CS Paper Radar

A scattering correction method for CT reconstruction based on the Wavelet Adaptive Material-dependent Boltzmann Transport Equation (WAM-BTE)

Huiying Pan, Xu Jiang, Xing Zhao

eess.IV physics.med-ph ·submitted 2026-08-22 09:12 UTC · v1
unusual

Abstract

X-ray computed tomography (CT) is an essential imaging technology in clinical diagnosis. However, scattered photons can reduce image contrast and introduce CT value bias, which severely degrades image quality. Recently, scatter correction methods based on the Boltzmann transport equation (BTE) have attracted increasing attention due to their high physical accuracy and flexibility. Nevertheless, existing BTE-based methods usually employ single-material models, which cannot accurately describe the nonlinear energy dependence of photon interaction cross-sections in different materials. In this work, a scatter correction method based on the wavelet adaptive material-dependent BTE (WAM-BTE) is proposed. The conventional single-material model is extended to a multi-material model by introducing material-dependent scattering distributions. Furthermore, an adaptive multi-scale framework is established through wavelet decomposition. The low-frequency wavelet coefficients are used for coarse-scale scatter estimation to reduce computational complexity, while the high-frequency wavelet energy of high attenuation materials is utilized for adaptive local refinement. Theoretical analysis demonstrates that, when using the Haar basis function, the low-frequency wavelet coefficients at the $w$-th level are mathematically equivalent to block-average downsampling with a scale factor of $2^w$, except for a deterministic normalization factor. Experimental results show that the proposed WAM-BTE method achieves comparable accuracy to the Monte Carlo method while preserving the computational efficiency of coarse-scale estimation. The scatter calculation time for a single projection view is reduced to the millisecond level.

Closest papers

Nearest neighbours by meaning across the whole index.

SpectralCTGaussians: Projection-Domain Reconstruction and Basis Material Decomposition for Spectral CT using 3D Gaussian Splatting

cs.CV ·2026-08-29 ·Reinout Vos, Saptarshi Neil Sinha, Michael Weinmann
similarity 0.60
Abstract

Spectral computed tomography (CT) extends conventional CT by measuring attenuation across multiple energy channels, allowing improved modeling of physical X-ray interactions and energy-dependent material behavior and leading to richer scene understanding. We present a novel method for spectral CT reconstruction and basis material decomposition using 3D Gaussian Splatting by adding per-Gaussian basis material fractions to the set of learnable parameters, which together with a set of energy-dependent basis functions define the attenuation across the full spectral range. The basis functions represent various physical attenuation models such as photoelectric absorption and Compton scattering, and are jointly optimized across all energy channels through a differentiable polychromatic forward model, with material decomposition performed via mean-shift clustering of the resulting coefficients. We evaluate our method on a baseline real-world dataset as well as a synthetic dataset that we introduce, comparing against traditional reconstruction algorithms and state-of-the-art learning-based CT reconstruction methods. Our approach outperforms all traditional baselines in novel view synthesis and achieves the best PSNR among all compared methods for spectral CT volume reconstruction, while describing all energy channels with a single shared representation that requires a number of Gaussians comparable to single-channel Gaussian splatting-based CT reconstruction approaches. For basis material decomposition, no traditional or learning-based baseline offers one-step decomposition with direct RGB material segmentation, and our method additionally recovers the photoelectric basis with higher PSNR than traditional pipelines.

0.24

Gaussian Material Fields for Volumetric Multi-Energy CT Decomposition

cs.CV ·2026-10-07 ·Jian Lin, Jiancheng Fang, Hongming Shan, Shaoyu Wang, Yang Chen +1 more
similarity 0.56
Abstract · 13 pages, 12 figures

Volumetric material decomposition in multi-energy computed tomography requires a representation that organizes multiple three-dimensional material fields in a common spatial domain while retaining differences in composition and local structure. We observe that spatial primitives can be shared across materials without tying their coefficients, but their local capacity must respond to material-specific reconstruction needs. We introduce Gaussian material fields, which represent multiple material distributions with shared anisotropic 3D Gaussian primitives and independent nonnegative material coefficients. The shared geometry defines a continuous spatial basis, while the coefficients determine each primitive's contribution to the individual material fields. To reconstruct this representation from multi-energy projections, a differentiable spectral forward model combines Gaussian material path integrals with a calibrated basis matrix, enabling joint optimization of spatial geometry and material composition. Material-aware adaptive density control retains material-specific refinement evidence before aggregation and adjusts local representation capacity to accommodate both spatially extensive components and sparse details. Experiments use synthesized multi-energy projections generated from pseudo-reference material maps constructed by conventional methods from publicly available CT data. Across 15 cases, our approach improves average PSNR by 4.03 dB and SSIM by 4.96% over the strongest baseline, while reducing NRMSE by 33.45%. Material-wise comparisons and component ablations support improved recovery of localized structures, while runtime and memory measurements show favorable computational scaling. These results establish Gaussian material fields as an explicit, adaptive representation for volumetric multi-material reconstruction.

