CS Paper Radar

Multi-Sensor Edge Angle Detection for Performance Analysis in Ski Jumping

Ivan Simeonov, Lukas Schulthess, Hanna Mueller, Marc Nölke, Michele Magno, Luca Benini, Christoph Leitner

eess.SP eess.SY ·submitted 2026-08-18 07:30 UTC · v1
published

Abstract

In ski jumping, performance during the gliding phase depends on achieving an aerodynamic posture that maximizes the lift-to-drag ratio. In the V-style technique, the ski edge angle is a key determinant. Reducing the edge angle flattens the skis, increases their effective surface area, and improves aerodynamic lift, ultimately contributing to longer flight distances. Ski edge angles are biomechanically constrained by the limited range of ankle inversion. Current sensing solutions widely quantify these angles using multi-system approaches that combine sensor signals through geometric relations. Such configurations require instrumentation on both the boot and the ski, altering mass distribution, affecting balance during flight, and increasing system complexity. To overcome these limitations, this work presents a wearable sensing system that measures both boot inclination and ski edge angle without modifying the ski surface. Two ultrasonic Time of Flight (ToF) sensors and an in-shoe Inertial Measurement Unit (IMU) are integrated into a single boot-mounted unit. Edge angles are estimated by combining ultrasonic distance measurements with IMU data through geometric reconstruction of the boot-ski configuration. Laboratory experiments demonstrate an angle resolution of 0.4500°, a Mean Absolute Error (MAE) of 0.2640°, and a coefficient of determination exceeding 99\% when compared with reference measurements, indicating strong linear agreement between the two modalities. The system achieves an end-to-end latency of 30.31 ms, enabling real-time feedback suitable for athlete training, while consuming 1.28 mW of power. With a total weight of only 18.6 g the proposed system enables unobtrusive measurement of ski edge angle and boot orientation.

DOI
10.1109/JSEN.2026.3725626

Closest papers

Nearest neighbours by meaning across the whole index.

A Unified Kinematic Representation Enables Reusable Biological Joint Moment Estimation

cs.RO ·2026-10-06 ·Jinwoo Hwang, Ilseung Park, Changseob Song, Vu Phan, Eni Halilaj +1 more
code/data similarity 0.56
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

Objective: Data-driven models that estimate physiological states, particularly biological joint moments, are widely used in exoskeleton control. However, these estimators are often coupled to device-specific sensor configurations, limiting controller transfer and the use of open-source biomechanics datasets. Methods: We proposed joint kinematics as an intermediate representation that decouples hardware-specific sensing from downstream biological joint moment estimation. A joint-moment estimator using joint angles and angular velocities was trained exclusively on open-source biomechanics data and evaluated using kinematics from a hip exoskeleton, knee exoskeleton, and inertial measurement unit (IMU) sensor suite during level-ground, ramp-ascent, and ramp-descent walking. Results: The estimator achieved an root mean square error (RMSE) of 0.17 Nm/kg and coefficient of determination (R2) of 0.79 using hip exoskeleton kinematics, 0.19 Nm/kg and 0.62 using knee exoskeleton kinematics, and 0.15 Nm/kg and 0.85 using kinematics derived from IMUs across bilateral hip, knee, and ankle joints. Conclusion: Joint kinematics enabled an estimator trained only on open-source data to operate across distinct wearable platforms. Significance: This framework may reduce target-device data collection and support transferable biological joint moment estimation for exoskeleton control and wearable biomechanics.

0.47

Toward Motion Capture Textiles: A Batteryless IMU Array Powered and Networked Through a Conductive-Fabric Bus

eess.SP cs.NI ·2026-10-14 ·Ryusei Miyakawa, Akihito Noda
published similarity 0.55
Abstract · 4 pages, 4 figures, 1 table. Accepted for publication in IEEE Sensors Letters

Motion capture is increasingly important in healthcare, rehabilitation, and sports applications. However, conventional vision-based systems require camera infrastructure and line-of-sight conditions, limiting their use in daily environments. This paper proposes a location-independent platform for motion capture, based on an array of IMU (inertial measurement unit) sensor nodes without individual wiring or onboard batteries, enabled by two-dimensional communication and power delivery over conductive fabric. Pipeline processing in each sensor node, combined with a token-passing protocol, enables collision-free and stable data acquisition at 50 Hz. Real-time three-dimensional reconstruction of flexible objects is further demonstrated by applying Hermite spline interpolation to orientation data from grid-aligned IMUs. Against a cylinder of known radius, the reconstructed surface deviates by 2.60 mm RMS over the 225 mm span of the array. The reconstruction is formulated for the quasi-static regime, and this letter empirically validates it in that regime. The hardware platform and communication protocol implemented in this work enable further investigation toward dynamic motion capture textiles.

