CS Paper Radar

Isostable-Based Nonlinear Model Reduction for Power System Oscillations

Kaiyang Huang, Dan Wilson, Kai Sun

eess.SY math.DS ·submitted 2026-09-27 15:25 UTC · v1

Abstract

Power systems are often represented by high-dimensional dynamic models, making nonlinear control design computationally expensive and limiting its practical application. Oscillation analysis and damping control therefore commonly rely on linearized models, which do not capture the nonlinear oscillatory behavior induced by large disturbances. This paper proposes an isostable-based model reduction method for nonlinear modal analysis of power systems. The method constructs an invariant manifold associated with a selected oscillatory mode and uses isostable coordinates to describe the mode with only two real state variables. The isostable formulation gives linear autonomous modal dynamics, with nonlinear state reconstruction and input response computed on the modal manifold. An optimal damping control problem is then formulated directly in the reduced coordinates. Case studies on the IEEE 39-bus system demonstrate the accuracy of the proposed model in describing nonlinear oscillations and show improved damping compared with control designed using a linear reduced model.

Closest papers

Nearest neighbours by meaning across the whole index.

Reduced-Order Model Characterization of Nonlinear Sustained Oscillations

eess.SY math.DS ·2026-09-27 ·Kaiyang Huang, Dan Wilson, Kai Sun
similarity 0.72
Abstract

Nonlinear sustained oscillations involving inverter-based resources can happen when device and network interactions produce an attracting limit cycle around an unstable equilibrium. A damping controller must then describe nonlinear dynamics over the region between the two invariant sets, where a local equilibrium linearization can be insufficient. In this paper, a controlled phase--isostable model is first developed on a two-dimensional invariant manifold connecting the equilibrium and the limit cycle. Dynamics on this surface are represented by phase and isostable coordinates, while physical states and control inputs are related to these coordinates through nonlinear reconstruction and response functions. The required functions are computed from connecting trajectories and periodic-orbit data. A control strategy is then designed to provide extra damping while limiting phase distortion. Case studies on a two-area system and an IEEE 39-bus system demonstrate more effective oscillation damping than the compared equilibrium-linearized designs under the same conditions.

0.27

Nonlinear Participation Factor-based Power System Model Reduction Addressing Near-Resonance Conditions

eess.SY math.DS ·2026-09-27 ·Mahsa Sajjadi, Kai Sun
similarity 0.61
Abstract

This paper proposes an adaptive model reduction approach based on nonlinear participation factors (NPFs) which determines the most effective selection of unimportant generators in a power system to be linearized to accelerate time-domain simulation for the entire system. The method enables a dynamic transition between the full-order model, and a hybrid reduced model. It uses modal energies to rank system modes under contingencies, and computes NPFs for highly energized modes based on Normal Form theory. To accelerate the computation of NPFs and make it achievable online, a tensor contraction technique is introduced. The proposed approach is tested on a 48-machine, 140-bus NPCC system using both partitioned and unpartitioned strategies. It demonstrates significant simulation speedup while preserving better accuracy than a linear participation factor-based method if the nonlinear behaviors of the system cannot be ignored, especially when a near-resonance condition is presented.

0.28

An Analytical Review of Model Order Reduction Methodologies of Converter-Dominated Power Systems for Stability Studies

eess.SY ·2026-10-02 ·Goran Grdenić, Marco Fraccaro, Josipa-Pina Milišić
similarity 0.55
Abstract · 53 pages, 4 figures

The rapid integration of renewable energy sources is transforming modern electric power systems into converter-dominated networks characterized by complex multi-timescale dynamics and new stability interactions over a wide frequency range. Accurate analysis of these phenomena requires high-fidelity models of transmission networks and power electronic converters, which often result in large-scale differential-algebraic systems with significant computational burden. This paper provides an analytical review of model order reduction techniques for converter-rich power systems, with particular emphasis on the key equations employed in the reduction process. Advantages and limitations of commonly used strategies, including timescale-based singular perturbation, projection-based, operator-based, data-driven, and machine-learning based methods, are discussed. The synthesis highlights key challenges related to harmonic interactions and multi-frequency dynamics, and outlines directions for the development of computationally efficient yet dynamically accurate reduced-order models for future power systems.

0.29

Harmonic Stability of Power Systems: A Control-Theoretic Definition and Assessment Criteria

eess.SY ·2026-08-20 ·N. Bhoir, A. Sarkar, J. E. Machado, J. Schiffer
similarity 0.52
Abstract

Harmonic interactions have become a defining dynamic stability phenomenon in converter-based power systems (CBPSs). However, a formalization of the notion of harmonic stability in the context of nonlinear dynamical systems is not available thus far. In this paper, we propose a definition of harmonic stability formulated as a combination of two standard stability notions, namely, bounded-input bounded-output (BIBO) and internal stability properties with respect to any nominal periodic trajectory. Moreover, we rigorously show that the local harmonic stability of any nominal periodic trajectory of nonlinear CBPSs is implied by the stability properties of its linear time-periodic (LTP) approximation. In addition, to enable computationally tractable stability assessment, we develop a framework based on harmonic state-space (HSS) representations of LTP models. In particular, we provide time-invariant linear matrix inequality (LMI) conditions to certify harmonic stability. The proposed methodology is illustrated on a grid-following converter system, where the HSS-based analysis numerically confirms harmonic stability around the periodic operating trajectory.

