Every IVUS Frame in Its Place: A Zero-Install Browser Tool for Registering Intravascular Ultrasound to the Coronary Angiogram, and a Path to Angiography-Only Plaque Imaging

Prahlad G. Menon, Srilakshmi Adhyapak

cs.CV cs.AIcs.ETcs.SE ·submitted 2026-11-17 03:26 UTC · v1

Abstract

Intravascular ultrasound (IVUS) shows plaque composition, calcium and stent apposition that the coronary angiogram cannot, but relating each IVUS cross-section to its position on the angiogram is still largely done in the operator's head. Commercial co-registration is tied to vendor consoles and to set-up at acquisition, so archived angiograms and pullbacks cannot be co-registered, and paired data for training AI models remain scarce. We present a semi-automatic registration tool that runs entirely in a web browser, with no installation and no upload. The clinician picks a contrast-filled reference frame (aided by automatic contrast and cardiac-phase analysis), selects or traces the vessel centerline (aided by Frangi vesselness and minimal paths), and pins the pullback ends and visible landmarks; a monotone piecewise-linear map then places every IVUS frame on the vessel, and each case exports as a frame-level training record. The original Python analysis runs unchanged in WebAssembly and videos are decoded frame-accurately with WebCodecs. On 6 angiographic runs the in-browser analysis was bit-identical to the server pipeline on identical frames; browser decoding differed by at most 2 grey levels, suggested reference frames agreed in all runs and the default automatic centerline in 4 of 6. A 546-frame pullback decoded in 5.3 s. On 36 phantoms with known ground truth, the clinician-guided trace stayed inside the lumen along 87-99% of the vessel, whereas the fully automatic centerline fell from 83% to 0% as noise rose and contrast fell. In a registered Left Main case, one side-branch landmark moved mid-pullback positions by 17.5% of the segment. We map where AI can enter each step, up to predicting a virtual IVUS from the angiogram alone, and make the tool freely available online with a one-click demo.

Comment
19 pages, 10 figures, 4 tables. Live tool with one-click demo: https://menonpg.github.io/ivus-xa-registration/?demo

Closest papers

Nearest neighbours by meaning across the whole index.

Modeling Clinical Workflow for SYNTAX Scoring from Coronary Angiography Videos

cs.CV cs.AI ·2026-09-20 ·Suzhong Fu, Jingqi Dong, Xuan Ding, Rui Sun, Yiming Yang +2 more
top venuecode/data similarity 0.63
Abstract

The SYNTAX score is a clinically established tool for assessing anatomical lesion complexity in coronary artery disease and guiding subsequent treatment. However, automated SYNTAX scoring is commonly formulated as a direct regression problem from coronary angiography videos to patient-level scores. In this work, we reformulate SYNTAX scoring as a vessel segment identity-preserving anatomical reasoning problem and propose a hierarchical modeling framework that explicitly aligns learning with the clinical workflow. Our approach maintains vessel segment identity across frames and views, estimates stenosis severity at the segment level, and aggregates evidence hierarchically according to coronary anatomy. Simultaneously, to address the scarcity of domain-specific data, we integrate and complete multiple public coronary angiography datasets, constructing a large-scale resource featuring completed vessel segmentation and derived structural annotations. Experiments demonstrate that vessel segment-level stenosis embedding enhances explanatory power and reduces prediction variability compared to baseline models, with the R^2 score improving by 0.201 and dev STD decreasing by 18.4%. These results highlight the necessity of structure-aligned modeling for reliable and stable automated SYNTAX scoring from multi-view coronary angiography videos. The GitHub link is https://github.com/VersaceSu7/SYNTAX_score_777.

0.43

Beyond Segmentation: Enriching ImageCAS with Coronary Ostia Landmarks, Rooted Centerline Graphs, and Open-Weight Localization Models

eess.IV cs.CV ·2026-11-06 ·Matteo Leccardi, Andrea Moglia, Marco Morandini, Michele Brembilla, Alessandro Nicosia +6 more
code/data similarity 0.61
Abstract · 52 pages including the appendices. Dataset, centerlines, code and model weights: https://hal9000-lab.github.io/

Coronary ostia and centerlines are key reference points for automated analysis of coronary computed tomography angiography (CCTA), from surgical planning to intraoperative vessel tracking. However, the only public ostium annotations cover 77 non-gated aortic scans, not CCTA, while CAT08 and ASOCA (32 and 40 CCTA scans) mark the ostia only implicitly, as centerline start points. This work enriches ImageCAS, the largest public dataset for coronary artery segmentation, with ostium annotations for its 1000 patients and centerline graphs rooted at these new ostia, making it, to the authors' knowledge, the largest public dataset for ostium localization and the only one with centerlines following the official ImageCAS masks and starting at annotated ostia. Three annotators marked each ostium in the first 500 volumes; in the next 500, the candidates of a model trained on the first batch were corrected (human-in-the-loop). Six 3D localization models, trained on ImageCAS, CAT08 and ASOCA, were benchmarked on 58 held-out volumes (50 ImageCAS, 4 CAT08, 4 ASOCA). SwinUNETR-V2 and nnResUNet localized all ostia without failure (>5 mm error), with median errors of 0.70-0.87 mm. Trained on CAT08 and ASOCA alone, SwinUNETR-V2 fails on 34% of right and 53% of left ostia, whereas adding 250 ImageCAS volumes removes all failures. The centerlines were extracted by a deterministic, quality-controlled minimal-path procedure; on ASOCA, they cover a median of 99.5% of the reference length, with a median per-patient mean distance of 0.22 mm between matched reference points and centerlines. Annotations, centerlines, code, and weights are available at https://hal9000-lab.github.io/.

