unusual

Abstract

Life support equipment coupled to the human lungs forms a complex, nonlinear dynamic system. Current respiratory mask test standards rely on sinusoidal breathing machines and surrogate trachea geometries that substantially reduce physiologically relevant airway inertance. This paper shows that the ISO 16900-5 trachea does not generate physiologically meaningful exhalation momentum, limiting the ability of standard test configurations to reveal valve dynamics relevant to human use. A physiologically motivated ``lip-nozzle'' surrogate is introduced as a diagnostic tool to restore realistic momentum transfer, enabling observation of exhalation behavior that is not observable under existing test conditions. Nonlinear dynamic simulations incorporating this surrogate reveal a force-balanced operating regime in which exhalation-jet momentum can offset flow-induced valve resistance, in one representative case reversing exhalation mean effective pressure from resistive to assistive. This effect depends on the relationship between the valve's restoring force and lift, representing a design consideration relevant to future valve development. Implications for mask design, valve placement, and future test methods are discussed. This work does not propose new performance limits or acceptance criteria; rather, it demonstrates how current test fixtures suppress inertance- and momentum-driven effects that can materially influence exhalation valve dynamics.

Closest papers

Nearest neighbours by meaning across the whole index.

Design and Architecture of Airmod: An Active Noise Cancellation and Deep Learning System for Real-Time Respiratory Rate Estimation from Tracheal Sounds

cs.SD ·2026-10-27 ·Shang-Ran Huang, Fu-Shun Hsu, Ji-Chang Huang, Chuan Chen, Shou-Zen Fan +3 more
similarity 0.48
Abstract

Tracheal auscultation is recommended by clinical practice guidelines, and required by some U.S. state regulations, for monitoring ventilation during procedural sedation and monitored anesthesia care. However, continuous auscultation with a conventional stethoscope is impractical, susceptible to ambient noise, and difficult to interpret. We developed the Artificial Intelligence Respiratory MOnitoring Device (Airmod), an FDA-cleared software as a medical device (510(k) K242798) that continuously monitors tracheal sounds and estimates breath-to-breath respiratory rate in real time. In this paper, we describe its software architecture and key processing modules. Ambient noise is suppressed by active noise control, using a normalized least-mean-square adaptive filter with a dual-microphone electronic stethoscope. A multiclass convolutional bidirectional gated recurrent unit (CNN-BiGRU) model detects inhalations and exhalations in 15-s inference windows. It was trained on HF_Tracheal_V2, a new database of 373 continuous tracheal sound recordings (8,521 min; 107,644 labeled inhalations) from 369 subjects under sedation. To handle continuous acoustic streaming, Airmod runs inference on overlapping 15-s windows. It refines the detected inhalations by removing incomplete events, low-energy false positives, and double counts, concatenates them into a history list, and estimates respiratory rate from the mean period of the last three breaths. On the test set, at the default 2-s prediction interval with refinement enabled, inhalation detection achieved a sensitivity of 0.828, a positive predictive value of 0.832, and an F1-score of 0.830. Airmod also broadcasts the noise-cancelled tracheal sound and displays a real-time spectrogram to help clinicians recognize respiratory abnormalities.

0.21

OUCH: Objective, Uniform, Controlled Haptic Stimulation for Automated Neurological Assessment

cs.RO ·2026-11-03 ·Sherry Choi, Sitao Sunny Li, Joseph Romero, Lillian Chin, Ashwin G. Ramayya +2 more
benchmark similarity 0.47
Abstract · 8 pages, 7 figures. Supplementary video in ancillary files. Sherry Choi and Sitao Sunny Li contributed equally to this work

Motor responses evoked by noxious stimulation are used to assess neurological function in hospitalized patients with disorders of consciousness. In standard bedside assessments, these stimuli are applied manually, resulting in substantial variation in force, duration, frequency, and location. Here, we present OUCH (Objective, Uniform, Controlled Haptic stimulation), a wrist-worn device that uses pneumatic actuation to deliver noxious mechanical stimuli. OUCH combines stacked pneumatic pouch actuators, a rigid indenter, and a compliant spacer designed to buckle at a set load, so that the indenter contacts the skin only during actuation. We characterize the device using blocked force tests, clinician evaluation, finite element analysis, and a deformable pressure testbed, and benchmark it against a commercially available handheld pressure algometer. At 200 kPa pouch inflation pressure, our indenter concentrated its load into an estimated contact pressure of 18,500 kPa, over 25 times that of the algometer tip, while requiring less total force. On the deformable testbed, it localized deformation near the surface, while deformation at depth remained comparable to the algometer. As a result, in preliminary perceptual testing, our indenter elicited discomfort at approximately 89% lower applied force than the algometer, demonstrating the feasibility of evoking discomfort with a compact, wearable soft actuator. These results show that combining pneumatic actuation with designed contact geometry enables controlled, repeatable noxious stimulation at the wrist, providing a foundation for objective neurological assessment.

