CS Paper Radar

New and Improved Analytical Methods for Calculating Power System Adequacy Metrics

Chanan Singh

eess.SY ·submitted 2026-10-04 20:23 UTC · v1

Abstract

A new analytical technique is proposed for calculating adequacy metrics for generation planning. The proposed technique is simple, direct, and provides higher accuracy than traditional discretized approaches. Additionally, a new analytical methodology is introduced for calculating loss of load days (LOL Days) as distinct from loss of load events or frequency of load loss. This paper emphasizes that, where feasible, analytical methods are preferable to Monte Carlo simulations because they yield exact closed-form solutions rather than statistical estimates.

Closest papers

Nearest neighbours by meaning across the whole index.

Fast Analytical Method for Resource Adequacy Assessment in Renewable-Rich Power Systems

eess.SY ·2026-10-13 ·Seyed Amir Hosseini, Mohammad Reza Karimi Gharigh, Antonello Monti, Peter Palensky, Saeed Peyghami
theory similarity 0.62
Abstract

This paper proposes a novel analytical method for resource adequacy assessment in renewable rich power systems. The approach begins by applying the stress strength method to estimate two key resource adequacy indices: loss of load expectation (LOLE) and expected energy not supplied (EENS). This method requires defining the probability distribution functions (PDFs) for both the generation side and the load side. The load is assumed to follow a normal probability distribution, while the generation side probability distribution is derived from the combined PDFs of conventional, wind, and solar power sources. The approach models the cumulative impact of uncertainties on resource adequacy using the central limit theorem (CLT), and improves accuracy with a cumulant based Gram Charlier expansion when the CLT alone is insufficient. The effectiveness of the proposed method is validated through Monte Carlo simulations conducted on the IEEE single area and multi-area RTS-96 test systems. The results demonstrate that the proposed method achieves a substantial reduction in computational time, which is crucial in the context of operational planning, without sacrificing accuracy. Furthermore, its performance improves as renewable penetration increases, making it particularly suitable for future power systems operation and planning.

0.20

A New Analytical Method and Interpretation of Loss-of-Load Counts

eess.SY ·2026-11-12 ·Aidan Looney, Chanan Singh, Le Xie
similarity 0.57
Abstract · 5 pages, 3 figures, 1 table, submitted to IEEE PESGM

This paper establishes the relationship between loss-of-load expectation (LOLE) and loss-of-load frequency (LOLF). We show why LOLE generally does not measure distinct-event frequency, mean event duration, or shortage magnitude. We identify conditions under which peak-based LOLE admits a frequency interpretation as the expected count of deficient daily peaks per horizon and distinguish this quantity from LOLF. We also derive an analytical formulation for frequency-and-duration indices that combines a convolution-derived generation probability-and-frequency model with chronological load changes. Under stationary generation, it uses the prescribed load profile directly, without constructing a separate load model or discretizing load magnitudes. Studies using generation and load data from the 24-bus IEEE RTS reveal different event frequencies and mean event durations at identical peak-based LOLE, motivating their separate assessment. Numerical comparisons demonstrate the accuracy advantage of the proposed analytical calculation over the conventional analytical implementations, quantifying the LOLF errors incurred by load discretization.

0.23

Efficient Quantile-Resolved Hosting Capacity Assessment on Nodal Level for Low-Voltage Grids

eess.SY ·2026-09-08 ·Maximilian Köhler, Edwin Mora, Mathias Duckheim, Stefan Niessen
similarity 0.55
Abstract · Submitted to IEEE PES ISGT Europe 2026. 5 pages, 3 figures. Keywords: Hosting Capacity, Uncertainty, Distribution Grid, Distributed Energy R…

Hosting capacity - the maximum additional capacity a network can accommodate without violating operational limits - is a key metric in distribution system planning and operation. Decisions on grid reinforcements and the deployment of flexibility management require not only the worst-case HC but also an understanding of the distribution of HC under different likelihoods in load and generation patterns. Quantile-resolved HC distributions provide this view by expressing HC as a function of an acceptable operational limit exceedance likelihood. Monte Carlo sampling is the established approach for computing such distributions but demands large computational resources. Approximations sacrifice either accuracy, the ability to capture uncertainty correlations, or scalability when assessing real-world networks. This paper introduces a computationally efficient method for calculating distributions for quantile-resolved HC. It uses a representation of load samples as multivariate normal distribution, propagated through a linearized power flow model. This allows for leveraging a re-parametrized AC-OPF problem for each hosting capacity quantile. Benchmarking against Monte Carlo-based methods on realistic LV networks demonstrates that the proposed method achieves comparable accuracy with a mean deviation of approx. 3%, while reducing computational time by orders of magnitude. For the exemplary networks the computational time decreases from 11 min to 2 s, and 38 h to 50 s, respectively. The method's scalability is also suitable for recalculation in 15-minute cycles encountered in DSO practice for e.g., real-time grid management.

