CS Paper Radar

Sounds Cheesy - Bridging the Texture Gap Between Dairy and Plant-Based cheese with Non-Contact Ultrasound and AI

Wenjing Feng, Thomas A. Hazlehurst, Nik Watson

cs.CE ·submitted 2026-10-14 10:14 UTC · v1
unusual

Abstract

Plant-based cheeses often fail to reproduce the texture of dairy cheese. Closing this gap is slow because the reference methods, texture profile analysis (TPA) and sensory panels, destroy the sample and are poorly suited to screening many formulations in a timely and cost-effective manner. Here we show that non-contact, air-coupled ultrasonic imaging combined with machine learning can characterise cheese texture rapidly and without damaging the sample. Thirteen commercial products (nine dairy, four plant-based; 119 slices, 357 scans) were imaged in through-transmission at 100 kHz to give two-channel amplitude and time-of-flight C-scans, and each slice was then measured by TPA. The C-scans revealed millimetre-scale acoustic domains in ripened dairy cheeses, consistent with their fused-curd microstructure, that were absent from the homogeneous starch and oil matrix of the plant-based products. TPA showed that the texture gap is one of range and failure behaviour rather than average firmness. Mean hardness was similar for the two categories, but dairy products spanned a 7.5-fold range against 1.9-fold for plant-based products, and the plant-based products failed in a brittle, strain-softening manner rather than by ductile yielding. No single ultrasonic parameter tracked texture across products. However, a compact convolutional neural network predicted full true stress-strain loading and unloading curves from the C-scan images of unseen slices across all thirteen products without product-specific calibration. Clustering the predicted curves produced a texture map on which three plant-based slices sat with the Cheddars and one with Emmental, while soft, mozzarella-like textures remained unoccupied. The approach offers a one-minute, non-contact measurement suited to formulation screening and at-line quality control of cheese.

Closest papers

Nearest neighbours by meaning across the whole index.

Hear What You Eat: In-Ear Passive Acoustic Sensing for Multi-task Dietary Monitoring

cs.HC ·2026-11-11 ·Feiyu Han, Mingtian Zhu, Dawei Yan, Weiwei Jiang, Yuanhao Feng +2 more
similarity 0.46
Abstract

The increasing obesity health concerns are driving the advancement of continuous dietary monitoring. Yet, existing single-sensor solutions still face challenges of coarse-grained sensing resolution, while multi-sensor fusion strategies encounter significant engineering complexity or hardware requirements. In our work, we present a single modality-based multi-dimensional dietary monitoring and logging solution, named EARDIET, which leverages inward-facing microphones on earables to capture in-ear chewing sounds for fine-grained diet analysis. With the texture audio profiles derivation, the pipeline consisting of signal processing and lightweight deep learning, is carefully designed to achieve eating episode detection, food texture sensing, and food type recognition simultaneously. Comprehensive experiments involving 32 participants with diverse BMI profiles are conducted to validate the effectiveness of multi-dimensional dietary monitoring. Compared with the state-of-the-art solutions, EARDIET can derive multi-dimensional dietary information with only a single modality, outperforming by about 10% in terms of eating episode detection. Furthermore, through real-world clinical validation, our solution can achieve masticatory disorder identification with an averaged F1-score of 85.97%, demonstrating potential for healthcare in the future.

0.26

Differentiable Co-Design of Ultrasound Probe Geometry and Acquisition for Plane-Wave Imaging

eess.SP ·2026-10-12 ·Somashekhar Dehury, Mahesh Raveendranatha Panicker
code/data similarity 0.45
Abstract · 11 pages, 4 figures, 2 tables. Code: https://github.com/sdehury34/jax-ultrasound-codesign . Interactive demo: https://pulseecho.in/demos/dif…

Ultrasound image quality depends on both the probe geometry and the transmit and receive processing, but engineers usually design the two separately. Physics-based simulators (Field II, k-Wave, MUST/SIMUS) compute the radio-frequency channel data but give no gradients, so design studies must use grid or black-box searches that become slow as the number of parameters increases. We present a fully differentiable end-to-end pipeline for plane-wave ultrasound imaging, with synthetic speckle phantoms, an analytical frequency-domain RF simulator, delay-and-sum beamforming and an extensible image-quality objective. The element pitch, the transmit and receive apodization and the global speed of sound are differentiable parameters of one computation graph, so one reverse-mode pass gives their exact joint gradients. Studies of each parameter rank the design parameters: the optimized pitch decreases the grating lobes, and the speed-of-sound autofocus gives clear contrast and resolution gains. Over 15 test phantoms, the optimized pitch increases the cyst gCNR from 0.55 to 0.66 (about 20%), and the speed-of-sound correction adds a further 0.05. The lateral point-spread function agrees with Field II within about 10%, and on 49 real CUBDL plane-wave acquisitions from five institutions, the framework finds the global speed of sound with a mean absolute difference of 16.6 m/s from the published corrections and phantom speed of sound.

