CS Paper Radar

Fast Analytical Method for Resource Adequacy Assessment in Renewable-Rich Power Systems

Seyed Amir Hosseini, Mohammad Reza Karimi Gharigh, Antonello Monti, Peter Palensky, Saeed Peyghami

eess.SY ·submitted 2026-10-13 12:30 UTC · v1
theory

Abstract

This paper proposes a novel analytical method for resource adequacy assessment in renewable rich power systems. The approach begins by applying the stress strength method to estimate two key resource adequacy indices: loss of load expectation (LOLE) and expected energy not supplied (EENS). This method requires defining the probability distribution functions (PDFs) for both the generation side and the load side. The load is assumed to follow a normal probability distribution, while the generation side probability distribution is derived from the combined PDFs of conventional, wind, and solar power sources. The approach models the cumulative impact of uncertainties on resource adequacy using the central limit theorem (CLT), and improves accuracy with a cumulant based Gram Charlier expansion when the CLT alone is insufficient. The effectiveness of the proposed method is validated through Monte Carlo simulations conducted on the IEEE single area and multi-area RTS-96 test systems. The results demonstrate that the proposed method achieves a substantial reduction in computational time, which is crucial in the context of operational planning, without sacrificing accuracy. Furthermore, its performance improves as renewable penetration increases, making it particularly suitable for future power systems operation and planning.

Closest papers

Nearest neighbours by meaning across the whole index.

New and Improved Analytical Methods for Calculating Power System Adequacy Metrics

eess.SY ·2026-10-04 ·Chanan Singh
similarity 0.62
Abstract

A new analytical technique is proposed for calculating adequacy metrics for generation planning. The proposed technique is simple, direct, and provides higher accuracy than traditional discretized approaches. Additionally, a new analytical methodology is introduced for calculating loss of load days (LOL Days) as distinct from loss of load events or frequency of load loss. This paper emphasizes that, where feasible, analytical methods are preferable to Monte Carlo simulations because they yield exact closed-form solutions rather than statistical estimates.

0.25

Reliability Value of Long-Duration Energy Storage against Extreme Events in High-Renewable Grids: A Full-Year AC-OPF Assessment

eess.SY ·2026-09-06 ·Jeongdong Kim, Jonggeol Na, Sungho Shin
similarity 0.61
Abstract · 39 pages, 12 figures

Long-duration energy storage (LDES) can mitigate prolonged renewable--load imbalances during Dunkelflaute events, but existing studies rely on zonal or linearized DC network models and inadequately analyze the operational feasibility of the grid across a wide range of full-year renewable, load, and contingency scenarios. To address this gap, this paper introduces a multi-period alternating-current optimal power flow (AC-OPF) formulation that captures the full nonlinear network physics and assesses the reliability value of LDES in high-renewable grids. To evaluate scarcity events spanning multiple days to weeks, full-year operation is modeled as an 8,760-h load-shedding minimization over scenarios sampled from a Gaussian copula model, fitted to 2010--2025 historical wind and bus-level load data, that represents both typical variability and tail events. On a synthetic 200-bus Illinois transmission network, a hybrid fleet of battery energy storage (BESS) and LDES with 50 MW total power reduces annual load shedding by 83.0% on average relative to the base network, versus 68.5% for short-duration BESS alone at equal power. To further account for unexpected line outages throughout the year, the formulation is extended to a multi-day security-constrained AC-OPF. Under N-1contingencies, no feasible operating solution is obtained for the base network, whereas the LDES-equipped network remains feasible in all considered cases, thereby saving the cost of additional generation and transmission capacity. During the contingency period, LDES acts as a backup power supply, requiring only 5.5% more generation on average than the no-contingency base case.

