CS Paper Radar

Nodal Inertia Pricing for RoCoF Security with Integration of Synchronous and Virtual Resources

Bomiao Liang, Yu Yang, Licheng Wang, Lei Wan, Dipti Srinivasan, Fushuan Wen, Youbing Zhang, Beiping Hou

eess.SY ·submitted 2026-10-24 10:32 UTC · v1

Abstract

Frequency regulation is becoming a more significant challenge in the undergoing low-carbon transition of modern power systems, which is heavily rely on system inertia provision. In the context of market-based energy allocation, reasonable valuation of the system inertia is crucial to its procurement, namely a worthy price should be determined for inertia providers. However, current research on the value of inertia remains insufficient, particularly during the initial phase immediately following a contingency, a critical period when the system primarily relies on the inherent inertia from conventional units and pre-engaged virtual inertia resources. Furthermore, it is found in existing studies that the Center of Inertia (COI) models exhibit significant deviations from actual physical conditions. For market-oriented reforms that explore individual differences, COI models also fail to capture the heterogeneous contributions of inertia at different nodes to system security. Given these circumstances, this paper proposes a nodal inertia pricing mechanism via a day-ahead unit commitment and inertia co-optimization model with nodal resolution. Following the proposed pricing scheme, the day- or hour-ahead inertia provision is monetized and promoted, providing regional guidance to units and devices with virtual inertia provision, which is further verified by simulation results of the South East Australia Power System.

Closest papers

Nearest neighbours by meaning across the whole index.

Dynamic and Risk-Aware Procurement of Fast Frequency Response from Electric Vehicles and Heat Pumps

eess.SY ·2026-11-18 ·Savvas Panagi, Fanourios Kourougianni, Andreas Olympios, Chrysovalantis Spanias, Petros Aristidou
similarity 0.61
Abstract

Low-inertia power systems increasingly rely on Fast Frequency Response (FFR) to keep the frequency nadir above under-frequency load-shedding thresholds without oversized Frequency Containment Reserve or synchronous inertia. This paper proposes two complementary methodologies that interface with an existing day-ahead FFR capacity market. On the Transmission System Operator (TSO) side, a dynamic procurement rule maps forecasted kinetic energy and contingency magnitude onto an offline neighborhood-need surface, yielding interval-wise FFR capacity requests rather than constant seasonal or annual volumes. On the aggregator side, a risk-aware, TSO-certifiable bidding strategy quantifies reliable FFR capacity from fleets of electric vehicles (EVs) and heat pumps (HPs) by offering lower conditional quantiles of day-ahead headroom at a prescribed delivery reliability. The resulting requests and offers are cleared through a pay-as-bid capacity auction. A Cyprus 2025 case study shows that dynamic neighborhood-based procurement yields an annual clearing cost of about EUR 476,000, which is 30%-33% lower than the seasonal and annual static rules and also below the UFLS VoLL of EUR 637,500 estimated from the fifteen real 2025 events with fmin <= 49 Hz. EV and HP offers meet their target delivery reliabilities, and RMS validation finds 46 of 50 operating points above 49 Hz at both full and 85% FFR delivery.

0.25

On the Achievable Inertia Constant of Inverter Based Resources

eess.SY ·2026-09-28 ·Christos M. Nikolakakos, Hassan Haes Alhelou, Nikos Hatziargyriou
similarity 0.61
Abstract · Under Review in IEEE Transactions on Power Systems

As inverter-based resources (IBRs) displace synchronous generators, the inertia they can actually contribute to the grid becomes a critical planning parameter. Unlike synchronous machines, this contribution is bounded simultaneously by the available energy reserve, the converter power rating combined with voltage ride-through (VRT) obligations, and the inertia-emulation control scheme with its activation delay. This paper derives each bound in closed form and combines them into a unified envelope $\Heff(t,λ,V_g)=\min(\HE,\HP,\HC)$, which uses parameters accessible to the system operator to quantify how much inertia a plant can provide at a given loading $λ$, grid voltage $V_g$, and time $t$ after a disturbance. The analysis shows that below a loading-dependent critical voltage, VRT reactive-current priority does not leave active-current headroom for inertial power injection; that the converter overload ratio $κ$ matters mainly during voltage dips; and that de-loading yields a linear, quantifiable inertia gain, while collocated energy storage (ESS) removes the source-coupling constraint, making grid-following (GFL) and grid-forming (GFM) plants with storage equivalent post-activation, up to the GFL activation-delay discount within short RoCoF measurement windows. Simulations on the IEEE 9-bus system confirm the framework and motivate a two-dimensional inertia capability curve $H(λ,V_{g,\min})$ as a grid-code instrument analogous to the P--Q diagram of synchronous generators.

