CS Paper Radar

Tempering and few-shot calibration of pathology foundation models improve digital biomarker reproducibility across slide scanners

Frank T Wen, Kyler Rosen, Siddhi Ramesh, Michael Koo, Sara Kochanny, Sasha Jain-Liu, Emma Dyer, Alexander T Pearson, James M Dolezal

cs.AI q-bio.QMcs.CV ·submitted 2026-11-23 20:44 UTC · v1

Abstract

Pathology foundation models underpin a growing number of histology-based cancer biomarkers, but sensitivity to slide scanner-specific image signatures degrades cross-center reliability and reproducibility. We developed a foundation model fine-tuning method that improved consistency in head-and-neck cancer human papillomavirus (HPV) prediction, colorectal cancer microsatellite instability (MSI) identification, prostate cancer grading and breast cancer phenotyping. This tempering method decreased cross-scanner prediction differences by 67.5% for HPV (95% CI 59.0-73.9%), 69.3% for MSI (95% CI 51.9-76.5%) and 63.4%-81.2% for breast signatures. Cross-scanner prostate grade agreement rose from 42.5% to 92.7%. Under full scanner-HPV confounding during training, AUROC fell from 0.80 to 0.68 with original model features but only from 0.86 to 0.84 with tempering. Unlike post hoc feature calibration, tempering used only public data yet matched or exceeded on-site calibration. These findings support tempering to reduce scanner dependence of pathology foundation models.

Closest papers

Nearest neighbours by meaning across the whole index.

One-Slide Calibration of Pathology Foundation Models

cs.CV cs.AI ·2026-10-06 ·Ming Ren Hou, Tianyi Huang
published similarity 0.64
Abstract · Accepted at the NeurIPS 2026 Workshop AI at Scale for Clinical Impact (ASCI): Cancer Pathology Foundation Models

Scanner variation changes how pathology foundation models represent the same tissue. We introduce SlideRuler, which uses other regions within a slide as internal controls to predict a query region's scanner-induced shift. A transfer map learned from paired rescans enables calibration from a single scan at inference while keeping the foundation model fixed. Across two encoders and five SCORPION scanners, learned transfer reduces mean target-to-source embedding distance by 16.3-38.5% relative to raw embeddings. Replacing controls with unrelated same-scanner regions reveals a positive same-slide contribution in all four evaluation settings, including scanner holdout. A source-anchored variant reduces source-feature displacement by 47.7-83.6% relative to learned transfer while retaining most of its alignment gain. By drawing calibration information from the slide itself, SlideRuler offers a path toward more consistent use of frozen pathology models across imaging systems.

0.22

ProtoCouncil: Multi-Encoder Anatomical Prototypes for Prostate Cancer Detection in Micro-Ultrasound

cs.CV cs.AIcs.LG ·2026-11-06 ·Mohammad Mahdi Abootorabi, Nooshin Maghsoodi, Armin Saadat, Obed Dzikunu, Zhuoxin Guo +6 more
similarity 0.60
Abstract · 12 pages, 3 figures, Under Review

Purpose: Micro-ultrasound ($μ$US) is a promising modality for prostate cancer (PCa) detection, but identifying suspicious tissue depends heavily on clinical experience. Models trained on sparse, noisy core-level pathology offer little insight into their decisions and can fail under domain shift. Clinical use needs a traceable decision process and a flag for uncertain predictions. Methods: We introduce ProtoCouncil, in which three foundation encoders (MedSAM, DINOv3 and V-JEPA 2.1) learn case-based prototypes at three anatomical levels: whole gland, needle track and gland sectors. Prototypes are projected onto real training-core regions, and label-free fusion keeps every class logit as a bias plus an exact sum of prototype similarity contributions. Encoder disagreement triggers selective prediction. Results: In five-fold patient-level cross-validation (6,588 cores, 693 patients), ProtoCouncil reaches 82.9% AUROC for clinically significant PCa (csPCa, Grade Group $\geq$3), 4.3 points above the best previously published method. In zero-shot evaluation on two external cohorts, ProtoCouncil achieves higher all-cancer and csPCa AUROC than all previous methods. Nearest same-class exemplars match test-core tumor involvement better than random same-class cases. Externally, csPCa accuracy falls from 79% when encoders agree to 27% when two oppose the fused call. Abstaining on disagreement raises balanced accuracy by 7 and 15 points, while retaining 58% and 54% of the cores. Conclusion: ProtoCouncil grounds core-level predictions in exact similarity-based evidence from real, anatomically indexed training cases, which makes its reasoning interpretable. It achieves the highest csPCa AUROC across three cohorts and identifies unreliable predictions through encoder disagreement.

