CS Paper Radar

Winding the Field, Not the Wire: Overlaying Magnetics to Improve Current Dynamics in Modular Power Electronics

Jinshui Zhang, Boshuo Wang, Hunter Cullina, Emmy Nelson Madore, Maya Clinton, Angel V Peterchev, Stefan M Goetz

eess.SY ·submitted 2026-11-02 05:08 UTC · v1
unusual

Abstract

Modular power electronics scale power capacity by distributing it across cascaded modules. State-of-the-art modular multilevel converters further introduce dynamic inter-module switched-capacitor exchange and balancing through parallelization. In larger converters, however, this mode needs inter-module inductance to control the equilibration currents. Specifically, differential-mode inductance limits these currents, but existing solutions require conductor re-routing and introduce parasitic resistance. This work presents a non-intrusive resistance-free differential-mode inductance solution: a figure-of-eight-shaped magnetic core that guides the magnetic flux path around existing conductors, such as high-current bus bars. This design adds differential-mode inductance without modifying the conductors. We fabricated a core that provides a 1.52 uH differential-mode inductance while suppressing the common-mode inductance to only 7% of the DM inductance. The core reduces the inter-module current surge from 20.46 A to 7.76 A. The original conductors remain intact.

Closest papers

Nearest neighbours by meaning across the whole index.

A Cost-Effective Submodule with Fault-Blocking Capability for Modular Multilevel Converters

eess.SY ·2026-11-05 ·Yu Liu, Shengbo Zhang
similarity 0.59
Abstract · 11 pages, 22 figures

Modular multilevel converter (MMC) has become an attractive technology for high-power electronics applications thanks to its high energy efficiency, high power rating, high modularity, flexible scalability, and superior output waveform quality. It has attracted considerable research attention, and numerous submodule (SM) variants have been developed for different objectives. Among them, the half-bridge SM (HBSM) is the most widely adopted thanks to its simplicity, but it cannot interrupt DC-side short-circuit currents. Various SM topologies with fault-blocking capability have been proposed. These SM topologies contain additional switches and passive components compared to the HBSM, leading to higher capital and operating costs. Aiming at these issue, an SM topology capable to block DC-side fault-currents with a reduced component count is proposed in this paper. The proposed SM includes two variants, one employs only two fully-controlled switches. An operation and control scheme for the proposed SM are also developed and presented in the paper. The functionality of the proposed SM is validated by experiment, and the value of the SM is demonstrated through a test simulation for an high-voltage direct-current (HVDC) transmission system.

0.30

Adaptive Inductor and Frequency Management for Integrated Power Converters

eess.SY ·2026-10-05 ·Rami Rasheedi, Salma Abdelzaher, Inna Partin-Vaisband
unusual similarity 0.52
Abstract

This work presents a digitally controlled adaptive power conversion framework that dynamically co-optimizes inductor configuration and switching frequency to achieve high efficiency across a wide range of load conditions. Conventional buck converters are typically optimized for a single operating point, leading to efficiency degradation under dynamic loads due to mismatches between inductance, switching frequency, and load current. To address this limitation, a reconfigurable inductor architecture is proposed. With this approach, the effective inductance and switching frequency are adjusted at runtime with on-chip digital controller. An end-to-end design methodology is developed, integrating physics-based analytical modeling, finite element method (FEM) simulations, and an optimization framework to determine preferred operating points across the load range. The resulting configurations are stored in a lookup table and implemented in real time through a low-overhead control scheme. The system explicitly accounts for both inductor and switching device losses, enabling co-optimization of conduction and switching losses within current ripple and continuous conduction mode (CCM) constraints. To ensure robust operation under fast load transients, a hysteresis-based control strategy is introduced to mitigate temporary CCM violations caused by sensing latency. An entry-margin condition is derived under which continuous conduction is guaranteed for a bounded load slew rate. Simulation results demonstrate a 4.5 percentage-point improvement in average efficiency and up to a 32% reduction in average power loss relative to fixed configurations, highlighting the effectiveness of adaptive inductance-frequency management in integrated power delivery systems with dynamic load profiles.

