CS Paper Radar

Weekly top 20 · eess.IV

2026-W45 Nov 02 – Nov 08, 2026

Ranked from 4,954 papers submitted on 7 days.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works
1

TOP: Transmission-Oriented Remote Sensing Pansharpening

eess.IV cs.CV ·2026-11-04 ·Zi-Han Cao, Jing-Ze Liang, Shao-Jie Wu, Jin-Cheng Di, Liang-Jian Deng +1 more
code/dataunusual
Abstract

Pansharpening has been extensively studied as a fundamental image fusion task in remote sensing. However, most existing methods focus on improving fusion quality under the implicit assumption that high-resolution observations have already been fully downlinked to the ground. As a result, existing models are highly vulnerable to perturbations introduced by lossy compression used for downlink transmission. To address this limitation, we present, to the best of our knowledge, the first transmission oriented pansharpening (TOP) framework, which unifies compact latent coding, onboard pansharpening, and efficient downlink transmission within a single satellite-toground pipeline. TOP encodes remote-sensing observations into a compact binary latent space, where a lightweight onboard fusion module can efficiently predict the fused binary latent code. Since only the compact fused code is downlinked, the transmission payload is substantially reduced. Overall, TOP enables low-payload downlink and lightweight onboard processing while maintaining high fusion quality under severe bandwidth constraints. Experiments across multispectral and hyperspectral settings show that TOP consistently achieves superior fusion quality at higher compression ratios than representative pansharpening methods paired with standard lossy codecs. For example, on GaoFen-2, TOP attains a fusion PSNR of 31.4 dB at a downlink compression ratio of 50x. This design also points toward transmissionoriented processing for other remote-sensing tasks. The code will be made available at https://github.com/JingZe-Liang/TOP.git.

0.57
2

Noise-Regularized Training for Learned Image Compression

eess.IV cs.CV ·2026-11-06 ·Renjie Zou, Zhiwei Huang, Dong Jiang
top venuecode/data
Abstract · 22 pages, 4 figures. Accepted as a Spotlight paper at NeurIPS 2026

Learned image compression (LIC) is trained almost exclusively on clean images: the only stochastic perturbation in the loop is an additive uniform proxy injected in the latent domain to keep the entropy model differentiable. Outside compression, by contrast, a long line of work---from Tikhonov regularization and contractive autoencoders through denoising score matching and modern diffusion models---has established that Gaussian noise at the input of a network with a clean target acts as a structured probe of the data manifold rather than as data augmentation. Building on this view, we introduce noise-regularized training for LIC: at every training step we add Gaussian noise to the encoder input while keeping the distortion target, the latent uniform proxy, the hyperprior, and the entropy coding pipeline unchanged. The recipe is architecture-agnostic and adds essentially no training or inference overhead. Across backbones and operating regimes it yields consistent BD-Rate gains: -2.60% on a reproduced ELIC and -0.85% / -1.05% / -2.38% on the Base/Medium/Large scales of a variable-rate DMCI codec, with DMCI-Large reaching -22.02% against VTM-22.0. A second-order expansion of the noisy RD loss accounts for these gains: because the noise enters upstream of the analysis transform, it converts the clean RD objective into a structured $O(σ^{2})$ regularizer comprising an information-weighted encoder-Jacobian penalty (rate side) and a Frobenius contractive penalty on the end-to-end reconstruction map (distortion side). A finite-difference Lipschitz analysis shows corresponding sensitivity reductions of ~12% for the encoder and ~8% for the end-to-end codec, while an exact-JVP test further shows preferential contraction of high-information directions. Code and trained models are available at https://github.com/Googolxx/NoiseRegu-LIC.