0.27

Reliability-Aware Benchmarking of Self-Supervised Learning in Histopathology Under 1-10% Label Regimes

cs.CV cs.LG ·2026-11-04 ·Alicem Koyun, Pranjali Changadeo Pingale, Sachin Mote, Gianluca Pizzuti
publishedbenchmarkcode/data similarity 0.59
Abstract · Oral presentation, CIBB 2026 (21st International Conference on Computational Intelligence Methods for Bioinformatics and Biostatistics, Rome…

Expert annotation in digital pathology is expensive, and low-label regimes remain common in realistic histopathology workflows. Self-supervised learning (SSL) offers a practical way to learn transferable representations from unlabeled pathology images, but performance-only evaluation can hide unreliable confidence behavior under domain shift. We present a reliability-aware benchmark of SimCLR, BYOL, and an MAE-inspired masked-reconstruction baseline on PatchCamelyon (PCam; 96x96) and PANDA (prostate cancer) under 1%, 5%, and 10% labeled regimes with frozen-encoder linear probing. To address common single-run concerns, ResNet-18 results are repeated over 3 splits x 3 seeds (n=9) and ViT-B/16 over 1 split x 3 seeds (n=3) under practical compute constraints, with mean+/-std reporting and per-run logs. Beyond AUROC, accuracy, and F1-score, we report Expected Calibration Error and Brier score, OOD confidence diagnostics for cross-dataset PCam<->PANDA scoring, federated-vs-centralized SimCLR comparisons on PCam, and cross-dataset transfer to colorectal histology tiles. SSL improves label efficiency on the more controlled PCam task, while PANDA's noisier patch-level proxy can remain near coin-flip with higher variance. The study highlights that histopathology SSL should be assessed not only by ranking performance but also by calibration, robustness, and transparent reproducibility diagnostics before clinical interpretation.

0.41

HERO: Histology Encoder for Robust Representation in Oncology

cs.CV ·2026-09-28 ·Zhi Li, Eghbal Amidi, Yating Cheng, Tyson Dawson, Gorkem Can Ates +9 more
benchmarkcode/data similarity 0.58
Abstract · 22 pages, 4 figures, 13 tables; author information updated; scientific content unchanged

Foundation models trained on large pathology image corpora now provide strong, transferable representations for computational pathology. Over the past few years a series of such models has been released, each trained on more slides than the last; on standard classification and segmentation benchmarks, the leading models are now separated by small margins. In clinical use, however, the foundation model is applied to images from hospitals, scanners, and staining protocols outside its training data. Encoders generally embed these acquisition factors alongside biological information, which may introduce downstream errors and hinder safe clinical adoption. A pathology foundation model should therefore be robust to acquisition shift without giving up representation quality, yet robustness is seldom the axis along which models are compared. In this report, we introduce HERO (Histology Encoder for Robust Representation in Oncology), a ViT-G/14 pathology foundation model trained with the DINO and iBOT objectives and refined with high-resolution Gram anchoring on a morphology-balanced corpus of 500 million tiles from approximately 575,000 clinical whole-slide images. Across the evaluated public benchmarks, HERO shows the strongest robustness to center, scanner, and stain variation among the compared state-of-the-art foundation models, performs comparably on tile-level classification, segmentation, and gene-expression prediction, ranks first on average across 39 evaluated slide-level clinical tasks, and, under an equal-weighted framework-level analysis, has the best average rank across the six benchmark frameworks.

0.22

Beyond Discrimination: Evaluating Probability Calibration in Radiomics-Image Fusion for Renal Cell Carcinoma Classification

eess.IV cs.AIcs.CVq-bio.QM ·2026-10-09 ·Yuan Liang, Morgan May, Abraham Campbell, Sourav Bhattacharjee, Simon Caton +1 more
top venue similarity 0.58
Abstract · 12 pages. 1 figure. Accepted at the 2026 Irish Conference on Artificial Intelligence and Cognitive Science (AICS 2026). Proceedings forthcom…

Reliable probability estimates are important for the clinical interpretation of machine-learning classifiers, yet radiomics--image fusion models for renal cell carcinoma (RCC) are commonly evaluated primarily by discrimination. Using 396 patients from the KiTS23 dataset, we evaluated whether adding radiomics to four image-model families improved probabilistic performance in addition to discrimination. Seventeen individual models and four probability-average ensembles were assessed using discrimination, probability calibration, and proper scoring measures. Across 12 matched image-only versus fusion comparisons, AUC and AP improved in all 12, while Brier score and negative log likelihood (NLL) improved in 11 of 12 and expected calibration error (ECE) in eight of 12. The 3D MedVAE gated-fusion model achieved the strongest overall individual-model profile. Probability averaging across concatenation, cross-attention, and gated fusion produced favourable point estimates across all five primary metrics relative to image-only models in all four families, although paired-bootstrap support was stronger for Brier score and NLL than for ECE. These findings show that radiomics--image fusion can improve probabilistic prediction quality beyond discrimination, while calibration behaviour varies across image architectures and fusion strategies. We show that our proposed probability-average ensemble models improve discrimination and calibration simultaneously across all architectures in the study.

