Grid-Compliance Testing of Wind Turbines through Virtualized Component Tests: Testing Concept and Test Bench

Simon Moritz, Yoga Viknesh Kannan, Florian Andresen, Laura Fuentes Grau, Manuel Fischer, Johannes-Martin Hördler, Sabri Özer, Martin Brennecke, Philipp Kersting, Andreas Thul, Simon Steentjes, Ferdinanda Ponci, Antonello Monti, Rik W. De Doncker, Heike Vallery, Maximilian Basler

eess.SY ·submitted 2026-11-13 12:02 UTC · v1
published

Abstract

As the proportion of inverter-connected wind turbines increases, test methods for evaluating their grid behavior are becoming increasingly important. This paper presents a Power Hardware-in-the-Loop (PHiL)-based method for grid connection testing of wind turbines. For the first time, geographically distributed simulations of aerodynamics via the Internet and of the grid model via a fiber-optic connection are integrated into certification-relevant tests. The concept expands upon the methods described in IEC TS 61400-21-4. Initial experimental results confirm high emulation quality and sufficiently low latencies, and meet the requirements for a standards-compliant grid emulation.

Comment
10 pages, 7 figures, 5 tables, peer-reviewed journal article
Journal ref
atp magazin 08/2026, pp. 48-61, 2026

Closest papers

Nearest neighbours by meaning across the whole index.

GFM Control Automatic Compliance Toolbox

eess.SY ·2026-11-08 ·Tejas Kunbi, Rahul Rane, Dan Wu, Aleksandra Lekić
similarity 0.57
Abstract

The increasing penetration of converter-interfaced generation reduces system inertia, short-circuit strength, and voltage support. European grid codes, including the ENTSO-E Network Code on Requirements for Generators and the ACER Demand Connection Code, now define disturbance-based validation procedures for grid-forming (GFM) generation and converter-based demand. Commercial RMS tools, however, lack an integrated workflow aligned with these recent requirements. This paper presents an automated Python-PowerFactory compliance toolbox and an RMS test bench for a co-located system comprising a 1 MW GFM photovoltaic (PV) plant, a 0.3 MW GFM battery energy storage system (BESS), and a 1 MW converter-interfaced dynamic load at a 20 kV point of common coupling fed from a 110 kV grid. Extended virtual synchronous machine models and a DCC-oriented load model are tested in batch, with results automatically extracted and plotted for assessment. Results show compliant RMS performance for the slower, electromechanical tests, while the paper identifies which tests require complementary electromagnetic transient (EMT) verification.

0.34

Guidelines for the implementation of power oscillation damping controllers in power converters

eess.SY ·2026-09-02 ·Javier Renedo, Macarena Martín Almenta, Sergio Martínez Villanueva, Agustín Díaz-García, Antonio Cordón +1 more
similarity 0.53
Abstract

One of the most effective ways to damp electromechanical oscillations in power systems is by means of supplementary controllers attached to the different devices in the power system is by means of power system stabilizers (PSS) in synchronous machines or by means of power oscillation damping (POD) controllers in facilities with power converters. In the recent years, the use of POD controllers in voltage source converters (VSCs) with grid-following (GFL) control has been investigated. Although the potential of POD controllers to help to damp inter-area oscillations in power systems is enormous, their correct implementation is not trivial, because their effectiveness is strongly linked to their settings. This paper provides guidelines for the implementation of POD controllers in power converters for application in real-world power systems. The paper proposes compliance criteria for POD controllers using a synthetic test system and a systematic methodology used in Spanish technical standard for monitoring compliance (NTS), considering practical considerations. The paper also includes numerical examples to illustrate compliance criteria for POD controllers in a synthetic test system. A generic power converter with grid-following (GFL) control is used for the analysis by simulation and POD controllers using modulation of active-power injection (POD-P), reactive-power injection (POD-Q) or both simultaneously (POD-PQ) will be analysed. Results were validated in a large-scale power system. The paper concludes that by using appropriate synthetic systems, methodologies and compliance criteria, POD controllers in power converters could be effective to damp electromechanical oscillation in large-scale power systems.