0.27

Unified Projection-Domain Material Decomposition for Energy-Integrating and Photon-Counting CT

eess.IV physics.med-ph ·2026-10-21 ·Dale Black, Surya Naidu, Hamidreza Khodajou-Chokami, Sabee Molloi
theory similarity 0.52
Abstract · 27 pages, 10 figures, 6 tables

Objective: To develop a unified and efficient method for projection-domain material decomposition in spectral computed tomography (CT) that incorporates an arbitrary number of spectral measurements, independent of the acquisition mechanism, without reducing the measurements to two effective energies. Approach: A nested optimization method was developed for two-material basis decomposition from K>=2 spectral measurements. It extends an existing two-measurement univariate method by replacing its polynomial approximation with profile minimization of the Poisson negative log-likelihood, reducing the inversion to two one-dimensional searches that use all measurements without spectral rebinning. The method was evaluated in simulation for energy-integrating (GE Revolution Apex Elite, Siemens SOMATOM Flash) and photon-counting (Siemens NAEOTOM Alpha) CT. Main results: The method recovered line integrals with noiseless iodine errors below 3e-6 g/cm^2 and noise within 3% of the Cramer-Rao lower bound (CRLB). Virtual monoenergetic images (VMIs) agreed, at 70 keV and above, with reference CT numbers and, on all three systems, with vendor VMIs of physical scans (mean absolute error 6-22 HU). For photon counting, four measurements instead of two reduced the iodine CRLB by 19% and image noise by 8-16% at every VMI energy, and lowered the regression error at 70 keV and above. Iteration and tolerance settings changed CT numbers by less than 0.04 HU, and decomposition took 0.34-0.67 s per million rays on an A100 GPU. Significance: The method provides fast, accurate decomposition for any spectral CT acquisition mechanism and number of measurements, so one method can serve every scanner in a virtual imaging trial.

0.25

Toward a Foundation Plug-and-Play Prior for Computed Tomography Reconstruction via a Multimodal Diffusion Model

cs.CV ·2026-08-24 ·Haley Duba-Sullivan, Patxi Fernandez-Zelaia, Obaidullah Rahman, Amirkoushyar Ziabari
published similarity 0.52
Abstract · To appear in SC26 Workshops proceedings

Computed tomography (CT) throughput is limited by scan time, which grows with both the number of projections acquired and the detector integration time for each projection. Reconstructing high-quality volumes from sparse-view or low-dose measurements therefore depends on using an informative prior, typically a neural network trained for one specific scan setting and retrained whenever the modality, geometry, or material changes. We investigate whether a single diffusion model trained across several imaging domains can instead serve as a reusable prior for heterogeneous CT reconstruction problems. We evaluate the proposed method using the same diffusion visual transformer model and normalized denoising strength on three datasets that differ in modality, beam geometry, material, and degradation type, spanning additively manufactured metal parts and concrete microstructure imaged with cone-bean X-ray CT and parallel-beam neutron CT respectively. The proposed method improves upon analytic reconstructions in all three cases, demonstrating transferability across the evaluated problems and providing a step toward a reusable foundation prior for heterogeneous CT reconstruction.

0.25

Feed-Forward Hierarchical Gaussian Diffusion for Extreme CT Reconstruction

cs.CV ·2026-08-15 ·Yuezhe Yang, Li Cheng
benchmarkcode/data similarity 0.50
Abstract

Reconstructing three-dimensional computed tomography (CT) from severely constrained projections is highly ill-posed. Sparse angular sampling, restricted angular coverage, and low photon counts can occur individually or jointly, obscuring global anatomy and local tissue detail. Many learned CT reconstruction methods are tailored to a single dominant degradation. Existing diffusion and Gaussian approaches commonly recover global structure and local detail within a shared representation. We propose HiGDiff, a feed-forward hierarchical Gaussian diffusion framework that decomposes reconstruction both spatially and from structure to detail. Physics-conditioned anatomical anchors and a foreground capacity field allocate learnable Gaussian primitives to informative regions. A structure diffusion stage first recovers global attenuation geometry, and its learned representation conditions a detail diffusion stage for residual boundaries and tissue transitions. The resulting Gaussian banks are rendered as attenuation fields and further refined by a gradient-isolated residual module. Experiments on three distinct CT benchmark datasets demonstrate state-of-the-art reconstruction performance across isolated, paired, and joint degradation settings, including improvements of 5.81 dB in macro-average peak signal-to-noise ratio (PSNR) and 0.113 in structural similarity index measure (SSIM) on the Low Dose CT Image and Projection Data (LDCT-PD) collection. Code and experimental configurations are openly available at https://github.com/Bean-Young/HiGDiff.