0.57
3

Dataset Collections: Challenges of Large-Scale Data Aggregation in 3D Medical Image Datasets

eess.IV cs.CV ·2026-11-06 ·Yannick Kirchhoff, Saikat Roy, Elisa Stegmeier, Hamideh Haghiri, Constantin Ulrich +28 more
top venuetheoryhot direction
Abstract · Accepted at NeurIPS 2026 E&D Track

The development of deep learning-based medical AI depends on high-quality annotated data. Yet, dataset creation remains constrained by the need for expert radiologist annotations, limiting curated datasets to relatively small cohorts. To overcome this limitation, recent efforts increasingly aggregate disparate public datasets into large-scale dataset collections. However, combining datasets at scale often obscures data provenance, introducing substantial risks of reuse propagation, unintended leakage, bias amplification and distorted data distributions. In this work, we study these problems on a massive collection of 565k 3D radiological images across 1034 public datasets and provide practical resources to address them. Firstly, we formalize dataset collections as a distinct paradigm in medical image analysis and characterize their structural challenges, including reuse propagation, duplication, and provenance fragmentation. Secondly, we perform a large-scale empirical study of duplication on this collection and demonstrate extensive exact and near-duplicate reuse across public datasets via perceptual hashing and manual tracing, identifying a lower bound of 118k duplicate pairs. We make the perceptual hashes publicly accessible for comparison through our website, providing researchers with a standardized reference for identifying potential overlaps and shared provenance. Thirdly, since hashing alone cannot detect all duplicates, we introduce MAP (Metadata for Aggregation and Provenance), a lightweight, portable metadata profile for documenting provenance, known overlaps, and deduplication decisions in dataset collections. Our contributions help dataset collections shift from coarse aggregations to reliable and provenance-aware data scaling mechanisms in medical image analysis. A web tool supporting our work is available at https://mic-dct.dkfz.de/.

0.46
4

Beyond Segmentation: Enriching ImageCAS with Coronary Ostia Landmarks, Rooted Centerline Graphs, and Open-Weight Localization Models

eess.IV cs.CV ·2026-11-06 ·Matteo Leccardi, Andrea Moglia, Marco Morandini, Michele Brembilla, Alessandro Nicosia +6 more
code/data
Abstract · 52 pages including the appendices. Dataset, centerlines, code and model weights: https://hal9000-lab.github.io/

Coronary ostia and centerlines are key reference points for automated analysis of coronary computed tomography angiography (CCTA), from surgical planning to intraoperative vessel tracking. However, the only public ostium annotations cover 77 non-gated aortic scans, not CCTA, while CAT08 and ASOCA (32 and 40 CCTA scans) mark the ostia only implicitly, as centerline start points. This work enriches ImageCAS, the largest public dataset for coronary artery segmentation, with ostium annotations for its 1000 patients and centerline graphs rooted at these new ostia, making it, to the authors' knowledge, the largest public dataset for ostium localization and the only one with centerlines following the official ImageCAS masks and starting at annotated ostia. Three annotators marked each ostium in the first 500 volumes; in the next 500, the candidates of a model trained on the first batch were corrected (human-in-the-loop). Six 3D localization models, trained on ImageCAS, CAT08 and ASOCA, were benchmarked on 58 held-out volumes (50 ImageCAS, 4 CAT08, 4 ASOCA). SwinUNETR-V2 and nnResUNet localized all ostia without failure (>5 mm error), with median errors of 0.70-0.87 mm. Trained on CAT08 and ASOCA alone, SwinUNETR-V2 fails on 34% of right and 53% of left ostia, whereas adding 250 ImageCAS volumes removes all failures. The centerlines were extracted by a deterministic, quality-controlled minimal-path procedure; on ASOCA, they cover a median of 99.5% of the reference length, with a median per-patient mean distance of 0.22 mm between matched reference points and centerlines. Annotations, centerlines, code, and weights are available at https://hal9000-lab.github.io/.

