RoSE: A Robotic Soft Esophagus for Endoprosthetic Stent Testing

Dipankar Bhattacharya, Sherine Jesna V. A., Leo K. Cheng, Weiliang Xu

cs.RO ·submitted 2026-08-10 17:40 UTC · v1
publishedcode/datahighly cited

Abstract

Soft robotic systems are well suited for developing devices for biomedical applications. A bio-mimicking robotic soft esophagus (RoSE) is developed as an in vitro testing device of endoprosthetic stents for dysphagia management. Endoprosthetic stent placement is an immediate and cost-effective therapy for dysphagia caused by malignant esophageal strictures from esophageal cancer. However, later stage complications, like stent migration, could weaken swallow efficacy in the esophagus. The stent radial force (RF) on the esophageal wall is pivotal in avoiding stent migration. Due to limited randomized controlled trials in patients, stent design and stenting guidelines remain incomplete. To address this knowledge deficit, we investigate RoSE by implanting two stents (A and B) of different radial stiffness characteristics, to measure stent RF and its effect on migration. Endoscopic manometry under peristalsis is also performed to study the impact of stenting and stent dysfunction on intra-bolus pressure signatures (IBPSs) and swallowing efficacy. Each implanted stent undergoes experiments with varied peristalsis velocity, wavelength, and bolus concentrations. The results show that stiffer stent B has a higher RF, whereas stent A maintains a lower RF profile due to lesser stiffness. High RF is necessary to minimize migration under prolonged peristaltic contractions in RoSE. For manometry, stent A slightly increases IBPS, but stiffer stent B significantly decreases IBPS, especially for higher-concentration boluses. If a stiffer stent buckles, it can reduce swallow efficacy and cause recurrent dysphagia. RoSE is therefore an innovative soft robotic platform for testing endoprosthetic stents and addressing clinical challenges in stent evaluation.

Comment
Author accepted manuscript. 31 pages, 13 figures, 3 tables. Published in Soft Robotics (2021). Project page: https://bhattner143.github.io/rose-stent.github.io/
Journal ref
Soft Robotics, Vol. 8, No. 4 (2021)
DOI
10.1089/soro.2019.0205

Closest papers

Nearest neighbours by meaning across the whole index.

Nonlinear Model Predictive Control of a Robotic Soft Esophagus

cs.RO ·2026-08-10 ·Dipankar Bhattacharya, Ryman Hashem, Leo K. Cheng, Weiliang Xu
top venuecode/datahighly cited similarity 0.58
Abstract · Accepted manuscript. 12 pages. Published in IEEE Transactions on Industrial Electronics. Project page: https://bhattner143.github.io/rosev2-…

Strictures caused by esophageal cancer can narrow down the esophageal lumen, leading to dysphagia. Palliation of dysphagia has driven the development of a Robotic Soft Esophagus (RoSE), which provides a novel in vitro platform for esophageal stent testing and food viscosity studies. In RoSE, peristaltic wave generation and control were done in an open-loop manner since the conduit lacked visibility and embedded sensing capability. Hence, in this work, RoSE version 2.0 (RoSEv2.0) is designed with embedded Time Of Flight (TOF) and pressure sensors to measure conduit displacement and air pressure, respectively, for modeling and control. Model Predictive Control (MPC) of RoSEv2.0 is implemented to govern the peristalsis and air pressure profile autonomously. The implemented MPC used Sparse Identification Nonlinear Dynamics with Control (SINDYC) models to estimate the future states of ROSEv2.0. The dynamic models are discovered from the TOF and pressure sensor data. Peristalsis waves of speed 20 mm/s, wavelength 75 mm, and amplitudes 5, 7.5, and 10 mm were successfully generated by the MPC. Additionally, RoSEv2.0 with the MPC was employed to perform stent migration testing with various food bolus consistencies. The major contribution claimed in this paper is the application of SINDYC-based MPC to solve the closed-loop control problem of RoSE for achieving desired peristaltic waves.