0.21

On the Concept of an Optimal Portfolio of Uncertain Flexible Loads

eess.SY ·2026-09-04 ·Julie Rousseau, Philipp Heer, Kristina Orehounig, Gabriela Hug
published similarity 0.59
Abstract · Accepted to the 2026 PowerUp conference

Flexible loads can enhance power system stability by providing reserves, but their limited energy capacity and uncertain availability distinguish them from conventional generators. To accommodate these characteristics, the Danish Transmission System Operator (TSO) recently introduced new reserve market rules that incorporate energy constraints and relax reliability requirements. In this context, the optimal reserve quantification becomes a joint chance-constrained reserve quantification problem, which is difficult to solve. In this paper, we derive two analytical reformulations of this problem: an exact one when a reserve direction dominates and an approximate one, otherwise. Furthermore, when flexible loads must collectively satisfy a reliability requirement, we introduce the concept of an optimal portfolio of flexible loads: adding loads with similar expected values but different stochastic behaviors to an existing portfolio may change the total portfolio's reserves. To support this idea, we theoretically study the marginal increase in reserves resulting from adding a load. Numerical results show that our analytical reformulations closely match the exact formulation, with a mean absolute error of 2.5%. Case studies further demonstrate the existence of optimal load groupings and our ability to predict the portfolio in which a load's marginal value is highest, leveraging our theoretical analysis.

0.43

Which wind and solar modelling choices matter? Effects on capacity factors, energy droughts and European power system configuration

eess.SY ·2026-10-29 ·L. Karkossa, A. Grochowicz, M. J. Koivisto, A. Hahmann, M. VIctoria
similarity 0.58
Abstract

Europe's future power system will rely heavily on wind and solar power and must remain resilient during prolonged periods of low wind and solar generation, known as variable renewable energy (VRE) droughts. To capture such rare events, adequacy assessments increasingly draw on decades of weather data, but the conversion of weather into power is largely treated as fixed. It remains unclear which modelling choices in this conversion matter for representing these droughts, and whether they matter as much as the weather itself. Here we systematically compare these choices side by side (bias correction, wind speed extrapolation, capacity layouts, turbine and photovoltaic configurations, and wake losses) and trace their effects through VRE droughts to the design of a net-zero European power system, using 85 years of reanalysis data. We find that modelling choices barely change how often VRE droughts occur or when the system is stressed. They do, however, determine how much capacity is needed to withstand that stress. By altering the electricity delivered during droughts, they shift required capacity by up to 480 GW, which is comparable to the spread across the most critical weather years. Modelling exercises should therefore use multiple weather years; bias-correct and regionally validate weather inputs; explicitly represent resource heterogeneity, forward-looking technologies, and wake losses; and judge these choices by their effect on the low-generation tail, not only on the mean.

0.24

Long-Term Operational Planning Using Scenario-Based System Load Forecasting

cs.CR ·2026-09-28 ·Akash Debnath, Shiuli Subhra Ghosh, Jaime De La Ree, Alex Freeman, Kavin D Jones
similarity 0.56
Abstract

The rapid expansion of hyperscale data centers is significantly increasing electricity demand in Northern Virginia. Dominion Energy, the region's primary electric utility, must reinforce its transmission network to support this growth. These projects require planned outages that must be evaluated months in advance to support construction planning and outage coordination while meeting NERC and PJM N-1 reliability requirements. Long-term outage studies are commonly performed day by day using monthly or seasonal peak-load assumptions. Although this approach simplifies analysis, it can be overly conservative because it does not capture granular load variability. Consequently, short-duration outages that may be feasible under realistic loading conditions are often postponed or denied, delaying critical transmission expansion and grid modernization projects. This paper evaluates the operational value of incorporating realistic multigranular load forecasts into long-term, contingency-based outage assessments and compares the results with conventional peak-based methods. Daily, weekly, and monthly forecasts are developed using statistical and machine-learning models, including SARIMA, Prophet, Gradient Boosting, and Random Forest, followed by bottom-up temporal reconciliation to maintain consistency across forecast horizons. Results show that granular load forecasts reduce unnecessary conservatism and improve outage accommodation, particularly for short-duration requests, without changing existing reliability criteria. The proposed approach can strengthen long-term outage coordination and support timely transmission reinforcement and grid modernization.

