CS Paper Radar

Spatiotemporal Recognition of Abdominal Wall Layers During Optical Trocar Entry

Shreeram Athreya, Andrew Melehy, Carter Prentice, Michael Robinson, Corey Arnold, James Wu, William Speier

cs.CV ·submitted 2026-10-10 03:19 UTC · v1
unusual

Abstract

Objective. To evaluate whether spatial context and temporal modeling improve tissue recognition during optical trocar entry, where multiple abdominal-wall tissues may be visible simultaneously. Methods. We retrospectively analyzed 71 recordings with 1,516 annotated keyframes and 29,151 clinician-annotated sectors. Each frame was divided into 28 polar-grid sectors assigned to nine tissue classes. Color, neighboring-sector, and positional features were used by a gradient-boosted emission classifier. The full pipeline added learned temporal smoothing, spatial regularization, an anatomically ordered hidden Markov model, and posterior blending. Five-fold cross-validation was grouped by recording, with cross-fitting to prevent within-recording leakage. Primary evaluation used clinician-derived targets; ablations assessed classification, probability quality, spatial consistency, and peritoneum-or-deeper onset timing. Results. The complete pipeline achieved accuracy 0.646, macro-F1 0.507, and macro-AUROC 0.882, versus 0.600, 0.440, and 0.861 for emissions alone. Macro-F1 improved by 0.066 across all five folds. Label changes decreased from 66.2 to 19.5 per sector-minute, and median onset error decreased from 15.58 to 2.45 seconds. Frames with a tissue-depth-code span of at least three decreased from 53% to 26%, versus 22% for clinician annotations. Performance remained limited for preperitoneal fat and bowel, and the full model retained a 44% premature-onset proportion. Conclusions. Combining appearance, spatial context, and temporal constraints improved retrospective tissue recognition and onset localization. Tissue-specific limitations, residual timing errors, and reliance on future observations warrant external validation and prospective evaluation of causal models before clinical use.

Comment
16 pages, 3 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Artificial Intelligence for Workflow Analysis in Colorectal Surgery: A Multicentric, Cross-Procedural Development and Generalization Study

cs.CV ·2026-08-20 ·Pietro Mascagni, Julia Alekseenko, Pooja P Jain, Marta Goglia, Andrea Balla +8 more
similarity 0.56
Abstract

Minimally invasive colorectal surgeries (MIS-CRS) are characterised by significant variability and inconsistent outcomes. ColoWorkflow, a tool for the video-based assessment (VBA) of MIS-CRS workflow, was recently validated. However, manual VBA is time-consuming, limiting implementation. This study presents AI-ColoWorkflow, a deep learning model for automated surgical workflow analysis across MIS-CRS. Operative videos of MIS-CRS were collected from 4 centres and a publicly available dataset. Phases and steps were manually annotated according to ColoWorkflow. A deep learning model combining a fine-tuned DINOv3 vision transformer for per-frame visual feature extraction with a hierarchical multi-stage temporal convolutional network was jointly optimized for phase and step recognition. The model trained on pooled multicentric data, namely AI-ColoWorkflow was compared against centre-specific and procedure-specific models on a held-out test set. The following metrics were used for evaluation: macro F1 score, balanced accuracy, precision, and recall. AI-ColoWorkflow achieved a macro F1 of 73.01% $\pm$ 10.27 (balanced accuracy 73.43%) for phase recognition and 39.82% $\pm$ 7.06 (balanced accuracy 38.65%) for step recognition. The global model outperformed centre- and procedure-specific models in most experiments except procedure-specific step recognition. In the generalization analysis, mean F1 was 48.42% for phase recognition. AI-ColoWorkflow can reliably recognize MIS-CRS phases. A single model trained on pooled, multicentric, multi-procedural data generalises at least as well as and often better than centre- or procedure-specific models for phase recognition in MIS-CRS, while procedure-specific step models retain advantages for certain procedure types, motivating hybrid training strategies for future surgical AI development.

0.22

Beyond Instrument Motion: Recognizing Tissue Tension Toward Surgical Skill Assessment

cs.CV ·2026-08-18 ·Marko Haralović, Zhiqi Miao, Alexander Machiel Bont, Jiapan Guo, Frans van Workum +1 more
publishedbenchmark similarity 0.56
Abstract · The paper is accepted by ECCV 2026 Workshop On Medical Video Understanding

Surgical performance assessment in minimally invasive surgery largely relies on manual expert review, making it time-consuming, subjective, and difficult to scale. While existing surgical video understanding methods address tasks such as instrument segmentation, surgical phase recognition, and action recognition, they do not explicitly capture fine-grained tissue handling, a key indicator of surgical quality. To address this gap, we introduce tissue tension recognition, a new clinically motivated video understanding task for laparoscopic and robot-assisted rectal cancer surgery. To support this task, we construct SurgTension, the first expert-annotated tissue tension dataset, providing a benchmark for objective tissue tension recognition. We further propose TensionTRAC, a lightweight trajectory-based framework that models tissue tension from sparse point trajectories. Using a compact trajectory encoder, TensionTRAC achieves competitive performance against strong pretrained video backbones.

