CS Paper Radar

Design and Experimental Validation of a 3D Printed Torsional Series Elastic Actuator for Safe Human Robot Interaction

Joel Hidalgo Pisco, Melissa Cobos Condo, Luigi Miranda, Dennys Paillacho

cs.RO ·submitted 2026-09-16 19:42 UTC · v1
published

Abstract

Ensuring intrinsic safety in physical human robot interaction (pHRI) is a critical requirement for social and service robots. While Series Elastic Actuators (SEAs) offer hardware based compliance, traditional metallic designs often require complex, multi part assemblies. This paper presents the design, finite element analysis (FEA), and experimental validation of a low stiffness, torsional spring for SEAs, manufactured via 3D printed thermoplastic polyurethane (TPU). The compliant element exhibits a highly linear torque deformation response (Ks = 0.066 Nm/degree), matching numerical predictions with under 3% deviation, a variance attributed to FDM structural anisotropy. To accommodate external interactions using standard position limited servomotors, a hybrid position controller with torque threshold switching was implemented. Experimental evaluations demonstrate the system ability to accurately track non stationary trajectories and safely yield to external disturbances. Furthermore, the inherent material damping of the TPU acts as a passive low pass filter, preventing high frequency oscillations during control mode transitions. The proposed architecture offers a cost effective, reliable, and easily manufacturable solution for safe pHRI.

Closest papers

Nearest neighbours by meaning across the whole index.

A Monolithic Force-Proprioception Soft Acutuator Enabled by Single-Material 3D printing

cs.RO ·2026-09-21 ·Nan Huang, Lele Liu, Junfeng Lu, Yipan Zhu, Jiansheng Dai +1 more
similarity 0.60
Abstract

Pneumatic proprioceptive actuators integrate actuation and sensing for soft robots that attract interest due to functional potential. Existing approaches often suffer from assembly errors or stress concentrations caused by heterogeneous materials. In this work, we propose the Monolithic Force-Proprioception Soft (MFPS) design and fabrication method that integrates an Asymmetric Origami Bending (AOB) chamber and a Force-Proprioception Soft (FPS) sensor with single material through one-step Fused Deposition Modeling (FDM) fabrication. Based on the resistance response to strain of conductive thermoplastic polyurethane (TPU), we design and analyze the structure of the FPS sensor, and conduct parametric analysis on the sensing characteristics. The FDM fabrication parameters of the MFPS actuator are analyzed, followed by actuator fabrication and characterization of the actuation and proprioception performance. Experimental results show that the MFPS actuator achieves a bending angle of 40°, an output force of 12.5 N, and a resistance change of 26.9% as the applied external force increased from 0 to 45 N. A two-finger force-proprioception gripper is developed based on the MFPS actuator. The grasping and force-proprioception capabilities are experimentally validated, proving that the MFPS design method provides a new approach for the development of self-sensing actuators.

0.20

Design and Characterization of a Unified Continuum Robot Actuation Platform

cs.RO ·2026-10-14 ·Yunti Xu, Aedan Mangan, Miheer Potdar, Alex Lu, Tania K. Morimoto
similarity 0.58
Abstract

Continuum robots enable dexterous access to confined spaces in applications such as minimally invasive surgery and industrial inspection. However, their actuation systems are often custom-designed for specific robot architectures and tasks, limiting reuse across publications, institutions, and applications. This paper presents a unified actuation platform that decouples actuation hardware and software from continuum robot design. The platform provides modular actuation across continuum robot classes, scales to a large number of degrees of freedom (DOFs), and integrates with conventional serial manipulators for hybrid architectures. We validate the platform on an open-sourced surgical robotic system and experimentally characterize the actuation modules, achieving sub-millimeter translational accuracy and less than $5^\circ$ rotational error over ranges of $30$~mm and $180^\circ$, respectively. We further demonstrate the platform in two surgical use cases: teleoperation of a continuum camera in a constrained environment and bimanual manipulation using $2.53$~mm concentric-tube-robot-based forceps alongside a conventional wristed instrument. All hardware designs and ROS-based software are open-sourced to facilitate reuse and further research in continuum and surgical robotics.

