pCoRev: Physics-Informed Contrastive Learning for Unsupervised Reverberation Artifact Suppression in Ultrafast Plane-Wave Imaging

Hyunwoo Cho, Yeeun Kwon, Yangmo Yoo, Jinbum Kang

eess.SP ·submitted 2026-10-28 09:35 UTC · v1

Abstract

Reverberation artifact suppression in ultrafast plane-wave (PW) imaging remains challenging because artifact-free reference data are generally unavailable and multipath echoes often resemble tissue signals. Coherent plane-wave compounding (CPWC) attenuates reverberation only partially and sacrifices the frame rate that motivates PW imaging. We propose pCoRev, an unsupervised physics-informed contrastive learning framework that leverages the distinct angular coherence characteristics of tissue echoes and reverberation artifacts. A single-angle I/Q frame is the network input, and the remaining angles of the same CPWC acquisition provide angle-consistent positive pairs, residual-derived negative pairs, and coherence-guided self-supervision, so no paired artifact-free data are required. On a fabricated reverberation phantom with 31 validation acquisitions, pCoRev achieved the best contrast ratio (CR), contrast-to-noise ratio (CNR), and generalized CNR (gCNR) of 38.76 +/- 5.40 dB, 11.75 +/- 1.81 dB, and 0.932 +/- 0.051 against delay-and-sum (DAS), delay-multiply-and-sum, a supervised 3D convolutional neural network, and unsupervised deep coherence learning. Because the network is trained on single-angle inputs, it also operates on a single PW transmission: with one angle, pCoRev reached a CR of 32.10 +/- 7.79 dB and a CNR of 10.39 +/- 3.02 dB, exceeding 75-angle compounded DAS (20.45 +/- 3.84 dB and 8.38 +/- 2.00 dB) with 75-fold fewer transmissions. On four clinical acquisitions from other scanners, pCoRev improved CR over DAS by 9 to 21 dB without fine-tuning. These results indicate that physics-informed unsupervised contrastive learning suppresses reverberation effectively while preserving the frame-rate advantage of ultrafast PW imaging.

Closest papers

Nearest neighbours by meaning across the whole index.

Dual-Domain Sparse-View 4D CBCT Reconstruction with Spatial-Temporal Consistency Learning

cs.CV ·2026-10-13 ·Qi Lai, YuTong He
similarity 0.58
Abstract

Four-dimensional cone-beam computed tomography (4D CBCT) provides phase-resolved volumetric images for image-guided radiotherapy. Yet good reconstruction quality usually needs many projections. This increases scan time and radiation dose. We propose STCNet, a sparse-view 4D CBCT reconstruction framework that uses spatial-temporal consistency learning. STCNet reconstructs high-quality images from only 16 projections in each respiratory phase. STCNet integrates physics-driven positional encoding to enforce geometric consistency in the projection domain and introduces temporal encoding in latent space to capture respiratory motion dynamics across phases to capture dynamic respiratory motion across phases. A dual-domain collaborative strategy jointly optimizes both projection and image domains, enhancing structural fidelity and temporal coherence. We tested STCNet on the TCIA-LUNG dataset and a CIRS thorax phantom dataset. STCNet performed better than conventional methods and recent deep learning baselines in image quality, artifact reduction, and structural preservation. On TCIA-LUNG, STCNet reached PSNR values of 33.311, 32.695, and 32.658 dB at phases 2, 5, and 8. The corresponding SSIM values were 0.845, 0.823, and 0.825. On CIRS, STCNet achieved PSNR values up to 36.497 dB and SSIM values up to 0.877. These results support STCNet as a promising framework for low-dose, phase-resolved 4D CBCT reconstruction in image-guided radiotherapy.