0.20

Efficient Quantile-Resolved Hosting Capacity Assessment on Nodal Level for Low-Voltage Grids

eess.SY ·2026-09-08 ·Maximilian Köhler, Edwin Mora, Mathias Duckheim, Stefan Niessen
similarity 0.56
Abstract · Submitted to IEEE PES ISGT Europe 2026. 5 pages, 3 figures. Keywords: Hosting Capacity, Uncertainty, Distribution Grid, Distributed Energy R…

Hosting capacity - the maximum additional capacity a network can accommodate without violating operational limits - is a key metric in distribution system planning and operation. Decisions on grid reinforcements and the deployment of flexibility management require not only the worst-case HC but also an understanding of the distribution of HC under different likelihoods in load and generation patterns. Quantile-resolved HC distributions provide this view by expressing HC as a function of an acceptable operational limit exceedance likelihood. Monte Carlo sampling is the established approach for computing such distributions but demands large computational resources. Approximations sacrifice either accuracy, the ability to capture uncertainty correlations, or scalability when assessing real-world networks. This paper introduces a computationally efficient method for calculating distributions for quantile-resolved HC. It uses a representation of load samples as multivariate normal distribution, propagated through a linearized power flow model. This allows for leveraging a re-parametrized AC-OPF problem for each hosting capacity quantile. Benchmarking against Monte Carlo-based methods on realistic LV networks demonstrates that the proposed method achieves comparable accuracy with a mean deviation of approx. 3%, while reducing computational time by orders of magnitude. For the exemplary networks the computational time decreases from 11 min to 2 s, and 38 h to 50 s, respectively. The method's scalability is also suitable for recalculation in 15-minute cycles encountered in DSO practice for e.g., real-time grid management.

0.21

Probabilistic electrical power demand forecasting with uncertainty quantification

cs.LG cs.AI ·2026-09-28 ·Mahesh Neupane, Pragya Dhungana, Pradip Khatri, Swechhya Baskota, Hariom Dhungana
similarity 0.56
Abstract

The majority of research on electricity consumption forecasting has focused on deterministic approaches, which generate a single point estimate for each time step in the forecasting horizon. However, the increasing penetration of renewable energy sources and the growing complexity of modern smart grids have introduced greater variability and uncertainty into power-system demand and operation. Consequently, probabilistic forecasting, which quantifies the uncertainty and variability associated with future electricity demand, is becoming increasingly important for reliable power-system planning and operation. This study presents an empirical comparison of four contemporary probabilistic forecasting models for electricity consumption, highlighting their respective strengths and limitations. We have performed comparision on real-world power systems related datasets. Across all power-consumption zones, NGBoost demonstrates superior probabilistic forecasting performance, achieving the lowest MAE and RMSE while providing well-calibrated uncertainty estimates with high prediction-interval coverage and reasonably narrow intervals. These results indicate that NGBoost offers a more accurate and reliable forecasting framework than Bayesian, Monte Carlo (MC) Dropout, and Gaussian Process Regression (GPR) models for the considered electricity consumption data.

0.16

A multi-stage probabilistic framework to estimate gas-fired generator performance during extreme winter weather

cs.LG stat.ML ·2026-10-03 ·Sajjad Uddin Mahmud, Anamika Dubey
similarity 0.55
Abstract

Extreme winter weather has repeatedly disrupted gas-fired power generation in the United States, yet the plant-level data needed to systematically quantify outage risk remain proprietary. Using publicly available weather and electricity demand data together with anonymized generator contingency records from the North American Electric Reliability Corporation (NERC), we develop a three-stage Bayesian probabilistic framework for estimating winter-driven generator performance. Applied to New York State (2013--2022), the framework sequentially estimates: the hourly probability of a generator contingency event, the expected net available capacity conditioned on an event occurring, and the event duration. Colder conditions and higher electricity demand are associated with higher failure probability, lower retained capacity, and longer event duration. Under the most severe observed stress conditions, estimated mean hourly event probability reaches 24\% , while expected mean net available capacity falls to 13\% of nameplate rating. Full outage events have a median duration of 12.7 hours, while partial derating event duration increases from 2.4 to 7.1 hours with capacity loss severity. The proposed framework establishes a transferable baseline that utilities with access to plant-level records can directly extend to obtain more precise reliability estimates for operational planning and resource adequacy assessment.

0.24