0.44
5

Tomographic Sparse View Selection using the View Covariance Loss

eess.IV ·2026-11-06 ·Jingsong Lin, Amirkoushyar Ziabari, Singanallur V. Venkatakrishnan, Obaidullah Rahman, Gregery T. Buzzard +1 more
top venuehighly cited
Abstract · Accepted version of the article published in IEEE Transactions on Pattern Analysis and Machine Intelligence. 11 pages main paper plus 3 page…

Standard computed tomography (CT) reconstruction algorithms such as filtered back projection (FBP) and Feldkamp-Davis-Kress (FDK) require many views for producing high-quality reconstructions, which can slow image acquisition and increase cost in non-destructive evaluation (NDE) applications. Over the past 20 years, a variety of methods have been developed for computing high-quality CT reconstructions from sparse views. However, the problem of how to select the best views for CT reconstruction remains open. In this paper, we present a novel view covariance loss (VCL) function that measures the joint information of a set of views by approximating the normalized mean squared error (NMSE) of the reconstruction. We present fast algorithms for computing the VCL along with an algorithm for selecting a subset of views that approximately minimizes its value. Our experiments on simulated and measured data indicate that for a fixed number of views our proposed view covariance loss selection (VCLS) algorithm results in reconstructions with lower NRMSE, fewer artifacts, and greater accuracy than current alternative approaches.

0.43
6

HIVE-Diff: High Frame Rate HDR Video Reconstruction from a Single LDR Frame and Events

eess.IV cs.CV ·2026-11-02 ·Caixin Wang, Qingrui Wang, Jie Zhang, Ralph Etienne-Cummings
publishedcode/data
Abstract · Accepted to WACV 2027 (Applications Track). 8 pages main paper + 8 pages supplementary material (included as appendix), 12 figures, 5 tables…

High frame rate HDR video is important in applications such as autonomous driving and scientific imaging, where rapid motion and extreme illumination often occur simultaneously. Conventional frame cameras face a trade-off between temporal resolution and dynamic range, while event cameras provide complementary high-speed brightness-change measurements over a wide illumination range. These properties have motivated event-based HDR reconstruction, with existing methods broadly following event-only and hybrid event-frame paradigms. Event-only HDR reconstruction, however, suffers from brightness and color drift due to the lack of absolute intensity references. Hybrid event-frame methods alleviate this ambiguity using low-dynamic-range (LDR) frames as anchors, but most perform one-to-one HDR reconstruction at available LDR timestamps. In this work, we investigate single-reference HDR temporal expansion, reconstructing N HDR frames from one LDR reference and events instead of N aligned LDR observations. We develop HIVE-Diff, an event-conditioned video diffusion framework that decomposes the task into event-guided temporal generation and HDR content completion. Because paired real HDR-event data are scarce, we train on synthetic data and adapt the model to real event domains using LDR-event sequences as proxy supervision with teacher-student distillation. Experiments on synthetic and multiple real-world datasets demonstrate strong reconstruction quality and robust real-data adaptation.

0.43
7

Benchmarking Neural Image Compression with DCT-Based Spectral Diagnostics

eess.IV cs.CV ·2026-11-03 ·Nikolay I. Kalmykov, Razan Dibo, Yujun Du, Yipeng Liu, Ivan Oseledets +1 more
benchmarkcode/data
Abstract · 17 pages, including supplementary material. Code: https://github.com/nkalmykovsk/dct_benchmark_nic

Neural image compression (NIC) models are commonly evaluated with scalar rate-distortion metrics, which do not show how a codec treats individual spatial frequencies. We propose a benchmark that probes codecs with the DCT basis matrix and single-frequency test images. We measure relative off-target energy (leakage), the fraction of reconstruction energy outside the probed frequency, together with target-frequency gain. Exact decompositions and bounds relate these measurements to reconstruction error. At operating points nearest 1 bpp, the BMSHJ, MBT, and Cheng2020 models leave 80-97% of their reconstructed high-band energy outside the target bin and have target-frequency gains of 0.02-0.23, whereas TCM and FTIC attain off-target energy in the classical-codec range. Both probe types identify behavior absent from scalar metrics: released Cheng2020-Anchor models produce extreme pre-clamp outputs on isolated single-frequency inputs. Finally, decoder-only fine-tuning with natural-image and leakage losses reduces basis off-target energy by 90-99.8% across all eight evaluated architectures while keeping the bitstream fixed, at a Kodak PSNR cost of 0.09-0.59 dB.

