SigK: rPPG-based key agreement scheme for mHealth

Yanping Wang, Lin Li, Leo Yu Zhang, Jianfeng Wang, Chao Chen, Kok-Leong Ong, Jun Zhang

cs.CR ·submitted 2026-11-24 00:24 UTC · v1

Abstract

As mobile health advances, the use of biomedical sensors for disease monitoring, diagnosis, and treatment is increasing. These sensors often need to be connected through wireless communication technologies to process physiological information from various body parts effectively. Since the data transmitted in these devices usually contain sensitive personal medical information, it is crucial to establish secure communication between devices. In recent studies, the inter-pulse intervals between heartbeats are often used as the key source. They can be extracted from physiological signals such as photoplethysmogram (PPG) or electrocardiogram (ECG), allowing key agreement schemes without pre-key distribution. However, traditional solutions are based on contact measurement devices (e.g., wristbands, chest straps), which limit their applicability in contactless healthcare scenarios. In this paper, we propose a remote PPG-based key agreement scheme to facilitate secure communication between contactless medical devices. We leverage medical devices equipped with cameras to capture remote PPG signals from human faces, and then utilize the signal's power spectral density and peak-peak interval to establish a key agreement with signals synchronously acquired in the Body Area Network (BAN). We have carried out performance evaluations on three publicly available datasets to demonstrate the feasibility of our proposed scheme. In addition, we have also presented a comprehensive proof of the security of our proposed scheme.

Comment
14 pages, 12 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Demo: Matter-Based IoMT Telemetry and Security Analysis

cs.AR cs.ETcs.RO ·2026-11-12 ·Muhammad Hassan, Masooda Bashir, Carl Gunter
similarity 0.60
Abstract

Connected health devices increasingly support health monitoring outside clinical settings, making secure and accessible physiological data important for patients and caregivers. However, device-specific applications and interfaces complicate the integration of readings from different devices. The Matter standard provides standardized device commissioning and protected communication, but its cluster library does not represent the health attribute measurement. We present a preliminary demo study of a Matter-based IoMT testbed with a specific HealthVitals cluster. Implemented in the connectedhomeip SDK on a Raspberry~Pi~5, the cluster exposes simulated heart rate, blood oxygen saturation, and body temperature. We examine commissioning, attribute retrieval, communication under simulated packet loss, and operational traffic through a reference controller. The study demonstrates that this custom telemetry model can operate within the tested Matter configuration without modifying commissioning or secure-session mechanisms. The resulting testbed gives researchers and device developers a concrete platform for investigating health-oriented extensions. It also supports exploration of local telemetry integration that could help patients and caregivers access readings across connected devices.

0.23

Heart Signal (ECG) as Vibration Signature for Human Authentication Using TinyML

cs.CR cs.AR ·2026-10-17 ·Yogeswar Reddy Thota, Student Member, IEEE, Hanan Alsmadi, Student Member +4 more
similarity 0.58
Abstract

Ensuring data security in the era of Artificial Intelligence (AI) and deepfake technology requires robust biometric systems. Conventional methods such as facial recognition, iris scans, fingerprints, and voice recognition are increasingly vulnerable to spoofing and provide only one-time authentication at login. This study introduces an Electrocardiogram (ECG) based authentication framework, compared with Photoplethysmography (PPG), leveraging Tiny Machine Learning (TinyML) for deployment on resource-constrained microcontroller units (MCUs). The proposed method enables continuous authentication, offering ongoing verification throughout device usage, which conventional biometrics cannot achieve. It also serves as a password-free solution, reducing risks of credential loss, theft, or reuse. However, ECG signals vary with physical activity, health conditions, age, and emotional states, requiring robust signal processing and learning algorithms. To address this, efficient TinyML models were designed to mitigate recognition errors from noisy real-time data. Experiments used single-lead ECG signals (Lead I) from UofTDB, MIT-BIH Arrhythmia, MIT-BIH Noise Stress Test, and PTB databases. Spectrograms and spectral features were extracted to train Deep Neural Network (DNN), 1D CNN, and 2D CNN models within the Edge Impulse platform, achieving 98% accuracy. The trained model was converted into TinyML format and deployed on an Espressif ESP-EYE (ESP32, 240 MHz). Support Vector Machine (SVM) models were also applied for benchmarking. By analyzing the number of heartbeats required for reliable recognition, the results show that averaging multiple signals improves tolerance to noise and enhances accuracy. Overall, ECG-based authentication demonstrates strong potential as a secure, real-time, and continuously verifiable method for personal identification on wearable and edge devices.