0.54

An Inductively Assisted N :1 Switched-Capacitor Ladder Converter

eess.SY ·2026-11-10 ·Sandeep Reddy Kukunuru, M Mahmudul Hasan Sajeeb, Rohit Reddy Karnaty, Loai G. Salem
similarity 0.50
Abstract

This paper proposes an inductively assisted N:1 switched-capacitor ladder buck (D-SCLB) converter that replaces the output-side switch in the bottom half-bridge of an N:1 SCLB with a small inductor placed in parallel with the ladder capacitors during the demagnetization phase. The flying capacitors share the load current delivery, lowering the average inductor current to (1-M)Iout and enabling continuous regulation with M=D/(N-1+D). A closed-form output-impedance model, valid for arbitrary N under both optimal and uniform switch sizing, is derived and compared against SC, SCLB, FCMC, and DPSC topologies. For a 4:1 48V-to-PoL design, the D-SCLB reduces the average inductor current by up to 20% and improves the equivalent output impedance by up to 30% relative to the SCLB. Two hardware prototypes on a low-cost two-layer PCB achieve a peak efficiency of 96.2%, with the D-SCLB using 49% smaller inductor volume than the SCLB at comparable efficiency. Model predictions agree with measurements to within 1.5% under heavy load.

0.19

An Optimal Power-Flow Grouping Topology for Single-Isolation-Stage Multi-Output Solid-State Transformers

eess.SY ·2026-11-06 ·Yi Hao, Krzysztof Puczko, Levy Ferreira Costa, Liangcai Shu, Dongsheng Yang
similarity 0.49
Abstract · 13 pages, 19 figures. Submitted to IEEE for possible publication

Electric-vehicle dc fast-charging stations and data centers require multiple high-power dc outputs with independently varying demands. Conventional multi-output solid-state transformers typically establish a common dc bus and use downstream dc/dc converters for port-level regulation and, where required, galvanic isolation. A single-isolation-stage solid-state transformer can eliminate this additional high-power interface stage by directly forming multiple isolated outputs from its submodule dc/dc stages. However, because one submodule is generally insufficient for an individual output port, multiple submodules must be connected in parallel, while inter-submodule balancing circuits redistribute power under unbalanced loading. The submodule grouping therefore determines the internal balancing-power paths. Sequential grouping can create long transfer paths and accumulated balancing power, increasing current stress and losses. This paper proposes an optimal power-flow grouping topology that interleaves submodules assigned to different output ports, thereby localizing power redistribution and reducing the power processed by the balancing circuits. Analytical models quantify the required balancing power and its reduction relative to sequential grouping. A coordinated submodule-bypass strategy is also developed, and the remaining output-power capability under different fault scenarios is evaluated. A six-submodule prototype validates the proposed topology. Under the same highly unbalanced operating conditions, the proposed topology reduces the maximum submodule dc-link voltage difference by 63\% and the peak balancing current by 14.5%, while improving the measured efficiency by approximately 5.6% at rated power. Stable post-fault operation is also experimentally demonstrated.

0.40

Non-Blocking Fault Current Limiting Control of Half-Bridge MMCs for MTDC Transmission

eess.SY ·2026-08-31 ·Pengxiang Huang, Shahil Shah
similarity 0.47
Abstract

A key protection requirement in multiterminal HVDC (MTDC) transmission systems is to selectively isolate faulted areas using DC circuit breakers (DCCBs) during DC faults while keeping the rest of the systems in operation. However, in MTDC systems using half-bridge modular multilevel converters (HB-MMCs), the lack of inherent fault current suppression capability in HB-MMCs can cause converter blocking before fault clearance by DCCBs. This work presents an active fault current limiting (AFCL) control strategy for HB-MMCs to mitigate DC fault currents, thus avoiding converter blocking and reducing the breaking capability required of DCCBs. In addition, a systematic approach is proposed to design the AFCL control strategy under converter and network stability constraints. The effectiveness of the proposed strategy is demonstrated through PSCAD on two typical MTDC systems during DC faults.

