CS Paper Radar

A Transparent 3-DoF Assistive Device for Upper-Limb Tremor and Ataxia Compensation: Design and Experimental Validation

Thomas Dobosz, Veronika Hofmann, Ahmed Barhoma, Ann-Kathrin Henke, Johannes A. Gaus, Hans Mees, Winfried Ilg, Isabell Wochner, Martin Giese, Andreas Bulling, Syn Schmitt, Christophe Maufroy, Urs Schneider, Thomas Bauernhansl, Daniel Haeufle

cs.RO ·submitted 2026-10-22 09:04 UTC · v1

Abstract

Assistive devices for patients with neurodegenerative movement disorders must combine high mechanical transparency with the ability to generate corrective interaction forces. Achieving both properties simultaneously remains challenging. This paper presents the completed iAssistADL platform, a 3-DoF assistive device for future tremor and ataxia compensation during activities of daily living. The system employs a transparency-oriented mechanical architecture with all actuators located at the base, resulting in low moving mass, decoupled kinematics, and high mechanical transparency. To compensate for friction-induced transparency limitations along the vertical axis, a hybrid control strategy is proposed that combines open-loop force rendering in the horizontal plane with closed-loop force control in the vertical direction. The platform is experimentally evaluated through transparency measurements and static and dynamic force-rendering experiments at representative configurations. Results demonstrate resistive torques below 0.1 Nm in the horizontal plane, end-effector forces of up to approximately 10 N throughout the workspace, and accurate horizontal force rendering up to 4 Hz. While the vertical axis remains limited by friction-induced dynamics at higher frequencies, the proposed system successfully combines high transparency with controlled force generation, establishing a promising hardware platform for future tremor and ataxia compensation.

Comment
8 pages, 7 figures, 3 tables, Preprint

Closest papers

Nearest neighbours by meaning across the whole index.

Surgical Master Console Using General-Purpose Robot Arms and a Separable Articulated Distal Interface: Porcine In-Vivo Evaluation

cs.RO ·2026-09-27 ·Minsung Kim, Seonho Shim, Dongho Yee, Younghoon Noh, Juahn Oh +7 more
similarity 0.58
Abstract · Submitted to IEEE ICRA 2027

High-performance surgical master consoles offer intuitive articulated manipulation but are expensive and difficult to reproduce, while accessible commercial haptic devices lack built-in interfaces for surgical wrist articulation and continuous grasp. We present a laparoscopic master in which general-purpose robot manipulators provide the programmable base and surgical-specific interaction is concentrated in a separable distal adapter. Each 6-DoF arm carries a custom 2-DoF direct-drive wrist, continuous grasp sensing, and clutch-based workspace management; the complete bimanual hardware costs approximately US$5,500, below common bimanual commercial haptic references. To support sustained hand-guided use, we characterize current scaling, gravity, and break-away friction and use them for posture-dependent gravity compensation and motion-gated assistance, reducing continuous actuation and thermal loading. A common master state drives either Isaac Sim or an RCM-constrained dual-FR3 platform. Master-state publication to FR3 target update adds at most 8 ms, and tip tracking shows 0.31-0.66 mm mean delay-aligned residuals. In a porcine cholecystectomy experiment, five common operator-side metrics and hand/tip-speed distributions were compared descriptively with human in-vivo telemetry from 120 clinical Versius recordings of 99 cholecystectomy procedures; no interruption originated from the master console, and no abnormal clinical signs were recorded during the 7-day postoperative observation period. These results demonstrate a surgical master built from general-purpose robot arms with surgical-specific interaction concentrated in a separable distal interface.

0.32

Ultra-Low-Impedance Robotic Gripper for High-Bandwidth and Transparent Physical Interaction

cs.RO ·2026-08-10 ·Joon Lee, Ari Choi, Seokhwan Jeong
published similarity 0.58
Abstract · ICRA 2026 (Late Breaking Result Poster)

Conventional robotic grippers often use high-ratio transmissions to generate grasping torque and external force sensors to measure physical interaction. High-ratio transmissions increase friction, reflected inertia, and mechanical impedance, while external sensors add hardware complexity. To address these trade-offs, this study proposes a novel 9-DOF, three-fingered Differential Direct-Drive (DDD) gripper that combines DD motors with a low-ratio (1:2) differential transmission. The mechanism centralizes actuator mass at the base to minimize moving-link inertia, while the differential architecture couples two motors in parallel to amplify torque during flexion. Experiments show that the prototype delivers a nominal grasping force of approximately 18 N and a fingertip force of 4.7 N, while maintaining a low motor contribution to system inertia (0.236%) and low passive mechanical impedance, with a maximum measured value of 50.1 N/m when the motors are unpowered. The proposed hardware addresses the trade-offs among torque, physical transparency, and kinematic dexterity, providing a foundation for high-bandwidth interaction and sensorless proprioceptive force estimation.

