CS Paper Radar

SelfCue: Making a 3D CT Report Generator Say What It Already Knows

Renjie Liang, Yang Yang, Jinqian Pan, Zhengkang Fan, Chengkun Sun, Jie Xu

cs.CV ·submitted 2026-09-25 01:10 UTC · v1
code/datahot direction

Abstract

Progress in 3D CT report generation is usually sought in increasingly sophisticated architectures and larger pools of training data. We find instead that a 3D CT report generator already holds what its report leaves out, and loses it when the hidden state becomes tokens. Over the 18 CT-RATE abnormalities, this hidden-to-report surfacing gap is reflected by a drop in macro AUROC from 0.848 in the hidden states to 0.739 in the generated report. We propose SelfCue based on contrastive decoding. It promotes what the hidden state already supports and suppresses what it does not. It raises clinical efficacy F1 to 0.481 and the LLM-judged GREEN score to 0.510. Distilling that behaviour into the weights gives SelfCue-KD, a student that keeps most of the gain, needs nothing extra at inference, and drops into any pipeline already serving the baseline. Code is available at https://github.com/renjie-liang/SelfCue-CT.

Closest papers

Nearest neighbours by meaning across the whole index.

PerFact: Perception-Derived Fact Prompting for 3D Brain MRI Report Generation

cs.CV ·2026-08-18 ·Jianyu Sun, Zhenxuan Zhang, Guang Yang, Peter J. Lally
similarity 0.61
Abstract

Radiology report generation has matured almost entirely on 2D chest radiographs, where the default route to better reports is a larger backbone or a pre-training one on medical data. We revisit that assumption on 3D multi-sequence brain MRI, a volumetric multi-disease regime, and find that the model is not the lever. Zero-shot medical and radiology vision-language models transfer poorly to brain MRI, with chest radiograph specialists failing most conspicuously, and five backbones fine-tuned identically across three model families and an order of magnitude in scale differ only marginally. What determines the quality of the report is the information injected into the prompt. We delegate perception to upstream 3D segmentation and classification, serialize their outputs into a structured fact sentence, and prompt a LoRA-adapted vision-language model with it; we call this \textbf{PerFact}. In a controlled study that fixes the backbone, data split, target reports, and adaptation while varying only the injected grounding, perception-derived facts outperform retrieved prior reports, retrieval becomes redundant once facts are present, and end-to-end predicted facts remain effective without any ground-truth annotation at inference. The residual gap between predicted and oracle facts is explained by the granularity of the facts rather than by the generator. Closed-ended visual question answering comes at no measurable cost to report quality, though the grounding source has little effect on it. On 3D brain MRI, grounding information, not model choice, is the dominant controllable factor in report quality.

0.27

EviGround-CT: Sentence-to-Volume Grounding for Verifying LLM-Generated Chest CT Reports

cs.CL cs.CVcs.LG ·2026-10-15 ·Ziyuan Li, Juncheng Ni, Feng Li
published similarity 0.61
Abstract · Accepted at IEEE BIBM 2026

Chest computed tomography (CT) reports generated by large language models (LLMs) can describe positive findings that lack localized evidence in the scan. We propose EviGround-CT to verify these findings after report generation. A deterministic extractor identifies positive finding sentences, and a 3D grounding model predicts an evidence mask for each sentence. Using the full sentence retains anatomical location, laterality, and descriptive modifiers in the grounding query. We evaluate report generation on CT-RATE, and grounding and verification on a held-out 100-case ReXGroundingCT subset. Using the available annotations, sentence-grounded verification raises evidence-supported precision (ESP) from 0.263 to 0.365 across 137 extracted in-scope positives, compared with category conditioning. The corresponding unsupported positive finding rate falls from 0.737 to 0.635. The paired case-level bootstrap ESP difference is +0.102 (95% confidence interval: [0.028, 0.181]). The predicted masks associate individual report statements with spatial evidence that can be inspected alongside the CT.

0.23

Reliability-Aware Benchmarking of Self-Supervised Learning in Histopathology Under 1-10% Label Regimes

cs.CV cs.LG ·2026-11-04 ·Alicem Koyun, Pranjali Changadeo Pingale, Sachin Mote, Gianluca Pizzuti
publishedbenchmarkcode/data similarity 0.61
Abstract · Oral presentation, CIBB 2026 (21st International Conference on Computational Intelligence Methods for Bioinformatics and Biostatistics, Rome…