0.20

A Synchronized Tri-Modality Wireless System for Multi-Point Non-Contact Cardiac Monitoring

cs.AR eess.SPeess.SY ·2026-11-05 ·Wei Ren, Kaili Zhao, Huansheng Yi, Miaoyang Hu, Jianqi Wang +2 more
similarity 0.58
Abstract · 11 pages, 9 figures

Cardiac physiological monitoring is fundamental to evaluating cardiovascular health and diagnosing related diseases. Non-contact radar sensing can capture chest-wall vibrations with spatial specificity, enabling localized physiological monitoring and cardiac assessment. Progress, however, has been limited by the absence of a reliable, research-grade hardware platform for rigorous validation of radar-based methods. Prior systems typically pair radar, namely Doppler cardiography (DCG), with only electrocardiography (ECG) or other coarse references, providing no direct mechanical ground truth and thus constraining fine-grained evaluation of radar outputs. We present a tri-modality wireless system that integrates ECG, seismocardiography (SCG), and DCG under a unified acquisition and control framework for time-aligned recording and analysis. The tri-modality system combines miniaturized wearable ECG/SCG modules with a high-resolution mmWave radar module, supporting spatially resolved sensing and subsequent feature extraction. To our knowledge, this is the first integrated ECG--SCG--DCG hardware system for comprehensive cardiac monitoring; it enables multi-point thoracic acquisition, achieves precise cross-modal synchronization, and maintains specifications suitable for wearable operation. Experiments on a linear-motion platform show close agreement between DCG- and SCG-derived displacements, confirming accurate displacement measurement. Human-subject studies further demonstrate cross-modal consistency and robust extraction of feature points, establishing ECG as the electrical anchor and SCG as the mechanical ground truth for DCG. Overall, the system provides a rigorous, spatially resolved validation platform that advances non-contact cardiac sensing and supports next-generation radar-based monitoring.

0.24

Physiological Information Reliability: Cross-Layer Adaptive Resource Allocation for Cardiovascular Sensing

eess.SP cs.LGcs.NI ·2026-08-31 ·Navaneeth Krishnan Kamalakannan, Janakiraman Kamalakannan, Harinisri Velmurugan
code/data similarity 0.57
Abstract · 6 pages, 4 figures, 3 tables. Submitted to the Machine Learning for Health (ML4H) 2026 Symposium, Findings Track. Code and experimental arti…

Cardiovascular sensing systems must preserve clinically useful information despite signal degradation, wireless losses, energy constraints, and edge-computation latency. We introduce Physiological Information Reliability (PIR), a cross-layer framework that represents physiological information value jointly with wireless, energy, and computation states and uses a contextual bandit to adapt sensing and communication decisions. We integrate multimodal ECG/PPG signal-quality estimation with physiological information value and an adaptive network-coding layer under burst-erasure conditions. Across controlled multiseed experiments, PIR-LinUCB demonstrates a promising low-energy operating point while maintaining medical latency constraints and competitive physiological estimation performance relative to fixed and heuristic policies. We analyze the resulting accuracy-energy-latency trade-offs and identify limitations of proxy PIV estimation and simulated communication dynamics. These results provide an initial computational demonstration of physiological-information-aware resource allocation and motivate future clinical and real-channel validation.

0.30

Impact of Multiple Non-Invasive Biosignals on Cardiovascular Biomarker Estimation via Simulation-Based Inference

cs.LG physics.med-phstat.AP ·2026-08-26 ·Shusaku Maeda, Masahiro Nakano, Tomoharu Iwata, Kenji Komiya, Ryo Nishikimi +1 more
similarity 0.56
Abstract · 8 pages, 5 figures, 2 tables

As the population ages, the number of patients with cardiovascular diseases continues to increase, highlighting the need for early detection before progression to severe and irreversible functional decline. Consequently, estimating cardiovascular biomarkers from non-invasive biosignals, such as photoplethysmography (PPG) and arterial pressure wave (APW) signals, has attracted increasing attention. These signals can be measured using wearable and cuff-type devices. Previous studies have used PPG and APW signals to estimate cardiovascular biomarkers. However, these signals exhibit strong similarities in both the temporal and frequency domains and primarily reflect peripheral and arterial pulse waveforms. Therefore, they may provide limited information about cardiac mechanical function. In contrast, the quantitative impact of additional biosignals, such as ballistocardiography (BCG), which reflect the body's minute mechanical responses to cardiac ejection, remains unclear. In this study, we generated synthetic PPG, APW, and BCG signals from a unified whole-body cardiovascular circulation model and evaluated the complementary contribution of BCG to probabilistic cardiovascular biomarker estimation. We estimated posterior distributions of cardiovascular biomarkers using neural posterior estimation and simulation-based inference. The results showed that adding BCG signals significantly improved estimation performance. Furthermore, even in ill-posed cases where PPG and APW alone produced multimodal posterior distributions, adding BCG yielded unimodal posterior distributions. These findings provide fundamental insights into signal selection for estimating cardiovascular dynamics.