0.28

Frequency-Security-Aware Real-Time Economic Dispatch with Data Center UPS Flexibility for Inertia and Primary Frequency Response Services

eess.SY ·2026-11-13 ·Shengyi Wang, Liang Du
hot direction similarity 0.60
Abstract

The increasing penetration of renewable energy and the rapid growth of AI data centers are introducing significant challenges to power system frequency security. There is an urgent need to identify grid-compatible resources capable of providing fast frequency support. This paper proposes a frequency-security-aware real-time economic dispatch (RTED) model that enables data center (DC) uninterruptible power supply (UPS) systems to provide steady-state power balancing, inertia response, and primary frequency response (PFR) services. Specifically, tractable analytical frequency-security constraints are derived and incorporated into the RTED framework through second-order cone programming (SOCP) formulation. The proposed model jointly optimizes energy, reserve, and inertia to minimize system operation cost while preventing under-frequency load shedding (UFLS). Numerical validation on a modified IEEE 39-bus system demonstrates that the proposed RTED model with UPS flexibility can economically support system operation and significantly improve frequency security under active-power deficit disturbances.

0.30

A Power-Trajectory Framework for Data Center Participation in Day-Ahead Markets

eess.SY ·2026-10-12 ·Menghan Zhang, Caisheng Wang
similarity 0.57
Abstract · 10 Pages, 7 Figures, 4 Tables

The rapid expansion of artificial intelligence (AI) is driving substantial growth in data center electricity demand. Interval-based energy blocks in day-ahead markets do not explicitly retain predictable intra-interval demand evolution, potentially creating mismatches with ramp-feasible generation trajectories and affecting settlement. This paper proposes a power-trajectory framework in which data centers declare predictable aggregate demand evolution through continuous demand-side power trajectories before market clearing. The declared trajectories are treated as exogenous inputs for constructing generation trajectories and the corresponding price trajectory. For feasible market-clearing outcomes, physical temporal consistency is established through continuous-time power balance and satisfaction of the modeled generation operating constraints, while economic temporal consistency is established by preserving the dispatch-price correspondence in energy settlement on a common temporal basis. Under the adopted settlement definitions, a trajectory-based settlement analysis separately quantifies the monetary magnitude of representation-induced power imbalances and the supply-side compensation that may remain under temporally consistent clearing and settlement. An illustrative 5-bus case demonstrates the elimination of representation-induced power imbalance and identifies the timing and physical sources of supply-side compensation. A modified IEEE RTS-GMLC case further illustrates these compensation effects across multiple generating units under workload-driven data center demand variations.

0.17

A Primal-Dual Formulation for Pricing Static Voltage Stability Services within a Unit Commitment Model

eess.SY ·2026-09-10 ·Peng Wang, Luis Badesa
similarity 0.56
Abstract

In modern power systems with high penetration of Inverter-Based Resources (IBR), most converters operate in Grid-Following (GFL) mode. Some buses exhibit inherently low Short-Circuit Ratios (SCRs), a property majorly shaped by network topology. The integration of GFL-IBR onto such weak buses thus demands attention to static voltage stability. To address this issue, market mechanisms have been proposed to incentivize generators to provide voltage stability services, such as commitment of synchronous generators for reducing the equivalent impedance at low SCR buses and adaptive reactive power support from GFL-IBR. To compute shadow prices for these services, previously proposed methods such as the `restricted' and `dispatchable' approaches may fail to guarantee operating cost recovery for voltage-stability service providers. As the resulting prices are determined purely from a social surplus maximization objective, the profitability of units is entirely overlooked. This suggests that new pricing methodologies are needed to satisfy cost-recovery requirements. Therefore, this paper proposes a pricing method based on a primal-dual formulation. Case studies demonstrate that the proposed method can consistently produce revenue-adequate shadow prices, enabling all participating units to recover their costs without supplementary uplift payments.