0.33

An Open Synthetic Test System for the Jordanian Transmission Grid

eess.SY ·2026-08-31 ·Muhy Eddin Zater, Bri-Mathias Hodge
benchmark similarity 0.52
Abstract

Open synthetic test systems are essential for reproducible power system research, yet the available cases represent almost exclusively North American and European grids. No open transmission test system exists for any Middle Eastern country, whose grids raise different questions such as single corridor fuel-supply resilience and high-renewable operation within small synchronous systems, and established benchmarks cannot demonstrate. This paper presents a synthetic test system for the Jordanian transmission grid, assembled entirely from public sources, where the real topology is reconstructed from a published diagram and restored to its 2018 energized state, with plant-level generation and renewable fleets, per-site hourly profiles, and loads calibrated to the values published by Jordan's grid operators. The case is validated through structural statistics against real-grid criteria, power flow and $N\!-\!1$ screening, an energy-weighted loss decomposition, in addition to a full-year production-cost run compared against the published per-plant energy, and cross-solver verification. The model reproduces the annual energy mix at technology level (largest producers within 4\%, system total within 0.1\%), and the released dataset includes the bus-identity key, all scripts, and a post-2019 scenario variant. This test case is designed to benchmark system-level resource adequacy, time-series dispatch and unit commitment, renewable integration, fuel-supply resilience scenarios, interconnection studies and steady-state studies.

0.25

Enhancing Transient Stability of VSG-Controlled Converters Under Grid Frequency Disturbances

eess.SY ·2026-11-13 ·B. Li, Y. Zhang, X. Wang, S. Yang, Z. Hao +1 more
similarity 0.52
Abstract

Strong damping feedback can substantially improve the transient synchronization stability of renewable energy converters employing virtual synchronous generator (VSG) control. However, conventional damping feedback uses the nominal frequency as its reference. When the frequency of a weak grid deviates from nominal, strong damping tends to keep the VSG frequency near nominal. This can sustain a frequency difference between the VSG and the grid and compromise transient synchronization. To address this problem, this paper proposes a complex-frequency-based method to estimate the grid reference frequency from local terminal measurements. The estimated frequency replaces the nominal reference in the VSG synchronization loop, so that damping acts on the frequency difference between the VSG and the real grid. Controller hardware-in-the-loop tests validate the effectiveness of the proposed method under grid frequency disturbances and its robustness to grid parameter uncertainty and adverse grid conditions.

0.26

Limitations of RMS-based Stability Assessment of Converter-based Grids: A Case Study

eess.SY ·2026-08-19 ·Pol Jane-Soneira, Ognjen Stanojev, Francisco Canales Perez, Qian Long, Mario Schweizer +1 more
similarity 0.51
Abstract

The increasing penetration of power electronic converters in industrial grids introduces stability challenges at frequencies well above the electromechanical range of traditional power systems. Commercial software tools typically perform eigenvalue-based stability analysis using root-mean-square (RMS) models that assume a quasi-stationary network, thereby neglecting electromagnetic dynamics of assets --- which is standard practice in power system analysis. This paper presents a case study of an industrial grid where the conventional RMS-based eigenvalue analysis predicts stable operation, while a detailed electromagnetic transient (EMT) simulation reveals growing oscillations, indicating instability. To bridge this gap, we introduce an alternative modeling approach that formulates the network dynamics in the rotating $dq$ reference frame, retaining the differential equations of electromagnetic dynamics. The resulting model enables eigenvalue analysis that correctly identifies the unstable modes, consistent with the EMT simulation results. Our findings highlight a fundamental limitation of RMS-based stability assessment for converter-dominated grids and demonstrate that dynamic impedance models in the dq frame provide a viable path toward accurate small-signal analysis encompassing high-frequency converter-network interactions.