0.35

Pulse-Echo Ultrasound Methods for Speed-of-Sound Estimation: A Review

eess.IV physics.med-ph ·2026-08-23 ·Can Deniz Bezek, Orcun Goksel
survey similarity 0.45
Abstract

Speed of sound (SoS) is fundamental to ultrasound beamforming and a promising quantitative biomarker for tissue characterization. Although transmission- and reflector-based methods have demonstrated the diagnostic value of SoS, their need for dedicated hardware or constrained acquisition geometries limits clinical usability. Pulse-echo SoS imaging addresses these limitations by estimating SoS with conventional ultrasound probes and data acquisition paradigms. This review provides a structured overview of pulse-echo SoS estimation methods, categorized by the source of information used, the estimated SoS representation, and the reconstruction strategy. We review methods by their locality, e.g., global, layer-wise, and spatially-resolved predictions, as well as in terms of prediction strategies including gradient-free search, optimization-based solutions, analytical closed-form approximations, and deep learning-based methods. Finally, we summarize emerging diagnostic applications in the breast, liver, and muscle, while discussing challenges and possibilities with SoS imaging.

0.28

Evaluation of effective wave velocities in polycrystalline materials using the ultrasonic reflection matrix

eess.IV physics.app-ph ·2026-09-22 ·Gatien Clément, Alexandre Aubry, Cécile Brütt, Benoît Gérardin, Claire Prada
unusual similarity 0.44
Abstract · 13 pages, 14 figures

In-depth characterization of heterogeneous materials has long been a challenge in non-destructive testing. Here, a method is proposed to determine the elastic constants of metallic polycrystalline materials using back-scattered ultrasound. The waves scattered by the microstructure are analyzed to image the effective bulk velocities. To this end, a reflection matrix is acquired with an array of transducers. The projection of this matrix onto a focused basis is used to estimate an average point spread function. Optimizing this function with respect to the propagation model leads to an estimation of the longitudinal velocity. Additional treatments are developed to adapt the method to map the shear wave velocity. The local Poisson's ratio is then deduced from the ratio between those two velocities. Young's modulus and shear modulus can also be obtained assuming known densities. This matrix approach is experimentally validated on different polycrystalline materials. A sample displaying heterogeneous mechanical properties is then simulated to assess the accuracy and the resolution of the method. Its strengths and limitations are discussed, demonstrating its potential for quantitative non-destructive material characterization.

0.30

UltraPIPS: Improving model perception in B-mode ultrasound with foundation models

cs.CV eess.IV ·2026-08-26 ·Tal Grutman, Tali Ilovitsh
publishedcode/datahot direction similarity 0.44
Abstract · MICCAI ASMUS 2026

In medical imaging, it is common to use learned perceptual image patch similarity (LPIPS) to compare images semantically in feature space. Although backbones pretrained on natural images are widely used for LPIPS computation, B-mode ultrasound images possess distinct speckle patterns and acoustic-specific image statistics that are fundamentally different from natural images and even from other images in radiology. Consequently, we propose that domain-specific models are needed to measure perceptual similarity in ultrasound data, a finding which is not necessarily the case for other imaging modalities. We compare LPIPS metrics across downstream tasks like classification, segmentation and reconstruction using natural image, medical generalist and ultrasound backbone models and show that selection of LPIPS backbone is a non-trivial design choice. In particular, the ultrasound backbone models were more correlated with downstream performance of supervised models than classical and natural image models, and optimization of the LPIPS loss with an ultrasound backbone achieved a strong balance between reconstruction quality and realism. Our code is available at https://github.com/talg2324/UltraPIPS and introduces the UltraPIPS library, a set of LPIPS metrics based on the open-source foundation models analyzed in this paper.

0.51

Meta-clustering of milk mid-infrared spectra identifies dairy cow groups associated with negative energy balance in early lactation

cs.LG ·2026-08-21 ·T. Touil, E. R. Paquet
unusual similarity 0.44
Abstract · 24 pages, 4 figures