0.42
8

Shared-Pattern Collaborative Network for Multi-Source Remote Sensing Data Classification

eess.IV cs.CV ·2026-11-02 ·Chenfang Yang, Chuanzheng Gong, Feng Gao, Junyu Dong, Qian Du
publishedcode/data
Abstract · Accepted for publication in IEEE JSTARS 2026

Multi-source remote sensing data classification has received growing attention recently. However, existing methods still struggle to jointly model long-range contextual dependencies and shared spatial patterns across heterogeneous modalities. To address this issue, we propose a Shared-Pattern Collaborative Network (SPCNet) for HSI and SAR/LiDAR joint classification. To enhance cross-modal collaborative learning, Shared-Pattern Collaborative Block (SPCB) is designed by introducing a shared large-kernel operator and a dynamic convolution branch, enabling the network to capture common spatial structures and content-adaptive local features. Furthermore, Region-Adaptive Modality Allocator (RAMA) is developed to assign spatially varying modality weights for reliable feature fusion. Experiments on Houston2013, Augsburg, and Houston2018 datasets demonstrate that SPCNet achieves superior classification performance over several state-of-the-art methods. The code will be made publicly available at https://github.com/oucailab/SPCNet

0.41
9

Dual Flow: Joint Image-Measurement Flow for Inverse Problems

eess.IV cs.CV ·2026-11-04 ·Sevket Ege Yesilyurt, Figen S. Oktem
code/data
Abstract · 17 pages, 8 figures. Our code is available at https://github.com/METU-SPACE-Lab/Dual-Flow

Existing generative model-based approaches to linear inverse problems typically use the acquired noisy measurement to condition or guide sampling in the image domain. In this work, we introduce Dual Flow, a novel joint flow model for solving linear inverse problems by jointly estimating the clean image and its corresponding noise-free measurement from the observation. Specifically, Dual Flow formulates image reconstruction and measurement denoising as a coupled estimation problem, using coupled flows in the image and measurement domains. The acquired noisy measurement $\mathbf{y}_0$ is used only to initialize the measurement state; thereafter, the image and measurement states are jointly updated based on their current values. By construction, the final image and measurement estimates are guaranteed to satisfy the underlying forward model. We derive the sampling updates for the joint flow and show that they are governed by the conditional mean of the clean image given the current joint state. We further derive a closed-form expression for a sufficient statistic of the joint state and show that the required conditional mean can be obtained by solving an image-domain Gaussian denoising problem involving operator-dependent, correlated noise. We train a velocity-prediction network using this formulation to estimate the conditional mean from the derived sufficient statistic. Dual Flow requires no hyperparameter tuning beyond selecting the number of inference steps and achieves substantially shorter reconstruction times than competing methods. Extensive experiments across various linear inverse problems and image datasets demonstrate state-of-the-art performance in both distortion metrics and perceptual quality. Additional analyses assess robustness to model mismatch, as well as the ability to generate diverse plausible reconstructions and characterize reconstruction uncertainty.

0.36
10

Evaluating the Impact of Nonlinear Registration on Longitudinal PET Analysis in a Rodent Stroke Model

eess.IV cs.CV ·2026-11-02 ·Haytham Ziani, El Mostafa Kalmoun, Zohaib Atif, Hyuk-Sang Kwon
top venue
Abstract · Accepted for presentation at the 2nd International Conference on Artificial Intelligence, Security and Networking (CAISN 2026)

