CS Paper Radar

Nonlinear Participation Factor-based Power System Model Reduction Addressing Near-Resonance Conditions

Mahsa Sajjadi, Kai Sun

eess.SY math.DS ·submitted 2026-09-27 15:18 UTC · v1

Abstract

This paper proposes an adaptive model reduction approach based on nonlinear participation factors (NPFs) which determines the most effective selection of unimportant generators in a power system to be linearized to accelerate time-domain simulation for the entire system. The method enables a dynamic transition between the full-order model, and a hybrid reduced model. It uses modal energies to rank system modes under contingencies, and computes NPFs for highly energized modes based on Normal Form theory. To accelerate the computation of NPFs and make it achievable online, a tensor contraction technique is introduced. The proposed approach is tested on a 48-machine, 140-bus NPCC system using both partitioned and unpartitioned strategies. It demonstrates significant simulation speedup while preserving better accuracy than a linear participation factor-based method if the nonlinear behaviors of the system cannot be ignored, especially when a near-resonance condition is presented.

Closest papers

Nearest neighbours by meaning across the whole index.

Isostable-Based Nonlinear Model Reduction for Power System Oscillations

eess.SY math.DS ·2026-09-27 ·Kaiyang Huang, Dan Wilson, Kai Sun
similarity 0.61
Abstract

Power systems are often represented by high-dimensional dynamic models, making nonlinear control design computationally expensive and limiting its practical application. Oscillation analysis and damping control therefore commonly rely on linearized models, which do not capture the nonlinear oscillatory behavior induced by large disturbances. This paper proposes an isostable-based model reduction method for nonlinear modal analysis of power systems. The method constructs an invariant manifold associated with a selected oscillatory mode and uses isostable coordinates to describe the mode with only two real state variables. The isostable formulation gives linear autonomous modal dynamics, with nonlinear state reconstruction and input response computed on the modal manifold. An optimal damping control problem is then formulated directly in the reduced coordinates. Case studies on the IEEE 39-bus system demonstrate the accuracy of the proposed model in describing nonlinear oscillations and show improved damping compared with control designed using a linear reduced model.

0.38

An Analytical Review of Model Order Reduction Methodologies of Converter-Dominated Power Systems for Stability Studies

eess.SY ·2026-10-02 ·Goran Grdenić, Marco Fraccaro, Josipa-Pina Milišić
similarity 0.58
Abstract · 53 pages, 4 figures

The rapid integration of renewable energy sources is transforming modern electric power systems into converter-dominated networks characterized by complex multi-timescale dynamics and new stability interactions over a wide frequency range. Accurate analysis of these phenomena requires high-fidelity models of transmission networks and power electronic converters, which often result in large-scale differential-algebraic systems with significant computational burden. This paper provides an analytical review of model order reduction techniques for converter-rich power systems, with particular emphasis on the key equations employed in the reduction process. Advantages and limitations of commonly used strategies, including timescale-based singular perturbation, projection-based, operator-based, data-driven, and machine-learning based methods, are discussed. The synthesis highlights key challenges related to harmonic interactions and multi-frequency dynamics, and outlines directions for the development of computationally efficient yet dynamically accurate reduced-order models for future power systems.

0.29

Mode-in-Variance Participation Factors under Stochastic Excitation

eess.SY ·2026-11-12 ·Bruno Pinheiro, Liya Huang, Georgios Tzounas
similarity 0.55
Abstract

This paper investigates how the dynamic modes of a power system contribute to the stationary variance of its variables under continuous stochastic excitation. Using a modal decomposition of the covariance matrix, the variance of each state or algebraic variable can be resolved into components associated with individual modal responses and their interactions. These components are shown to correspond to within-mode variance and cross-modal covariance, respectively, and the corresponding normalized contributions are termed mode-in-variance participation factors (PFs). The proposed PFs can be used to identify modes governing the variability of important system quantities such as frequency and voltage, quantify the effect of modal interactions, and reveal control dynamics that can be targeted to reduce their stochastic variability. These capabilities are demonstrated through case studies based on the Kundur two-area and IEEE 39-bus systems.