0.25

RoSE: A Robotic Soft Esophagus for Endoprosthetic Stent Testing

cs.RO ·2026-08-10 ·Dipankar Bhattacharya, Sherine Jesna V. A., Leo K. Cheng, Weiliang Xu
publishedcode/datahighly cited similarity 0.45
Abstract · Author accepted manuscript. 31 pages, 13 figures, 3 tables. Published in Soft Robotics (2021). Project page: https://bhattner143.github.io/r…

Soft robotic systems are well suited for developing devices for biomedical applications. A bio-mimicking robotic soft esophagus (RoSE) is developed as an in vitro testing device of endoprosthetic stents for dysphagia management. Endoprosthetic stent placement is an immediate and cost-effective therapy for dysphagia caused by malignant esophageal strictures from esophageal cancer. However, later stage complications, like stent migration, could weaken swallow efficacy in the esophagus. The stent radial force (RF) on the esophageal wall is pivotal in avoiding stent migration. Due to limited randomized controlled trials in patients, stent design and stenting guidelines remain incomplete. To address this knowledge deficit, we investigate RoSE by implanting two stents (A and B) of different radial stiffness characteristics, to measure stent RF and its effect on migration. Endoscopic manometry under peristalsis is also performed to study the impact of stenting and stent dysfunction on intra-bolus pressure signatures (IBPSs) and swallowing efficacy. Each implanted stent undergoes experiments with varied peristalsis velocity, wavelength, and bolus concentrations. The results show that stiffer stent B has a higher RF, whereas stent A maintains a lower RF profile due to lesser stiffness. High RF is necessary to minimize migration under prolonged peristaltic contractions in RoSE. For manometry, stent A slightly increases IBPS, but stiffer stent B significantly decreases IBPS, especially for higher-concentration boluses. If a stiffer stent buckles, it can reduce swallow efficacy and cause recurrent dysphagia. RoSE is therefore an innovative soft robotic platform for testing endoprosthetic stents and addressing clinical challenges in stent evaluation.

0.84

CT-RespGeomLib: Deterministic reconstruction of CT airway masks into editable,port-matched lumen geometry

eess.SY ·2026-11-12 ·Nichula Wasalathilaka, Kevin Dawson, Chinthaka Jacob, Mervyn Parakrama Ekanayake, Roshan Godaliyadda
similarity 0.44
Abstract

Patient-specific airway modelling requires geometrically consistent lumen surfaces with identifiable boundaries and support for controlled anatomical modifications. We present CT-RespGeomLib, a deterministic framework that converts CT airway masks into two complementary representations: an editable assembly of semantically labelled pipe and junction blocks connected through canonical shared ports, and a fused lumen surface reconstructed from tapered implicit primitives with validated port-to-boundary loop correspondence. The parametric representation further enables localised modelling of airway stenosis and dilation without re-segmentation. Evaluated on 42 reference airway masks from ATM22 (15 cases) and AeroPath (27 cases), the framework produced 37 topologically accepted reconstructions, with a median port-to-loop distance of 0.123 mm across 2174 matched ports. Reconstructed and reference equivalent radii showed strong agreement ($R^2 = 0.976$), with a mean bias of -0.414 mm arising primarily from the circular, inscribed-radius representation. Controlled pathology modelling generated 40 variants across five patient-specific geometries, including 25-75% stenosis and 50% dilation at tracheal and main-bronchus locations. Prescribed radius changes were reproduced with a mean absolute ratio error of 0.0056, while the median 95th-percentile deviation outside the modified region was 0.111 mm. Downstream applicability was demonstrated through volume meshing and an OpenFOAM simulation with individually prescribed model-based resistance conditions at 62 outlets. Although additional surface preparation may be required for numerical meshing, CT-RespGeomLib provides a reproducible framework for CT-derived airway reconstruction, quantitative boundary validation and controlled geometric pathology modelling.

0.30

A Physics-Conditioned Neural Operator for Generalization of Atrioventricular Valve Mechanics across Pressure and Tissue Properties

cs.LG ·2026-09-20 ·Shawn Koohy, Wensi Wu, Matthew A Jolley, Paris Perdikaris
similarity 0.43
Abstract · Preprint submission v2

Mitral and tricuspid regurgitation are the most common regurgitant valvular lesions, yet only a minority of severe cases undergo corrective surgery. Rapid assessment of valve mechanics could enable earlier, more precise intervention, but finite element (FE) analysis is slow to repeat across the many loading and tissue-property values of interest, which for a given valve are not known in advance. We introduce the Physics-Conditioned Neural Operator (PCNO), a transformer-based neural operator predicting leaflet displacement, strain, and stress fields conditioned on systolic blood pressure and tissue properties. PCNO is trained on, and evaluated against, FEBio simulations of functional and regurgitant mitral and tricuspid valves and of three mitral pathologies. With pressure and all material parameters simultaneously outside the training support, displacement error against FE reaches 4.48% and the mean errors of unsupervised geometric measures of valve function stay within 3.5%, indicating a conditioned solution operator over parameter space rather than an interpolator of the training set. Under this shift, PCNO is also more accurate than graph neural network and graph neural operator baselines trained on the same simulations, with the largest margins in stress.