0.33

Lesion-centered 3D mapping of colonoscopy procedures: validation of a hierarchical ensemble pipeline on public benchmark videos

cs.CV ·2026-09-15 ·Hyunjun Kim, Hyeonwoo Na, Jaewoo Lee
benchmarkcode/data similarity 0.56
Abstract · 21 pages, 12 figures, 4 tables. Code: github.com/hyunjun1121/endovision-pipeline (Zenodo DOI 10.5281/zenodo.22136766)

Background and Objective: Colonoscopy recording practice preserves text reports and still photographs, while the spatial information already present in the recorded video - where the scope traveled, where a lesion was observed, and whether the same lesion was seen again - is discarded when the procedure ends. This study determines whether a lesion-centered spatial record can be assembled and validated without full-colon 3D reconstruction. Methods: A four-layer hierarchical pipeline was assembled - (1) a global topological map, (2) lesion-level spatio-temporal tracks, (3) on-demand local 3D reconstruction, and (4) persistent lesion identity across repeated observations - and ran end to end on four public videos (two C3VDv2 sequences with ground-truth depth and two full REAL-Colon procedures; 40,245 frames). All components are published, individually validated methods; the contribution is their lesion-centered assembly, linking rules, and evaluation. Results: Revisits, impossible under forward-only mapping by construction, were detected by entry-map Bayesian localization: 5,614 and 4,043 revisit events (56 and 68 distinct nodes) in the two full procedures. Lesion-identity merging at the adopted threshold 0.5 maintained ground-truth purity 1.0 while auto-merging 20 of 231 candidate pairs. The endoscopy-specific geometry engine outperformed a general-purpose foundation model on all metrics (overall absolute relative error (AbsRel) 0.2276 vs. 0.3523). Conclusions: The results are partial but establish a concrete near-term path: revisit detection, lesion identity, and local 3D each returned quantitative, reproducible output without waiting for complete geometric reconstruction; validating the record on clinical data is the next step.

0.52

Evaluating the Effects of Inter-Observer and Model Variability on Radiological Peritoneal Cancer Index Assessment

eess.IV cs.CV ·2026-08-28 ·Savvas Saragiotis, Pieter C. Gort, Lotte J. S. Fleurkens-Ewals, Anna F. van Herwijnen, Marion Tops-Welten +3 more
published similarity 0.55
Abstract · Accepted as a CaPTion workshop paper at MICCAI 2026

Deep learning segmentation models are often evaluated using geometric metrics such as Dice, HD95, and ASD, yet it remains unclear to what extent improvements in these metrics translate into clinically meaningful changes in downstream decision-making. The metric-to-decision gap is examined using radiological Peritoneal Cancer Index (rPCI) region segmentation on contrast-enhanced CT, where a consensus definition provides anatomically grounded 3D regions and the clinically used PCI 20 threshold enables decision-level evaluation. Inter-observer variability is quantified across four experts on ten abdominal CT scans, and a published nnU-Net based rPCI segmentation model is benchmarked against this human reference using Dice, HD95, and ASD across all 13 regions. To relate geometric differences to clinical impact, a probabilistic peritoneal metastasis simulation is implemented on majority-vote rPCI maps, propagating region-boundary variability into variability of derived (r)PCI scores and classification at the PCI 20 cutoff. Observers showed high agreement (mean Dice $0.87$), while the model matched human performance in most regions but deviated more in regions 4, 8, and the small-bowel regions (9-12). Across simulations, score differences were typically small (mean $Δ$rPCI $\approx 0.3$-$0.6$) for both observers and the model, and decision flips occurred predominantly when the reference score was near 20. These results suggest that rPCI-derived scoring is generally robust to typical segmentation variability, while highlighting borderline cases as the main setting where expert review remains essential.

0.40

SurgCBVR: A Multi-Domain Benchmark for Content-Based Surgical Video-to-Video Retrieval

eess.IV cs.AI ·2026-11-17 ·Mohammad Eslami, Mousa Moradi, Negin Ghamsarian, Nazlee Zebardast, Jennifer L Lindsey +4 more
benchmark similarity 0.55
Abstract

Hospitals record thousands of hours of surgical video annually, yet these archives remain difficult to search by content. Surgeons cannot readily retrieve similar operations, complications, or workflow events. Existing surgical computer vision primarily produces labels rather than retrieving relevant videos. We introduce SurgCBVR, the first benchmark for content-based video-to-video retrieval in surgery. It integrates eight public datasets across four domains-ophthalmic, laparoscopic, robotic-assisted, and colonoscopy-covering six procedure types, 679 cases, and 76,489 clips (106 hours). SurgCBVR comprises two tiers: Scene, retrieving the same operative state across cases and sites, and Workflow, retrieving and localizing phase transitions and deviations. Scene includes 74,765 clips spanning 40 classes, three temporal granularities, and three playback speeds; Workflow contains 1,724 transition clips. Fixed clip lengths and frame counts, together with phase-classifier oracle and duration-only baselines, help assess label and timing shortcuts. We evaluate six generic and surgical foundation models, two video retrieval methods, and contrastive heads trained on SurgCBVR, using within-dataset, cross-dataset, and pooled-gallery retrieval restricted to the same procedure type. Frozen representations barely outperform a timing-only baseline, transition retrieval approaches chance, and trained heads lose up to half their accuracy across datasets. These findings expose substantial limitations in current video representations and establish SurgCBVR as a benchmark for advancing surgery-aware retrieval.

