A Cost-Effective Submodule with Fault-Blocking Capability for Modular Multilevel Converters

Yu Liu, Shengbo Zhang

eess.SY ·submitted 2026-11-05 09:13 UTC · v1

Abstract

Modular multilevel converter (MMC) has become an attractive technology for high-power electronics applications thanks to its high energy efficiency, high power rating, high modularity, flexible scalability, and superior output waveform quality. It has attracted considerable research attention, and numerous submodule (SM) variants have been developed for different objectives. Among them, the half-bridge SM (HBSM) is the most widely adopted thanks to its simplicity, but it cannot interrupt DC-side short-circuit currents. Various SM topologies with fault-blocking capability have been proposed. These SM topologies contain additional switches and passive components compared to the HBSM, leading to higher capital and operating costs. Aiming at these issue, an SM topology capable to block DC-side fault-currents with a reduced component count is proposed in this paper. The proposed SM includes two variants, one employs only two fully-controlled switches. An operation and control scheme for the proposed SM are also developed and presented in the paper. The functionality of the proposed SM is validated by experiment, and the value of the SM is demonstrated through a test simulation for an high-voltage direct-current (HVDC) transmission system.

Comment
11 pages, 22 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Non-Blocking Fault Current Limiting Control of Half-Bridge MMCs for MTDC Transmission

eess.SY ·2026-08-31 ·Pengxiang Huang, Shahil Shah
similarity 0.69
Abstract

A key protection requirement in multiterminal HVDC (MTDC) transmission systems is to selectively isolate faulted areas using DC circuit breakers (DCCBs) during DC faults while keeping the rest of the systems in operation. However, in MTDC systems using half-bridge modular multilevel converters (HB-MMCs), the lack of inherent fault current suppression capability in HB-MMCs can cause converter blocking before fault clearance by DCCBs. This work presents an active fault current limiting (AFCL) control strategy for HB-MMCs to mitigate DC fault currents, thus avoiding converter blocking and reducing the breaking capability required of DCCBs. In addition, a systematic approach is proposed to design the AFCL control strategy under converter and network stability constraints. The effectiveness of the proposed strategy is demonstrated through PSCAD on two typical MTDC systems during DC faults.

0.20

Winding the Field, Not the Wire: Overlaying Magnetics to Improve Current Dynamics in Modular Power Electronics

eess.SY ·2026-11-02 ·Jinshui Zhang, Boshuo Wang, Hunter Cullina, Emmy Nelson Madore, Maya Clinton +2 more
unusual similarity 0.59
Abstract

Modular power electronics scale power capacity by distributing it across cascaded modules. State-of-the-art modular multilevel converters further introduce dynamic inter-module switched-capacitor exchange and balancing through parallelization. In larger converters, however, this mode needs inter-module inductance to control the equilibration currents. Specifically, differential-mode inductance limits these currents, but existing solutions require conductor re-routing and introduce parasitic resistance. This work presents a non-intrusive resistance-free differential-mode inductance solution: a figure-of-eight-shaped magnetic core that guides the magnetic flux path around existing conductors, such as high-current bus bars. This design adds differential-mode inductance without modifying the conductors. We fabricated a core that provides a 1.52 uH differential-mode inductance while suppressing the common-mode inductance to only 7% of the DM inductance. The core reduces the inter-module current surge from 20.46 A to 7.76 A. The original conductors remain intact.

0.37

Current-Limiting Control for Fault Ride-Through of LLC-based Solid-State Transformer in Data Centers

eess.SY ·2026-08-27 ·Haoyu Wang, Chi Zhang, Mafu Zhang, Rudy Wang, Peter Barbosa
similarity 0.49
Abstract · Added IEEE submission notice