0.24

Image-Condition-Controlled Diffusion Network with Large-Scale CT Pretraining for CT-Free Attenuation Correction in Dynamic Cardiac PET

cs.CV ·2026-11-18 ·Zhejia Zhang, Scott M. Leonard, Jinkui Hao, Ryan J. Avery, Richard L. Weinberg +1 more
similarity 0.50
Abstract · 11 pages, 6 figures, 3 tables. Submitted to IEEE Transactions on Radiation and Plasma Medical Sciences

Positron emission tomography (PET) provides quantitative information on myocardial perfusion. In dynamic PET, tracer kinetics are tracked through a series of reconstructed time frames. Reliable attenuation correction is essential for accurate measurements. Clinical attenuation maps ($μ$-maps) are typically derived from computed tomography (CT), which adds radiation exposure and may introduce PET-CT misregistration due to respiratory and cardiac motion. Moreover, supervised CT-free methods rely on paired non-attenuation-corrected (NAC) PET and CT data, which are scarce, whereas large-scale unpaired CT data are more readily available. To address these challenges, we propose Large-scale Unpaired CT-Informed Diffusion (LUCID), a framework that transfers anatomical priors learned from 10,000 chest CT volumes in the public CT-RATE dataset to $μ$-map synthesis for dynamic cardiac $^{82}$Rb PET. First, a convolutional neural network (CNN) predicts an initial $μ$-map from each NAC PET frame. Second, the CT-pretrained diffusion backbone refines a low-noise perturbation of the CNN prediction through a single denoising step, conditioned on the corresponding NAC PET frame via ControlNet. Finally, frame-wise predictions are averaged voxel-wise to obtain the final $μ$-map. We further introduce the voxel-wise temporal standard deviation (TSD) to quantify inter-frame variability without requiring a reference $μ$-map. We evaluated LUCID on an in-house dataset of 102 patients and found that it achieved the best quantitative accuracy while maintaining competitive inter-frame consistency. Ablation studies showed that refinement with a diffusion backbone pretrained on in-house CT data from the training patients was less accurate than the CNN prediction alone, highlighting the importance of large-scale CT pretraining.

0.21

Enhancing analytical photon transport in turbid media through physics-guided neural network corrections

cs.AI physics.optics ·2026-10-17 ·Guojun Tang, Paul D. Teal, Alexander Doronin
similarity 0.49
Abstract · 6 pages, 4 figures

Analytical methods provide rapid and computationally efficient predictions of light transport in turbid media, making them attractive for real-time and inverse applications. However, their accuracy is limited by the approximations and assumptions used to obtain tractable solutions. On the other hand, Monte Carlo (MC) simulation is widely regarded as the "gold standard" for modeling light transport in turbid media, but its high computational cost limits its use in applications requiring repeated forward evaluations. Here, we introduce a physics-guided residual learning framework that combines the computational efficiency of analytical modeling with the accuracy of MC simulation. As a representative case study, we consider the diffusion approximation (DA), which can exhibit systematic errors under relatively strong absorption, weak scattering, and imperfect boundary treatment. Given the absorption coefficient, scattering coefficient, and anisotropy factor, the corresponding DA prediction is incorporated as a physical prior, while the network learns only the residual between the analytical prediction and the MC reference. Across the evaluated optical-property range, the proposed framework reduces scalar-reflectance RMSE and spatially resolved reflectance RMSLE by factors of approximately 62 and 14, respectively, relative to the diffusion approximation. With only 1\% of the available training data, it achieves approximately 87\% and 93\% lower corresponding errors than a direct neural-network surrogate. These results demonstrate that learning corrections to an analytical physical baseline improves both prediction accuracy and data efficiency.

0.11

Bayesian Joint Reconstruction and Uncertainty Quantification for Limited-Data Multi-Contrast X-Ray CT

eess.IV physics.optics ·2026-10-15 ·Hassan Yazdanian, Henrik Mäkinen
similarity 0.49
Abstract

Multi-contrast X-ray computed tomography (CT) combines attenuation contrast with phase and dark-field contrast, which are sensitive to refraction and ultra-small-angle scattering, respectively. Common implementations record several intensity measurements per projection angle by phase or mask stepping, which lengthens acquisition and, at a fixed exposure per measurement, raises the dose. Limited-data acquisition via sparse angular sampling or reduced stepping lowers these costs but makes the data less informative, calling for prior information and uncertainty quantification. We study joint Bayesian reconstruction of attenuation, phase, and dark-field images from separately retrieved sinograms. A joint total variation term in the prior couples edge locations across the images but not their values. Posterior sampling with the No-U-Turn Sampler complements maximum a posteriori estimates with pixel-wise uncertainty. We compare this joint prior with channel-wise total variation alone on synthetic and experimental Talbot-Lau interferometry data under full, sparse-angle, sparse-step, and combined acquisition (up to 24 times fewer exposures). Both maximum a posteriori reconstructions suppressed undersampling artifacts, with synthetic relative errors 1.6-11 times lower than those of filtered backprojection. The joint prior gave modest synthetic accuracy gains, a cleaner experimental dark-field background, 23-30 % lower mean dark-field posterior standard deviation, and 4-38% higher median effective sample size in experimental limited-data runs. In the synthetic study, posterior standard deviations matched or exceeded the errors in flat regions but underestimated them at boundaries, especially in phase. Experimental phase chains mixed slowly under angular undersampling. The formulation also applies to edge illumination with adapted forward and noise models.

0.20