CS Paper Radar

Mode-in-Variance Participation Factors under Stochastic Excitation

Bruno Pinheiro, Liya Huang, Georgios Tzounas

eess.SY ·submitted 2026-11-12 14:49 UTC · v1

Abstract

This paper investigates how the dynamic modes of a power system contribute to the stationary variance of its variables under continuous stochastic excitation. Using a modal decomposition of the covariance matrix, the variance of each state or algebraic variable can be resolved into components associated with individual modal responses and their interactions. These components are shown to correspond to within-mode variance and cross-modal covariance, respectively, and the corresponding normalized contributions are termed mode-in-variance participation factors (PFs). The proposed PFs can be used to identify modes governing the variability of important system quantities such as frequency and voltage, quantify the effect of modal interactions, and reveal control dynamics that can be targeted to reduce their stochastic variability. These capabilities are demonstrated through case studies based on the Kundur two-area and IEEE 39-bus systems.

Closest papers

Nearest neighbours by meaning across the whole index.

Nonlinear Participation Factor-based Power System Model Reduction Addressing Near-Resonance Conditions

eess.SY math.DS ·2026-09-27 ·Mahsa Sajjadi, Kai Sun
similarity 0.55
Abstract

This paper proposes an adaptive model reduction approach based on nonlinear participation factors (NPFs) which determines the most effective selection of unimportant generators in a power system to be linearized to accelerate time-domain simulation for the entire system. The method enables a dynamic transition between the full-order model, and a hybrid reduced model. It uses modal energies to rank system modes under contingencies, and computes NPFs for highly energized modes based on Normal Form theory. To accelerate the computation of NPFs and make it achievable online, a tensor contraction technique is introduced. The proposed approach is tested on a 48-machine, 140-bus NPCC system using both partitioned and unpartitioned strategies. It demonstrates significant simulation speedup while preserving better accuracy than a linear participation factor-based method if the nonlinear behaviors of the system cannot be ignored, especially when a near-resonance condition is presented.

0.28

Quantifying Power to Voltage and Frequency Dynamics for Oscillation Propagation Assessment

eess.SY ·2026-09-03 ·Onur Alican, Dionysios Moutevelis, Marc Cheah-Mañe, Oriol Gomis-Bellmunt, Eduardo Prieto-Araujo
benchmark similarity 0.53
Abstract

The integration of Inverter-Based Resources (IBRs) into power systems introduces multi-timescale dynamics and oscillations which may propagate to distant areas and endanger the safe system operation. These oscillations pose a significant challenge as their source, frequency, and propagation pathways are often challenging to identify in large interconnected systems, comprising numerous synchronous machines and IBRs. For the above reasons, analytical tools that identify the sensitivity of the system to oscillations within a large frequency spectrum, affecting both voltage and frequency variables across various network locations, are of interest. This paper addresses this topic by introducing a frequency-domain framework based on linear analysis, which characterizes the sensitivity to oscillations of each network bus voltage and of each generation unit frequency. Within this framework, two quantitative indicators are proposed, namely the Frequency Sensitivity Index (FSI) and Voltage Sensitivity Index (VSI). These indexes are derived analytically from the transfer functions which relate the active and reactive power injections to each bus with the voltage and frequency variables across the network, derived from the linear Electromagnetic Transient (EMT) power system model. The proposed indices quantify the sensitivity of the system to oscillations of different type and frequency, providing insights for both oscillation detection and propagation analysis. The methodology is applied to a case study based on the modified IEEE 68-bus benchmark system under partial and full IBR penetration, while its accuracy is validated through EMT time-domain simulations using linear and nonlinear models developed in Matlab/Simulink environment.

0.28

DC-TORQ: Fast Assessment of Data Center-Induced Generator Torsional Oscillation Risk Quantification

eess.SY ·2026-10-15 ·Yingyi Tang, Bin Wang, Junbo Zhao, Qiang Zhang, Pradip Vijayan +2 more
benchmark similarity 0.52
Abstract

The periodic power demand of large data centers can introduce forced oscillations into the power system. When these oscillations contain frequency components near a turbine-generator torsional mode, they may excite sustained shaft torque oscillations with amplitudes exceeding the allowable cyclic torque limits. Characterizing the impact of data center power oscillations on generator shaft torque requires accounting for frequency-dependent network coupling among the data center, the transmission network, and the generators. Although electromagnetic transient (EMT) simulations can capture these interactions in detail, repeated simulations across excitation frequencies and load locations can be computationally demanding. This paper proposes an analytical framework for data center induced torsional oscillations that retains the coupled electrical and shaft dynamics. A detailed generator-network model is established, and closed-form transfer functions that map data center power perturbations to the torque in each shaft section are derived. Admissible shaft torque amplitudes are then translated into frequency-dependent limits on data center power oscillations. The proposed framework enables fast assessment of the shaft torque response while accounting for network dynamics and provides a quantitative screening criterion for candidate data center connection buses. The framework is validated on the IEEE benchmark model and applied to the IEEE 39-bus system.