0.21

Cascading Contingency Analysis of Modern Power Systems Using a Stochastic Hybrid Systems Framework

eess.SY eess.SP ·2026-11-10 ·Masoud H. Nazari, Hamid Varmazyari
published similarity 0.53
Abstract · This paper was accepted at the 2026 North American Power Symposium (NAPS)

This paper presents a cascading contingency analysis and risk assessment framework that incorporates probabilistic mode transitions motivated by stochastic hybrid system (SHS) concepts together with power-flow-based stress evaluation. A two-stage modeling approach is adopted in which sensitivity-based analysis is first used to identify candidate cascading transitions, followed by DC power flow re-evaluation to accurately capture post-contingency stress redistribution, islanding behavior, and load shedding. A probabilistic propagation model is constructed using mode-dependent transition probabilities derived from line loading conditions. A Cascading Risk Index (CRI) is introduced to quantify the expected load shedding accumulated over cascade progression. Case studies on the IEEE 39-bus system demonstrate that the proposed framework captures diverse cascading routes under multiple initiating outages and identifies critical propagation patterns that are not revealed by N-1/N-2 screening. The results highlight the importance of SHS modeling in assessing cascading risk and providing a scalable framework for resilience evaluation in modern power systems.

0.43

Fast Reassessment of Prolonged Electricity Shortages under Shared Fuel Interruptions

eess.SY ·2026-10-19 ·Dogan Urgun
code/data similarity 0.53
Abstract · 11 pages, 4 figures, 5 tables. Submitted to IEEE Transactions on Reliability. Code and data: https://github.com/DoganUrgun/Fast_Reassessment…

When several generators share a fuel supply, one interruption can disable them together and cause electricity shortages lasting days. Such interruptions can be made less frequent, for example by weatherizing gas supply, or shorter, for example by on-site backup fuel. Yet traditional resource adequacy indices, expected unserved energy and loss-of-load hours, fail to distinguish such measures whenever they remove the same expected time without fuel, because for interruptions independent of system conditions these indices depend on the interruptions only through this time. Their difference is revealed by prolonged-shortage exposure, the expected annual hours in shortages of at least a given duration, whose exact chronological calculation must be repeated for every interruption scenario. To reduce this cost, a fast reassessment method with guaranteed accuracy is proposed. Network calculations are performed once and condensed into a restoration response, the additional prolonged-shortage hours caused by one interruption of each duration, from which any scenario is evaluated as a weighted sum without new simulation. An hour-by-hour error bound determines whether this evaluation is accurate enough, and exact dynamic programming is applied otherwise, so that every result lies within a requested tolerance of the exact value on the same Monte Carlo samples. On the Reliability Test System of the Grid Modernization Laboratory Consortium, most evaluations were accepted, fully accepted scenarios typically ran more than 200 times faster than exact calculation, and total computation time decreased in every workload. Measures against fuel interruptions can thus be screened quickly and accurately by their effect on prolonged shortages.

0.37

Approximating Energy-Regulation Feasible Region of Virtual Power Plants: A Data-driven Inverse Optimization Approach

eess.SY math.OC ·2026-08-26 ·Ruike Lyu, Hongye Guo, Qixin Chen
publishedhighly cited similarity 0.53
Abstract · Published in: 2024 IEEE Power & Energy Society General Meeting (PESGM)

System operators will probably allow virtual power plants (VPPs) to submit their feasible region (FR) for market clearing and dispatch. A VPP needs to determine its FR to submit as a whole based on the individual operation model of its internal distributed energy resources (DERs), which is an FR aggregation problem. Existing FR aggregation approaches rely on analytical methods, which have issues with generality and adaptability. In this paper, we propose a data-driven approach to approximate the energy-regulation FR of VPPs. It adopts the virtual battery model to approximate the aggregate FR of a VPP and determines the model parameters through inverse optimization based on generated multi-scenario operation data using the original operation model. Numerical tests verified the accuracy of the proposed method. We believe that our work helps to better leverage the flexibility of DERs.

0.63

On the Convexity of Common Resource Adequacy and Capacity Accreditation Metrics

eess.SY ·2026-11-03 ·Gord Stephen
similarity 0.52
Abstract

Many emerging capacity expansion optimization formulations implicitly presume the convexity (or concavity) of power system adequacy risk (or capacity accreditation) metrics. These assumptions have yet to be formally justified. We present concise mathematical proofs validating the claim for certain metrics (expected unserved energy and effective load carrying capability), but also provide simple invalidating counterexamples for others (loss-of-load expectation and equivalent firm capacity). Formulations built on non-convex (non-concave) metrics structurally undervalue candidate portfolio adequacy, and so cannot claim to produce least-cost expansion plans.

0.25

Relationship between Loss of Load Expectation and Frequency of Load Loss Events

eess.SY ·2026-09-18 ·Chanan Singh
unusual similarity 0.51
Abstract

Loss of Load Expectation (LOLE), originally calculated as the expected number of days of load loss, has also been used as a frequency metric. This paper shows that LOLE can indeed be calculated as a frequency metric, but only with restricted conditions, and that it differs fundamentally from the standard frequency metric employed in the frequency and duration (F&D) approach. A lack of understanding of these conditions can lead to incorrect applications and interpretations.

0.24