CS Paper Radar

The Race between Protection and Control: Fast Reactive Reserves Against Overvoltage Cascade

Abdallah Alalem Albustami, Mads Almassalkhi, Ahmad F. Taha

eess.SY ·submitted 2026-11-14 03:44 UTC · v1

Abstract

In an overvoltage cascade, each relay trip removes reactive power absorption and raises the voltage at other plants, often faster than controls can act. This paper determines how much fast reactive power to hold, where, and how fast, so that no contingency trips a plant. A trip certificate allows a relay to pick up if it resets before its delay expires, making the sizing a linear program. A necessary condition identifies the relays that only preventive action can protect, and the reserve of one control decreases with the relay delay and increases with its latency. In nonlinear simulations of four systems, the corrective actions prevent every trip within the analysis window for relays without reset hysteresis, and each plant's own set point is the most effective reserve. A 2\% hysteresis or a small error in the relay voltage can change the reserve as much as the relay delay.

Closest papers

Nearest neighbours by meaning across the whole index.

Barrier Function Control for the Interconnection of DC Electronic Loads to Utility Grid

eess.SY ·2026-10-22 ·Grigoris Michos, Christos K. Verginis
similarity 0.55
Abstract · preprint for paper to appear in IEEE ISGT Europe conference 2026

This paper proposes a nonlinear control law that facilitates the safe integration of DC electronic loads to the utility grid. Specifically, by employing suitable reciprocal barrier functions, it is rigorously proven that the closed-loop system guarantees constrained operation within a desired operating region, despite the influence of fast converter dynamics and fluctuating constant power load demand. This way, the proposed controller guarantees safety of the electronic components from surges in power demand and high transients. The theoretic results are validated in simulation scenarios, where the performance of the proposed controller is compared against the conventional saturated-PI controller. Contrary to the latter, the proposed method guarantees stable and safe operation, enhancing the system robustness.

0.16

Power-Swing Blocking Scheme Based on Continuous and Higher-Order Incremental Quantities for Systems with Inverter-Based Resources

eess.SY ·2026-11-05 ·Henrik Johansson, Qianli Xing, Nathaniel Taylor, Xiongfei Wang
similarity 0.55
Abstract · 9 pages, 11 figures

Conventional power-swing blocking (PSB) schemes for distance protection face new and emerging challenges as the penetration levels of inverter-based resources (IBRs) increase. Several papers highlight interoperability issues concerning faster power swings and unconventional impedance trajectories. Revised relay settings are proposed in attempts to deal with the problems. However, the blinder-based PSB methodology suffers from being dependent on the speed of the apparent impedance trajectory over the tiny region between the blinders, making it difficult to distinguish between fast swings and faults. Moreover, blinders have the inherent limitation that they cannot operate if the measured impedance is inside the blinders when the fault is cleared and immediately enters the distance zones during the first swing cycle - an issue often overlooked in the current literature. This paper proposes a novel PSB scheme based on higher-order incremental quantities (IQs) for difficult swing scenarios with IBRs and synchronous generators (SGs). PSCAD/EMTDC simulations of an SG and an implemented grid-forming (GFM) inverter validate its superior performance compared to conventional dual-blinder PSB schemes. The impacts of GFM inverters on the impedance measured by distance relays during the fault-to-swing transition and first power swing cycle are also discussed.

0.39

New Results for Networked Control of Nonlinear Plants Subject to Transmission Delays

eess.SY ·2026-10-17 ·Ruchao Su, Xianwei Li, Shaoyuan Li
published similarity 0.55
Abstract · Accepted by IEEE CDC 2026. Copyright may be transferred without notice, after which this version might no longer be accessible

This paper studies networked control for nonlinear plants subject to several network-induced constraints, with a particular focus on transmission delays. In the context of general nonlinear networked control systems, a standard approach for guaranteeing stability is to construct a storage function, coupled with a single timer variable, to analyze the maximum allowable transmission interval (MATI) and maximum allowable transmission delay (MAD). In this paper, we propose a new approach that assigns each signal that is either \textit{in transit or most recently updated}, to an individual timer variable. This enables the individual characterization and compensation for the dynamics of each potential updating error. Subsequently, based on a novel construction of timer-coupled storage functions, the dynamics of these timer variables is designed and investigated, leading to less conservative conditions on the MATI and MAD than those by the standard approach while still ensuring closed-loop input-to-state stability with respect to external disturbances. Finally, simulation results are given to illustrate the advantages of these new results.

0.31

Protection challenges and solutions on power systems towards 100% inverter-based resources and energy storage systems

eess.SY ·2026-11-02 ·Alexander Novikov, Luis A. Garcia-Reyes, Anup Joshi, Ahmar Farooque, Junaid Khalid +1 more
published similarity 0.54
Abstract · Danmarks Tekniske Universitetet, Katholieke Universiteit Leuven, Department of Electrical Engineering, Electrical Energy Computer Architectu…

The decarbonization of the energy sector, driven by the Paris Agreement and the European Green Deal, is increasing the share of renewable energy sources (RES) in power systems. Unlike traditional systems, RES-based systems rely on power electronic converters, which creates unprecedented challenges for reliability and resilience. The future power system is expected to combine a low-level AC layer with an upper-level High Voltage Direct Current (HVDC) backbone, which requires new understanding of fault protection, stability, and interaction between AC and DC components, as well as new models and simulation tools. This is especially critical in systems moving towards 100 percent converter-based generation. Protection systems detect, locate, and isolate faults to protect assets while the rest of the system keeps operating. Traditionally, they rely on the large fault currents supplied by synchronous machines. In modern systems, converter controls limit the fault current contribution to about 120 percent of rated current, so relays that distinguish faults from normal overcurrents based on current level may operate incorrectly. In addition, inverter-based resources (IBR) may not inject enough negative and zero sequence current for directional relays to work properly, and converters hold the voltage at a fixed value only within their reach, beyond which it drops quickly. As a result, existing protection schemes may not provide the expected accuracy and reliability. This report reviews the protection challenges identified in recent academic literature for power systems with high shares of converter-based resources. It covers the specific characteristics of RES, the challenges for protection with intelligent electronic devices (IED), the challenges of converter control during faults, and the main solutions proposed in research over the last decade.

