Multi-Aperture PPG with MAPIS: Spatial Optical and Temporal Coherence Fields

Shuguang Wang, Yuanjing Wang

cs.CV physics.optics ·submitted 2026-09-27 17:38 UTC · v1
unusual

Abstract

Conventional reflectance photoplethysmography (PPG) typically reduces tissue optical responses to one or a few detector channels. Matrix Pinhole Image Sensing (MAPIS) instead simultaneously samples multiple aperture-dependent optical signals. We analyzed 44 recordings of 30 seconds each from a single MAPIS device to characterize the spatial relationships among DC intensity, pulsatile AC, perfusion index (PI), and temporal coherence across Red and infrared channels. AC increased sublinearly with DC at both wavelengths, resulting in higher PI toward lower-DC apertures, consistent with a first-order relative path-sensitivity interpretation. A second counterintuitive spatial trend was observed in temporal coherence: lower-DC and lower-AC apertures exhibited higher autocorrelation and greater cardiac-periodic spectral concentration. IR signals also showed consistently higher temporal coherence than corresponding Red signals. These observations demonstrate that multi-aperture PPG resolves reproducible spatial relationships among optical intensity, fractional pulsatile sensitivity, and waveform coherence that are largely averaged together in conventional single-channel PPG. The present study establishes within-device relationships and motivates controlled studies of the underlying photon-path mechanisms.

Comment
10 pages, 3 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Property-Specific Recoverability from Contact PPG to Camera rPPG under Heterogeneous Observation Conditions

eess.SP cs.AI ·2026-08-27 ·Timothy Oladunni, Farouk Ganiyu-Adewumi
similarity 0.55
Abstract

Camera-derived remote photoplethysmography (rPPG) is commonly validated through endpoint accuracy, but endpoint performance does not establish whether other physiological properties of source contact photoplethysmography (PPG) remain preserved recording by recording. We evaluated property-specific PPG-to-rPPG recoverability on 655 recordings from the Multi-Domain Mobile Video Physiology Dataset using CHROM as a fixed camera-rPPG observation pathway. The pathway reproduced the published CHROM correlation regime, with heart-rate MAE of 15.26 bpm and Pearson correlation of 0.0801. Matched-versus-shuffled validation revealed modest recording-specific autocorrelation correspondence, while spectral and recurrence-rate measures showed little matched discrimination. Maximal Lyapunov exponents showed essentially no recording-specific PPG-to-rPPG correspondence, with correlation of 0.0231 and permutation p-value of 0.5584, despite population-level overlap. Endpoint discrepancy exhibited Fitzpatrick-associated heterogeneity after adjustment for lighting and motion, including a Fitzpatrick VI versus III contrast of 9.32 bpm, while dynamical discrepancy showed no corresponding gradient. Aggregate RGB signal-to-noise ratio did not materially account for the endpoint contrast. In subject-held-out analysis, adding motion and lighting consistently reduced MAE across linear, ridge, and random-forest learners relative to rPPG-HR-only calibration, with reductions up to 13.32 percent. These findings show that recoverability is property-specific: physiological properties differ in recording-specific preservation and dependence on observation conditions, and population-level plausibility does not establish preservation of individual recordings.

0.27

Effect of Photoplethysmogram Artifacts on Uncertainty in Atrial Fibrillation Detection

eess.SP ·2026-08-10 ·Andrius Sološenko, Enikö Vargova, Loïc Coquelin, Vaidotas Marozas, Andrius Petrėnas
similarity 0.52
Abstract

Detection of atrial fibrillation (AF) from photoplethysmogram (PPG) is highly sensitive to artifacts, yet their effect on uncertainty of different AF detectors remains poorly understood. This work aims to quantify how different PPG artifact types affect the uncertainty of AF detectors. Two machine learning approaches to AF detection were explored: one using 25-s PPG signals as input ($\mathit{D}_r$) and another using AF-related rhythm irregularity features ($\mathit{D}_f$). The detectors were trained on wrist PPG signals acquired during cardiac rehabilitation and then systematically evaluated on 260,000 PPG signals containing controlled artifact types and durations. Uncertainty was quantified using a threshold-based error rate, conformal prediction, and Monte Carlo dropout. Using artifact-free PPG signals, $\mathit{D}_f$ outperforms $\mathit{D}_r$ with sensitivity/specificity of 0.94/0.94 versus 0.92/0.86. Relative to artifact-free performance, sensitivity/specificity drops by 0.52/0.03, 0.25/0.03, 0.16/0.02, and 0.07/0.02 using $\mathit{D}_r$ for 12-s artifacts of device displacement, forearm motion, hand motion, and poor contact respectively. For $\mathit{D}_f$, the respective drops are 0.31/0.07, 0.19/0.11, 0.14/0.15, and 0.13/0.21 for the same artifacts. $\mathit{D}_f$ is more robust to short artifacts but exhibits increasing uncertainty with longer artifact durations, whereas $\mathit{D}_r$ shows an abrupt performance drop when artifacts occur but is less sensitive to artifact duration. Applying conformal prediction with 90$\%$ coverage reduces the false-positive rate by up to 12$\%$ for $\mathit{D}_r$ and up to 64$\%$ for $\mathit{D}_f$. Artifact type and duration have detector-specific effects on AF detection uncertainty. Device displacement causes the largest increase in uncertainty.

