CS Paper Radar

Iterative Methods for Solving Feedback-Type Linear Equations under Small Phase Condition

Zhou Xie, Wei Chen, Li Qiu

eess.SY ·submitted 2026-11-03 18:59 UTC · v1

Abstract

This paper investigates iterative methods for solving feedback-type linear equations under small phase condition. We first develop an iterative solution scheme for linear equations with sectorial (semi-sectorial) matrices, i.e., matrices whose numerical ranges are contained in an open (closed) half complex plane. Exploiting the geometric properties of the numerical range, we introduce the notion of numerical-radius contraction as a convergence criterion. Such a scheme, with some extra effort, leads to an iterative method for the feedback-type equations under small phase condition, whose convergence condition is characterized in terms of phase information. This complements classical iterative methods for feedback-type equations based on the small gain condition. A case study on large-scale power networks is presented to illustrate the computational efficiency of the proposed method.

Closest papers

Nearest neighbours by meaning across the whole index.

Linear Approximations Provide Rigorous Conditions for Phase Locking in Oscillator Networks and Power Grids

eess.SY nlin.AOmath.OCphysics.soc-ph ·2026-10-17 ·Iva Bačić, Carsten Hartmann, Philipp C. Böttcher, David Gross, Andrea Benigni +1 more
similarity 0.55
Abstract

Synchronization is a fundamental collective phenomenon in many natural and engineered networks. The stable operation of oscillator networks, such as electric power grids, requires phase locking with phase differences across edges below a given threshold. A central question is whether a given network supports such a state. In this contribution, we extend a convex optimization formulation of the nonlinear fixed point equations of the Kuramoto model, that also describe lossless power grids. Based on this formulation, we derive rigorous and tight bounds on the error introduced by an arbitrary approximation of the original model, in particular linear approximations. The bounds yield edge-wise regions of trust around the approximation, within which the true nonlinear solution must lie. They further provide sufficient and necessary conditions for phase locking under prescribed phase difference limits. Numerical experiments show that the bounds are tight over a broad range of parameters.

0.41

Generalized H matrix stability for power systems

eess.SY ·2026-11-06 ·Elinor Ginzburg-Ganz, Yoash Levron, Juri Belikov, George Weiss
published similarity 0.53
Abstract

The small-signal stability of a power system model with arbitrary loads is investigated, with a focus on locally constant power loads in lossless networks. A central element of the proposed analysis is the matrix H, which represents the partial derivatives of generator powers with respect to their relative angles. The local stability of any equilibrium point is determined by the properties of H if the loads consume locally constant power. Specifically, an equilibrium point is asymptotically stable if H is positive definite and unstable if H is full-rank and not positive definite, while several quantitative relationships between the eigenvalues of H and the system Jacobian matrix are also established. The main contribution is that loads are allowed to be arbitrarily located within the transmission network, thereby generalizing the existing H matrix stability criterion which is valid only if loads are located at the same buses as the generators. The advantage of the proposed criterion is demonstrated through case studies involving systems with up to 2869 buses. Accurate stability assessments are maintained, where alternative methods, such as the NRPS model, are found to be overly conservative. Additionally, a computational acceleration by a factor of 340 relative to Jacobian-based methods is achieved.

0.42

Sparse Generalized-Admittance AC Power Flow for Fast Contingency Analysis and Remedial-Action Assessment

eess.SY ·2026-09-12 ·Pierre Artoisenet, Noémie Verstraete
similarity 0.50
Abstract · 8 pages, 1 figure

Repeated AC power-flow calculations are common tasks in transmission system operations, in particular for contingency analysis and remedial-action assessment. For large networks, their cumulative runtime can become a computational bottleneck in operational processes. This paper develops a sparse reformulation of the generalized bus-admittance power-flow method known as PFPD. Loads and generators are represented by fixed shunt admittance terms on the diagonal of the admittance matrix, while corrective nodal currents are iteratively computed to match the constant-power and regulated-voltage constraints. In contrast to the original formulation, the slack bus is treated as a fixed-voltage boundary and removed from the admittance block decomposition. The resulting iteration reuses sparse LU factorizations of the initial generalized non-slack matrix and its PQ block, without explicitly forming dense inverse matrices. The same formulation admits two initialization modes: an unsolved base case using the same flat-start shunt heuristic as in the primary PFPD method, and repeated post-action calculations initialized from a solved operating point. Localized topology and parameter changes are expressed as low-rank admittance updates and the resulting admittance matrices are inverted by means of the Woodbury identity. An optional local-network formulation can provide an warm start before full-network refinement. N-1 experiments on the 1354-bus and 9241-bus PEGASE systems and the 6717-bus synthetic Texas system yield average per-contingency speedups between 14.4 and 18.0 relative to pandapower. On transformer tap-position actions, the method is 2.8--2.9 times faster than pandapower and 7.2--29.9 times faster than PowSyBl OpenLoadFlow.

0.34

From Rigid to Adiabatic: Canonical Regularization of AC Networks via Action-Angle Variables

eess.SY ·2026-08-29 ·Feng Ji, Lu Gao, Lihui Yang
similarity 0.49
Abstract

Traditional power system analysis relies on timescale separation and the rigid-network assumption, freezing electromagnetic transients into algebraic power-flow equations via Steinmetz's phasor theory. As grid-forming converter penetration increases, magnetic energy dynamics on transmission lines interact with converter control loops on comparable timescales, challenging this rigid-network assumption. Returning to Faraday's law of electromagnetic induction driven by rotating magnetic fields, this paper models the transmission lines' rotating magnetic fields in action-angle canonical coordinates, regularizes the rigid algebraic constraints of power-flow equations into canonical equations on adiabatic symplectic manifolds, and establishes a port-Hamiltonian standard form for AC power grids. Based on the minimal-counterexample principle and using the equal-area criterion's classical two-machine system, this paper reveals a latitudinal instability channel via Bloch-sphere coordinates: Q-V control releases voltage-amplitude freedom, shifting the stability boundary from the equatorial UEP (unstable equilibrium point) to a saddle point, thereby unifying the analytical frameworks of P-delta angle stability and Q-V voltage stability in power system analysis.