Clustering methods have been used to identify distinct groups of milk samples, cows, or herds. Fourier-transform infrared (FTIR) spectroscopy, particularly mid-infrared (MIR) spectroscopy, has been applied to individual cow milk samples to predict various milk traits. Applying clustering directly to MIR spectral data may reveal latent groups of cows associated with milk traits or health disorders and can help prevent these conditions or monitor at-risk animals. This study aimed to identify groups of individual dairy cows in early lactation directly from milk MIR spectra and to analyze their associations with milk traits. Using a dataset of 407,632 individual milk MIR records from 3,408 commercial farms, we combined (i) spectral filtering that selects informative wavenumbers, (ii) two dimensionality-reduction methods: principal component analysis (PCA) and an autoencoder, and (iii) two clustering algorithms: k-means and spectral clustering to yield eight different clustering approaches. We regrouped the assigned clusters into meta-clusters that encompassed the most similar ones identified by the eight approaches. Our results revealed five distinct meta-clusters of early-lactation individual dairy cows significantly associated with milk traits. Despite substantial differences, the eight approaches converged on the same five meta-clusters, and the classic, computationally efficient PCA-based k-means approach using the full spectrum recaptured clusters identified by more sophisticated, computationally intensive approaches. The five meta-clusters were strongly associated with DIM and appeared to reflect a gradient of negative energy balance (NEB) severity: severe, moderate, and possibly mild, while the remaining two likely represented cows recovering from NEB, one with rapid restoration of energy balance and one in early recovery.

0.31

Identifying the Shear Piezoelectric Coefficient using Physics-Informed Neural Networks under Exact Boundary and Initial Constraints

cs.LG physics.comp-phcond-mat.mtrl-sciphysics.app-ph ·2026-11-02 ·Suhas Suresh Bharadwaj
similarity 0.43
Abstract · 19 pages, 9 figures

The shear piezoelectric coefficient $e_{15}$ governs the shear-mode electromechanical coupling in piezoelectric micromachined ultrasonic transducers (PMUTs) and surface acoustic wave (SAW) devices, but measuring it typically requires destructive resonance testing on dedicated specimens. On simulated data, $e_{15}$ can instead be recovered non-destructively from sparse, noisy subsurface wavefield observations using a constrained physics-informed neural network (PINN). By building exact spatial distance functions and temporal multipliers directly into the network output, the clamped, grounded boundaries and resting initial state hold automatically, leaving the loss with only the interior equations of coupled electro-elastodynamics and the data misfit. Non-dimensional scaling brings all governing coefficients within one decade of O(1), and the setup removes the boundary and initial-condition penalty weights that soft-constraint methods must tune. In a six-way comparison (plane-strain PZT-5H, manufactured wavefield, 30 dB noise), a soft-penalty baseline with adaptive weights converges to an erroneous $e_{15}$ in four of the five runs (51.7% mean error), and fixed penalties reach an error of 0.85% only after a second-order optimization stage. The constrained formulations reach mean $e_{15}$ errors between 0.15% and 0.51% with held-out displacement errors below 1%. Within these variants, the spatial multiplier gives rapid first-order convergence, and the quadratic temporal multiplier lowers the early-time electrostatic residual by a factor of 6.8 versus a linear one. On finite-element data along one subsurface line, the full formulation recovers $e_{15}$ with 1.19% mean error at 30 dB and keeps it between 0.65% and 2.71% across a 40 to 0 dB noise sweep. Finally, training on displacements alone still recovers $e_{15}$ with mean errors of 0.45% on finite-element and 1.64% on manufactured data.

0.24

A Controlled Audit of Architectural Complexity in Uncertainty-Aware Multi-Organ Ultrasound Classification

cs.CV ·2026-08-28 ·Yang Song, Pengbo Sun, Shichang Feng, Ye Zhu, Xin Xu +1 more
similarity 0.41
Abstract · Supplementary material is available as an ancillary file on this arXiv page

Multi-organ ultrasound classifiers increasingly combine attention, mixture-of-experts routing, uncertainty gating, and evidential deep learning (EDL) objectives to address heterogeneous anatomy and acquisition. Yet a plausible design rationale does not by itself establish that an added component improves the trained system. We contribute a controlled complexity-audit framework, applied to the deployment decision between the maximal evidential candidate Full-EDL and simpler alternatives. Six candidates were evaluated on the primary dataset and three in an internal replication, using ten matched seeds, frozen image-level partitions, capacity- and optimisation-aware comparisons, symmetric temperature scaling, paired decision rules, and a separate out-of-distribution (OOD) veto. Retaining Full-EDL did not establish a reliable macro-F1 gain on either dataset, while the simplified alternatives remained inconclusive under the non-inferiority margin. Simple cross-entropy with temperature scaling (Simple-CE+TS) met the calibrated negative log-likelihood criterion on both datasets and showed favourable selective-risk ordering. The raw calibration advantage of evidential training disappeared after temperature scaling and did not recur on the second dataset. The gate had negligible observable influence at the audited checkpoints, and deleting the Full-only chain revealed no stable task or calibrated-loss benefit. Simple-CE nevertheless triggered the OOD veto against the fetal probe but not the lung probe, precluding an unconditional OOD-safety claim. We therefore selected Simple-CE+TS for the evaluated in-distribution objective while retaining Full-EDL as the maximal reference. Components should earn retention through functional and retraining-based evidence, and calibration and distribution-shift reliability should be evaluated separately.

0.19