CS Paper Radar

Safety Verification for Voltage Control in Inverter Dominated Radial Distribution Networks under Actuator and Sensor Adversarial Attacks

Georgios Pantazis, Revi Boelen, Michelle S. Chong

eess.SY math.OC ·submitted 2026-10-30 15:45 UTC · v1
benchmark

Abstract

This paper develops a safety verification framework for inverter-based radial distribution networks under sensor and actuator attacks. Each customer is equipped with a droop-based controller to regulate its voltage within a desirable bound of a reference, i.e., to achieve safety. In our setting, attacks and disturbances enter the droop-based controllers, while actuator attacks corrupt the reactive power injected into the network. Consequently, invariance of the controller state alone does not guarantee compliance with inverter capacities or customer voltage limits. To address this challenge, we derive conditions to guarantee that the reactive power state remains inside a predefined ellipsoid, while at the same time ensuring that the attacked reactive power injections and customer voltages respect predetermined operating limits that hold uniformly for the entire predefined ellipsoid. Together, these conditions guarantee safety under all admissible disturbances and state-dependent sensor and actuator attacks. Finally, we express the resulting containment condition as a linear matrix inequality (LMI) feasibility problem. A five-customer radial network based on the CIGRE benchmark corroborates our theoretical developments in simulations.

Closest papers

Nearest neighbours by meaning across the whole index.

Certificate-based Synthesis of Coordinated Droop Control for Heterogeneous Radial Distribution Networks

eess.SY math.OC ·2026-08-11 ·Georgios Pantazis, Michelle Chong
similarity 0.62
Abstract

Voltage certificates for droop-controlled radial distribution networks are often constructed from worst-case quantities. In heterogeneous radial networks, this approach can hide where voltage deviations are most likely. Furthermore, such certificates become increasingly conservative as the network sensitivities accumulate. Leveraging the structure of the linearized DistFlow model and slope-restricted droop controllers, we derive tighter deterministic voltage certificates that retain heterogeneous network, disturbance and inverter characteristics of each bus. The certificates reveal the buses and local limitations that dominate certified voltage performance. Worst-case bounds are recovered as a special case. Although tighter, the heterogeneous certificates can still deteriorate downstream due to the network structure. To address this, we leverage our certificates as design variables for coordinated voltage control. Specifically, we develop a virtual droop architecture with coordination and affine feedforward compensation to reshape the effective voltage sensitivity, and formulate a linear program that jointly synthesizes the controller and minimizes its heterogeneous voltage certificates under operational, communication and inverter placement constraints. The resulting controller guarantees the voltage and inverter bounds for all admissible disturbances. Evaluation on two network benchmarks, a five-customer residential feeder and a 26-customer rural network comprising four feeders, demonstrates improved certificates and voltage behaviour under inverter limits.

0.34

Fixed-Time Voltage Regulation in Distribution Networks with Impedance Awareness

eess.SY ·2026-10-01 ·Nilanjan Roy Chowdhury, Venkatesh Sarangan
similarity 0.59
Abstract · 8 pages, 6 figures

This letter introduces an optimization-based fixed time control algorithm for solving the voltage regulation problem of a radial and balanced power distribution network. The proposed algorithm requires no prior knowledge of the exact network impedance (resistance and reactance), yet guarantees voltage convergence to the predefined safe limit within a fixed time-window. We embrace results from Fixed-time stability (FxTs) and Control Lyapunov function (CLF) to analyze the stability and robustness of the underlying algorithm and then synthesize it leveraging the Quadratic Programming (QP) approach. We first analytically provide sufficient conditions on the control gains and the design parameters, that can ensure voltage regulation in fixed-time. Thereafter we transform the existing voltage regulation problem into an equivalent QP-based optimization framework and translate the aforesaid conditions to find feasible solutions for voltage stability. We empirically verify the efficacy of our proposed algorithm on the IEEE-33 bus distribution network and compare its performance against other existing robust control methods.