Longitudinal rodent positron emission tomography (PET) studies of stroke and neuromodulation rely on accurate registration to a common atlas space to detect group-level effects. Prior work applying ultra-high frequency low-intensity magnetic stimulation (UHF-LiMS) to a rat model of chronic capsule infarct used affine normalization to a Sprague Dawley MRI template without evaluating that choice. We compare a two-stage (affine and nonlinear) pipeline against an affine- only one for rat PET-to-atlas alignment on the same dataset. Across 32 longitudinal [18F]-FDG PET scans (8 rats, 4 timepoints), the nonlinear stage gave a higher Dice similarity coefficient on every scan, and the gain was significant at the rat level. Jacobian determinants showed no folding on the sampling grid. Group-level linear mixed-effects maps of change from baseline (AFNI 3dLME), computed identically under both pipelines, differ in the size, number and location of their suprathreshold clusters. In this dataset, the registration pipeline is therefore a variable that can change the interpretation of downstream group-level analyses.

0.36
11

AdaptivePnP: Fast Auto-Tuned Plug-and-Play for Deconvolution

eess.IV cs.CV ·2026-11-06 ·Haley Duba-Sullivan, Emma J. Reid, Charles A. Bouman, Gregery T. Buzzard
code/data
Abstract · Submitted to IEEE Transactions on Computational Imaging

Plug-and-play (PnP) methods reconstruct images by alternating a data-fitting step with an image denoiser. Their performance depends on two parameters: the step size $γ$ and the measurement noise level $σ$. In practice, $γ$ is often tuned by grid search over validation images and must be retuned whenever the problem setting changes, and $σ$ is assumed known or estimated separately. We propose AdaptivePnP, a PnP framework that jointly estimates $σ$ and $γ$ at every iteration from the data-fitting residual. To do so, we apply the PnP virtual model to the data-fitting proximal map and show that the residual is zero-mean Gaussian with covariance parameterized by $γ$ and $σ$. However, when one parameter is much larger than the other, the residual carries little information about the smaller one and using the maximum likelihood (ML) estimator can degrade the PnP iterations. We therefore introduce the identifiable maximum likelihood (IML) estimator, which restricts the ML estimator to an identifiable window in which the normalized Cramér--Rao bound of every parameter is bounded by a user-specified tolerance. For the virtual model, this window is an interval of ratios $ρ= γ/σ$, so computing the IML estimate reduces to a one-dimensional search over $ρ$. We apply AdaptivePnP to two standard PnP methods, yielding algorithms that require neither a tuned $γ$ nor a known $σ$. On image deblurring and super-resolution, AdaptivePnP matches or outperforms PnP baselines tuned with the true $σ$. Code is available at https://github.com/hdubasullivan/AdaptivePnP.

0.36
12

A Novel Conditional Adversarial Diffusion Model for High-Fidelity OCT-to-OCT Image Translation and Precise Anti-VEGF Therapy Response Prediction in Diabetic Macular Edema

eess.IV cs.CV ·2026-11-02 ·Reza Rasti, Armin Biglari, Sobhan Mohammadi Hafshejani, Alireza Dehghani, Michael J. Allingham +1 more
code/data
Abstract · 18 pages, 8 figures, 6 tables, Submitted to IEEE Journal of Biomedical and Health Informatics

Diabetic macular edema (DME) is a leading cause of severe vision loss among working-age adults. Although intravitreal anti-vascular endothelial growth factor (anti-VEGF) injections currently serve as the first-line therapy for DME, a notable subset of patients fails to respond despite the substantial cost and clinical burden, suggesting they may benefit more from alternative interventions. Automated, noninvasive pre-treatment response assessment could therefore spare non-responders from the current trial-and-error treatment paradigm. In this study, we propose a novel conditional adversarial diffusion framework that synthesizes post-treatment optical coherence tomography (OCT) images from baseline scans, enabling the derivation of each patient's initial response to anti-VEGF therapy. The model was developed with subject-level 5-fold cross-validation on a US cohort (n = 127) and externally validated on an independent Iranian cohort (n = 44). Benchmarked against fourteen baseline and state-of-the-art translation models, the proposed model achieved the best treatment-response prediction performance among the methods evaluated for that task on both cohorts, with balanced accuracies of 85.7% and 93.0% on the US cohort and 85.2% and 95.3% on the external Iranian cohort at the 10% and 20% central subfield thickness reduction thresholds, respectively. Ultimately, this framework offers a decision-support tool to help ophthalmologists anticipate initial anti-VEGF outcomes in DME prior to treatment initiation, toward personalized therapy selection. The source code will be made publicly available upon acceptance.