0.19

DITTO: Dexterous Interface for Transparent TeleOperation

cs.RO ·2026-09-16 ·Joaquin Palacios, Katelyn Lee, Cheng Zhang, Zhanpeng He, Matei Ciocarlie
similarity 0.58
Abstract · 8 Pages, 6 Figures, 4 Tables

Collecting data for manipulation with high-DOF hands is challenging, as interfaces must capture rich hand motion while rendering the contact interactions essential for precise manipulation. Existing data collection approaches face a trade-off: teleoperation ensures deployment consistency but lacks force feedback, while handheld (in-the-wild) systems provide natural force transparency but introduce a visual embodiment gap at deployment. We present DITTO, a Dexterous Interface for Transparent TeleOperation, which resolves this through the anatomically informed co-design of a dexterous 7-DOF robotic hand and a kinematically equivalent motorized exoskeleton. A 1-to-1 actuator mapping between the exoskeleton and robotic hand enables handheld (in-the-wild) data collection and bilateral teleoperation with joint-level force feedback unified in a single platform. We demonstrate that the DITTO exoskeleton spans the operator's natural index-to-thumb workspace, and showcase DITTO's dexterous capabilities via learned policies on contact-rich tasks.

0.51

Altered Visual Hand Feedback in Virtual Reality: An Exploratory Study in Essential Tremor

cs.HC cs.GR ·2026-10-30 ·Alejandro Pascual-Valdunciel, Marcos Sacristán-Moraleda, Verónica Giménez de Béjar, Julián Benito-León, Juan Marín-Lahoz +2 more
similarity 0.55
Abstract · 12 pages, 5 figures, 3 tables. Under revision

Pathological tremor is the most prevalent movement disorder worldwide, characterized by involuntary muscular oscillations within a frequency of 3 to 12 Hz. Despite extensive research, the underlying mechanisms that generate and modulate tremor are not yet understood, and treatments are usually insufficient. While it is known that visual feedback is an important afferent pathway, little is known about the impact of altering the hand's visual representation on tremor expression. With the development of immersive technologies, VR poses an excellent tool to study how alterations to the representation of the hands affect tremor. In this work, we study this through two complementary experiments. In the first one, we show that a consumer-level hand-tracking system substantially attenuates tremor-band movements without preventing successful task completion. In the second one, with eight patients with essential tremor, we observe task-dependent differences in physical tremor between VR and the real world, with several patients exhibiting lower tremor-band activity in both hand kinematics and muscle oscillations, particularly during reaching tasks. Our findings represent an initial step toward validating the use of VR as an experimental tool for the research and treatment of pathological tremor, while highlighting strong user- and task-dependent effects.

0.19

Now You Feel It, Now You See Me: Digital-Twin-based Teleoperation Interface for Dexterous Manipulation

cs.RO ·2026-10-04 ·Youngchan Shim, Kyutae Lee, JooYun Kim, Jaeseong Hwang, Harim Ji +1 more
similarity 0.53
Abstract · 8 pages, 5 figures, 4 tables

Teleoperation is becoming increasingly important for collecting high-quality demonstrations to teach robots dexterous manipulation skills. For dexterous manipulation, bare-hand tracking provides a practical way to control robotic hands and demonstrate coordinated finger movements without gloves or exoskeletons. However, this type of teleoperation faces two key feedback limitations: a lack of force feedback and visual feedback of occluded region. The absence of force feedback hinders precise and safe manipulation, as operators must infer contact force visually rather than feel them directly. Occlusion by objects or other robot parts impairs the assessment of hand positions, approach distances, and pre-grasp configurations suited to the object's shape. To address these limitations, we propose a digital-twin-based augmented reality (AR) teleoperation interface that integrates bare-hand tracking, bimanual robotic hands, and virtual representations of the robot and task objects. The interface renders tactile measurements on robot hand meshes as visuo-force feedback. Furthermore, it offers a user-controlled virtual view panel or occlusion-aware transparency rendering to provide occlusion-mitigating visual feedback. We evaluated the interface through user studies involving Task 1 and Task 2, examining how force visualization and visual assistance support demonstration collection in tasks requiring careful force regulation and manipulation under occlusion.