0.29

Robustness of Local Energy Markets to Cyberattacks: Case Study of False Data Injection

cs.CR ·2026-09-29 ·Mehran Moradi, Reza Zamani, Phil Aupke, Andreas Theocharis, Andreas Kassler
similarity 0.57
Abstract

Market clearing in community-based local energy markets relies on power demand and PV forecasts, making it vulnerable to coordinated false data injection (FDI) attacks. This paper proposes a bilevel optimization framework to identify worst-case bus-level FDI against interconnected multi-community electricity markets within a distribution network. The upper level attacker maximizes physical impact, measured by cumulative voltage deviation, while accounting for detectability. The lower level re-clears the interconnected multi-community markets subject to operational and network constraints. The bilevel model is reformulated as a single-level mixed-integer program through Karush-Kuhn-Tucker conditions and solved using the epsilon constraint method to characterize the trade-off between physical impact and detectability. Case studies on the IEEE 33-bus system with three communities show that even bounded, system-level zero-sum attacks can reshape local trading, reduce voltage security margins, and produce asymmetric community-level market outcomes. The results further show that vulnerability depends strongly on the spatiotemporal placement of falsified data rather than on uniform spreading across buses and time periods.

0.26

AIDC Microgrid Vulnerability Assessment Under Computing-Power Coordinated Attacks

eess.SY ·2026-08-11 ·Ze Yu, Hongwei Zhen, Chao Shen, Mingyang Sun
similarity 0.56
Abstract

The rapid growth of large language model (LLM) services is expanding AI data centers (AIDCs), increasing electricity demand and associated carbon emissions. Renewable energy integration can mitigate these impacts but also strengthens the coupling between AIDC loads and inverter-interfaced generation, creating cross-domain cyber-physical vulnerabilities. Specifically, adversarial AI requests alter AIDC power demand, whereas inverter control tampering modifies source-side dynamics, and their combined impact on system stability varies with generation forecast and demand response uncertainties. To this end, we propose an uncertainty-aware AIDC microgrid vulnerability assessment framework under computing-power coordinated attacks. First, the framework maps adversarial AI requests to AIDC power variations and represents uncertainties in attack-induced demand responses and photovoltaic (PV) forecasts through confidence-weighted realizations. Then, impedance based stability analysis combines these realizations with bounded inverter parameter tampering to construct attack reachable domains and identify critical attack time windows. Furthermore, a separate criterion identifies fixed coordinated attack vectors that retain destabilizing capability throughout each selected window. Case studies demonstrate that, unlike either attack component applied alone, coordinated attacks within identified critical windows induce sustained inverter frequency oscillations with peak absolute deviations exceeding 20% of nominal frequency, whereas the evaluated out-of-window response remains bounded. The proposed method further identifies critical attack windows and the associated coordinated attack vectors.

0.04

Controller- and Communication-Aware Flexibility Margins for Electric Distribution Networks

eess.SY ·2026-10-14 ·Saif R. Kazi, Kaarthik Sundar
similarity 0.56
Abstract · 11 pages

This paper develops a framework for quantifying operational flexibility in radial electric distribution systems under coupled active- and reactive-load uncertainty. Flexibility is defined as the largest scaling of a prescribed uncertainty set that can be accommodated while satisfying network and actuator limits under a given control architecture. We consider a one-sided Euclidean set for robust demand-growth capability, with a direct extension to bidirectional variations. Under LinDistFlow, controllable distributed resources and feeder-head exchange with the upstream grid jointly balance active-power disturbances, while local Volt/VAR feedback regulates reactive power. The resulting affine closed-loop disturbance response admits exact second-order-cone robust counterparts. For fixed Volt/VAR gains, a convex reformulation jointly optimizes the flexibility margin and active-power participation factors, including feeder-head participation. A sparse load-to-generator feedforward map further captures communication constraints. Numerical studies on the Iowa-240 feeder demonstrate how the amount of control authority and communication structure shape the achievable flexibility margin.