0.36
13

Progressive Multi-Scale Super-Resolution via Cascaded Bicubic Anchors and Inter-Scale Mutual Refinement

cs.CV cs.LGeess.IV ·2026-11-02 ·Chun-An Lin, Yu-Chia Chang, Chi-Mao Fan, Yen-Chieh Ouyang, Tsung-Jung Liu
code/data
Abstract · 14 pages, 7 figures, 7 tables. Submitted to an IEEE journal. Code and pretrained models will be released at https://github.com/julian135707/…

Super-resolution networks are trained for one magnification factor, so several output resolutions require several models. We propose PMS-SR, a progressive single-input multiple-output network that produces x2, x4, and x8 results in one forward pass, with a Transformer backbone on the low-resolution grid. In Stage 1, each scale is predicted as a residual over the detached bicubic upsampling of the previous scale's prediction. With Dirac and zero initialization, training starts exactly from the bicubic cascade, and each head adds only the band the previous scale lacks. In Stage 2, inter-scale mutual refinement couples the scales in both directions through space-to-depth feedback, deformable alignment, and per-pixel fusion, so x8 features refine the x2 output. Trained on DF2K, the 7.95M-parameter model achieves a higher PSNR than every compared multi-scale method at x4 and x8 on all five standard benchmarks. At x8, it outperforms the x8-specific DRN-L on all of them, leads all compared methods on Urban100, and is within 0.13 dB of the best result elsewhere. Against three single-scale SwinIR-M models, PMS-SR uses 22% of the parameters, runs 2.9x faster on BSD100 inputs, and its outputs agree 6.7-12.4 dB more closely. Code and pretrained models will be released at https://github.com/julian135707/PMS-SR upon acceptance.

0.33
14

Measure Before You Repair: An Explainable Agent for Blind Restoration of Multi-Artifact 3-D MRI

eess.IV cs.AI ·2026-11-02 ·Necati Sefercioglu, Mehmet Ozan Unal, Metin Ertas, Altan Cakir, Isa Yildirim
Abstract · 5 pages, 3 figures, 4 tables. Submitted to ISBI 2027

A brain MRI scan can carry an unknown mix of artifacts, so restoration has to be blind, yet most deep-learning methods are built to correct one known artifact. We present Dx-Rx, an agent in which a multimodal large language model (MLLM) measures suspected artifacts before it repairs them. To our knowledge, it is the first agent to restore whole 3-D MRI volumes, whereas earlier MRI agents restore 2-D slices. In a loop, it looks at slices of the 3-D volume, calls five diagnostic tools (noise, spike, ghosting, bias field, motion) and four restoration tools in any order it chooses, checks each repair, can return to any earlier version to change the order, and ends with a radiology-style report of its diagnostic reasons, the repairs it applied and their results. We simulated up to five artifacts on 148 whole 3-D T1-weighted volumes, at levels calibrated to radiologists' grades of real scans. An MLLM that only looked at the image, as earlier MRI agents do, removed at most 19.7 % of the artifact error. With the best of five MLLMs, Dx-Rx removed a mean 64.5 %, nearly matching the 64.6 % of the same tools given the ground-truth artifacts, which are never known for a clinical scan. With all five models, it made no volume worse and was on par with or better than an expert rule-based pipeline built from the same tools (62.3 %). Code and demo are public at https://itu-biai.github.io/measure-before-you-repair.