0.94

CROPS: Cosserat-Rod-Based Co-Design of Soft Slender Programmable Material Systems for Biomedical Applications

cs.CE cs.RO ·2026-10-16 ·Aaditya Chandrasekhar, Dex Doksoo Lee, Hyunwoo Kwon, Shicheng Li, Wei Chen
similarity 0.47
Abstract · Submitted to Finite Elements in Analysis and Design

Slender structures made of stimuli-responsive materials represent an emerging class of programmable material systems, with applications in soft robotics, minimally invasive surgery, wearable electronics, and deployable structures. In biomedical applications, the on-demand design of slender structures, encompassing both their material layout and actuation, is essential to harnessing their large deformation and multiphysics actuation to meet patient-specific design requirements. However, owing to geometric and material nonlinearities, their structure-actuation-response relationship is highly nonintuitive and computationally demanding. This often makes trial-and-error and conventional design approaches challenging for addressing patient-specific needs. To this end, we present a Cosserat-rod-based design optimization framework for the autonomous design of programmable slender structures. Leveraging the Cosserat rod representation, the end-to-end differentiable framework is demonstrated on two case studies: (i) design of swellable stents that morph to the shape of carotid vessels; (ii) co-design of the remnant magnetization and the applied field of magnetically-active catheters to reduce the force exerted on the patient-specific vessel wall during insertion. Both self-contact and external contact with surrounding structures are accounted for. We consider two actuation mechanism, namely the swelling of gel-elastomer composites and the magnetic actuation of hard-magnetic composites. The proposed framework presents an autonomous design platform of soft slender material systems that support large deformations and multiphysics actuation toward personalized biomedical design.

0.25

Towards Vacuum-Assisted Robotic Needle Interventions: From Fluid Aspiration to Tissue Biopsy

cs.RO ·2026-11-18 ·Sheena Shabana, Laxmi Nag Laxminarayan Nagesh, Marta Vallejo, Karen Donaldson, Maria Koskinopoulou
similarity 0.46
Abstract · 8 pages, 8 figures, Submitted to the 2027 IEEE International Conference on Robotics and Automation (ICRA)

Robotic ultrasound-guided needle interventions have primarily focused on target localization and accurate needle placement, while the subsequent acquisition of diagnostic material remains comparatively underexplored. Moreover, pleural fluid aspiration and tissue biopsy are typically addressed as separate procedures, despite sharing common requirements for ultrasound guidance, safe access, and sample transport. This work presents a unified robotic framework for ultrasound-guided fluid and tissue extraction using a single vacuum-assisted end effector. The proposed system combines force controlled ultrasound scanning, semantic target identification, automated needle deployment, and procedure specific material acquisition. A coaxial needle assembly and shared pump assisted pathway enable direct pleural fluid aspiration, while controlled cannula actuation provides the additional cutting action required for solid-tissue acquisition. End-to-end evaluation using a Franka Emika Panda robot over 50 phantom trials achieved successful extraction in 23/25 pleural fluid aspiration trials (92\%) and 22/25 tissue acquisition trials (88\%). Following successful tissue-target access, acquisition and transport were completed in all 22 trials.

0.32

Respiratory Mask Testing: Airway Inertance and System Dynamics

eess.SY physics.bio-ph ·2026-10-03 ·Mark M. Koeroghlian, Suraj Pawar, Raul G. Longoria
unusual similarity 0.45
Abstract

Life support equipment coupled to the human lungs forms a complex, nonlinear dynamic system. Current respiratory mask test standards rely on sinusoidal breathing machines and surrogate trachea geometries that substantially reduce physiologically relevant airway inertance. This paper shows that the ISO 16900-5 trachea does not generate physiologically meaningful exhalation momentum, limiting the ability of standard test configurations to reveal valve dynamics relevant to human use. A physiologically motivated ``lip-nozzle'' surrogate is introduced as a diagnostic tool to restore realistic momentum transfer, enabling observation of exhalation behavior that is not observable under existing test conditions. Nonlinear dynamic simulations incorporating this surrogate reveal a force-balanced operating regime in which exhalation-jet momentum can offset flow-induced valve resistance, in one representative case reversing exhalation mean effective pressure from resistive to assistive. This effect depends on the relationship between the valve's restoring force and lift, representing a design consideration relevant to future valve development. Implications for mask design, valve placement, and future test methods are discussed. This work does not propose new performance limits or acceptance criteria; rather, it demonstrates how current test fixtures suppress inertance- and momentum-driven effects that can materially influence exhalation valve dynamics.