0.04

Differentiable Inverse Rendering Recovers Intrinsic Properties from Intravascular Optical Coherence Tomography

cs.CV eess.IVphysics.med-phphysics.optics ·2026-11-09 ·Ajay Manicka, Karim Kadry, Sebastian Ruiz-Lopera, Maryam Alsharqi, Sanjana Arji +5 more
similarity 0.51
Abstract · 27 Pages, 6 Figures, Under Review

Medical images encode intrinsic tissue properties that indicate disease progression, yet these properties remain entangled with the system-dependent physics of image formation. Differentiable inverse rendering asks whether they are recoverable by inverting the imaging system's forward physics rather than through post-hoc correction. We address this in optical coherence tomography (OCT), focusing on the optical attenuation coefficient, a per-pixel marker of pathology and cellular composition. Conventional recovery relies on closed-form inversions limited to simplified light-tissue models, or learned methods coupled to specific imaging configurations. We instead recover per-pixel attenuation from a single OCT image by gradient descent through a differentiable physics-based forward model. We verified the method against analytical solutions, validated it on five in vitro phantoms, and applied it without modification to 29{,}269 clinical intravascular OCT images from 128 patients. The inversion needs no training data or segmentations and is portable across platforms and retrospective archives. Replacing the forward model or recovering another optical parameter leaves the optimization procedure unchanged. We demonstrate per-pixel recovery is tractable because gradient information scales to this high-dimensional problem, where gradient-free methods become intractable. Our work supports quantitative tissue characterization from OCT images and provides a framework for extension across imaging modalities and organ systems.

0.26

Perturbation-Based Reconstruction of Depth-Resolved OCT Attenuation without Requiring a Fully Decayed Signal Tail

eess.IV physics.optics ·2026-11-04 ·Jinglun Yu, Yaning Wang, Shuwen Wei, Jin U. Kang
unusual similarity 0.50
Abstract · 26 pages, 10 figures, including 1 supplementary figure. Submitted to Biomedical Optics Express

Depth-resolved attenuation in optical coherence tomography (OCT) can provide quantitative optical contrast beyond structural imaging. However, conventional reconstruction methods can be biased when the OCT signal does not fully decay within the imaging range or when the distal signal tail is dominated by noise or residual reflections from distal sample or support interfaces. Here, we present a perturbation-based Beer-Lambert framework that combines a zeroth-order exponential estimate with a first-order correction, reducing reliance on the unreliable distal signal tail below the current depth. Numerical A-line simulations, Monte Carlo modeling, multilayer silicone-dye-TiO2 phantoms, and ex vivo bovine retina experiments were used to evaluate the method under finite-depth and heterogeneous imaging conditions. The numerical A-line tests showed reduced depth-dependent error against prescribed attenuation profiles; the Monte Carlo comparisons showed less distal drift relative to model-defined benchmarks, while the phantom profiles were compared with separately acquired single-layer OCT calibration values. In a Monte Carlo component test that withheld vessel-mask and vessel-boundary information from reconstruction and used that information only for post hoc evaluation, the first-order correction recovered 61% of the segmentation-informed target vessel contrast and reduced vessel ROI mean absolute error by 65% relative to the fixed zeroth-order baseline. These results suggest that perturbation-based reconstruction may provide a practical approach for depth-resolved reconstruction of effective OCT attenuation when the fully decayed A-line condition is not satisfied.

0.30

Impact of Multiple Non-Invasive Biosignals on Cardiovascular Biomarker Estimation via Simulation-Based Inference

cs.LG physics.med-phstat.AP ·2026-08-26 ·Shusaku Maeda, Masahiro Nakano, Tomoharu Iwata, Kenji Komiya, Ryo Nishikimi +1 more
similarity 0.49
Abstract · 8 pages, 5 figures, 2 tables

As the population ages, the number of patients with cardiovascular diseases continues to increase, highlighting the need for early detection before progression to severe and irreversible functional decline. Consequently, estimating cardiovascular biomarkers from non-invasive biosignals, such as photoplethysmography (PPG) and arterial pressure wave (APW) signals, has attracted increasing attention. These signals can be measured using wearable and cuff-type devices. Previous studies have used PPG and APW signals to estimate cardiovascular biomarkers. However, these signals exhibit strong similarities in both the temporal and frequency domains and primarily reflect peripheral and arterial pulse waveforms. Therefore, they may provide limited information about cardiac mechanical function. In contrast, the quantitative impact of additional biosignals, such as ballistocardiography (BCG), which reflect the body's minute mechanical responses to cardiac ejection, remains unclear. In this study, we generated synthetic PPG, APW, and BCG signals from a unified whole-body cardiovascular circulation model and evaluated the complementary contribution of BCG to probabilistic cardiovascular biomarker estimation. We estimated posterior distributions of cardiovascular biomarkers using neural posterior estimation and simulation-based inference. The results showed that adding BCG signals significantly improved estimation performance. Furthermore, even in ill-posed cases where PPG and APW alone produced multimodal posterior distributions, adding BCG yielded unimodal posterior distributions. These findings provide fundamental insights into signal selection for estimating cardiovascular dynamics.