0.31

Capstan-driven Continuum Surgical Robot: Design, Modeling, and Perception

cs.RO ·2026-08-13 ·Gang Zhang, Yufu Qiu, Junyan Yan, Wenhui Zeng, Wenlong Lu +1 more
similarity 0.58
Abstract

Shape and force sensing have long been critical bottlenecks in the development of compact capstan-driven continuum surgical robots, primarily due to the difficulty of obtaining cable tension information within the confined capstan assembly. To overcome these challenges, this paper presents an integrated design-modeling-sensing approach based on the concept of actuation-perception co-design. A compliant element is introduced into the motor mounting bracket of the drive system, enabling micro-deformation under the cable reaction force and thereby allowing real-time cable tension measurement without occupying the compact capstan space. To address the modeling complexity arising from unconventional joint configurations introduced by the spatial cable routing strategy, a parallel computation framework based on a multibody short-thick-beam model is proposed, which captures shear effects in short beam segments and synergistic multi-cable interactions while achieving real-time performance. Building on this framework, stable shape and force sensing is achieved by incorporating a proximal multi-axis force/torque sensor as an additional measurement anchor. Following this design-modeling-sensing framework, capstan-driven continuum surgical robots with single- and dual-segment configurations are developed. Experimental results validate the proposed framework in both single- and dual-segment continuum robots, demonstrating real-time tip pose estimation together with contact force and location perception. By enabling cable tension feedback without compromising the compact capstan architecture, the proposed framework makes integrated perception feasible for capstan-driven continuum surgical robots.

0.04

Curvature by Design: A Support Structure for Continuum Robots

cs.RO ·2026-11-04 ·Justus Sagemüller, Harald Minde Hansen, Kristin Y. Pettersen
similarity 0.58
Abstract

Constant- and piecewise-constant-curvature models are widely used to simplify the kinematics of continuum robots, although the assumed curvature profiles are not necessarily inherent mechanical properties of the robot and may therefore be violated during operation. Rather than assuming a prescribed curvature profile in the kinematic model and estimating deviations from it, this paper presents a multi-segment scissor-based support structure that mechanically constrains a continuum robot to exhibit prescribed constant or spatially varying curvature profiles. The design uses Taylor approximations to enable an overconstrained multi-joint linkage to predictably distribute global bending among the small-angle movements of multiple flexures. The geometric coupling is realized using compliant flexure joints, enabling the support structure to be manufactured as a single piece. The structure is integrated with a tendon-actuated continuum robot with a flexible backbone. Experiments show that the structure makes the robot resistant to deformations other than the prescribed curvature, significantly enhancing shape precision compared to classical flexible-backbone designs. This constrains the robot from making S-shapes when external loads are applied in the opposite direction of the bending. By mechanically constraining the admissible deformation, the proposed structure reduces the number of independent shape variables that must be estimated.

0.11

Task-space model-based control of pneumatic soft actuators

cs.RO ·2026-08-27 ·Nithin S. Kumar, Joshua Gaston, D. Caleb Rucker, Eric J. Barth
top venue similarity 0.58
Abstract · 11 pages, 14 figures

Soft actuators enable dexterous and compliant interaction, but closed-loop task-space control remains challenging due to strong nonlinearities, distributed deformation, and uncertainty in their dynamics. This paper presents a real-time dynamic-model-based task-space feedback and estimation framework based on a non-minimal coordinate discrete elastic rod model formulated in absolute coordinates with holonomic constraints. The resulting structure preserves distributed mechanics while maintaining computational efficiency through sparse system matrices, enabling real-time control with up to 10 discretized rods. A quasi-static feedforward inverse model is combined with a task-space PI controller and a dynamic observer that fuses measurement residuals as virtual forces, enabling full-state estimation from sparse sensing. The approach is experimentally validated on three planar pneumatic soft actuators with varying geometries. Across five tasks, including drawing the digits 0-9 across the workspace (3-18 mm/s tip speed), tracking periodic motion (up to 37 cm/s), cross-platform generalization, reduced sensing conditions, and real-time user-defined references, our method achieves 1.5-2.3 mm root mean square error (RMSE) for precision motions and 5.5-12.4 mm RMSE at 1-2 Hz. Results demonstrate that structured, non-minimal dynamic models can enable real-time, high-precision, moderate-bandwidth task-space control of planar soft pneumatic actuators in free space.