0.35

Knit-Structure Effects on Electromechanical Metrics and Their Correlation with Joint-Angle Estimation Error in Knitted Strain Sensors

cs.HC ·2026-10-05 ·Annika Eloranta, Zhuchenyang Liu, Iiro Naulapaa, Iida Arvola, Yao Zhang +3 more
similarity 0.54
Abstract · 10 pages

Knitted resistive strain sensors show strong promise for joint motion sensing in sports and rehabilitation, but the linkage between sensor design and in situ performance remains unclear. We investigate how knit structure and machine settings (e.g., stitch size) shape electromechanical properties and which metrics predict sensing performance during bending. Sensors spanning seven common knit structures at two stitch sizes were fabricated, characterized under uniaxial cyclic tension, and evaluated on a joint emulating bending rig. Joint-angle estimation was assessed with machine learning models, and correlations with electromechanical metrics were analyzed. Experimental results show that, among six common metrics, gauge factor and baseline resistance are largely set by knit structure, while working range, linear range, hysteresis, and cyclic stability vary only modestly across designs. Gauge factor correlates negatively and baseline resistance positively with joint-angle estimation error, mainly in lower-sensitivity designs, whereas the other metrics have weak or no predictive value. These results support using uniaxial tensile tests to screen out weak designs, while underscoring the need for joint-relevant evaluation and application-specific metrics to identify top performers.

0.40

Calibration-free IMU-based Relative Orientation Estimation under Dynamic Human Motion

cs.RO eess.SY ·2026-10-22 ·Ruiyuan Li, Hassan Osman, Ajay Seth, Manon Kok
similarity 0.52
Abstract · 8 pages, 7 figures, 1 table. Submitted to IEEE Sensors Journal

Recent magnetometer-free inertial measurement unit (IMU) methods can reduce drift in joint motion estimation using rigid-body constraints, but they typically require pre-calibrated sensor locations, assumptions of specific joint models (e.g., hinge joints) or limited motion types, or an external reference for global orientation. Furthermore, challenges related to high-frequency impacts (e.g. at foot strikes during gait) and numerical differentiation of noisy measurements have not been explicitly addressed. We propose an extended Kalman filter that estimates relative IMU orientation and sensor location simultaneously, requiring neither offline sensor location calibration nor a global orientation anchor. A systematic simulation study shows that the quality of the relative orientation and the sensor location estimates depends on different motion-intensity sources: the joint center acceleration and the relative angular velocity, respectively. A low-pass filter (LPF) is used to mitigate real-signal outliers before applying the rigid-body constraint. When applied to the OpenSense dataset with real IMU measurements across four subjects with three lower-body joint types during walking and complex tasks including various motion types, the proposed method achieves an overall relative orientation error of 2.61°, compared with 10.40° for a baseline using offline-estimated sensor locations and 7.43° for a baseline using marker-derived sensor locations. These results show that the proposed calibration-free estimation framework handles real IMU data effectively and achieves accurate relative orientation without offline sensor location calibration.

0.16

Tread: A Visuo-Inertial Framework for Terrain and Locomotion Context-Aware Gait-Phase and Speed Estimation in Wearable Robotics

cs.RO ·2026-10-13 ·Debadrata Sarkar, Akash Bachhar, Aman Arora
similarity 0.52
Abstract · Supplementary video: A video demonstrating real-time operation of the complete visuo-inertial inference pipeline is available at https://doi…

A wearable assistive robot must continuously estimate terrain, locomotion mode, gait phase, and walking speed. These quantities are commonly addressed by separate, terrain-specific models, with datasets rarely collected under a common protocol. This paper presents a visuo-inertial framework that connects these estimates through a causal pipeline using a chest-mounted camera and four lower-limb inertial measurement units (IMUs). Anticipatory Terrain Perception (ATP) classifies incoming terrain with 96.3% accuracy and anticipates terrain transitions by 1.46 s on average. Terrain-Aware Locomotion Mode Identification (TALMI) achieves 93.7% and 98.8% accuracy for its level-ground and stairs experts respectively, with mean transition latencies being below 200 ms. The relevant TALMI posterior is retained as a Probabilistic Locomotion Context (PLC) vector and provided to a shared Gait Kinematic Encoder (GKE), which supports 50-Hz bilateral gait-phase estimation and 2-Hz walking-speed estimation. Leave-one-subject-out evaluation yields gait-phase RMSEs of 1.75%, 2.97%, and 4.55% for level walking, stair ascent, and stair descent respectively while estimating speed over 3.5-5.5 km/h with a RMSE of 0.218 km/h. All inertial sensing based models use sensor-fused Euler angles as input rather than raw accelerometer and gyroscope signals, reducing dependence on sensor mounting variation.