0.24

Sparse Generalized-Admittance AC Power Flow for Fast Contingency Analysis and Remedial-Action Assessment

eess.SY ·2026-09-12 ·Pierre Artoisenet, Noémie Verstraete
similarity 0.54
Abstract · 8 pages, 1 figure

Repeated AC power-flow calculations are common tasks in transmission system operations, in particular for contingency analysis and remedial-action assessment. For large networks, their cumulative runtime can become a computational bottleneck in operational processes. This paper develops a sparse reformulation of the generalized bus-admittance power-flow method known as PFPD. Loads and generators are represented by fixed shunt admittance terms on the diagonal of the admittance matrix, while corrective nodal currents are iteratively computed to match the constant-power and regulated-voltage constraints. In contrast to the original formulation, the slack bus is treated as a fixed-voltage boundary and removed from the admittance block decomposition. The resulting iteration reuses sparse LU factorizations of the initial generalized non-slack matrix and its PQ block, without explicitly forming dense inverse matrices. The same formulation admits two initialization modes: an unsolved base case using the same flat-start shunt heuristic as in the primary PFPD method, and repeated post-action calculations initialized from a solved operating point. Localized topology and parameter changes are expressed as low-rank admittance updates and the resulting admittance matrices are inverted by means of the Woodbury identity. An optional local-network formulation can provide an warm start before full-network refinement. N-1 experiments on the 1354-bus and 9241-bus PEGASE systems and the 6717-bus synthetic Texas system yield average per-contingency speedups between 14.4 and 18.0 relative to pandapower. On transformer tap-position actions, the method is 2.8--2.9 times faster than pandapower and 7.2--29.9 times faster than PowSyBl OpenLoadFlow.

0.34

Modular Model Order Reduction for Inverter-Based Power Systems with Stability and Accuracy Guarantees

eess.SY ·2026-10-01 ·Hanqing Zhang, Pudong Ge, Mohammad Fahim Shakib, Adrià Junyent-Ferré, Balarko Chaudhuri +3 more
similarity 0.53
Abstract · 10 pages, submitted to IEEE Transactions on Power Systems

This paper proposes a modular model order reduction framework for large-scale power grids integrated with renewable energy sources. The proposed framework has the advantage of reducing individual sub-areas independently while retaining the power grid interconnection structure. Moreover, given a user-defined accuracy specification on the overall reduced-order interconnected power grid, corresponding target specifications for the individual reduced sub-areas are determined: satisfaction of such individual specifications guarantees the overall user-defined accuracy specification, while also preserving the stability of the overall reduced-order interconnected power grid. The proposed framework is validated on a modified IEEE 118-bus system (where synchronous generators have been replaced by inverter-based resources) by assessing the accuracy specification satisfaction of the overall reduced-order interconnected power grid, in terms of frequency response, stability, active power, and sub-synchronous behaviour when injected with disturbances.

0.33

Hybrid STAR-RIS Architecture for Joint Localization, Communication, and Power Transfer

eess.SP ·2026-08-12 ·Haoran Ni, Mohammadali Mohammadi, Xidong Mu, Hien Quoc Ngo, Michail Matthaiou
top venue similarity 0.51
Abstract · Accepted for publication in IEEE Transactions on Wireless Communications, Aug. 2026

We propose a hybrid simultaneously transmitting and reflecting reconfigurable intelligent surface (STAR-RIS) architecture with dynamically switched active and passive elements to support joint localization, communication, and wireless power transfer (WPT). We first pursue a parallel factor analysis with the alternating least squares (PARAFAC-ALS)-based tensor decomposition approach that decouples the base station (BS)-reconfigurable intelligent surface (RIS) and RIS-user channels, thereby enabling low-overhead channel acquisition. Based on this, we formulate a system energy efficiency (EE) maximization problem, subject to the spectral efficiency (SE) requirements of communication users, sensing signal-to-interference-plus-noise ratio constraints, and the nonlinear energy harvesting requirements of energy-harvesting users. The optimization problem is nonconvex since the transmit power allocation, STAR-RIS coefficients, and active/passive mode assignments are tightly coupled in both the objective and constraints. We address this issue by alternating between two subproblems, and solving them via fractional programming, successive convex approximation and a multi-seed greedy strategy employed as an initialization step. Numerical results demonstrate that selectively activating a small, well-chosen subset of STAR-RIS elements achieves 1.5 to 3 times EE improvements compared with fully passive/active architectures, while satisfying communication, sensing, and power-transfer requirements.