0.12

Selfrionette: A Fingertip Force-Input Controller for Continuous Full-Body Avatar Manipulation and Diverse Haptic Interactions

cs.HC ·2026-11-02 ·Takeru Hashimoto, Yutaro Hirao
top venuehighly cited similarity 0.53
Abstract · 14 pages, 12 figures. Author-prepared version of the UIST 2024 paper. Both authors contributed equally

We propose Selfrionette, a controller that uses fingertip force input to drive avatar movements in virtual reality (VR). This system enables users to interact with virtual objects and walk in VR using only fingertip force, overcoming physical and spatial constraints. Additionally, by fixing users' fingers, it provides users with counterforces equivalent to the applied force, allowing for diverse and wide dynamic range haptic feedback by adjusting the relationship between force input and virtual movement. To evaluate the effectiveness of the proposed method, this paper focuses on hand interaction as a first step. In User Study 1, we measured usability and embodiment during reaching tasks under Selfrionette, body tracking, and finger tracking conditions. In User Study 2, we investigated whether users could perceive haptic properties such as weight, friction, and compliance under the same conditions as User Study 1. Selfrionette was found to be comparable to body tracking in realism of haptic interaction, enabling embodied avatar experiences even in limited spatial conditions.

0.61

Elbow Angle Guidance System Based on Surface Haptic Sensations Elicited by Lightweight Wearable Fabric Actuator

cs.HC cs.RO ·2026-08-11 ·Kenta Yokoe, Tadayoshi Aoyama, Yuki Funabora, Masaru Takeuchi, Yasuhisa Hasegawa
published similarity 0.53
Abstract · This is the accepted version of the paper published in Proc. 2024 IEEE International Conference on Advanced Intelligent Mechatronics (AIM), …

The demand for wearable haptic devices has rapidly increased for various applications. However, many haptic devices interfere with the wearer's activities and movements. In addition, several haptic devices fail to elicit intuitive haptic sensations by adjusting to the natural posture of the wearer. To address these issues, we propose an elbow angle guidance system using a lightweight wearable fabric actuator. The proposed actuator is made of fabric and has two McKibben-type artificial muscles attached to it, rendering it extremely lightweight and facilitating the delivery of surface haptic sensations to intuitively induce elbow extension and flexion. The surface haptic sensation elicited by the fabric actuator is adjusted to natural body movements without interfering with the wearer's movements. Moreover, the proposed system measures and guides the elbow angle by changing the intensity of the surface haptic sensation delivered to users in real time. The accuracy of the proposed system is demonstrated through experiments involving human participants.

0.65

Reproducible Vision-Guided 6-DoF Robotic Manipulator with a Mixed Stepper-Driver Architecture and Browser-Native Control

cs.RO cs.CVeess.SY ·2026-08-24 ·Lasan Perera, Deneth Priyadarshana, Dulana Pitiwaduge, Isitha Dinujaya, Mokshan Colambage
code/data similarity 0.52
Abstract · 13 pages, 16 figures, 7 tables. Design files and firmware: https://github.com/Lasan-Perera/6-dof-arm-neuralnexus

We present the NeuralNexus Arm, an open, low-cost 6-DOF robotic manipulator built by an undergraduate engineering team, together with the design decisions and debugging experience needed to reproduce it. The arm is driven by a single STM32H743 microcontroller on a custom printed circuit board (PCB) and combines two stepper-driver strategies on one controller: push-pull 3.3 V step/direction outputs for onboard TMC2209 drivers on the three wrist joints, and open-drain outputs for external CL57T and DM542 drivers on the three high-torque proximal joints. We describe the mechanical design, mixed-driver electronics, interrupt-driven firmware, a MATLAB/Simscape-based inverse-kinematics pipeline, a browser-native control interface using the Web Serial API, and a lightweight vision pipeline for object localisation and autonomous pick-and-place tasks. We also document non-obvious hardware and firmware failure modes encountered during the transition from a development board to the custom PCB as reproducibility guidance. All design files and firmware are released openly. The platform actuates all six axes under coordinated control at a 2 kHz update rate and executes both manual and pre-recorded motions from the browser interface.

0.35