0.38

Certify, Report, or Refuse: Harm-Constrained Conformal Prediction for Clinical Actions

cs.LG cs.AI ·2026-11-09 ·Zhiyuan Li, Lequan Yu
similarity 0.58
Abstract · Findings of the 6th Machine Learning for Health Symposium (ML4H 2026)

Routing a melanoma case to routine follow-up is a serious action error that diagnostic coverage alone does not rule out. We present Harm-Constrained Risk-Optimal Conformal Prediction (HC-ROCP), a training-free framework that uses frozen classifier probabilities and adds a harm penalty when choosing prediction sets and actions. We test the resulting policies on disjoint calibration splits with multiplicity adjustment. HC-ROCP certifies supported claims, reports descriptive fallback policies, and refuses unsupported subgroup claims. We evaluate these outputs retrospectively on COVID-19 radiographs, ISIC 2019 dermoscopy, and EyePACS-to-APTOS retinopathy transfer. Across ten calibration seeds, HC-ROCP reduces COVID-19 severe-action errors from the exact risk-optimal baseline's 4.68\% to 0.54\%. At a 5\% budget, global claims are certified for COVID-19 and ISIC, but the rare squamous-cell-carcinoma claim is refused. At 1\%, all settings receive descriptive reports. For each budget, we also report the minimum severe-case count needed to pass the global harm gate with zero errors, providing a starting point for further data collection.

0.16

Where slide-level foundation-model classifiers fail on atypical breast lesions

cs.CV cs.AI ·2026-11-14 ·Nerea Hernandez, Luis J. Herrera, Cesar Ramirez, Olga Valenzuela, Ignacio Rojas +1 more
unusual similarity 0.58
Abstract

Whether a ductal breast lesion is called atypical hyperplasia or low-grade carcinoma in situ increasingly determines surgery. However, slide-level classifiers built on pathology foundation models (PFMs) perform worst on these lesions. Using four PFMs, cross-validation on BRACS and preregistered hypotheses, we studied where the classification of atypia fails. Because slides are labelled with their most severe lesion, only 39% of the slides with annotated atypical ductal hyperplasia (ADH) were labelled ADH. Attention ranked the lesion high but rarely first, and showing the model only the lesion helped little, whereas classifiers trained per decision with lesion-level labels improved all four atypical boundaries. ADH regions inserted into benign slides raised the probability of malignancy more than that of atypia. In a hospital with pathologist-labelled single-subtype slides and in HISTAI, benign slides were scored closer to lesions and triage specificity fell from 0.48-0.53 to 0.00-0.07 and 0.22.

0.23

SCOUT: Risk-Guided Foundation-Model Escalation for Robust Tissue Detection in Whole-Slide Images

cs.CV ·2026-11-18 ·Cristian Tommasino, Antonio M. Rinaldi
benchmarkcode/data similarity 0.58
Abstract

Reliable tissue detection is essential for whole-slide image analysis, yet high average segmentation accuracy can conceal failures involving pale tissue, small fragments, and heterogeneous staining. Pathology foundation models offer transferable representations, but exhaustive inference is computationally demanding and may introduce false-positive tissue predictions. We propose SCOUT (Selective Correction of Uncertain Tissue), a risk-guided cascade that selectively refines an initial thumbnail-based tissue mask. A lightweight audit network estimates the spatial distribution of segmentation errors and prioritizes candidate regions for processing by a frozen pathology foundation model. An asymmetric consensus rule integrates the resulting predictions with the initial mask to recover missed tissue while limiting false positives. A calibrated slide-level review score additionally controls the marginal rate of unflagged case-group failures under the calibration assumptions. Evaluation on a public multi-source, multi-stain benchmark shows that SCOUT reduces the proportion of case groups requiring mask correction from 38.1% for the best released detector to 18.6%, with particularly pronounced improvements in immunohistochemistry. Source-held-out experiments demonstrate better generalization than a segmentation network trained on the same annotations, while selective inference achieves an observed failure rate no higher than processing all candidate regions. Downstream, lymph-node classification with SCOUT masks is non-inferior to that obtained with two of the three released detectors evaluated. A variant built on an openly licensed foundation model is publicly released as an installable Python package with trained weights. These results support risk-guided foundation-model inference as an effective approach to tissue detection across heterogeneous histopathology data.

0.24