0.63

Symbolic Direct Construction of Augmented Systems for Levenberg-Marquardt Power Flow

eess.SY cs.PFmath.NA ·2026-10-25 ·Tianshi Cheng, Venkata Dinavahi
theory similarity 0.51
Abstract · 8pages, 1 figure

Levenberg-Marquardt power flow (LMPF) addresses ill-conditioned equations and provides least-squares stationary points for infeasible operating requests. Conventional implementations form damped normal equations, where J^T J introduces fill, squares the spectral condition number of the undamped part, and adds sparse-product cost. We propose an augmented LMPF formulation with a symbolic-permutation-based Jacobian operator that fills the augmented blocks directly. We prove that the matrix is symmetric quasi-definite for positive damping, enabling fixed-order, pivot-free QDLDL factorization. This property also motivates the solver choice: KLU value-only refactorization can reuse an unsuitable pivot order, forcing fresh full factorizations on difficult LMPF trajectories. We further introduce one-probe adaptive trust-region initialization for the radius and damping. Direct assembly is 7.5-11.9x faster than the fastest coordinate-list path and 18.0-58.8x faster than cached normal-equation sparse-product formation; QDLDL reduces numerical refactorization and triangular-solve time by up to 3.40x on identical matrices. Adaptive initialization solves flat-started RTE cases in 19-25 factorizations, 7.5-11.6x faster than reproduced three-step LM. On case2383wp, our 84-iteration run performs 84 factorizations and 168 resolves in 237 ms, versus published times of 200.780-441.72 s with fewer outer iterations, corresponding to speedups of 847-1860x. These results require complete factorization and resolve accounting and reveal initialization and legacy-parameter effects. DC-initialized NR exhibits fast quadratic convergence throughout every tested solvable loading range, motivating clearer, reproducible definitions of ill-conditioned power-flow benchmarks.

0.22

Impact of Reduced-Order Modelling on Sum-of-Squares Region-of-Attraction Certification for Grid-Forming and Grid-Following Converters

eess.SY math.OC ·2026-11-10 ·Chenxi Yuan, Jeremy D. Watson, Neville R. Watson
similarity 0.49
Abstract · 13 pages, 5 figures, 3 tables

With the increasing penetration of power-electronic equipment, the transient stability of grid-forming (GFM) and grid-following (GFL) converters is increasingly characterized through the region of attraction (ROA) of the post-fault equilibrium. Sum-of-squares (SOS) programming yields certified inner approximations of the ROA, yet its computational cost grows rapidly with system order. Reduced-order models are therefore widely used to reduce computational cost and, more importantly, to enable analytical investigation. However, ROA analyses based on these models often assume that reproducing the converter's transient response, or retaining more dynamics in the correct time-frame, is sufficient to preserve the ROA of the full-order system. Using time-domain ODE simulations as a reference, the SOS-based ROA of each reduced-order GFM and GFL model is assessed against both its own simulated ROA and that of the corresponding full-order model, thereby separating SOS-induced conservativeness from model-order-induced ROA distortion. The results indicate that increasing reduced-order model complexity does not necessarily improve SOS-based ROA fidelity. In the cases examined, more complex reduced-order models yield lower SOS coverage of the full-order reference ROA, despite closer ODE-boundary agreement in some regions. Model selection should therefore consider both full-order ROA fidelity and certified coverage of the practical operating range, rather than model complexity alone.

0.27