CS Paper Radar

Initialization and Stopping Tolerance in CPU Dermoscopic Segmentation

Wenhao Xu, Yixian Kong, Ting Pan, Feilong Wang, Changwei Wang

cs.CV eess.IV ·submitted 2026-09-22 04:40 UTC · v2
code/dataunusual

Abstract

Contour initialization and numerical stopping can jointly affect the evaluation of active-contour segmentation. We examine their interaction using the open-source scikit-image Chan-Vese implementation on a resized ISIC 2017 mirror. A fixed development set of 100 images selects a common input channel; all 600 images in the repository's held-out partition are then evaluated. Otsu thresholding is compared with checkerboard-, disk-, and Otsu-initialized contours under default and tighter level-set tolerances. At the default tolerance, Otsu initialization increases mean image Dice from 0.6011 to 0.6660 relative to checkerboard initialization, a paired difference of 0.0649 (95% image-bootstrap interval [0.0452, 0.0860]). Otsu thresholding alone achieves 0.6897. The default disk initializer stops after one iteration on 471 images. Tightening the tolerance reduces the Otsu-seed advantage over checkerboard initialization to 0.0197, with most runs reaching the 500-iteration limit. The default-tolerance advantage also reverses between small- and large-lesion strata. These findings show that an improvement over a generic initializer can coexist with deterioration relative to the threshold baseline. Evaluations should retain the unrefined mask as a comparator and report the initial-field definition, stopping tolerance, and observed iteration counts together.

Comment
10 pages, 3 figures, 2 tables

Closest papers

Nearest neighbours by meaning across the whole index.

SWIFT-Cell: Segmentation Without Iterative Flow Tracking

cs.CV ·2026-10-21 ·Devansh Lalwani, Swapnil Bhat, Muralikrishna H H, Anand Reddy, Maulik Shah
unusual similarity 0.54
Abstract

Generalist segmenters such as Cellpose-SAM (CPSAM) outline cells accurately across stains but slowly; watershed detectors such as QuPath's are fast but less accurate. In time-critical use, such as interactive retrieval of cells from a user-drawn region, CPSAM at the reference settings takes 58-303 s per measured 8192 x 8192 region on an RTX 4500 Ada GPU, beyond a seconds-scale interactive target. We distil CPSAM into SWIFT-Cell (SWIFT), a 0.63M-parameter U-Net trained only on CPSAM masks of 1,202 H&E and IHC tiles. On three 8192 x 8192 development regions SWIFT takes 2.0-5.2 s on 4 CPU cores in int8, 2.5-5.1x faster than QuPath's detector on the same cores, and 0.36-0.49 s on a GPU. Against human annotations on eight H&E, IHC and ISH sets it keeps 95% of CPSAM's panoptic quality (PQ) on PanNuke (0.593 vs. 0.627) and is level on NuCLS (0.546 vs. 0.540). On Ki-67 IHC masks scored to the outline centre it is 0.205 PQ above QuPath's better mode, 0.079 below CPSAM and 0.027 below InstanSeg (CI includes 0; at the outer edge 0.008 below CPSAM); on 212 pathologist-outlined nuclei in Ki-67 fields of 12 untouched patients its recall is 0.925 (CPSAM 0.920, InstanSeg 0.901; paired difference CIs include 0); one method-blinded pathologist accepted its outlines in 96% of 100 fields (60 from two development tissue patients, 40 hematology; CPSAM 83%, QuPath 53%; tissue 100% for SWIFT and CPSAM); on ER/PR points from 12 patients its detection F1 is 0.882 (CPSAM 0.896, InstanSeg 0.857), and on 4-reader PD-L1 points 0.83 (CPSAM 0.85, readers 0.87). SWIFT is close to CPSAM in accuracy and faster than watershed detection.

0.28

Beyond Accuracy: Uncertainty-Guided Boundary Refinement for Reliable Biomedical Image Segmentation

cs.CV cs.LG ·2026-09-11 ·Anima Kujur
similarity 0.53
Abstract

Accurate biomedical image segmentation requires not only high global overlap but also reliable delineation of clinically meaningful boundaries. In blood-smear microscopy, cytoplasm and nucleus contours provide the structural basis for downstream morphology analysis; however, deep segmentation models may remain uncertain or overconfident near ambiguous boundary regions even when achieving strong Dice scores. This work proposes a Reliability-Aware Boundary Refinement Network (RABR-Net), a two-stage framework for trustworthy image segmentation. A strong UNet++ EfficientNet-B4 base segmenter first produces initial class probabilities and logits. Predictive entropy, test-time augmentation variance, margin uncertainty, probability gradients, and soft boundary cues are then combined into a boundary-aware reliability representation. This representation guides a gated residual refiner that selectively corrects uncertain boundary pixels while preserving confident regions of the base prediction. The framework is evaluated using overlap accuracy, class-wise Dice, Boundary Dice, HD95/ASSD, calibration, risk--coverage analysis, robustness under image perturbations, qualitative correction maps, and paired statistical testing. On the held-out test set, the proposed method improves Dice from 0.9602 to 0.9614, Boundary Dice from 0.3448 to 0.3611, and HD95 from 3.0354 to 2.8274 compared with the cached base prediction. Statistical analysis confirms significant improvements in Dice, Boundary Dice, and HD95. Qualitative results show that the learned gate concentrates around uncertain cytoplasm and nucleus boundaries, and correction maps confirm localized boundary refinement. Although calibration does not automatically improve after refinement, the proposed framework provides an interpretable and reliability-focused strategy for boundary-sensitive biomedical image segmentation.