0.17

Shadow Pricing in Transient Stability-Constrained Optimal Power Flow

eess.SY ·2026-10-13 ·Alex Coelho, Araceli Hernandez, Luis Badesa
similarity 0.56
Abstract · 10 pages

Transient stability constraints alter the economic dispatch of power systems, while the resulting price signals and their implications for market settlement remain insufficiently characterized. Existing approaches identify stability-related components in locational marginal prices, without deriving shadow prices for individual assets, such as generators and loads, or analyzing the resulting settlement. To address this gap, this paper derives shadow prices from a transient stability-constrained optimal power flow in which the differential-algebraic equations governing the system dynamics are embedded through direct discretization. Each shadow price decomposes into a nodal energy component and a stability component, the latter formed by the dual variables of the dynamic equations in which the power of the asset appears. Shadow prices are therefore asset-specific: co-located generators and loads are assigned the same nodal energy component, but can be subject to different stability components when their transient behaviors differ. Case studies on the WECC 9-bus system and a modified IEEE 39-bus system show that settlement at the proposed shadow prices allocates the cost of the stability constraints among the assets without any side payment. An asset that reduces the stability margin is charged its stability component, whereas an asset that improves it is paid, and no generator is dispatched at a loss.

0.29

Impact of Security Modeling Fidelity on Hyperscale Data Center Hosting Capacity Assessment

eess.SY ·2026-10-13 ·Haoxiang Wan, Linhan Fang, Jonghwan Kwon, Jesus Silva-Rodriguez, Jianyi Yang +3 more
published similarity 0.53
Abstract · 5 pages, 2 figures, 1 table. Accepted to the 2027 IEEE PES Grid Edge Technologies Conference & Exposition

This paper assesses hyperscale data center hosting capacity in transmission grids. Hosting capacity (HC) analysis quantifies the maximum additional load a bus can accommodate without violating operational constraints. This paper defines data center HC as the maximum time-invariant active power demand at a single target bus over a 24-hour peak-day horizon, and evaluates it under four models of increasing fidelity (i.e., the extent to which the model enforces real-world operational security requirements) on the modified IEEE 24-bus system: (i) DC optimal power flow (DC-OPF) without unit commitment (UC), (ii) basic SCUC (security-constrained unit commitment) without reliability constraints, (iii) SCUC with spinning reserve, and (iv) N-SCUC with both reserve and branch-contingency security. Comparing these models quantifies the impact of unit commitment, reserve requirements, and N-1 security on bus-level HC estimates. The N-SCUC yields an average HC of 444 MW; omitting N-1 security raises this to 532 MW, a 19.8% overestimation. The DC-OPF and basic SCUC models further overestimate HC, indicating a trade-off between model complexity and estimation accuracy.

0.60

Approximating Energy-Regulation Feasible Region of Virtual Power Plants: A Data-driven Inverse Optimization Approach

eess.SY math.OC ·2026-08-26 ·Ruike Lyu, Hongye Guo, Qixin Chen
publishedhighly cited similarity 0.53
Abstract · Published in: 2024 IEEE Power & Energy Society General Meeting (PESGM)

System operators will probably allow virtual power plants (VPPs) to submit their feasible region (FR) for market clearing and dispatch. A VPP needs to determine its FR to submit as a whole based on the individual operation model of its internal distributed energy resources (DERs), which is an FR aggregation problem. Existing FR aggregation approaches rely on analytical methods, which have issues with generality and adaptability. In this paper, we propose a data-driven approach to approximate the energy-regulation FR of VPPs. It adopts the virtual battery model to approximate the aggregate FR of a VPP and determines the model parameters through inverse optimization based on generated multi-scenario operation data using the original operation model. Numerical tests verified the accuracy of the proposed method. We believe that our work helps to better leverage the flexibility of DERs.

0.63