0.33
15

Subliminal Learning in Vision-Language Models

cs.CV cs.AIcs.CLcs.LG+1 ·2026-11-04 ·Arman Hatami, Romina Aalishah, Ilya E. Monosov
published
Abstract · Accepted to WACV 2027

Subliminal learning is a phenomenon in large language models (LLMs) where a teacher passes a hidden preference to a student through training data unrelated to that preference. We study whether subliminal learning also occurs in vision-language models (VLMs). We finetune a teacher VLM to prefer a specific animal or facial attribute and use a control teacher from the same base model. Both teachers generate numbers for an unrelated visual task involving geometric shapes. Two students initialized from the same base VLM are finetuned on the same images, using numbers generated by either the biased or control teacher. Across VLMs ranging from 2B to 7B parameters, we find that both animal and facial preferences can transfer through this unrelated task. Students trained on biased-teacher outputs select the target more often than control students, with a difference of up to $\sim$10 percentage points in the animal preference task. Transfer can become stronger with more training data and varies with the target preference, model, and how the numbers are generated. Beyond preferences, we show that the biased student's explanations use more of the same words and phrases as the biased teacher's explanations than those of the control student, even when all three models select the same image. These results matter for training VLMs and show that training on unrelated data may change both a VLM's image preferences and how it explains its choices, and that transfer can become stronger with more training samples.

0.32
16

Deep Plug-and-Play Proximal Distance Algorithm for Robust Principal Component Analysis

eess.IV eess.SP ·2026-11-03 ·Guanhua Liu, Mingjie Shao, Wenxuan Sun, Zhi Liu, Yanlong Zhao
published
Abstract

Robust Principal Component Analysis (RPCA) is essential in signal processing, with applications in hyperspectral imaging, face recognition, and video background modeling. Traditional RPCA methods often suffer from insufficient utilization of data priors and struggle to capture complex image structures. Conversely, advanced deep denoisers like DnCNN, FFDNet, and DRUNet excel at leveraging image data priors but lack physical model constraints and demonstrate poor robustness against structured noise in RPCA tasks. This paper proposes a novel Plug-and-Play (PnP) method for multi-channel RPCA, integrating both the physical generative model and cutting-edge deep priors. Extensive experiments on RGB and hyperspectral datasets show that PnP-PDA achieves better quantitative performance than conventional RPCA methods and state-of-the-art methods, including deep denoisers and tensor RPCA approaches, while preserving visual details.

0.31
17

Measurement-Aware Multimodal LLM for No-Reference Low-Dose CT Quality Assessment

eess.IV cs.CV ·2026-11-05 ·Kerem Basim, Tolga Demiroglu, Mehmet Ozan Unal, Metin Ertas, Isa Yildirim
hot direction
Abstract · 5 pages, 2 figures, 3 tables. Submitted to IEEE ISBI 2027

No-reference image quality assessment (IQA) of low-dose CT predicts the score that radiologists would assign to a slice without a full-dose reference, as needed to compare dose protocols and denoisers. Trained CT IQA networks agree well with radiologists but output only a score, whereas multimodal large language models (MLLMs) can explain a score but perform poorly on CT when only prompted. We propose a measurement-aware MLLM, built on Qwen3.8-27B, that rates a slice from its image together with six image-domain measurements of noise, sharpness, high-frequency content and streaks, given to the language model as percentiles in text. On the LDCT-IQA 2023 test set, it reaches an Overall score of 2.735, on par with the retrained challenge winner (2.735) and MedSigLIP-FiLM (2.713), and substantially above its base MLLM used as a zero-shot agent. Shuffling the measurements at test time reduces the score by 0.048, mostly through noise, but the same measurements also lead the model to assign higher scores to over-smoothed denoised images.