0.22

Observer Choice and Threshold Selection in Retinal Vessel Segmentation: A Subject-Separated Evaluation

cs.CV eess.IV ·2026-09-22 ·Wenhao Xu, Yixian Kong, Ting Pan, Feilong Wang, Changwei Wang
unusual similarity 0.53
Abstract · 7 pages, 3 figures

The annotation used to select a segmentation threshold is part of the evaluation protocol, yet its effect is easily conflated with model quality. We examine this choice for retinal vessel segmentation using all 28 CHASE DB1 images and both human annotations. A fixed seven-fold protocol keeps both eyes of each of the 14 subjects together. Random forests and Extra Trees are fitted against observer 1 with three random seeds, yielding 42 fits. Five threshold policies share identical score maps: fixed 0.50, observer-1 tuning, observer-2 tuning, mean-observer tuning, and maximin tuning of the per-image lower observer Dice. For random forests, maximin changes the threshold in 19 of 21 fits, but worst-observer Dice decreases from 70.53 percent to 70.45 percent. The paired difference is -0.073 percentage points, with a conditional subject-bootstrap 95 percent interval of [-0.384, 0.238]. Extra Trees shows the same direction. Identical observer-1-tuned random-forest masks score 73.66 percent against observer 1 and 71.06 percent against observer 2. The results support explicit reporting of both the threshold-selection reference and evaluation reference; they do not support an accuracy benefit from maximin tuning in this cohort. All splits, raw predictions, metrics and code are supplied. AI assistance is disclosed.

0.41

Beyond Uncertainty: Generalizable Failure Monitoring for Surgical Segmentation under Acquisition Degradation

cs.CV ·2026-08-17 ·Hieu D. Pham, Dang P. M. Cao, Thanh Trung Huynh
published similarity 0.53
Abstract · Accepted at MICCAI'2026 @UNSURE Workshop

Surgical segmentation networks can fail silently under acquisition degradation: predicted masks may be wrong even when model confidence remains high. Existing deployment-time monitors rely primarily on uncertainty estimates and can therefore miss confident failures. We present TCSR-Monitor (Temporal Conformal Surgical Risk Monitor), a post-hoc failure-monitoring framework that combines confidence with observable shape, temporal-consistency, and image-quality cues. TCSR-Monitor wraps a frozen segmentation model, requires no model internals, and operates without ground truth at deployment. We also introduce a validation protocol to assess whether alarms remain credible under distribution shift. On EndoVis 2017, leave-one-corruption-out evaluation shows that TCSR-Monitor generalizes to unseen acquisition degradations and substantially outperforms confidence-based baselines. A circularity control confirms that it predicts segmentation failure rather than simply detecting corrupted images. Mondrian conformal calibration balances miss-rates across degradation severities, but a single global threshold still produces false alarms on up to 40% of correctly segmented frames at moderate corruption. Zero-shot transfer to SAM2 demonstrates feature portability, although entropy outperforms the transferred monitor at both evaluated thresholds. Overall, reliable monitoring under acquisition degradation benefits from complementary observable signals beyond confidence alone, but substantial false-alarm and transfer limitations remain.

0.34

LightMedSeg-ISLES: Stroke Lesion Segmentation with 81x Fewer Parameters than nnU-Net

cs.CV cs.LG ·2026-09-09 ·Giorgi Nikvashvili, Hanxue Gu, Jie Bao, Kang Wang, Yang Yang
similarity 0.52
Abstract · 8 pages, 3 figures. Submitted to ISLES 2026 challenge. To be published in Springer Lecture Notes in Computer Science (LNCS) as part of the S…

Large networks and ensembles often lead medical image segmentation challenges, but their storage and inference demands complicate deployment. We present LightMedSeg-ISLES, a 1.26-million-parameter pipeline for T1-weighted stroke lesion segmentation in ISLES'26. On a 146-case held-out cohort, flip test-time augmentation produces 0.618 mean Dice and 0.599 lesion-wise F1. A 102.35-million-parameter nnU-Net ResEnc-L produces 0.634 Dice and 0.544 lesion-wise F1 after size filtering. LightMedSeg therefore retains 97.5\% of nnU-Net's Dice with 81.4$\times$ fewer parameters while improving lesion-wise F1 by 0.055. Its four-pass TTA operating point requires 4.7$\times$ fewer FLOPs per standardized patch than nnU-Net. It also slightly exceeds filtered UNETR++ and nnFormer. Longer training and stronger augmentation add 0.0358 Dice without increasing capacity, establishing a strong single-checkpoint alternative to much larger models.