0.26

Coverage Planning for Robotic Tooth Preparation in Densely Constrained Environments

cs.RO ·2026-08-25 ·Yunwen Li, Chen Chen, Xiangjie Yan, Chang Shu, Jianxia Hou +2 more
similarity 0.44
Abstract

Tooth preparation refers to the controlled removal of tooth structure to create an optimal substrate for fixed restorations and is a core procedure in restorative dentistry. Automating this task is particularly challenging for robots because the dental bur must operate within a densely constrained intraoral workspace, where even sub-millimeter deviations can compromise outcomes or damage adjacent structures. This paper presents a novel robotic system for autonomous full-crown tooth preparation. The proposed framework includes: 1) an anatomy-aware toolpath planning algorithm that conforms precisely to a technician-designed preparation model while protecting adjacent teeth, and 2) a clearance-oriented end-effector yaw assignment strategy that allows intraoral access while reducing the risk of soft-tissue interference. Together, these features enable the robot to accurately mill the irregular tooth surface with an average geometric deviation of 0.117 mm (RMSE), achieving both restoration quality and clinical safety. A series of simulations and phantom-head experiments validate the system's feasibility and effectiveness.

0.26

Humanoids for Robot-Assisted Surgery: Bimanual Base Placement and Tool-Mount Optimization via Capability Maps

cs.RO ·2026-09-27 ·Peihan Zhang, Zekai Liang, Florian Richter, Nikita Thareja, Ryan Broderick +2 more
similarity 0.42
Abstract

Rapid advances in humanoid robotics have motivated growing interest in the application of humanoids for healthcare and clinical tasks. However, it remains unclear how close contemporary humanoids are to meeting the kinematic demands of robot-assisted laparoscopic surgery. In this work, we address the question of optimal robot positioning through a quantitative analysis of workspace and robot setup configurations. We present a capability-map-based robot setup framework that optimizes humanoid base placement and tool mounting orientation to maximize bimanual humanoid reachability while accounting for tool-tip kinematics and remote-center-of-motion (RCM) constraints. We evaluate three humanoid platforms spanning different body dimensions and kinematic redundancy on workspace reachability for three representative general surgery procedures: cholecystectomy, inguinal hernia repair, and sleeve gastrectomy. The proposed joint optimization of base placement and tool mounting consistently outperforms base-only optimization and heuristic baselines. For cholecystectomy and inguinal hernia repair, which are characterized by relatively small and minimally overlapping workspaces, humanoid reachability approached 90%. For the larger, overlapping multi-port arm workspace of sleeve gastrectomy, humanoids yield substantially lower coverage. These results quantify the near-term promise of humanoids for selected laparoscopic procedures and clarify key limitations that must be addressed for broader deployment.

0.36

Towards end-to-end co-design for one-shot printable task-specific soft robots

cs.RO ·2026-11-02 ·James Wood, André Farinha, Will Browne, Josh Pinskier, Krishna Manaswi Digumarti
similarity 0.42
Abstract

Soft robot co-design methods can jointly optimise morphology and control, but the resulting designs are often difficult to manufacture, while manufacturable approaches typically restrict actuator placement or require manual assembly. We present a simulation-based co-design framework that jointly optimises material distribution, pneumatic actuator placement and orientation, and control, while producing designs that can be fabricated monolithically using fused deposition modelling. The framework uses a differentiable 2D plane-stress Material Point Method simulator, incorporating an experimentally validated material model and an empirically derived surrogate model of a 3D-printed inflatable actuator. We demonstrate gradient-based optimisation soft robotic arms for prescribed tip trajectories. Optimised designs are transferred directly from simulation to one-shot monolithic FDM fabrication, with integrated actuators and no post-assembly. Physical experiments demonstrate that the resulting arms reproduce the behaviour predicted in simulation. This framework provides a path from task-level objectives to physically realisable soft robots while retaining substantial freedom over both morphology and actuation.

0.14

Anatomy-Aware Dexterity-Driven Design Optimization of Surgical Continuum Robots

cs.RO cs.AI ·2026-09-25 ·Tony Qin, Peter Connor, Khoa Dang, Carter Hatch, Caleb Rucker +2 more
similarity 0.42
Abstract

Performing complex medical procedures with continuum robots requires careful selection of their geometric design parameters. The robot should have high dexterity in the specific anatomical environment of its procedure. This work presents a design optimization method that considers both dexterity and anatomy. We introduce the Reachable Volumetric Dexterous Solid Angle (RVDSA) metric as our objective, which measures the ability of a robot's end effector to reach the points in a goal volume from different directions via collision-free paths from a start configuration. We present a computationally efficient motion planner to compute this objective function for a given robotic design, and we use an asymptotically optimal simulated annealing optimizer to compute an optimized design. We applied our new method to optimize the design of a bimanual dexterous sheaths robot for performing procedures on cancerous polyps in colon anatomies, achieving a 78% higher RVDSA on average than optimizing for 3D voxel coverage alone.

0.31