0.32

Evaluating Grid Strength with Rising Penetration of Inverter Based Resources

eess.SY ·2026-09-22 ·Mohammed N. Khamees, Gad Ilunga, Zhongxia Zhang, Richard E. Tuck
published similarity 0.50
Abstract · Accepted for publication in 2026 CIGRE USNC Grid of the Future (GOTF) Symposium

Over the years, Dominion Energy Virginia (DEV) has experienced recurring power quality disturbances, including voltage and power oscillations, particularly in areas with significant inverter-based generation. While these phenomena suggest a potential relationship to system strength, no definitive correlation has yet been established. This paper presents methodologies for assessing system strength across the DEV network and identifying regions that may be vulnerable to such disturbances. To this end, three grid-strength metrics are evaluated: the Simple Short-Circuit Ratio (SSCR), the Weighted Short-Circuit Ratio (WSCR), and the Composite Short-Circuit Ratio (CSCR). Historical event data will be analyzed using steady-state snapshots from DEV's proprietary Analysis on Demand (ANODE) platform, which provides 10-minute interval load-flow data. These snapshots will be processed using a developed software tool to compute system strength metrics. The analysis will investigate potential correlations between system strength and observed disturbances. Where such correlations are identified, the study will further evaluate the impact of deploying synchronous condensers (SynCons) as a mitigation strategy.

0.31

KPG193-ext: A Synthetic Korean Power Grid Test System for Stability Analysis

eess.SY ·2026-11-09 ·Sungyoon Song, Geonho Song, Min-han Yoon, Yong-Hyun Song, Seung Wan Kim +1 more
similarity 0.49
Abstract

Growing shares of inverter-based generation and constrained transmission expansion increase the need to assess stability across operating conditions. Production-cost models provide chronological commitment and dispatch, but stability analysis requires corresponding electrical detail and device dynamics. This paper introduces KPG193-ext, an extension of the synthetic Korean power-grid test system KPG193 that links chronological operating points with detailed electrical and dynamic models. The extension adds synchronous-machine, controller and renewable-converter models, together with explicit voltage levels, generation terminals, inter-voltage and step-up transformers, and reactive compensation. The resulting 731-bus network retains the original 193 regional locations. Daily unit commitment followed by hourly AC optimal power flow establishes 8,760 operating points for 2025, each distributed as paired steady-state and dynamic-model files. Selected-hour studies examine generation-loss frequency response, steady-state flow-voltage characteristics, and rotor-angle response with special protection system actions. The results reveal differences in delivered frequency support, internal voltage stress along regional transfer paths, and the angle-frequency tradeoff of corrective generator tripping. The database provides a common basis for examining the stability implications of commitment, dispatch and corrective action across daily and seasonal operating conditions.

0.32

Comparison of Open-Source PSCAD EMT Models for Large-Scale AI Data Centers in Smart Grids

eess.SY ·2026-11-17 ·Alex Chen, Ahmad Mohammad Saber, Deepa Kundur
similarity 0.49
Abstract · 5 pages, 2 figures, submitted to PESGM 2027

The rapid deployment of artificial intelligence data centers (AIDCs) introduces gigawatt-scale, highly nonlinear, and fast-varying electronic loads that challenge grid voltage regulation, frequency stability, and disturbance ride-through. Capturing their transient behavior during grid faults and rapid computational workload swings requires high-fidelity electromagnetic transient (EMT) simulations rather than root mean square models. However, limited methodologies exist to audit the component-level adequacy of EMT AIDC models. This paper proposes a software-agnostic, 41-point fidelity framework spanning 11 categories that synthesizes 37 criteria from an existing modeling guideline with four novel requirements: frequency ride-through compliance, disaggregated fan and chiller cooling loads, temperature-dependent thermal response, and DC information technology (IT) load representations. Applying this framework to the four publicly available AIDC models in PSCAD/EMTDC reveals varying degrees of completeness: while the models capture IT load transitions, uninterruptible power supplies, and transfer switches for bulk stability studies, critical gaps remain in electro-thermal cooling coupling, internal protective relaying, and site-level controls. Addressing these gaps will enable comprehensive protection coordination and ride-through compliance studies.

0.22