0.38

TernScope: Model-Hardware Co-Design for Efficient Ternary Endoscopic Segmentation

eess.IV cs.ARcs.CV ·2026-10-21 ·Zhuoyu Wu, Wenhui Ou, Qiawei Zheng, Xuhong Qiu, Wenqi Fang +1 more
code/data similarity 0.52
Abstract · 5 pages, 4 figures, 3 tables. Code and experimental results: https://github.com/ReaganWu/TernScope

Edge medical segmentation must reconcile small model size, high accuracy, and fast inference. TernScope addresses this tradeoff through model--hardware co-design, learning a compact segmentation network whose low-bit operators also simplify hardware execution. Split-channel large-kernel blocks preserve spatial context with limited computation, while branch fusion removes redundant inference paths. Ternary Progressive Quantization-aware Training (TPQ) then adapts the fused network from deep to shallow layers, through the decoder, and finally to the input and prediction layers. All 25 convolutions use ternary weights and 8-bit activations, enabling packed storage and multiplier-free computation. The resulting model uses 0.2483 M parameters and 0.0949 GMACs while retaining competitive segmentation accuracy on in-domain and external datasets. Under the same 45 nm technology, TernScope reduces compute-array area by 88.46% compared with the original Gemmini, a systolic-array accelerator with 8-bit $\times$ 8-bit multipliers. These results demonstrate a path from accurate lightweight medical segmentation to compact low-bit hardware.

0.39

Region-aware error triage for medical image segmentation with groupwise conformal risk control

cs.CV ·2026-11-06 ·Nishi Kanta Paul, Md Shihabul Islam Shovo, Hoileong Lee
similarity 0.52
Abstract · 22 pages, 7 figures, 12 tables. Submitted to Biomedical Signal Processing and Control (BSPC)

Segmentation masks are increasingly reviewed rather than redrawn, which requires knowing where a mask is likely wrong. Learned error maps rank pixels by risk, but the number of pixels to warn is chosen ad hoc, and calibrating one warning threshold over all error pixels may leave errors far from the predicted contour under-flagged. We propose RACE-Triage, a post-hoc error triage framework that leaves the segmentation mask unchanged. A risk network is trained on out-of-fold predictions from backbone-independent inputs. The predicted contour partitions each image into a boundary band and a non-boundary region, and conformal risk control is applied separately in each region to bound the expected fraction of missed errors among cases with errors there. On ISIC 2018 dermoscopy and BUSI breast ultrasound (where patient identifiers are unavailable, so independence across images is assumed), pooled control met its overall target but missed on average 31.8% and 36.4% of non-boundary errors. Regional control reduced these fractions to 19.3% and 20.9% and raised the recall of size-filtered false-negative components from 0.722 to 0.818 and from 0.611 to 0.763. The mean warned area grew by 1.6 and 4.9 percentage points, and its 95th percentile reached 23.5% and 38.5%. The effect held across three seeds and a second backbone, and area-matched heuristics did not reproduce it. On the external PH$^2$ set, frozen thresholds exceeded both targets, whereas recalibration with 100 local images brought the mean over repeated splits below them. Regional calibration improves non-boundary error coverage at a measured increase in warned area.

0.30

Less Is More: A Leakage-Controlled Study of Dermoscopic Preprocessing for Joint Skin Lesion Classification and Segmentation with YOLO26

cs.LG cs.CV ·2026-10-06 ·Truong Viet Vu, Nguyen Chi Hai, Nguyen Phuc Nguyen, Ngo Hoang Tu, Vo Nguyen Quoc Bao +1 more
hot direction similarity 0.52
Abstract · 6 pages, 3 figures, 5 tables

Handcrafted preprocessing is widely employed in automated dermoscopic analysis to suppress imaging artifacts and enhance lesion visibility. Nevertheless, its actual contribution to modern real-time models remains unclear, particularly when evaluation protocols do not adequately control correlations among images of the same lesion. This study presents a leakage-controlled, lesion-disjoint evaluation of dermoscopic preprocessing and augmentation for joint multi-class lesion classification and instance segmentation using a fixed nano-scale YOLO26 segmentation model (YOLO26n-seg). From HAM10000 (10,015 images), quality control yields 10,013 valid image-mask pairs from 7,468 unique lesions, partitioned into mutually exclusive sets by lesion identity. With the architecture, resolution, training budget, and evaluation protocol held fixed, we compare minimally processed images plus online augmentation against offline class balancing, DullRazor-CLAHE preprocessing, and raw-processed hybrid views, over three random seeds. On the lesion-disjoint test set, the raw baseline achieves a mask mAP$_{50:95}$ of $0.5636 \pm 0.0234$, a Dice score of $0.9356 \pm 0.0024$, and a macro-F1 score of $0.6917 \pm 0.0202$. Offline augmentation does not improve the mean performance, while the combined and hybrid strategies reduce both class-aware segmentation and classification accuracy. At only 2.69 million parameters, the model runs at approximately 50 frames per second. Under a leakage-controlled, lesion-disjoint protocol with all non-input factors held fixed, minimally processed dermoscopic images combined with standard online augmentation deliver a better accuracy-efficiency trade-off than increasingly complex deterministic preprocessing, which yields no consistent joint benefit across three seeds on HAM10000.

0.36