0.24

Adversarially-Informed Node Criticality Identification in Power Grid Measurements

eess.SY math.OC ·2026-08-27 ·Koto Omiloli, Olugbenga Moses Anubi
similarity 0.55
Abstract

Power grid state estimation relies on sensor measurements that are increasingly vulnerable to adversarial corruption in cyberphysical environments, potentially leading to significant deviations in system observations. This motivates the need to identify critical measurement nodes whose compromise results in the most severe system-level impact. However, existing node criticality methods primarily rely on structural or steady-state analyses and do not explicitly account for adversarial effects on system behavior. To address this gap, this paper proposes an adversarially informed framework for identifying critical measurement nodes in linearized power systems. Within this framework, a structured attack generation mechanism is developed to construct stealthy and effective false data injection attacks (FDIAs) against an H-infinity resilient state estimator. Node criticality is then evaluated using coalition-based marginal contributions of compromised sensor subsets, estimated via permutation sampling over a prescribed set of admissible nodes, with the resulting importance scores mapped to the corresponding physical buses. Simulation results on the IEEE 14-bus system show that adversarially identified nodes induce larger deviations in frequency, voltage angle, and net power compared to randomly selected nodes, demonstrating the effectiveness of the proposed framework.

0.23

System-Level Factors Influencing AGC Cyber-Attack Success and RAS Vulnerability in Multi-Area Grids

eess.SY ·2026-10-30 ·Abdulmannan Ajabnoor, Zhi Jin Zhang, Maryam Saeedifard, Dominic Groß
published similarity 0.54
Abstract

Automatic generation control (AGC) stabilizes frequency and scheduled power exchanges among interconnected areas, yet its reliance on communication networks introduces cyber-vulnerabilities. This work examines coordinated AGC cyber-attacks in the presence of remedial action schemes (RAS) and identifies operating conditions under which an attacker can drive grid frequency beyond safe limits while evading RAS. A feedback-based attack policy is used to manipulate AGC signals and steer system frequency toward unsafe trajectories. Then, a large nested-loop parametric sweep---spanning attacked-area inertia relative to its interconnected neighboring area, AGC capacity versus maximum tie-line transfer, AGC update rate, load damping, and bi-directional power transfers---generates over 1.45 million scenarios. These are classified using a decision tree to establish guidelines to distinguish successful from unsuccessful attacks based on frequency deviations. The resulting vulnerability guidelines are validated on a three-area system using phasor-domain simulations with IEEE 9-bus area models, detailed turbine--governor dynamics, and under/over-frequency load and generation shedding. Results show that specific combinations of AGC capacity, inertia distribution, and pre-attack tie-line loading increase the likelihood of successful attacks, offering operators actionable criteria for identifying vulnerable operating conditions.

0.41

Optimal Measurement Selection for Certifiable Voltage Monitoring in Power Distribution Systems

eess.SY ·2026-09-23 ·Peng Zhang, Line Roald, Manish K. Singh
similarity 0.54
Abstract · 10 pages, 4 figures, submitted to HICSS'60

Maintaining consumer-end voltages within mandated limits is a central task in operating power distribution systems. Rising penetration of distributed generation, electric vehicles, and flexible loads complicates this task, while a scarcity of real-time measurements leaves distribution networks largely unobservable. Operators commonly monitor a few bellwether meters, which indicate operational health but certify nothing about the unmeasured buses. This work asks how to select measurements that are reported in real time and can certify network-wide voltage-limit compliance. We first illustrate the geometry of the measurement values that certify voltage safety at unmeasured nodes. Building on this geometry, we formulate a bilevel optimization that selects measurements to maximize certification capability, introducing a novel safety-violation metric with favorable monotonicity properties. We derive a strong-duality-based single-level reformulation and two scenario-reduction schemes with quantifiable suboptimality. Numerical tests on the SCE 56-bus system corroborate the superior certification capability and computational efficiency of the proposed approach.

0.27