0.20

Experimental Characterization of SMD Inductors for Cryogenic Power Conversion at 4 K

eess.SY ·2026-10-20 ·Rami Rasheedi, Umeshkumar Patel, Jonathan Baldwin, Antonino Miceli, Inna Partin-Vaisband
unusual similarity 0.45
Abstract

With the increasing complexity and scalability demands of cryogenic electronic systems, such as quantum computing platforms, conversion of power within the cryogenic environment has become a primary concern. Magnetic inductors are among the key components affecting converter performance, as their electrical and magnetic properties can change significantly at low temperatures. In this paper, five commercially available Vishay SMD power inductors are experimentally characterized down to 4 K: DC resistance is measured continuously during cooldown, while frequency-dependent AC inductance and resistance are measured up to 2 MHz at both room temperature and 4 K. The results show substantial DC resistance reductions of 25x-58x at 4 K, while the inductance degrades by only about 5-5.5%. Although cryogenic operation slightly increases the AC resistance (due to the intensified skin effect) and raises core losses, converter-level analysis shows an inductor-only efficiency improvement of approximately 5.3-6.9 percentage points at 1 A, and up to 22.8 points at 3 A. The measured frequency-dependent impedance of each inductor is imported into Cadence and a complete single-phase 24 V-to-1 V buck converter with GaN power devices is simulated at 1, 2, and 3 A at 4 K. The full-converter efficiency at 4 K is shown to improve by 3.0-5.2 percentage points at 1 A and by up to 22.5 points at 3 A for the AC-characterized devices. These findings indicate that commercially available off-the-shelf power inductors remain operationally viable under cryogenic conditions and can simultaneously increase inductor efficiency and reduce the overall power loss in cryogenic power conversion systems.

0.24

Analysis and Demonstration of a Current-Stiff, Isolated Capacitive Bridge Transformer

eess.SY ·2026-11-10 ·Patrick Nowakowski, Cameron Little, Mahima Gupta, Daniel C. Ludois
similarity 0.45
Abstract · 10 pages, 17 figures

The traditional Voltage Source Inverter (VSI) based Dual Active Bridge (DAB) utilizes a transformer at its center to provide galvanic isolation and a turns ratio for step up/down functionality. However, the transformer is often the limiting factor of the DAB, especially as semiconductor switching speeds improve, given steel core losses, winding losses, etc. This paper presents a new DAB architecture based on Current Source Inverters (CSIs) coupled through, and isolated by, an AC capacitive bridge, yielding a system called a Capacitive Bridge Transformer (CBT). The CBT architecture eliminates all magnetic components in the AC portion of the isolated DAB circuit, reducing frequency scaling barriers normally present in DABs. The paper introduces the CBT from the perspective of duality and then develops the DC-DC power flow equations, the internal apparent power equations, and effective turns ratio. The analytical models are verified by steady state and detailed time domain measurements on a 2 kW experimental prototype.

0.39

Data-driven current control of modular multilevel converter-based HVDC transmission system

eess.SY ·2026-11-05 ·Victor D. Reyes Dreke, Rahul Rane, Aleksandra Lekić
similarity 0.44
Abstract · 8 pages, submitted to IET AC and DC Power Transmission (ACDC)

Model-based design (MBD) is a mature framework for designing the current controllers of modular multilevel converters (MMCs) in high-voltage direct current (HVDC) transmission systems. In MBD, linear state-space models are preferred for their good trade-off between accurate dynamics prediction and simplicity. However, first-principle derivations often neglect relevant MMC dynamics, which can hinder controller performance. Data-driven (DD) methods can deliver less biased models that capture parameter uncertainties, control-loop interactions, and grid dynamics, yet they remain under-exploited for controlling MMC currents. This paper studies DD current control method based on integral Subspace Predictive Control (iSPC), synthesized directly from input--output data measured in a high fidelity real-time digital simulator (RTDS), and proposes an initial guideline outlining the main steps for its systematic application to MMC current control. The proposed iSPC is compared against state-of-the-art DD solution, and the findings are validated through simulation studies in MATLAB/Simulink.

0.32