0.27

An Analytical Review of Model Order Reduction Methodologies of Converter-Dominated Power Systems for Stability Studies

eess.SY ·2026-10-02 ·Goran Grdenić, Marco Fraccaro, Josipa-Pina Milišić
similarity 0.47
Abstract · 53 pages, 4 figures

The rapid integration of renewable energy sources is transforming modern electric power systems into converter-dominated networks characterized by complex multi-timescale dynamics and new stability interactions over a wide frequency range. Accurate analysis of these phenomena requires high-fidelity models of transmission networks and power electronic converters, which often result in large-scale differential-algebraic systems with significant computational burden. This paper provides an analytical review of model order reduction techniques for converter-rich power systems, with particular emphasis on the key equations employed in the reduction process. Advantages and limitations of commonly used strategies, including timescale-based singular perturbation, projection-based, operator-based, data-driven, and machine-learning based methods, are discussed. The synthesis highlights key challenges related to harmonic interactions and multi-frequency dynamics, and outlines directions for the development of computationally efficient yet dynamically accurate reduced-order models for future power systems.

0.29

Scalable Small-Signal Stability Assessment of Power Systems Based on Frequency-Domain Quadratic Constraints

eess.SY ·2026-09-28 ·Xiaoying Liu, Linbin Huang, Hangyu Chen, Huanhai Xin
similarity 0.46
Abstract

Small-signal stability analysis of power electronics-dominated power systems is becoming increasingly challenging due to the large-scale integration of heterogeneous grid-following (GFL) and grid-forming (GFM) converters. Classical centralized methods, such as eigenvalue analysis and the generalized Nyquist criterion, provide direct stability assessment tools but exhibit limited scalability as the system size increases. This motivates scalable analysis methods for stability assessment and device-level diagnosis, and calls for less conservative stability conditions. To this end, this paper proposes a scalable small-signal stability assessment method with quantitative stability indices for multi-converter systems based on frequency-domain quadratic constraints (FQCs). It is shown that several existing stability conditions, including geometric conditions based on the Davis-Wielandt (DW) shell, numerical range, $x$-$z$ graph, scaled relative graph (SRG), mixed gain-phase condition, and passivity condition, are special cases of the FQC-based stability condition. This FQC-based formulation also clarifies the requirements for decentralized verification of these existing stability conditions. To further reduce conservatism, a full-multiplier FQC-based stability condition is developed, based on which an optimization problem is formulated for scalable stability certification and device-level diagnosis using quantitative stability indices without relying on graphical inspection. Combined with the mixed gain-phase condition, this optimization problem forms a hierarchical screening-diagnosis procedure that improves efficiency. Case studies demonstrate that the proposed method is less conservative than existing criteria and can effectively identify problematic devices associated with potential instability risks.

0.39

Phase Locking in Oscillator Networks with Uncertain and State-Dependent Couplings

eess.SY nlin.AOmath.DSmath.OC+1 ·2026-11-04 ·Iva Bačić, Philipp C. Böttcher, Marc Hunkemöller, Carsten Hartmann, David Gross +2 more
similarity 0.46
Abstract

Phase locking in oscillator networks depends critically on the interaction strengths between coupled units. In many applications, however, these couplings are uncertain, state dependent, or time varying. We derive rigorous conditions for phase locking in Kuramoto-type networks when each coupling strength is known only within prescribed bounds. Building on a convex formulation of the nonlinear fixed-point equations, we obtain edge-wise error bounds for arbitrary feasible approximations that hold uniformly over all admissible couplings. These bounds yield sufficient conditions for the existence of phase-locked states with prescribed phase-difference limits. We illustrate the framework for AC power grids with uncertain voltage magnitudes and adaptive oscillator networks with state-dependent couplings. For the latter, the bounds can be further tightened by exploiting the state dependence of the couplings.

0.10

Explicit Convex Inner Approximation of TSO-DSO Flexibility Regions via Exact Second-order Cone Relaxation in Radial Networks

eess.SY ·2026-10-20 ·Wenyu Liu, Mario Paolone
benchmark similarity 0.46
Abstract · 10 pages, 4 figures

Accurate representations of the flexibility in distribution grids via tractable algorithms are essential for TSO-DSO coordination. However, flexibility region (FR) estimation based on nonlinear optimal power flow (OPF) generally lacks feasibility guarantees, while conventional convex relaxations may suffer from inexactness. This paper proposes a framework for constructing explicit inner approximations of active-reactive power FRs in radial networks based on the augmented relaxed OPF (AR-OPF). First, less-conservative sufficient conditions for the AR-OPF exactness are derived and extended to generalized objectives. Furthermore, an interior-feasibility analysis is established, guaranteeing that the entire region enclosed by the traced boundary is AC feasible under the proposed sufficient conditions. Building on these theoretical results, two adaptive algorithms are developed to construct explicit inner approximations and numerically convex representations of FRs. Numerical evaluations on different benchmark networks demonstrate consistently small relaxation residuals and high flexibility area retention in most cases, showing that the proposed methods provide a grounded approach to construct operationally admissible FRs for TSO-DSO coordination.

0.35