Expert annotation in digital pathology is expensive, and low-label regimes remain common in realistic histopathology workflows. Self-supervised learning (SSL) offers a practical way to learn transferable representations from unlabeled pathology images, but performance-only evaluation can hide unreliable confidence behavior under domain shift. We present a reliability-aware benchmark of SimCLR, BYOL, and an MAE-inspired masked-reconstruction baseline on PatchCamelyon (PCam; 96x96) and PANDA (prostate cancer) under 1%, 5%, and 10% labeled regimes with frozen-encoder linear probing. To address common single-run concerns, ResNet-18 results are repeated over 3 splits x 3 seeds (n=9) and ViT-B/16 over 1 split x 3 seeds (n=3) under practical compute constraints, with mean+/-std reporting and per-run logs. Beyond AUROC, accuracy, and F1-score, we report Expected Calibration Error and Brier score, OOD confidence diagnostics for cross-dataset PCam<->PANDA scoring, federated-vs-centralized SimCLR comparisons on PCam, and cross-dataset transfer to colorectal histology tiles. SSL improves label efficiency on the more controlled PCam task, while PANDA's noisier patch-level proxy can remain near coin-flip with higher variance. The study highlights that histopathology SSL should be assessed not only by ranking performance but also by calibration, robustness, and transparent reproducibility diagnostics before clinical interpretation.

0.41

LiFUSE: Frequency-Spatial Unified Self-Supervised Pretraining for Liver Disease Analysis on Non-contrast CT

cs.CV cs.AIcs.LG ·2026-10-13 ·Hao Zhang, Yi Huang, Wei Liu, Yuan Gao, Zeju Li +4 more
published similarity 0.61
Abstract · Accepted at the 2026 IEEE International Conference on Bioinformatics and Biomedicine (BIBM 2026)

Given the growing global burden of liver tumors and diffuse liver diseases, non-contrast computed tomography (NCCT) is increasingly used for opportunistic screening because of its low cost and favorable safety profile. However, downstream tasks such as tumor detection and fine-grained disease diagnosis remain challenging due to NCCT's inherently low tissue contrast, lack of hemodynamic enhancement, and complex anatomical background. These limitations make subtle, heterogeneous, and multifocal hepatic lesions difficult to identify. Although large-scale self-supervised pretraining can learn robust representations from unlabeled NCCT scans, conventional voxel-wise reconstruction does not fully exploit the complementary information available in NCCT. Under weak NCCT contrast, low-level intensity patterns become less informative for pathology recognition, limiting the capture of lesion-specific discriminative features. In this paper, we propose the Liver Frequency-Spatial Unified Self-Supervised Pretraining (LiFUSE). The frequency branch applies random band-stop masking and spectrum reconstruction to encourage the model to capture subtle differences between lesions and surrounding tissues, while the spatial branch performs hybrid-granularity masked volumetric reconstruction to accommodate lesions of diverse sizes and morphologies. Finally, a cross-domain consistency scheme couples the spatial and frequency branches, yielding more discriminative representations for hepatic structures and lesions. Extensive experiments on three clinically relevant tasks across internal cohorts and a public target-domain transfer setting show that LiFUSE consistently outperforms strong baselines. These results suggest that unified frequency-spatial learning can improve liver disease analysis on NCCT, highlighting its potential for large-scale screening.

0.16

ProtoBridge-CLIP: Observation-Masked Finding Prototypes for Medical Image--Report Representation Learning

cs.CV cs.AI ·2026-11-18 ·Jinrui Wu, Yun Peng
similarity 0.60
Abstract

Radiology reports distinguish affirmed findings, explicit negations, and unmentioned concepts, but conventional global image--report contrastive learning often compresses these different evidence states into a single study-level target. We introduce \model{}, which combines symmetric global image--report alignment with observation-masked finding supervision and a soft relation objective over affirmed report concepts. Text-derived finding prototypes are aligned with local visual tokens, while uncertain and unmentioned concepts are excluded from direct finding labels. We evaluate the framework on three CT benchmarks and five chest-radiograph benchmarks, together with component ablations, paired and clinical retrieval, localization, perturbation robustness, calibration, and per-finding analyses. \model{} achieves macro-AUROC values of 73.6%, 66.5\%, and 68.8% on CT-RATE, RAD-ChestCT, and INSPECT, and 80.2%, 91.4%, 78.5%, 86.5%, and 90.8% on ChestXray14, CheXpert, PadChest, RSNA, and SIIM-ACR, respectively. Relative to the matched global-only controls, the findings and relation objectives yield consistent gains across the evaluated datasets. These results demonstrate the practical value of treating observed and unobserved report concepts differently during medical image--text representation learning.