0.12

Physics-Grounded Objective-Conditioned Deep Beamforming for Adaptive Resolution-Contrast Control in Plane-Wave Ultrasound Imaging

eess.SP ·2026-10-05 ·Gopika Gopikrishnan, Mahesh Raveendranatha Panicker
similarity 0.58
Abstract

Plane-wave ultrasound enables ultrafast imaging but remains constrained by a receive-aperture-dependent resolution- contrast trade-off. Fine structures benefit from high spatial resolution, whereas diffuse tissue and lesions often require improved contrast and clutter suppression. These objectives favor different receive-aperture configurations, yet conventional beamformers operate at a fixed imaging point. We propose a physics-grounded, objective-conditioned deep beamformer that enables controllable image formation within a single network. From single-plane-wave channel data, the network predicts spatially varying receive-apodization weights, conditioned on the desired imaging objective through feature-wise linear modulation. The conditioning variable is explicitly tied to a physically defined receive-aperture configuration and supervised using the correspondingcoherent-plane-wave-compounding target. Differentiable, region-of-interest-aware, physics-guided quality losses further promote objective-specific resolution and contrast during end-to-end training. The model is trained exclusively on simulated channel data spanning diverse target morphologies and echogenicities, and evaluated zero-shot on the PICMUS and CUBDL datasets, including unseen probe geometries. The proposed framework generally improves upon single-plane-wave delay-and-sum reconstruction while providing objective-dependent control. On PICMUS, the proposed method improves gCNR by up to 16.8% and axial resolution by 22% compared with the reference beamforming method. Moreover, switching between the contrast- and resolution-oriented objectives enables controllable changes of up to 4.9% in lesion contrast and 11.4% in lateral resolution. Compared with the best-performing learning-based baselines, the proposed method reduces lateral full-width-at-half-maximum by 5.9% and improves generalized contrast-to-noise ratio by 6.6%.

0.29

Motion Artifact-Aware Self-Supervised Representation Learning for 3D Brain MRI Motion Artifact Reduction

cs.CV physics.med-ph ·2026-08-10 ·Mojtaba Safari, Shansong Wang, Zach Eidex, Matthew Goette, Tonghe Wang +2 more
top venue similarity 0.55
Abstract

Patient motion remains a source of image degradation in brain MRI, leading to signal loss, blurring, and geometric distortion that compromise quantitative analysis. Existing deep learning methods for motion correction typically rely on paired clean-corrupted data or k-space acquisitions, which are rarely available in clinical settings. We propose SSRL-MAR, a motion artifact-aware unpaired representation learning framework for motion artifact reduction that requires neither paired training data nor explicit motion labels. SSRL-MAR employed a three-stage training strategy: (1) contrastive learning on 3D patches to extract motion representations by contrasting clean and synthetically corrupted images, (2) a motion artifact-aware synthesis network to generate motion artifacts from clean scans, and (3) a motion artifact-aware generator to restore clean volumes using the learned degrader for self-supervised supervision. On in-silico dataset, SSRL-MAR achieved PSNR 23.81dB, SSIM 91.55%, and NMSE 0.79%. On in-vivo MR-ART dataset, the pretrained model reduced motion distortion, and unsupervised domain adaptation further improved anatomical fidelity. Against a source-only supervised model trained on the same simulated pairs, SSRL-MAR improved PSNR by up to 2.0 dB on MR-ART after unsupervised domain adaptation, and remained within 0.25-0.47 dB of an oracle supervised model that requires real paired data unavailable in practice. At the milder motion level, volumetric error in structures such as the corpus callosum and ventricular system decreased by more than 50%, confirming improved neuroanatomical consistency. These results indicate that SSRL-MAR provides a robust and scalable image-domain solution for 3D brain MRI motion correction, enabling reliable structural quantification in large-scale neuroimaging studies without requiring prospectively acquired pairs or acquisition-specific calibration.

0.29

Uncovering the Invisible in Routine Radiology: Cross-Modal Detection of MRI-Verified Soft-Tissue Pathologies from CBCT via Physics-Guided 3D Self-Supervised Learning