0.19

Cascading Contingency Analysis of Modern Power Systems Using a Stochastic Hybrid Systems Framework

eess.SY eess.SP ·2026-11-10 ·Masoud H. Nazari, Hamid Varmazyari
published similarity 0.51
Abstract · This paper was accepted at the 2026 North American Power Symposium (NAPS)

This paper presents a cascading contingency analysis and risk assessment framework that incorporates probabilistic mode transitions motivated by stochastic hybrid system (SHS) concepts together with power-flow-based stress evaluation. A two-stage modeling approach is adopted in which sensitivity-based analysis is first used to identify candidate cascading transitions, followed by DC power flow re-evaluation to accurately capture post-contingency stress redistribution, islanding behavior, and load shedding. A probabilistic propagation model is constructed using mode-dependent transition probabilities derived from line loading conditions. A Cascading Risk Index (CRI) is introduced to quantify the expected load shedding accumulated over cascade progression. Case studies on the IEEE 39-bus system demonstrate that the proposed framework captures diverse cascading routes under multiple initiating outages and identifies critical propagation patterns that are not revealed by N-1/N-2 screening. The results highlight the importance of SHS modeling in assessing cascading risk and providing a scalable framework for resilience evaluation in modern power systems.

0.34

DC Voltage Control Dominated Oscillations in Electromechanical Frequency Range - Insights from Synchronous Coefficient Reduction Effect of IBR Plants and Network Interactions

eess.SY ·2026-11-09 ·Qiang Fu, Siqi Bu
top venue similarity 0.51
Abstract

Large-scale integration of inverter-based resources (IBRs) is widely known to cause subsynchronous oscillations. This paper investigates a distinct class of oscillations that occur in the electromechanical frequency range (EFR), referred to as EFOs, and are dominated by the DC voltage control (DVC) loops of grid-following IBRs rather than synchronous generator-like controls or phase-locked loops (PLLs). Although open-loop oscillation modes of DVC loops are subsynchronous, the corresponding closed-loop dominant oscillation mode related to DVC can shift downward into the EFR without retuning the control parameters. This frequency shift is caused by network-mediated interactions among the IBRs, which introduce a negative synchronous coefficient into the DVC oscillation loop. This synchronous coefficient reduction effect (SCRE) becomes stronger as the IBR plant scale increases and/or as the minimum eigenvalue of the network admittance matrix decreases. Furthermore, a complex vector-based stability analysis method is proposed, and a stability criterion for DVC-EFOs is derived. Finally, the analytical conclusions are validated using a practical power system configuration implemented in Simulink. The SCRE differs from traditional explanations, in which the open-loop oscillation modes are already located in the EFR, and provides new insight into DVC-dominated oscillations in the EFR for integration of IBR plants.

0.42

Grid-Aware Assessment of Forced Oscillations from Spatially Distributed Large Loads

eess.SY ·2026-11-17 ·Min-Seung Ko, Hao Zhu
similarity 0.49
Abstract

This paper develops a unified analytical framework for assessing forced oscillations induced by spatially distributed large-load fluctuations to determine their grid-aware fluctuation magnitudes. Emerging computational loads, such as hyperscale datacenters, present cyclic power variations with dynamic impacts depending on the waveform characteristics, forcing frequency, and source location. Our grid-aware framework represents these fluctuations using deterministic harmonic and probabilistic spectral models, and analyzes the resulting bus-wise frequency deviations based on a generic grid frequency-response model. Deterministic, risk-aware, and band-based probabilistic severity measures are further developed to obtain admissible fluctuation limits under different assumptions on frequency and phase uncertainty. We also formulate a security-constrained (SC) optimization of locational fluctuation magnitudes among existing large loads, accounting for their aggregated frequency deviation level. Case studies on the IEEE 39-bus and 14-generator Australian systems validate the proposed severity measures and admissible limit analysis. The SC optimization results further show that distributing a given amount of aggregate fluctuation toward dynamically less sensitive locations can substantially reduce system-wide oscillation severity.

0.34

On the Mechanism of Multi-Cluster System Separation Under Extreme Events

eess.SY ·2026-10-14 ·Nikolaos Sofos, Georgios Tzounas, Federico Milano
unusual similarity 0.49
Abstract

Historical blackout events demonstrate that, under complex multi-event contingencies, interconnected power systems can split into multiple areas exhibiting distinct dynamic behavior while remaining physically connected. This work provides a rationale for this phenomenon. Typical N-1 contingency analysis leads to a response dominated by a single unstable mode, supporting the two-cluster conjecture used by transient stability assessment tools such as the SIME method. However, extreme events, often involving cascading N-k contingencies, can excite multiple unstable modes. We establish a proof of concept based on linear modal expansion to show how such concurrent excitation leads to multiple coherent areas. The resulting behavior is illustrated through simulations on the standard WSCC 9-bus, IEEE 14-bus, and IEEE 39-bus systems, demonstrating the limitations of conventional two-cluster representations under extreme events.

0.24

Isostable-Based Nonlinear Model Reduction for Power System Oscillations

eess.SY math.DS ·2026-09-27 ·Kaiyang Huang, Dan Wilson, Kai Sun
similarity 0.48
Abstract

Power systems are often represented by high-dimensional dynamic models, making nonlinear control design computationally expensive and limiting its practical application. Oscillation analysis and damping control therefore commonly rely on linearized models, which do not capture the nonlinear oscillatory behavior induced by large disturbances. This paper proposes an isostable-based model reduction method for nonlinear modal analysis of power systems. The method constructs an invariant manifold associated with a selected oscillatory mode and uses isostable coordinates to describe the mode with only two real state variables. The isostable formulation gives linear autonomous modal dynamics, with nonlinear state reconstruction and input response computed on the modal manifold. An optimal damping control problem is then formulated directly in the reduced coordinates. Case studies on the IEEE 39-bus system demonstrate the accuracy of the proposed model in describing nonlinear oscillations and show improved damping compared with control designed using a linear reduced model.

0.38