Solid-State Transformers (SSTs) are increasingly proposed as the interface between distribution grids and data centers due to flexible power flows and fast dynamic response. However, when a short-circuit fault occurs in a load branch, the SST with a voltage-source-type DC-DC stage is forced to shut down due to fault currents. Therefore, current-limiting strategies are strongly needed to prevent catastrophic equipment damage and cascading blackouts by instantly restricting massive current spikes and offering sufficient currents for protection devices to act at the faulted branch. This paper proposes a coordinated DC load fault-tolerant current-limiting and recovery strategy embedded directly in the control of the SST DC-DC stage, avoiding additional hardware cost. Specifically, the fault mechanism of an example LLC resonant converter is studied. Accordingly, a fault detection framework is implemented, a closed-loop current controller is proposed to limit the DC current to a designated value within microseconds by surging the switching frequency and adjusting the duty cycle, and a ramped recovery stage will then restore the DC bus after the fault isolation without inrush currents. Experiments on an LLC converter prototype have verified the feasibility of the proposed current-limiting strategy, enabling faster and lower-cost fault response suitable for resilient data center power architectures.

0.26

Data-driven current control of modular multilevel converter-based HVDC transmission system

eess.SY ·2026-11-05 ·Victor D. Reyes Dreke, Rahul Rane, Aleksandra Lekić
similarity 0.47
Abstract · 8 pages, submitted to IET AC and DC Power Transmission (ACDC)

Model-based design (MBD) is a mature framework for designing the current controllers of modular multilevel converters (MMCs) in high-voltage direct current (HVDC) transmission systems. In MBD, linear state-space models are preferred for their good trade-off between accurate dynamics prediction and simplicity. However, first-principle derivations often neglect relevant MMC dynamics, which can hinder controller performance. Data-driven (DD) methods can deliver less biased models that capture parameter uncertainties, control-loop interactions, and grid dynamics, yet they remain under-exploited for controlling MMC currents. This paper studies DD current control method based on integral Subspace Predictive Control (iSPC), synthesized directly from input--output data measured in a high fidelity real-time digital simulator (RTDS), and proposes an initial guideline outlining the main steps for its systematic application to MMC current control. The proposed iSPC is compared against state-of-the-art DD solution, and the findings are validated through simulation studies in MATLAB/Simulink.

0.32

DC-Link Voltage Regulation in a Single-Isolation-Stage Multioutput Solid-State Transformer for Wide-Range DC Outputs

eess.SY ·2026-11-06 ·Yi Hao, Levy Ferreira Costa, Krzysztof Puczko, Liangcai Shu, Dongsheng Yang
unusual similarity 0.46
Abstract · Submitted to IEEE Transactions on Power Electronics (TPEL) for possible publication

Single-isolation-stage solid-state transformers with balancing circuits eliminate an additional downstream dc--dc conversion stage. However, the remaining isolated converters must directly accommodate a wide output-voltage range. This paper investigates variable dc-link voltage operation of a single-isolation-stage multioutput SST to ease this requirement. Coordinated cascaded H-bridge modulation and embedded four-switch balancing circuits support intentionally unequal submodule dc-link voltages, allowing the isolated-converter input voltages to be adjusted according to the output requirements. The achievable voltage range is determined by relating the required balancing power to the BC transfer capability within the available CHB switching windows, subject to modulation and peak and rms current limits. The analysis quantifies the range extension provided by BC operation beyond modulation alone. For a single-phase-shift dual-active-bridge converter, input-voltage following within this range reduces the calculated peak current and extends the ideal zero-voltage-switching region compared with fixed input. Experiments on a six-submodule SST prototype demonstrate unequal dc-link voltage operation and inter-submodule power exchange. Experiments result on DAB demonstrate reduced current stress and improved efficiency with voltage following.

0.38

Protection challenges and solutions on power systems towards 100% inverter-based resources and energy storage systems

eess.SY ·2026-11-02 ·Alexander Novikov, Luis A. Garcia-Reyes, Anup Joshi, Ahmar Farooque, Junaid Khalid +1 more
published similarity 0.46
Abstract · Danmarks Tekniske Universitetet, Katholieke Universiteit Leuven, Department of Electrical Engineering, Electrical Energy Computer Architectu…

