CS Paper Radar

Weekly top 20 · eess.IV

2026-W46 Nov 09 – Nov 15, 2026

Ranked from 3,982 papers submitted on 7 days.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works
1

Do Underwater Image Quality Metrics Agree with Human Perception? A Benchmark with Human Choices, Simple Edits and Generative Drift

cs.CV eess.IV ·2026-11-13 ·Rishii Kumar Singh, Abhinav Rajput, Dinesh Kumar Vishwakarma
publishedbenchmarkcode/data
Abstract · Accepted at the 6th WVAQ Workshop, WACV 2027. 18 pages including appendix

Underwater image enhancement is challenging to evaluate due to the lack of clean reference images, so researchers rely on no-reference image quality assessment (NR-IQA) metrics. However, it remains unclear whether these metrics agree with human judgments. We evaluate 73 handcrafted underwater, learned underwater, vision-language and general-purpose metrics against human preferences on five references: four published opinion-score sets and a new paired-comparison study. For each metric, we measure how often it selects the same image as people when comparing versions of the same scene. We further test whether simple image edits and small adversarial perturbations raise metric scores above the enhancement people preferred, and whether scores decrease as repeated generative edits add noise. Our results show that no metric consistently matches human preferences. The best worst-case Cohen's kappa over the five references is only 0.23 (Q-Align), while two raters in our study agree with a median kappa of 0.41. The widely used UCIQE often favors edits that people reject. On a Nano Banana Pro replica chain that should leave the image unchanged, only 22 of 73 scores decrease at every checkpoint, while noise grows by 2.5 times. We also introduce TrustUIQA, a benchmark that combines the human references, our study choices, the edited, attacked and generated images, and the scores of every metric on every image. The code is available at https://github.com/TrustUIQA/TrustUIQA and TrustUIQA at https://huggingface.co/datasets/TrustUIQA/TrustUIQA.

0.54
2

Distribution Shift Detection in Remote Sensing Imagery using Machine Learning Models

cs.CV cs.LGeess.IVeess.SP ·2026-11-10 ·Abdullah Almansour, Ozan K. Tonguz
publishedcode/datahot direction
Abstract · Accepted as a short paper at the 4th Workshop on Computer Vision for Earth Observation (CV4EO), held in conjunction with WACV 2027

Remote sensing imagery acquired by Unmanned Aerial Vehicles (UAVs) supports wide range of applications; however, deploying machine learning (ML) models on resource-constrained aerial platforms introduces challenges beyond predictive accuracy, particularly when deployment data differ from the distributions observed during training. Such shifts are common in remote sensing due to geographic, sensor, seasonal, and other visual variations. A practical solution is to equip deployed models with mechanisms that detect emerging distribution shifts and support subsequent responsive actions. This paper presents an empirical case study of three open-source detection tools: (i) Alibi-Detect; (ii) NannyML; and (iii) PyTorch-OOD. Using cross-dataset remote-sensing shifts, we evaluate both detection effectiveness and computational latency of these tools. Our results reveal differences in detection behavior and processing cost across methods and implementations, highlighting trade-offs between detection capability and response-time. These findings motivate further work toward lightweight, and latency-aware monitoring mechanisms for resource-constrained systems.

0.46
3

Learned Regularization for Sparse-View CT: Accuracy, Lesion Detectability and Distribution Shift of a Plug-and-Play Prior against Tuned Total Variation

eess.IV cs.CVeess.SP ·2026-11-13 ·Mohammed Abo Oraig
code/data
Abstract · 62 pages, 22 figures, and 30 tables. Preprint (not peer-reviewed); also available on Zenodo: https://doi.org/10.5281/zenodo.24107061. Code a…