0.28

Evaluating Generalization and Long-Term Stability of Smartwatch-Based Cuffless Blood Pressure Monitoring

eess.SP ·2026-10-29 ·Hongda Huang, Xiao Peng, Xiaoyu Li, Shuailong Tang, Guangpu Zhu +4 more
published similarity 0.55
Abstract · Accepted by the 2026 IEEE EMBS International Conference on Biomedical and Health Informatics (BHI 2026)

Smartwatch-based cuffless blood pressure (BP) monitoring is a promising low-burden solution for long-term cardiovascular management, but practical deployment remains constrained by model complexity, uncertain cross-dataset generalization, and insufficient evidence on long-term tracking stability. This study presents an efficient Signal-Context Gated Fusion Network (SCGBPNet) for cuffless BP estimation from photoplethysmography (PPG) signals. SCGBPNet integrates signal-level representations through self-attention and further incorporates subject-specific contextual information via a compact gated fusion module. On Aurora-BP, SCGBPNet achieved SBP/DBP mean absolute errors (MAEs) of 7.08/4.90 mmHg, compared with 6.44/4.89 mmHg under within-dataset validation on the private smartwatch dataset, indicating a modest within-dataset discrepancy. Cross-dataset transfer from Aurora-BP to the smartwatch dataset increased the MAEs to 8.98/6.47 mmHg, demonstrating substantial cross-dataset degradation. For long-term stability, the proposed method showed low week-to-week performance variation and a low daily decay rate, indicating good stability over a follow-up period of more than one month. Nevertheless, estimation accuracy deteriorated when BP deviated substantially from an individual's baseline. These findings indicate that favorable aggregate MAE alone should not be interpreted as evidence of deployment-ready performance. More systematic and stratified evaluation across dataset settings, BP ranges, and baseline-deviation levels is needed to assess the practical reliability of smartwatch-based cuffless BP monitoring.

0.25

An Energy Efficient Wearable for Monitoring Elderly People Health

eess.SP cs.CY ·2026-08-26 ·M. Much, A Moraes Filho, J. Sieg, F. Hessel, A. Cataldo Neto +1 more
similarity 0.54
Abstract · 8 pages, 11 figures

The aged population is exposed to risk situations, like falls, sudden changes in vital signs, and faints. These situations become common at this life stage due to a decrease in body capacity and illnesses increase. This scenario imposes attention on families and the national health system. Some studies propose to overcome this problem through elderly health monitoring systems based on smartphones, smartwatches, and other equipment that usually cover low-efficient communication systems and low battery life. This paper proposes an efficient health monitoring system based on Sigfox IoT service and a watch-type wearable device for sensing elderly motion, location, and vital signs to predict risk situations designed to achieve at least 30-days of battery life. Our experimental results show that this architecture is a low-cost, low-power, efficient, and feasible elderly health monitoring solution.

0.36

MoWaveQFormer: A Motion-Conditioned Quality-Gated Transformer for Smartphone-Based PPG Heart Rate Estimation

eess.SP ·2026-09-14 ·Swandip Singha, Rifat Bin Reza, Saifur Rahman Sabuj
similarity 0.54
Abstract · Submitted to arXiv. 8 pages, 5 figures

Photoplethysmography (PPG)-based heart-rate (HR) estimation on smartphones remains unreliable in free-living conditions because motion artifacts vary in spectral structure across activities, and benchmarks such as BUT PPG v2.0 label signal quality only as binary good or bad, discarding partially usable data. This study develops an HR estimation architecture that explicitly conditions motion type and signal quality rather than treating both uniformly. We propose MoWaveQFormer, a three-stage architecture trained under ECG supervision. Stage 1 assigns each window a discrete motion group based on accelerometer-derived spectral energy, without trainable parameters. Stage 2 uses this index to select one of the three learnable FIR filter banks for motion-specific spectral shaping of the PPG signal. Stage 3 embeds the resulting sub-bands into patch tokens, re-weights them via a differentiable soft gate derived from the quality label, and encodes them with a Transformer whose pooled output is regressed to HR, trained jointly with an ECG-supervised loss and a pulse-transit-time consistency term. In a subject-independent split of BUT PPG v2.0 (3,888 recordings, 50 subjects), MoWaveQFormer achieved a mean absolute error of 7.85 bpm, the lowest among five methods, with significant improvements over three baselines (Wilcoxon test, p<0.05). Ablation and Bland-Altman analyses characterize each component's contribution. With 816,445 parameters and sub-3-ms latency, MoWaveQFormer suits real-time deployment, pending validation on smartphone hardware. Replacing motion-agnostic filtering and binary quality discarding with differentiable conditioned processing offers a compact pathway to more reliable free-living PPG-based cardiovascular monitoring.

0.18