0.28

CardiacMamba: Fair and Robust RGB-RF Fusion for Remote Heart Rate Estimation via State Space Modeling

cs.CV cs.AI ·2026-08-16 ·Bo Zhao, Zheng Wu, Yiping Xie, Zitong YU
similarity 0.49
Abstract

Remote photoplethysmography (rPPG) enables non-contact heart rate (HR) monitoring from facial videos, but RGB-only methods are vulnerable to illumination changes, motion artifacts, and skin-tone-dependent optical reflectance. We propose CardiacMamba, a fair and robust RGB-RF fusion framework that integrates optical facial cues and radio-frequency cardiac motion cues through state space modeling. CardiacMamba introduces a Temporal Difference Mamba Module (TDMM) to enhance subtle RF temporal variations, a bidirectional SSM-based interaction mechanism to align heterogeneous RGB-RF dynamics, and a Channel-wise Fast Fourier Transform (CFFT) module for channel-domain spectral refinement. On the EquiPleth dataset, CardiacMamba achieves state-of-the-art performance with 0.96 bpm MAE, 3.06 bpm RMSE, and 0.97 Pearson correlation, while reducing the observed light-dark skin-tone MAE gap to 0.26 bpm and maintaining robustness under RGB degradation and RF-missing conditions

0.04

Integrating Deep PPG Representations and Digital Biomarkers for Aortic Stenosis Detection with Peri-TAVI Assessment

eess.SP ·2026-11-09 ·Haowan Wang, Cheng Ding, Donglin Xie, Huizi Yu, Guangkun Nie +3 more
similarity 0.48
Abstract

Access to echocardiography is often limited, delaying recognition of progressive aortic stenosis (AS). A brief, low-cost physiological measurement obtained during routine care could help identify patients who may warrant earlier imaging. Here, we present PulseAS, integrating deep photoplethysmography (PPG) representations, waveform biomarkers and clinical information for high-grade AS screening. Three complementary analyses assessed (1) validation and transfer across cohorts differing in geography and ethnic composition, (2) score-based enrichment of AS and pre-transcatheter aortic valve implantation (TAVI) cases, and (3) preoperative and postoperative pulse changes. Using 15-s recordings, separate patient-level cross-validation in EDU (n = 1,209) and MIMIC-III (n = 2,970) yielded AUROCs of 0.818 (PulseAS-XGB) and 0.838 (PulseAS-L2), respectively. In external validation from MIMIC-III to EDU, PulseAS-XGB achieved an AUROC of 0.716, improving to 0.813 after local adaptation. The highest-scoring 10% captured 45.2% of all high-grade AS cases in EDU and 41.3% in MIMIC-III, and 56.9% of pre-TAVI cases in EDU. Notably, in the EDU TAVI subgroup, PPG waveforms showed earlier systolic peaks and narrower systolic contours following intervention. These findings support clinical-PPG risk stratification in new populations and warrant prospective evaluation of echocardiographic prioritisation.

0.30

Pixel-wise Exposure for Highly Robust In-Vehicle Remote-PPG

cs.CV ·2026-09-29 ·Jieying Wang, Xinqi Cai, Caifeng Shan, Wenjin Wang
similarity 0.48
Abstract

Remote photoplethysmography (rPPG) offers a promising non-contact solution for heart rate monitoring, yet its real-world robustness is fundamentally limited by an inherent hardware limitation: existing camera exposure control paradigms, whether fixed or auto-exposure, impose a uniform exposure time across all pixels within a frame. In high-dynamic-range scenes such as automotive cabins with strong directional sunlight, this spatially invariant exposure constraint inevitably leads to localized facial overexposure or underexposure, irreversibly corrupting the subtle pulsatile signals essential for rPPG at the point of capture, a physical degradation that no downstream algorithm can recover. To overcome this bottleneck, we propose PixExpo (Pixel-wise Exposure), a "temporal-for-spatial" framework that sequentially captures frames under a predefined cyclic exposure schedule and performs non-iterative pixel-wise fusion. At each pixel location, PixExpo selects the observation closest to an rPPG-motivated target intensity. This criterion seeks to reduce local saturation and severe underexposure rather than optimize perceptual appearance. PixExpo requires no sensor modification but assumes programmable frame-level exposure control. We validate the proposed PixExpo framework using our newly introduced MEX-Drive dataset, comprising 48 participants under real-world driving conditions. Experimental results demonstrate that PixExpo outperforms manufacture-default auto-exposure methods, reducing the mean absolute error (MAE) by 7.21 bpm (from 13.94 to 6.73 bpm) and increasing the success rate by 37.29 percentage points (from 25.95% to 63.24%) across challenging driving scenarios.

0.21