The decarbonization of the energy sector, driven by the Paris Agreement and the European Green Deal, is increasing the share of renewable energy sources (RES) in power systems. Unlike traditional systems, RES-based systems rely on power electronic converters, which creates unprecedented challenges for reliability and resilience. The future power system is expected to combine a low-level AC layer with an upper-level High Voltage Direct Current (HVDC) backbone, which requires new understanding of fault protection, stability, and interaction between AC and DC components, as well as new models and simulation tools. This is especially critical in systems moving towards 100 percent converter-based generation. Protection systems detect, locate, and isolate faults to protect assets while the rest of the system keeps operating. Traditionally, they rely on the large fault currents supplied by synchronous machines. In modern systems, converter controls limit the fault current contribution to about 120 percent of rated current, so relays that distinguish faults from normal overcurrents based on current level may operate incorrectly. In addition, inverter-based resources (IBR) may not inject enough negative and zero sequence current for directional relays to work properly, and converters hold the voltage at a fixed value only within their reach, beyond which it drops quickly. As a result, existing protection schemes may not provide the expected accuracy and reliability. This report reviews the protection challenges identified in recent academic literature for power systems with high shares of converter-based resources. It covers the specific characteristics of RES, the challenges for protection with intelligent electronic devices (IED), the challenges of converter control during faults, and the main solutions proposed in research over the last decade.

0.49

An Interline Multiport DC Circuit Breaker with Power Flow Controller

eess.SY ·2026-11-07 ·Maliha Ferdous, Zhi Jin Zhang, Qichen Yang, Maryam Saeedifard
published similarity 0.45
Abstract

Currently, the high-voltage multi-terminal DC (MTDC) grids face two major challenges. First, fast rise rate and lack of zero-crossing point in DC-side fault currents render AC circuit breakers inoperable. Second, DC line currents are passively determined by terminal DC voltages and line resistances, which inherently limits the capability of changing individual line currents for essential grid services such as power flow management and overloading prevention. To address these two limitations, DC circuit breakers (DCCBs) and DC power flow controllers (DCPFCs) have been developed. The conventional DCCBs are two-port devices installed in series with DC lines at their terminals in an MTDC converter substation, so that any fault current flowing through the line can be rapidly cleared. Additionally, a DCPFC can be installed at line terminals to adjust terminal voltages and power exchanges among adjacent lines. As a result, for a substation that connects to multiple lines, it needs to host multiple DCCBs and a DCPFC, which significantly increases the cost and footprint of both the substation and the MTDC grid. To this end, this work proposes an integrated equipment combining multiple DCCBs and a DCPFC, called the interline multiport DCCB with DCPFC, which can reduce the number of components and enhance the economic feasibility of MTDC networks. This paper presents the topology, operation principles, and component selection procedures of the proposed equipment, and compares it with the state-of-the-art technologies. Electromagnetic transient (EMT) simulation results validate the fault interruption and power flow control performance of the interline multiport DCCB with PFC.

0.38

An Inductively Assisted N :1 Switched-Capacitor Ladder Converter

eess.SY ·2026-11-10 ·Sandeep Reddy Kukunuru, M Mahmudul Hasan Sajeeb, Rohit Reddy Karnaty, Loai G. Salem
similarity 0.45
Abstract

This paper proposes an inductively assisted N:1 switched-capacitor ladder buck (D-SCLB) converter that replaces the output-side switch in the bottom half-bridge of an N:1 SCLB with a small inductor placed in parallel with the ladder capacitors during the demagnetization phase. The flying capacitors share the load current delivery, lowering the average inductor current to (1-M)Iout and enabling continuous regulation with M=D/(N-1+D). A closed-form output-impedance model, valid for arbitrary N under both optimal and uniform switch sizing, is derived and compared against SC, SCLB, FCMC, and DPSC topologies. For a 4:1 48V-to-PoL design, the D-SCLB reduces the average inductor current by up to 20% and improves the equivalent output impedance by up to 30% relative to the SCLB. Two hardware prototypes on a low-cost two-layer PCB achieve a peak efficiency of 96.2%, with the D-SCLB using 49% smaller inductor volume than the SCLB at comparable efficiency. Model predictions agree with measurements to within 1.5% under heavy load.

0.15