0.52

SmartFlex: An Adaptive Lumbar Support System Based on Posture Recognition and Air Bag Array

cs.HC ·2026-09-16 ·Ben Xiaolu Huang
similarity 0.43
Abstract · 4 pages, 5 figures, Accepted for publication in the Companion of the 2026 ACM International Joint Conference on Pervasive and Ubiquitous Com…

Low back pain (LBP) is a leading cause of disability worldwide and affects populations ranging from working adults to students with prolonged sitting habits. Conventional lumbar support belts are generally static and non-adaptive, which limits their ability to accommodate dynamic postural changes and individualized comfort requirements. This paper presents SmartFlex, an intelligent wearable lumbar support system that integrates real-time posture recognition with an adaptive air bag array. The system uses a JY901S gyroscope sensor to detect user posture and a lightweight TinyML neural network deployed on an Arduino R4 UNO to process posture data at the edge. Based on the recognized posture state, a closed-loop pneumatic control system dynamically inflates or deflates 14 distributed air bags through four independent micro air pumps to provide targeted biomechanical support. Evaluation results show that SmartFlex achieves over 94% posture recognition accuracy and generates corresponding pressure-control commands with a sensing-to-command delay of less than 120 ms. The pneumatic system operates within a calibrated pressure range of 15-85 kPa. A user study with 20 participants produced a 4.5/5 rating for support effectiveness, suggesting that adaptive wearable support may improve daily sitting comfort and reduce lumbar fatigue.

0.33

Side-Vent Design for Microphone-Based Mechanomyography Sensors: Modeling and Experimental Evaluation of Contact Dependence

cs.HC ·2026-10-11 ·Cong Liu, Xiao Jin, Zhenhua Yu
similarity 0.43
Abstract · 10 pages, 9 figures, 1 table. Submitted to IEEE Sensors Journal

Wearable muscle sensing for rehabilitation, assistive robotics, and electrical-stimulation feedback needs mechanomyography sensors less sensitive to fit changes during wear. In microphone-based mechanomyography, cavity pressure depends on rim contact, a dependence housing design has rarely targeted. This study evaluates a side-vented housing, whose vent opens a pressure-relief path in parallel with the rim to lower contact dependence, and quantifies the acoustic-gain cost. Thermoviscous finite-element simulations compared twenty cavity configurations under prescribed source motion. Paired bench sweeps over 10-200 Hz on both housings compared direct contact with a Gap-ring spacer, a radially grooved spacer ring. At 100 Hz, side venting reduced the simulated acoustic-gain variation across 0.10-0.50 mm rim clearances from 25.8 to 10.0 dB and cost 5.5 dB of gain at 0.20 mm clearance. Velocity fields and branch-flow calculations identified this path. At the higher speaker drive level, the Gap-ring spacer caused median attenuations of 13.6 dB (vented) and 30.1 dB (unvented) relative to direct contact. In this front end, a 35.9-dB signal-gain increase at 100 Hz raised the calculated operational-amplifier voltage-noise gain by 1.6 dB. A single-participant demonstration of paced elbow flexion and extension compared envelope timing and spectra between housings, finding similar envelope timing (correlation 0.935) and broadly similar spectra (correlation 0.956). Vent area trades acoustic gain against contact dependence and can therefore serve as a housing design parameter.

0.31

Towards Effective Physical Reservoir Computing with a Pneumatic Soft Robot

cs.RO ·2026-09-02 ·Jeevan Hebbal Manjunath, Jun Wang, Suyi Li, Wenlong Zhang
publishedbenchmark similarity 0.43
Abstract · 6 pages; 5 figures, accepted for 2026 Modeling, Estimation, and Control Conference (MECC)

Physical reservoir computing (PRC) refers to the use of a physical dynamical system as a computational resource for tasks such as state estimation and control, but there has been a lack of formal study of design rules towards more effective design of such physical reservoirs. Using a pneumatic soft arm with a five-pouch sensing column, this work studies how the pouch interconnection topology, robot stiffness, and the number of instrumented sensors affect bending-angle estimation performance. Across 36 matched trials spanning waveform, baseline pressure of the sensing column, and actuation range, all designs are evaluated under the same-time bending-angle estimation benchmark using 0.2 s of pressure history and a fixed ridge estimator. Our analysis of the experimental results leads to three design guidelines. First, independently sealed pouches preserve a much richer observable state than a shared manifold. Second, increasing the baseline pressure of the sensing column makes the pouch responses more redundant and increases estimation error most strongly in the coupled topology. Third, in the sealed topology, two strategically placed sensors already recover most of the attainable benefit, three capture essentially all of it, and additional sensors provide little or no additional value. In summary, the results suggest that topology, stiffness, and number of instrumented sensors should be co-designed for accurate PRC of soft robot states; stronger excitation alone cannot recover the diversity that poor design choices have already removed.

0.30