0.21

Colorectal Cancer Segmentation with Adaptive Augmentation and Multi-Resolution Ensemble Models

eess.IV cs.AIcs.CV ·2026-09-29 ·Ümit Mert Çağlar, Alptekin Temizel
publishedcode/data similarity 0.54
Abstract · SPIE Eighteenth International Conference on Machine Vision (ICMV 2025), Paris, France

Colorectal cancer (CRC) is the second most deadly and third most common cancer, and the leading cause of death among gastrointestinal cancers. Early diagnosis is crucial for the treatment of this cancer and increasing the survival rates. Although CRC is more common in developed regions, its occurrence is also increasing in developing regions as well. CRC diagnosis relies on histopathology assessment post-biopsy. Automated deep learning algorithms can significantly reduce diagnosis time, enhancing efficiency and supporting timely clinical decisions. We present an automated segmentation pipeline for whole-slide histopathology images that labels tumor grades 1-3 and normal mucosa. It utilizes dense prediction transformers with various encoder backbones, overlapping patches, and test-time augmentation. An adaptive augmentation policy, guided by large language models, further improves training. Top models were ensembled via soft voting, and mask refining post-processing steps, Gaussian blurring, morphological closing, and connected components analysis. On a colorectal cancer grade dataset, our method improved the F1 score from 62.92 to 69.84. Code is available here: github.com/caglarmert/ICIP2025

0.34

Improving Clinical Target Volume Segmentation Accuracy using Anatomical Priors and Active Learning for the AGITG TOPGEAR Clinical Trial

cs.CV physics.med-ph ·2026-09-02 ·Phillip Chlap, Mark Lee, Trevor Leong, Matthew Field, Jason Dowling +9 more
similarity 0.54
Abstract

Training deep learning-based medical image segmentation models is challenging with limited curated datasets. For AGITG TOPGEAR, a gastric cancer trial, the Clinical Target Volume (CTV) is complex and defined by multiple anatomical landmarks, making upfront training data preparation difficult for an automated contour QA segmentation model. We investigate anatomical priors, derived from surrounding organ segmentations, to provide spatial context and improve TOPGEAR CTV segmentation accuracy. We also evaluate active learning, iteratively expanding the training dataset by selecting cases expected to improve performance. One hundred TOPGEAR CT scans were retrospectively analyzed. An initial set of 10 expert-contoured cases was used to train an nnU-Net model. TotalSegmentator generated a voxel-wise anatomical prior map from surrounding structures as an additional input channel. Active learning was simulated over four iterations, selecting cases by model uncertainty and segmentation performance. All models used five-fold cross-validation for an ensemble uncertainty measure. Evaluation used a hold-out testing set of 50 cases. The anatomical prior improved CTV segmentation accuracy, increasing mean Dice Similarity Coefficient (DSC) from 0.84 to 0.86. Active learning similarly improved performance to 0.86, with greatest benefit in the final round. Combining the anatomical prior with active learning achieved the highest accuracy, with a DSC of 0.87. Model uncertainty correlated with DSC, supporting its use in identifying suboptimal predictions and guiding active learning. Anatomical priors and active learning each improved CTV segmentation accuracy and generalizability, with their combination achieving the best performance, supporting integration into segmentation model development for automated contour QA in radiotherapy clinical trials.

0.16

Video Based Assessment of Surgical Skills Using Frozen Pretrained Video Foundation Models

eess.IV ·2026-09-17 ·Sangrock Lee, FNU Rahul, Suvranu De
publishedbenchmark similarity 0.53
Abstract · Accepted for publication in npj Digital Medicine

Automated video-based surgical skill assessment has advanced rapidly, yet rigorous evaluation of continuous standardized score prediction under participant-level generalization to unseen trainees remains limited. We introduce VBA-Net+, a video-only framework for Fundamentals of Laparoscopic Surgery (FLS) score regression and pass-fail classification using pretrained video foundation models as frozen feature extractors. We evaluate two FLS datasets, suturing and pattern cutting, using VideoPrism, V-JEPA2, and VideoMAE v2, with a frame-level SimCLR baseline. A lightweight fully convolutional head is trained on embeddings offline and evaluated using participant-level leave-one-user-out (LOUO) cross-validation within the standardized assessment protocol. For continuous score prediction, the best representation achieves $R^2$=0.6367 for suturing and 0.9261 for pattern cutting. For pass-fail classification at official FLS thresholds, area under the receiver operating characteristic curve (AUC) reaches 0.9073 and 0.9906, respectively. Frozen video-encoder pipelines generally outperformed the frame-level SimCLR pipeline, particularly for suturing, providing a benchmark for video-only FLS assessment.

0.24