0.18

The Predictability Bias of Joint-Embedding Predictive Learning in Medical Imaging

eess.IV cs.CVcs.LG ·2026-10-09 ·Fabian Drexel, Bernhard Kainz, Jakob N. Kather, Daniel Rueckert, Lisa C. Adams +2 more
similarity 0.60
Abstract · 45 pages, 6 figures

Joint-embedding predictive architectures (JEPAs) learn by predicting teacher representations of masked regions from visible context. Point prediction summarizes the conditional target distribution and cannot reproduce variation that the context does not resolve. We call this constraint predictability bias. In computed tomography (CT), recurrent anatomy is predictable from context, whereas the sporadic, localized pathology that determines clinical interpretation often is not. We introduce TAP-JEPA, a ViT-B/3D trained on 113,611 CT volumes that is competitive with state-of-the-art encoders (COLIPRI, Merlin, VoxelFM) in scan-level classification. We then audit the learned predictive pathway by replaying the exact masking, teacher, and predictor computations used during training. Prediction lowers the mean Skill (prevalence-normalized average precision) from 0.388 to 0.271 for pathology, but only from 0.921 to 0.873 for anatomy. Along the teacher direction, separating pathology from matched control regions in the same organ, prediction moves pathology 34.7% toward the controls and controls 13.6% toward pathology, with larger shifts farther from visible context. Replacing visible matched-control representations increases surrounding-target prediction loss more than fully replacing pathology representations across four pathology categories. Downstream, removing all final-layer pathology tokens reduces the decision margin by at most 0.45% in four of seven scan-level probes. Together, these results show that contextual predictability is not a sufficient proxy for clinical relevance in medical representation learning. Training objectives should therefore retain diagnostic features regardless of their predictability from surrounding anatomy.

0.19

Efficient Self-Supervised Adaptation of 3D Abdominal Vision-Language Model for Institution-Specific HCC Classification via Full Fine-Tuning and PEFT

cs.CV cs.LG ·2026-11-17 ·Febryan Putra Kartika, Cheng-Yu Ma, Ying-Jia Lin, Chi-Tung Cheng, Kuan-Fu Chen
published similarity 0.60
Abstract · 25 pages, 12 figures, 7 tables, including appendices. Corrected author revision of the MIDL 2026 paper. Revised preprocessing yields lower H…

Medical vision-language models (VLMs) capture cross-modal relationships between image and text, yet their adaptation to institution-specific clinical tasks remains underexplored. In this study, we fine-tuned a pretrained 3D medical VLM for hepatocellular carcinoma (HCC) classification using paired abdominal CT scans and radiology reports from a different institution with acquisition characteristics that differ from the model's original pretraining corpus. We compared two adaptation strategies: full fine-tuning and parameter-efficient fine-tuning (PEFT), motivated by the common use of PEFT to reduce computational cost and enable adaptation under limited-data constraints. Both approaches achieve strong downstream HCC classification performance despite the cross-institutional domain shift, with PEFT reaching an AUC of 0.79 and F1 of 0.70, and full fine-tuning achieving an AUC of 0.82 and F1 of 0.71. Although these results remain below the performance reported by supervised HCC classification approaches, our method achieves improvements over the pretrained model through CT-report contrastive learning without requiring lesion-level annotations or HCC classification labels as training targets. Full fine-tuning converges rapidly but overfits within a few epochs, whereas PEFT (ConvLoRA for the image encoder and LoRA for the text encoder) attains comparable performance while updating approximately 1% of the model parameters, although requiring more training steps. We also examine the role of contrastive temperature, observing that temperature initialization significantly affects classification performance. This study demonstrates that a 3D medical VLM can be efficiently adapted to institution-specific HCC classification using self-supervised CT-report contrastive learning, while highlighting the practical trade-offs between full fine-tuning and parameter-efficient fine-tuning.

0.38

Learning a Rule Bank to Revise 3D CT Reports with Independent Evidence

cs.CV cs.AI ·2026-11-20 ·Renjie Liang, Mengxian Lyu, Zijian Xu, Boxin Zhao, Yang Yang +5 more
code/data similarity 0.59
Abstract

Vision--language models can generate fluent radiology reports from 3D chest CT scans, yet they may still omit abnormalities or misstate findings. Independent image analysis using models separate from the report model provides additional observations, but acting on uncertain evidence may introduce new errors. We propose an agent system that learns a revision policy represented as an executable rule bank for each report model. Inspired by experience banks, the agent proposes and refines rules using revision outcomes across development cases. During inference, the retained rules guide local edits using independent classifier predictions and quantitative image measurements without retraining the report model. Unedited sentences are preserved, and each change is linked to the rule that triggered it. On CT-RATE, revision increases CE-F1 by 11.5 points for SelfCue-KD and 0.9 points for NV-Reason-CT, with gains across five draft-sampling seeds. SelfCue-KD's CT-FineBench score also increases by 15.2 points. Draft-only rule learning yields limited gains, while the two image-evidence sources provide complementary benefits for abnormality detection. Measurements also supply numerical details missing from the drafts. These results support learning model-specific rules to control how independent image evidence informs report revision. Code is available at https://github.com/renjie-liang/CT-RuleBank.

0.47