0.26

A2I-Calib++: A Kinematics-Driven Anti-noise Active Calibration Framework for Whole-Body Multi-IMU Systems on Legged Robots

cs.RO ·2026-10-21 ·Fangyu Jiang, Chaoran Xiong, Kehui Ma, Zhen Sun, Zeyu Zhang +1 more
similarity 0.51
Abstract

Recently, multi-node inertial measurement unit (multi-IMU) systems have shown promise for robust odometry in legged robots. Multi-IMU fusion can improve legged robot odometry but requires accurate spatiotemporal calibration among the sensors. Existing multi-IMU calibration methods, designed for aerial or handheld platforms, face challenges on legged robots because routine locomotion may provide insufficient excitation, while foot slips, impacts, and vibrations introduce measurement disturbances. To address these challenges, we propose A2I-Calib++, a kinematics-driven anti-noise active calibration framework for body-mounted IMUs covered by the robot kinematic model. It estimates temporal offsets, extrinsic rotations and translations, and inertial biases through temporal correlation search followed by analytic spatial and bias estimation, without artificial calibration targets or complex parameter tuning for the target IMU. A2I-Calib++ comprises three core modules: 1) a Noise-Isotropy-Inspired Trajectory supported by a finite-horizon conditioning proposition that generates sufficient excitation to limit noise sensitivity; 2) a constraint-aware Adversarial Motion Priors controller that combines the anti-noise excitation with a rolling-contact reward for contact-aware execution; and 3) a contact-constrained virtual IMU that fuses pre-calibrated calf IMUs and joint kinematics under a rolling-contact model to construct the calibration reference. Furthermore, evaluations on both simulation and real-world quadruped platforms demonstrate notably reduced noise sensitivity and simulation calibration errors compared to conventional methods, together with repeatable real-world calibration and improved proprioceptive odometry accuracy for legged robots.

0.16

SG-ODOM: Event-Driven Proprioceptive State Estimation with Stability-Gated Contact Updates for Legged Robots

cs.RO ·2026-11-16 ·Francesco Iotti, Chiyun Noh, Franco Angelini, Manolo Garabini, Ayoung Kim +2 more
code/data similarity 0.51
Abstract

Reliable proprioceptive state estimation for legged robots fuses inertial sensing with kinematic sensing from leg encoders. The latter assumes a foot is stationary during the stance phase; however, physical foot touchdown does not necessarily provide a stationary reference for odometry, particularly during impact and load transfer. Repeatedly applying kinematic corrections throughout the same contact phase can introduce redundant or unreliable information. We present SG-ODOM, a proprioceptive odometry framework that uses stability-gated contact selection to schedule kinematic updates. Following physical touchdown, a stability gate accepts the contact for state estimation only after the foot reaches a sufficiently stable support condition. The resulting validated touchdown event triggers an estimator correction, while additional timeout updates bound the maximum duration of uninterrupted IMU propagation. The framework is evaluated on multiple legged platforms, both quadrupedal and humanoid robots, against representative state-of-the-art proprioceptive estimators. Across the evaluated sequences, SG-ODOM demonstrates competitive or superior estimation accuracy, reducing Relative Pose Error (RPE) by up to 25% compared to the baseline estimator on outdoor sequences from the GrandTour dataset. Source code: https://github.com/ori-drs/SG-ODOM. Video: https://youtu.be/-583_RyuhqQ

0.39

Rotation-Invariant Multi-IMU Activity Recognition under Independent Per-Location Orientation Shifts

cs.AI cs.LG ·2026-08-16 ·Seungyeol Baek, Yoonbyung Chai, Yonghyeon Lee, Sungjoon Choi, Sungho Suh
published similarity 0.51
Abstract · 6 pages, 2 figures. ACM International Symposium on Wearable Computing (ISWC) 2026

Human Activity Recognition (HAR) with self-administered wearables, such as at-home rehabilitation and exercise monitoring, often requires reattaching inertial measurement units (IMUs) across sessions. In multi-IMU settings, this can induce independent orientation offsets across body locations, a deployment shift that conventional scalar HAR models do not structurally handle. Existing remedies rely on rotation augmentation, whose robustness depends on sampled transformations, or calibration and orientationnormalization pipelines requiring additional reference-frame assumptions or explicit procedures. We present Truly Rotation-Invariant HAR (TRI-HAR), a rotation-invariant framework that makes robustness to independent per-location IMU orientation offsets a structural model property. TRI-HAR reshapes accelerometer and gyroscope streams into triaxial vectors, applies a shared SO(3)-equivariant backbone and invariant projection to each IMU location, and fuses the resulting invariant features for activity classification. Across four multi-IMU benchmarks, TRI-HAR preserves macro-F1 under fixed independent per-location SO(3) rotations and outperforms rotation-augmented baselines under this target shift without requiring rotational augmentation.

0.58