0.49

On the Achievable Inertia Constant of Inverter Based Resources

eess.SY ·2026-09-28 ·Christos M. Nikolakakos, Hassan Haes Alhelou, Nikos Hatziargyriou
similarity 0.54
Abstract · Under Review in IEEE Transactions on Power Systems

As inverter-based resources (IBRs) displace synchronous generators, the inertia they can actually contribute to the grid becomes a critical planning parameter. Unlike synchronous machines, this contribution is bounded simultaneously by the available energy reserve, the converter power rating combined with voltage ride-through (VRT) obligations, and the inertia-emulation control scheme with its activation delay. This paper derives each bound in closed form and combines them into a unified envelope $\Heff(t,λ,V_g)=\min(\HE,\HP,\HC)$, which uses parameters accessible to the system operator to quantify how much inertia a plant can provide at a given loading $λ$, grid voltage $V_g$, and time $t$ after a disturbance. The analysis shows that below a loading-dependent critical voltage, VRT reactive-current priority does not leave active-current headroom for inertial power injection; that the converter overload ratio $κ$ matters mainly during voltage dips; and that de-loading yields a linear, quantifiable inertia gain, while collocated energy storage (ESS) removes the source-coupling constraint, making grid-following (GFL) and grid-forming (GFM) plants with storage equivalent post-activation, up to the GFL activation-delay discount within short RoCoF measurement windows. Simulations on the IEEE 9-bus system confirm the framework and motivate a two-dimensional inertia capability curve $H(λ,V_{g,\min})$ as a grid-code instrument analogous to the P--Q diagram of synchronous generators.

0.28

Safety Verification for Voltage Control in Inverter Dominated Radial Distribution Networks under Actuator and Sensor Adversarial Attacks

eess.SY math.OC ·2026-10-30 ·Georgios Pantazis, Revi Boelen, Michelle S. Chong
benchmark similarity 0.52
Abstract

This paper develops a safety verification framework for inverter-based radial distribution networks under sensor and actuator attacks. Each customer is equipped with a droop-based controller to regulate its voltage within a desirable bound of a reference, i.e., to achieve safety. In our setting, attacks and disturbances enter the droop-based controllers, while actuator attacks corrupt the reactive power injected into the network. Consequently, invariance of the controller state alone does not guarantee compliance with inverter capacities or customer voltage limits. To address this challenge, we derive conditions to guarantee that the reactive power state remains inside a predefined ellipsoid, while at the same time ensuring that the attacked reactive power injections and customer voltages respect predetermined operating limits that hold uniformly for the entire predefined ellipsoid. Together, these conditions guarantee safety under all admissible disturbances and state-dependent sensor and actuator attacks. Finally, we express the resulting containment condition as a linear matrix inequality (LMI) feasibility problem. A five-customer radial network based on the CIGRE benchmark corroborates our theoretical developments in simulations.

0.26

Relative-Degree Wall Restricts Passivity-Based Stability Analysis in Inverter-Dominant Grids

eess.SY ·2026-08-30 ·Xiaoyu Peng, Zhongze Li, Xi Ru, Xinghua Chen, Feng Liu
top venue similarity 0.51
Abstract

This letter reveals a fundamental limitation of passivity-based distributed stability analysis in power systems. Under the standard formulation, passivity certification inherently imposes a relative-degree compatibility constraint that excludes many high-fidelity inverter dynamic models (e.g., those that include electromagnetic transients). Potential extensions of passivity frameworks are discussed to break this limitation.

0.43

Convex Inner Approximations for Safe AC Dispatch With Device Dynamics

eess.SY ·2026-10-19 ·Ziqing Zhu
similarity 0.51
Abstract

Safe AC dispatch requires both feasible operating points and enough ramping capability to reach the next target. This paper constructs convex inner approximations that connect nonlinear network feasibility, constrained device response, and dispatch-interval tracking. A fixed-point certificate enforces AC operating limits under bounded load uncertainty. Componentwise response envelopes convert heterogeneous device dynamics into affine conditions on measured states and power references. A command governor then combines these conditions with available ramping capability and a hard terminal-error bound. It selects an admissible target through a minimum-deviation objective and holds the corresponding reference while reserved fast regulation remains active. The resulting quadratic program optimizes controllable references and auxiliary variables. Tests on the IEEE 39- and 118-bus systems include 96 single-target executions and 64 transitions in continuous dispatch sequences at five- and fifteen-minute intervals. All 160 transitions satisfy the AC constraints, independent balancing-generator capability checks, and the prescribed regulation-adjusted terminal accuracy. Complete admission-cycle medians are 3.45 and 8.79 ms. A connected synthetic system with 3,200 buses and 1,000 generating units extends the computational assessment to 999 independent references, with a median cycle time of \LargeMedian{} s. The construction provides a tractable link between available ramping capability and safe, timely execution of AC dispatch.

0.19