0.29

Learn Locally, Extend Globally: Koopman Eigenfunctions and the Basin of Attraction

eess.SY nlin.CD ·2026-11-13 ·Marcos Netto, Bukunmi Gabriel Odunlami, Aditya Kale, Andrey Bernstein
similarity 0.50
Abstract

Koopman eigenfunctions associated with the Jacobian eigenvalues of a stable equilibrium are Lyapunov functions defined exactly on its basin of attraction. We turn this into a computational procedure for power systems. Eigenfunctions estimated by extended dynamic mode decomposition (EDMD) are written as functions of the state, made to vanish at the equilibrium by centering the lifted variable $\cosδ$, and verified on a grid with the model: two Lyapunov candidates from the EDMD spectrum certify up to 66\% of the basin of a single-machine infinite-bus system from data in the linear region. The Koopman semigroup property then extends the EDMD-Lie eigenfunction to the whole basin, recovered at the grid resolution with its isostables and isochrons.

0.24

Modular Model Order Reduction for Inverter-Based Power Systems with Stability and Accuracy Guarantees

eess.SY ·2026-10-01 ·Hanqing Zhang, Pudong Ge, Mohammad Fahim Shakib, Adrià Junyent-Ferré, Balarko Chaudhuri +3 more
similarity 0.49
Abstract · 10 pages, submitted to IEEE Transactions on Power Systems

This paper proposes a modular model order reduction framework for large-scale power grids integrated with renewable energy sources. The proposed framework has the advantage of reducing individual sub-areas independently while retaining the power grid interconnection structure. Moreover, given a user-defined accuracy specification on the overall reduced-order interconnected power grid, corresponding target specifications for the individual reduced sub-areas are determined: satisfaction of such individual specifications guarantees the overall user-defined accuracy specification, while also preserving the stability of the overall reduced-order interconnected power grid. The proposed framework is validated on a modified IEEE 118-bus system (where synchronous generators have been replaced by inverter-based resources) by assessing the accuracy specification satisfaction of the overall reduced-order interconnected power grid, in terms of frequency response, stability, active power, and sub-synchronous behaviour when injected with disturbances.

0.33

An Integrated EMT Small-Signal Stability Analysis Tool for Power Systems with High Inverter-Based Resource Penetration

eess.SY ·2026-09-14 ·Zihao Qin, Xiaonan Lu, Shuan Dong, Jin Tan
published similarity 0.49
Abstract · 6 pages, 4 figures, 2 tables. Accepted for presentation at the 2026 IEEE Industry Applications Society (IAS) Annual Meeting

The ongoing replacement of synchronous generation by inverter-based resources (IBRs) introduces fast converter control dynamics whose characteristic frequencies extend beyond the classical electromechanical band. Conventional small-signal stability tools are commonly formulated in the phasor domain, representing electrical quantities as slowly varying phasors at the fundamental frequency, and therefore cannot resolve the sub-synchronous and converter-driven dynamics that increasingly arise in operation. Electromagnetic Transient (EMT) modeling captures these dynamics, but established EMT simulators produce time-domain waveforms rather than the modal indicators (eigenvalues, damping ratios, and participation factors) needed to assess stability risk. This paper presents EMT-SSA, an integrated tool suite for EMT-level small-signal analysis of IBR-rich power systems. From a standard PSS/E system snapshot (.raw/.dyr), it converts the model into an EMT representation with enhanced fidelity, solves an extended power flow for the steady-state equilibrium points of both the network and the device controllers, and linearizes a full-order EMT model to form the system state matrix, from which it produces eigenvalues, oscillation modes, and participation factor analysis results over a device library spanning synchronous generators, grid-following and grid-forming inverters, transmission lines, and loads. The EMT-SSA tool suite identifies poorly damped or unstable modes and attributes them to specific devices. The tool is demonstrated on the Kundur two-area system, with its modal results benchmarked against PSS/E NEVA.

0.16

Adaptive Grid-Mode-Aware Hybrid Energy Storage Control for AI Data Center Oscillation Mitigation

eess.SY ·2026-11-04 ·Quang Manh Hoang, Sina Mohammadi, Phi Long Nguyen, Wencong Su, Van-Hai Bui
similarity 0.48
Abstract · Manuscript is submitted to PESGM2027

Oscillatory power components in AI data-center demand can produce large frequency deviations when they coincide with vulnerable grid modes. Mode-aware hybrid energy storage systems (HESSs) can selectively suppress these components, but their effectiveness degrades when the grid mode changes while the control target remains fixed. This paper proposes a closed-loop grid-mode-adaptive HESS control framework that integrates measurement-based modal identification with mode-selective control. A sliding-window N4SID estimator identifies the local grid dynamics from grid-side power and frequency measurements, and the resulting natural-frequency estimate is used to retune the modal suppression branch assigned to the supercapacitor. The framework is evaluated under a grid-mode shift from 0.50 to 1.35Hz while maintaining equal physical damping and approximately equal load excitation at both frequencies. Compared with the fixed-target controller, the adaptive method reduces the post-change grid-side modal power component from 8.78 to 2.02MW, corresponding to a 76.94% reduction, and substantially lowers the resulting frequency deviation.

0.21