eess.IV cs.CVcs.LG ·2026-11-17 ·Evgeny Alves Limarenko
similarity 0.54
Abstract

Routine X-ray modalities like cone-beam computed tomography (CBCT) are optimized for high-contrast mineralized tissues, leaving soft-tissue abnormalities buried beneath photon noise and below human visual perception. Thus, detecting non-calcified pathologies requires secondary magnetic resonance imaging (MRI). We demonstrate that sub-visual radiographic signatures of soft-tissue pathology are physically preserved within routine CBCT scans and can be extracted for opportunistic screening using a targeted, physics-guided deep learning pipeline, even under extreme paired-data scarcity. Using the temporomandibular joint (TMJ) as a model system (N = 212 paired CBCT-MRI joints), we address the severe overfitting of high-capacity 3D networks through a two-stage framework. First, we employ a frozen full-grid 3D masked autoencoder (BertsWin) pre-trained on 6,550 unlabeled CBCT volumes via the GradientConductor (GCond) optimizer and an anatomy-aware objective (PhysLoss) redirecting gradient flow into the [-300, 300] HU soft-tissue window. Second, automated localization of the condylar zenith drives a deterministic 3D cropping that eliminates 81% of background osseous variance. Evaluated via a patient-isolated 3x10-fold stratified cross-validation protocol, a statistically robust sub-visual signal for MRI-verified synovial effusion (ROC AUC = 0.793) emerges exclusively from representations pre-trained with the PhysLoss and GCond regime. Crucially, only this setup captures true 3D anatomical chirality (p < 0.001) and high intra-patient structural consistency (0.791) over inter-patient noise; conversely, identical architectures pre-trained with standard L2 loss or unmasked variance decomposition (MVC) collapse to random guessing. These findings establish a generalizable paradigm for repurposing routine, low-contrast radiographic scans into opportunistic screening tools for occult soft-tissue disease.

0.15

Open-H-RF: A Large-Scale Ultrasound Raw Channel Dataset Initiative

eess.SP ·2026-10-09 ·T. S. W. Stevens, S. W. Penninga, W. L. van Nierop, O. Nolan, F. Duelmer +181 more
dataset similarity 0.54
Abstract · Preprint: 15 pages, 15 figures, 3 tables. Dataset (v1.0): https://open-h.github.io/Open-H-RF

Medical ultrasound is a widely accessible, real-time imaging modality, yet progress in data-driven ultrasound research is constrained by the scarcity of large, open collections of raw channel data. Existing public datasets are predominantly based on reconstructed images, while the smaller number of open raw channel datasets is generally specialized to individual reconstruction or imaging tasks, limiting the development of general-purpose methods and foundation models that operate directly on ultrasound signals. While interpretive tasks can be performed on reconstructed images, many of the key technical challenges in ultrasound imaging, such as aberration correction and reverberation reduction, require the raw channel data itself. We introduce Open-H-RF, a community-driven open dataset initiative comprising approximately 40 TB of medical ultrasound raw channel data in 19,332 acquisitions, contributed by 38 institutions across academia and industry, spanning in-vivo, phantom, and simulated data. Each dataset is annotated with a number of supported tasks, ranging from generalized reconstruction, speed-of-sound estimation, and aberration correction to blood flow imaging, motion estimation, quantitative ultrasound, and image interpretation. Open-H-RF provides a unified, self-contained data format that captures raw channel data together with the acquisition, probe, metadata, and reconstruction information required for reproducible processing across scanners and acquisition schemes. The corpus is publicly hosted under a permissive CC BY 4.0 license and can be streamed programmatically and selectively at scale. By bringing heterogeneous ultrasound data into a common representation, backed by modern data infrastructure, Open-H-RF lowers the barrier to working with raw channel data and aims to open medical ultrasound research to new communities. See https://open-h.github.io/Open-H-RF.

0.47

Multi-Stage Phase-Aware Self-Supervised Reconstruction for Multi-Echo Gradient-Echo MRI

cs.AI ·2026-11-09 ·Juan Liu, Nian Wang
similarity 0.54
Abstract · Submit to a journal; under review

Purpose: To develop a phase-aware self-supervised framework for accelerated high-resolution multi-echo gradient-echo (mGRE) MRI that preserves anatomical detail and complex echo information for quantitative mapping. Methods: We developed multi-stage phase-aware self-supervised reconstruction (MSPR-GRE), integrating progressive k-space expansion with phase estimation and refinement. Sequential unrolled networks reconstruct complex multi-echo images and update echo-dependent phase priors. A relaxation-informed temporal subspace is used for acquisitions with at least four echoes, while shorter echo trains are reconstructed in the image domain. Training uses held-out acquired k-space samples without fully sampled targets. Evaluation included 9.4 T ex vivo mouse-brain data 30um eight-echo and 18um dual-echo) and retrospectively undersampled 7 T AHEAD human-brain data, with supervised ablations. Results:MSPR-GRE reduced artifacts in regions of rapid phase variation and preserved fine mouse-brain anatomy. Across five AHEAD test datasets at R = 4, 8, and 12, it generally improved magnitude-image, T2* map, and QSM metrics, particularly at higher acceleration. At R = 12, fourth-echo magnitude NRMSE was 12.09$\pm$0.60% versus 21.55$\pm$1.12% for SSDU. Ablations indicated benefits of phase refinement, while supervised experiments supported multi-stage phase-aware reconstruction. Conclusion: MSPR-GRE improves accelerated mGRE reconstruction and quantitative-map agreement without fully sampled training targets. Further validation of generalizability and phase-estimation accuracy is needed.