Learned image priors are often proposed to replace hand-crafted regularizers in sparse-view computed tomography (CT), yet they are usually judged by PSNR on data resembling their training set. We evaluate one noise-conditioned DnCNN denoiser used as a Plug-and-Play prior against filtered back-projection (FBP), Tikhonov and total-variation (TV) regularization, with every method tuned on validation data and all differences paired. On synthetic 28x28 digit images, the prior beats box-constrained TV by about 3.4 dB at moderate noise (sigma = 0.05, 20 angles), but the advantage shrinks at low noise and reverses under distribution shift: an MNIST-trained prior is 3.1 dB (Fashion-MNIST) and 4.3-4.6 dB (Shepp-Logan phantom) below TV, whereas a Fashion-MNIST-trained prior beats TV by 2.2 dB on Fashion-MNIST, consistent with prior mismatch rather than a failure of PnP itself. In a lesion-insertion test the prior detects lesions worse than TV in distribution despite its higher PSNR, and under mismatch it produces more lesion-like false blobs than box-constrained TV for seven of eight lesion types. On real LoDoPaB-CT slices (patient-disjoint split; 30, 60 and 120 angles; three dose levels; 40 test patients), the prior does not consistently outperform a well-tuned TV in PSNR (-0.93 to +0.33 dB) and has lower SSIM in eight of nine conditions. Its lesion-detection AUC is higher than this TV's in all nine conditions (significant in six) but never significantly higher than that of Hann-filtered FBP, which the PSNR-tuned TV falls below in detection in all nine conditions (seven significant). On non-anatomical phantoms its PSNR falls below TV in all six conditions. PSNR and lesion detectability thus rank the methods differently. Our conclusions concern one small denoiser, and the CT analysis was developed after seeing results, without pre-specified primary comparisons.

0.42
4

MRFoundry: Knowledge-guided agent loops for end-to-end MRI research

eess.IV cs.AI ·2026-11-09 ·Ke Wang, Atakan Topcu, Hossein Momeni, Molin Zhang
code/data
Abstract · 18 pages, including 6 pages of Supporting Information. Code: https://github.com/KeWang0622/MRFoundry

AI agents can write code, use scientific software, and revise computational workflows, opening new possibilities for MRI research. Effective assistance requires connecting acquisition physics, data conventions, specialized tools, and scientific validation. We present MRFoundry, an open-source, extensible package that connects MRI knowledge to agent actions and output checks. Project-local memory preserves decisions and evidence, while reviewed contributions allow researchers to improve shared guidance. Researcher-supervised examples demonstrate skill-guided sequence auditing and acquired-data reconstruction, connecting tool use, output checks, and documented decisions. Alongside MRFoundry, we introduce MRI Agent Bench to compare agents with and without the package across models and MRI task domains. Across 240 paired Core evaluations spanning 24 task types and ten models, all-checks-passed completion increased from 67.5% without MRFoundry to 78.3% with it. Across 134 Hard pairs, completion increased from 36.6% to 44.8%. MRFoundry makes MRI workflow expertise available as reusable guidance that researchers can inspect, adapt, and extend within existing agent and scientific software environments. MRFoundry is openly available at https://github.com/KeWang0622/MRFoundry.

0.41
5

Is a CNN-Transformer Ensemble Worth It When a Chest X-Ray Foundation Model Is Available?

eess.IV cs.CV ·2026-11-09 ·Aditya Seelaboyina, Irfan Khan
code/datahot direction
Abstract · 8 pages, 2 figures, 10 tables. Code: https://github.com/adityaseelaboyina/cxr-ensemble-vs-foundation-model

Ensembles of ImageNet-pretrained convolutional networks and Vision Transformers are a common way to improve multi-label chest X-ray classification. We ask whether such an ensemble is still worth its cost when a model pretrained on chest radiographs is available. On the official patient-disjoint split of NIH ChestX-ray14 (25,596 test images, 2,797 patients), we train five ImageNet-pretrained backbones and the EVA-X-S foundation model with validation-only model selection, compare five fusion rules, and estimate every difference with a patient-level paired bootstrap. EVA-X-S alone reached a test macro-AUROC of 0.828; the five-model ensemble reached 0.814 (difference -0.0136, 95% CI -0.0178 to -0.0098) at about 7.8 times the summed backbone latency and ten times the parameters. Averaging the five ImageNet models with EVA-X-S changed AUROC by -0.0056 (-0.0095 to -0.0021). With all five ImageNet backbones trained with the EVA-X-S recipe, their ensemble scored 0.817, still -0.0109 (-0.0142 to -0.0076) below EVA-X-S, and across three seeds EVA-X-S varied by at most 0.001 AUROC. Under the ImageNet models' recipe, however, EVA-X-S fell to 0.798. Our full-stacking configuration never outperformed calibrated averaging. In this setting, the tested ImageNet ensembles did not improve on a single chest X-ray foundation model fine-tuned with its own recipe.