0.31
18

Air-Scan-Based Point-Spread-Function Estimation for Megavoltage CT with Flat-Panel Detectors

eess.IV ·2026-11-02 ·Seemeen Karimi, Joseph Bendahan, K. Aditya Mohan
publishedunusual
Abstract · This has been presented at a conference, proceedings are pending

Accurate spatial-resolution characterization of flat-panel detectors at megavoltage energies is difficult due to long-tailed cross-talk. Conventional measurements at high energy using line-pair gauges or knife-edge phantoms require expensive, carefully fabricated objects and precise alignment, and despite these, scatter from the phantom, detector, and imaging room can further confound the measurement. We present a method for estimating the detector point spread function (PSF) from the mean noise power spectrum (NPS) calculated from repeated radiographs in air. The approach is mathematically equivalent to an autocovariance-based method but is more practical for long-tailed PSFs. We validate the method using simulated air data and Monte Carlo N-particle (MCNP6) calculations of energy deposition in a flat-panel detector. We show that deconvolving the experimental PSF increases the accuracy of transmission radiographs of step wedges. The method requires no phantom or alignments and is straightforward to reproduce.

0.31
19

Covariate-Conditioned One-Step Diffusion for Multi-Horizon 3D Brain MRI Prediction in Aging and Neurodegeneration

eess.IV cs.AIcs.CVcs.LG ·2026-11-05 ·Natenaile Asmamaw Shiferaw, Ali Farki, Deepika Koundal, Jussi Tohka
code/data
Abstract · 5 pages, 2 figures, 4 tables. Submitted to IEEE ISBI 2027

Predicting longitudinal brain changes from magnetic resonance imaging (MRI) can help characterize structural progression associated with aging and neurodegeneration. However, diffusion-based forecasting typically requires iterative denoising, limiting inference efficiency. We propose a covariate-conditioned one-step diffusion framework for multi-horizon prediction of 3D gray-matter density (GMD) maps. Rather than directly generating future anatomy, the model predicts longitudinal GMD changes through residual prediction in a single denoising step. The predicted changes are added to the baseline GMD map to reconstruct future anatomy. The model is conditioned on baseline anatomy, age, diagnosis, APOE4 allele count, and continuous follow-up time. Training combines mean squared error with a Pearson correlation loss to improve the spatial agreement between predicted and observed GMD changes. A unified model supports prediction horizons from 2 to 10 years. On the held-out ADNI test set, our method achieves a $Δ$-Pearson of 0.478, mean squared error (MSE) of $5.176 \times 10^{-3}$, and structural similarity index measure (SSIM) of 0.979, with $Δ$-Pearson reaching 0.582 at 10 years. Without retraining, external evaluation on AIBL yields a $Δ$-Pearson of 0.450, MSE of $4.016 \times 10^{-3}$, and SSIM of 0.985. Ablation studies further demonstrate the benefits of residual prediction, covariate conditioning, and correlation-based supervision. Code: https://github.com/natenaile/OneStepBrainMRI.

0.31
20

Quantifying System-Level Performance Bottlenecks in Hyperspectral Target Detection

eess.IV ·2026-11-06 ·Chase Cañas, John P. Kerekes
unusual
Abstract · 10 pages, 9 Figures, 4 Tables

Discerning core performance bottlenecks in hyperspectral target detection is highly challenging given the complex interplay between sub-systems of the imaging chain (scene, atmosphere, sensor and processing). Prior sensitivity and limitation studies offer narrow insights applicable to specific system configurations. To address the need for broader generalization, an analysis framework was constructed to quantify limitations from large ensembles of model scenarios. Key components of the framework include the use of canonical scene representations and the log-weighted area under the ROC curve (wAUC), a metric well-suited for rare target detection. By analyzing thousands of scenarios, parametric thresholds were quantified where detection performance degrades, corresponding to "knees" in performance curves. A knee significance score (KSS) is introduced to assess the relative importance of these thresholds. The framework an airborne VNIR sensor implanted in 28,000 scenarios using seven system parameters spanning the scene, atmosphere and sensor. Results suggest that aerosol visibility in the 2-6 km range is the dominant limiter in detection, followed by subpixel target percentages of 15-35%, and background clutter modeled using a t-distribution with 3-5 degrees of freedom.

0.30