0.45

GeoPose: Patient-agnostic CTA-to-DSA registration through projection-space calibration

cs.CV ·2026-08-17 ·Rudolf L. M. van Herten, Robert Graf, Paula Feldman, Johannes C. Paetzold
similarity 0.61
Abstract

Aligning intraoperative biplanar digital subtraction angiography (DSA) to pre-procedural computed tomography angiography (CTA) requires rapid and accurate 3D-to-2D registration. Optimization-based methods are sensitive to initialization and may require hundreds of iterations, whereas learning-based approaches commonly rely on patient-specific training. We propose GeoPose, a population-trained framework that estimates the C-arm pose in a learned canonical frame and transfers it to the native frame of an unseen CTA through projection-space calibration and transform composition. A population-trained residual network refines the pose, followed optionally by low-budget image-driven optimization. GeoPose requires neither patient-specific adaptation nor explicit inter-volume preregistration. On 80 DSA observations from 20 held-out patients, optimization-free GeoPose achieved a carotid mean projected centerline distance (mPCD) of 5.8 mm and a clDice of 0.45, compared with 14.5 mm and 0.28 for the best-performing baseline, while requiring only 0.15 s. After 25 optimization iterations, GeoPose reached an mPCD of 4.6 mm and a clDice of 0.58 in approximately two seconds. Under the same budget, native-initialized optimization achieved 14.6 mm and 0.15, respectively. GeoPose thus provides rapid native-frame registration with fixed population-level weights and the geometric correspondence required for downstream biplanar 3D vascular reconstruction.

0.28

A multicenter benchmark and clinically structured metric for coronary CTA report generation

cs.CV ·2026-09-01 ·Zhiyu Ye, Yue Sun, Limiao Zou, Cheng Xu, Keting Xu +5 more
benchmarkcode/data similarity 0.59
Abstract

Reliable evaluation of automated coronary computed tomography angiography (CCTA) report generation requires standardized multicentre benchmarks and clinically structured metrics. We established a four-centre benchmark comprising 3,021 CCTA series from 818 patient-report pairs to evaluate seven open-source three-dimensional vision-language models. We developed CSM$_{\text{CCTA}}$, a clinically structured metric for CCTA report evaluation, with patient-, vessel-, and segment-level variables defined according to clinical guidelines. Report pairs are compared at the finest shared anatomical level, and the contributions of different clinical components are weighted based on expert assessments. We estimated these weights using 70 expert-scored cases and evaluated clinical alignment in a non-overlapping set of 30 cases. CSM$_{\text{CCTA}}$ showed a strong correlation with radiologist scores (Pearson's $r=0.97$, $p<0.001$), exceeding the next-best metric, FORTE ($r=0.70$), by 0.27, and agreed with expert preferences in 115 of 160 pairwise comparisons (71.9\%). Under controlled perturbations, CSM$_{\text{CCTA}}$ remained stable to clinically equivalent wording and decreased monotonically with progressive information omission. In the multicenter benchmark, the CCTA-trained C2RG model achieved the highest CSM$_{\text{CCTA}}$ scores across all four hospitals, although its performance remained far from optimal. In contrast, CCTA-irrelevant reports accounted for up to 98.7\% of the outputs from generalist models. Together, the benchmark provides a standardized setting for model comparison, while CSM$_{\text{CCTA}}$ enables clinically structured evaluation of finding agreement and anatomical specificity. These results support a more clinically aligned and anatomically resolved approach to evaluating CCTA report generation. Code is available at https://openi.pcl.ac.cn/OpenMedIA/CSM_CCTA.

0.32

Lessons learned from deploying imaging AI with the open PACS-AI platform

cs.CV cs.CY ·2026-09-22 ·Samuel Kadoury, Julie G. Hussin, Pascal Thériault-Lauzier, Laurent Létourneau-Guillon, Rob Lewis +9 more
similarity 0.59
Abstract · 28 pages (21 main text + 7 supplementary), 3 figures, 1 table

We describe deploying imaging AI at six hospitals through PACS-AI, an open self-hosted platform. The binding constraint is not model accuracy but infrastructure to route studies, display results, capture feedback, and audit what runs. At one center, angiography models completed 515 of 607 jobs (84.8%); failures reflected absent diagnostic views, and 78.1% of 638 clinician ratings were positive. Publishing honest readiness levels for every model is itself a governance practice.