0.27

Safe Physical Interaction of All-Electric Heavy-Duty Robotic Manipulators via Control Barrier Functions and Variable Impedance Control

cs.RO ·2026-11-16 ·Amir Hossein Barjini, Mohammad Bahari, Jouni Mattila
similarity 0.58
Abstract

All-electric heavy-duty robotic manipulators are increasingly expected to operate close to tunnel walls, equipment, and other structures while retaining the force capability required for large-payload tasks. Accurate motion control alone does not address the resulting safety and interaction requirements. This paper develops a safety-aware physical-interaction architecture that combines variable impedance control (VIC) with control barrier functions (CBFs) on top of an established virtual decomposition control (VDC) framework for electromechanical linear actuator (EMLA)-driven manipulators. VIC continuously adapts the task-space stiffness and damping according to predicted proximity and contact risk, whereas a joint-velocity CBF filter enforces Cartesian workspace boundaries and the physical stroke limits induced by the closed-chain lift and tilt mechanisms. To account for nonideal realization of the filtered velocity by the inner VDC/EMLA dynamics, the CBF inequalities are tightened using a measured bound on the joint-velocity tracking error. Four configurations, namely VDC, VIC+VDC, CBF+VDC, and VIC+CBF+VDC, are evaluated under workspace, actuator-limit, and physical-interaction scenarios. VIC reduces the peak and RMS environment-interaction forces by 92.59% and 96.33%, respectively; both robust CBF configurations maintain positive workspace and EMLA safety margins, while VIC+CBF+VDC reduces the CBF intervention metric by 10.30% compared with CBF+VDC.

0.27

TinyARM-X: A Series of Open-Source, Configurable, and Transparent Torque-Controlled Desktop-Scale Robotic Manipulators

cs.RO ·2026-11-18 ·Nicolas Kosanovic, Jean Chagas Vaz
similarity 0.57
Abstract · 9 pages, 5 figures. Submitted to a robotics Journal. Reviews have not come in yet

Visuomotor policies have demonstrated that imprecise low-cost robots can autonomously complete complex manipulation tasks. However, most inexpensive manipulators rely on compact and rigidly position-controlled servos for actuation, which complicate simulation, operation, and safety. This work introduces TinyARM-X, a framework for easily manufacturable, configurable, and torque-controllable low-cost (<350 USD) serial manipulators. By using a single hardware/software architecture, a <7 Degree of Freedom (DoF) TinyARM can be manually reconfigured to an operational >3 DoF robot within 10 min. Actuator modeling and dynamic compensation enable torque-controlled applications like mixed-reality impedance control teleoperation and simulator force feedback rendering. Experiments include mechanical benchmarking and real-world force-aware telemanipulation. The TinyARM-7 has a payload of 33.5 g, a max speed of 0.77 m/s, and a reach of 210 mm. Moreover, with dynamic compensation, the robot has a backdrive-breakaway force of 1.4 N and a backdrive-running force of 0.7 N. Additionally, Cartesian-Impedance Control (CIC) attains a translational stiffness of >15 N/m. Lastly, the TinyARM-X stack is open-sourced to disseminate accessible desktop-scale torque-controlled robotic manipulation to the community.

0.21

SaddleSense: Saddle-Shaped Modules for 3D Shape Sensing with Single-Axis Off-the-Shelf Bend Sensors

cs.RO ·2026-10-31 ·Dong Heon Han, Runze Zuo, Chankyo Kim, Saima Jamal, Daniel Bruder
similarity 0.57
Abstract

Accurate posture feedback is essential for precise control of continuum robots. Off-the-shelf bend sensors measure curvature about only one axis; without a suitable mounting arrangement, they can restrict robot motion and provide incomplete posture information. SaddleSense introduces a 3D-printed thermoplastic polyurethane (TPU) saddle-shaped lattice that holds one commercial bend sensor along each curved edge. Because each sensor flexes within its own channel rather than spanning the segment axially, the lattice converts multi-axis body deformation into sensor curvature without tying segment length to sensor length. Each four-sensor module accommodates two-axis bending, contraction, and extension while quantifying all three deformation modes across its four readings. A hybrid calibration maps the sensor readings to piecewise constant curvature (PCC) parameters using a learned model paired with a physics-based fallback for out-of-distribution inputs. We demonstrate a six-module prototype with 24 off-the-shelf bend sensors on a 430~mm continuum body. Using only each module's four local readings, the physics-based model alone achieves a tip position root mean square error (RMSE) of 29.9~mm (7.0\% of body length). The data-driven model reduces the tip RMSE to 13.2~mm (3.1\%) on held-out samples of motions similar to the training set and 15.8~mm (3.7\%) on separately recorded trials. Reducing each module from four sensors to one nearly triples the tip error.

0.32