0.17

EchoDiST: Self-distillation-based joint learning for diffusion-conditioned echocardiographic myocardial motion estimation

cs.CV ·2026-10-08 ·Feiyue Qi, Xingyue Wei, Jianwen Luo
similarity 0.54
Abstract · 19 pages, 14 figures

Motion estimation in echocardiography is essential for quantitative assessment of cardiac function and myocardial mechanics, but remains challenging due to image artifacts, limited image information, speckle decorrelation, and the scarcity of ground-truth displacement fields. Anatomy-guided approaches can provide structural information, yet often rely on expert-labeled myocardial segmentations. We propose EchoDiST, a framework for unsupervised echocardiographic myocardial motion estimation that integrates self-distillation-based joint learning with a diffusion-conditioned motion estimation network. Here, unsupervised motion estimation refers to learning without ground-truth displacement fields. The self-distillation strategy jointly optimizes anatomical segmentation and myocardial motion estimation under limited anatomical annotations. Diffusion-based conditioning is used during training with stochastic perturbations, while inference requires only a single deterministic forward pass without iterative reverse-diffusion sampling. EchoDiST was evaluated on three echocardiographic datasets, including two external test datasets under cross-view and cross-dataset settings. Compared with seven representative learning-based methods, EchoDiST consistently improved anatomical alignment, myocardial strain assessment, and motion-derived functional and cardiac-phase assessment. These gains were statistically significant across the evaluated tasks and datasets. Overall, EchoDiST provides an effective approach for reliable myocardial motion estimation under limited anatomical supervision and supports downstream quantitative assessment of cardiac function.

0.21

Multi-Pass, Multi-View Blended Learning for High-Fidelity Volumetric CT Synthesis from Chest X-Rays

cs.LG ·2026-09-09 ·Ozer Can Devecioglu, Serkan Kiranyaz, Rashid Mazhar, Tahir Hamid, Muhammad Chowdhury +1 more
code/data similarity 0.53
Abstract · 13 pages, 11 figures

Reconstructing volumetric Computed Tomography (CT) from a single 2D chest radiograph (CXR) is an ill-posed inverse problem, further complicated by the scarcity of paired CXR-CT training data. Prior approaches address this by training on Digitally Reconstructed Radiographs (DRRs), which are synthetic projections derived from CT volumes. However, the domain gap between DRRs and real CXRs limits generalization, often resulting in coarse or anatomically inconsistent reconstructions when applied to clinical images. To address this challenging problem, this study introduces a Multi-Pass Multi-View Blended Learning framework for synthesizing high-fidelity volumetric CT directly from real chest X-ray (CXR) images. The proposed approach progressively decomposes the synthesis task into two distinct, complementary learning stages. Stage 1 is an unsupervised CXR-to-DRR Domain Adaptation, while Stage 2 includes three passes, namely, (a) supervised DRR-to-CT Transformation, (b) unsupervised Multi-View Slice Refinement, followed by (c) Progressive Transfer Learning (PTL). With such a blended learning paradigm, the proposed approach mitigates the synthetic-to-real domain gap while enhancing both the structural integrity and anatomical detail of the final output. On the LIDC-IDRI dataset, where paired DRR-CT ground truth is available for quantitative evaluation, the proposed method improves upon prior methods by up to 14% in PSNR and 7.6% in SSIM. The framework successfully generates structurally consistent and anatomically realistic high-fidelity CT volumes from real CXRs, marking a significant advancement toward clinical viability of CT reconstruction from standard radiographic images.

0.36