0.31

Self-training for cross-centre coronary vessel segmentation in X-ray angiography using pre-contrast frame subtraction

cs.CV cs.AI ·2026-10-29 ·Danial Moafi, Aida Moafi, Mostafa Aryafar, Ashkan Sami, Maryam Aryafar
similarity 0.59
Abstract · 7 pages, 2 figures, 3 tables

Deep learning models for coronary vessel segmentation in X-ray angiography often perform poorly on data from centres that were not represented in training. Apart from differences in equipment, the labels of the largest public dataset (ARCADE) are incomplete, as only the segments defined in the SYNTAX score are annotated. In this study, we evaluated whether self-training with pseudo-labels can improve performance on external data without additional manual annotation. Pseudo-labels were generated from two sources, namely the predictions of an nnU-Net model trained on ARCADE and a contrast map obtained by subtracting a pre-contrast frame from the same sequence. The nnU-Net predictions were extended along the contrast map, and pixels detected only in the subtraction image were assigned an ignore label and excluded from the loss. Six models were trained and tested on ARCADE and on two external datasets (XCAD and XACV). All first-round models initialised with the baseline predictions performed better than both the baseline and a control model fine-tuned for the same number of epochs. The model trained on the XCAD pool improved the macro-averaged Dice score by 2.7 points (95% CI 2.3-3.2), while the control decreased it by 0.6 points. A second round of self-training did not lead to further improvement. When an external model trained on 50 fully annotated images was used to generate the initial labels, the XCAD Dice score increased from 0.623 to 0.745 without any XCAD labels, although performance on XACV did not improve because large main vessels were missed. These results suggest that the benefit of self-training depends largely on the sensitivity of the model used to generate the initial pseudo-labels.

0.18

CARDEA: Auditable Reasoning Grounded in Spatial Evidence for End-to-End Coronary Angiography Interpretation

cs.CV ·2026-09-07 ·Jia-Jen Lee, Shih-Yen Hou, Kee Koon Ng, Wei-Chun Wang, Shih-Sheng Chang
code/data similarity 0.58
Abstract · 25 pages, 3 figures and 4 tables in the main text; supplementary appendix with 5 figures and 1 table. Model weights: https://huggingface.co/…

Invasive coronary angiography (CAG) is the gold standard for diagnosing coronary artery disease, but interpretation varies substantially among observers. Existing AI systems can improve consistency but lack auditable decision processes and are limited in comprehensive open-ended assessment, undermining clinician trust and clinical adoption readiness. We developed CARDEA, a unified large vision-language model that serves as the inference core of a CAG pipeline. It was trained solely on public datasets and closed-ended tasks in three stages: visual feature alignment, a self-distilled Chain-of-Box (CoB) cold start, and reinforcement learning with verifiable rewards (RLVR) with a CoB reward encouraging bounding-box use in the reasoning trace. We assessed its two study-level diagnoses, dominance classification and complexity assessment, against a dedicated classifier and two interventional cardiologists. Report generation was excluded from training and evaluated zero-shot across stages on an external cohort using vessel-severity macro-$F_1$. CARDEA trailed the classifier on in-distribution dominance but drew level under domain shift (accuracy, 0.91 [95% confidence interval (CI), 0.86 to 0.95]) and was comparable to the cardiologists on complexity assessment (accuracy, 0.90 [CI, 0.82 to 0.97]). Only RLVR improved zero-shot report generation, raising its vessel-severity macro-$F_1$ (0.686 [CI, 0.664 to 0.707]) above the untuned base model (0.513) and over twice the always-normal floor (0.312). CARDEA runs an end-to-end CAG pipeline from raw multi-view videos through keyframe selection to study-level diagnosis while exposing auditable spatial evidence behind its conclusions. RLVR on verifiable closed-ended tasks surfaced open-ended reporting ability that supervised imitation did not. Clinical use requires prospective validation against expert cardiologists.

0.43

MoE-based Feature Adapter for Prompt-free Binary Coronary Artery Segmentation in X-ray Angiography

cs.CV ·2026-08-25 ·Lin Xi, Yingliang Ma
similarity 0.57
Abstract

Accurate segmentation of coronary arteries in X-ray angiography videos is essential for quantitative coronary analysis and image-guided interventions. However, accurate segmentation remains challenging because coronary vessels are thin and exhibit low contrast, while the presence of catheters, guidewires, and complex anatomical background structures can further interfere with vessel delineation. Existing U-Net- and Transformer-based models provide strong baselines, but their shared feature-adaptation pathways may be insufficient for heterogeneous angiographic appearances. In this paper, we propose a prompt-free mixture-of-experts (MoE) feature adapter for binary coronary artery segmentation. Built upon parameter-efficient Vision Transformer adapters, the proposed method uses multiple lightweight experts with input-dependent top-$k$ routing to adaptively refine vessel-related features while limiting active computational cost. Experiments on MOSXAV and external evaluation on XACV show that the proposed method outperforms representative baselines and improves cross-dataset generalisation. These results suggest that MoE-based adapter learning is effective for robust coronary artery segmentation in X-ray angiography videos.