0.38
6

Physics-Informed Generative Augmentation for Open-Set UAV Classification

eess.SP eess.IV ·2026-11-11 ·Michel Kulhandjian, Levon Aslanyan
published
Abstract · Accepted by ICT Express

Open-set recognition of unmanned aerial vehicles (UAVs) from passive 5G radar micro-Doppler signatures is challenging because unknown drone types cannot be anticipated at training time. We propose a physics-informed generative adversarial network (PI-GAN) that conditions spectrogram synthesis on rotor kinematics, forcing the classifier's feature space to encode physically meaningful structure. We compare PI-GAN augmentation against a vanilla conditional GAN (CGAN) and basic data augmentation across three held-out configurations with 1, 2, and 3 unknown classes. Vanilla CGAN augmentation collapses open-set clustering, reducing the adjusted Rand index (ARI) from 0.97 to 0.01, whereas PI-GAN preserves it at 0.97. In a controlled held-out sweep with two unknown classes, PI-GAN achieves an ARI of 0.92 compared to 0.07 for vanilla CGAN. The physics-informed features enable unsupervised separation of mechanically distinct unknown drones without retraining, demonstrating that physics-conditioned generation is the key enabler of open-set capability.

0.38
7

Mutual Colormap Dependence: How Recoloring Biomedical Images Changes Vision-Language Model Answers

eess.IV ·2026-11-11 ·Siddharth Vohra, Runmin Jiang, Min Xu
publishedcode/data
Abstract · Accepted to the FABRIC workshop at WACV 2027. 10 pages, 1 figure, 5 tables. Project page: https://siddvoh.com/mutual-colormap-dependence/

Vision-language models (VLMs) are being built to answer questions about biomedical images, yet they never see the measured intensities, only the colors that a colormap has assigned to them. For questions about image content, the colormap should not change the answer. We call the extent to which it does Mutual Colormap Dependence (MCD), the mutual information between the colormap and a model's answer, which is zero exactly when every colormap yields the same answer distribution. Because VLMs sample their answers, we compare recoloring with a control that uses the same number of calls to ask again about the unchanged gray image, so that ordinary resampling is not mistaken for an effect of the colormap. We test GPT-5.4, Gemini 3.1 Pro, Claude Sonnet 4.6, and Qwen3-VL-235B under six luminance-monotonic colormaps (gray, viridis, plasma, inferno, magma, and cividis) on 50 medical visual-question-answering items from 16 SLAKE images, 64 ChestX-ray14 chest radiographs, and 200 BBBC039 fluorescence-microscopy images for exact nucleus counting. Every prompt tells the model to ignore the colormap. Even so, with three answers per colormap on the chest radiographs, the answers of all four models depend on the colormap (all Holm-adjusted $p \leq 0.002$). For Claude, some colored map overturns the majority answer on 29 of the 64 radiographs, where resampling gray alone overturns about 4, and Qwen's accuracy falls from 0.54 under gray to between 0.32 and 0.41 under the colored maps, mostly because it abstains. With one answer per colormap, recoloring adds disagreement beyond repeated sampling in 5 of 12 model-panel cells under per-cell 95% intervals, and repeating the instruction to ignore color does not reliably reduce it. The colormap is therefore part of what a VLM sees, and it can change the answer.

0.37
8

Foundation Model Fine-Tuning with Attention-based Multi-View Fusion for Multi-Task Cardiac Function Assessment

eess.IV cs.AIcs.CV ·2026-11-13 ·João Freitas, Warre Snaet, Jan D'hooge, Sandro Queirós
published
Abstract · 9 pages, 1 figure. Original pre-peer-review manuscript. Accepted for publication in the MICCAI 2026 Satellite Events (Workshops and Challeng…

In cardio-oncology, left ventricular ejection fraction (LVEF) is the standard biomarker for monitoring cardiac function during cancer therapy. However, its estimation from echocardiography is highly operator dependent, and clinically meaningful declines are often detected only after myocardial injury has progressed, motivating automated methods for standardized assessment and earlier detection of LV dysfunction. To address this need, we propose a multi-task framework integrating cardiac cycle-based temporal standardization, multi-view spatiotemporal feature extraction, and joint optimization for LVEF estimation and LV dysfunction classification. Apical four- and two-chamber echocardiographic sequences are temporally standardized by sampling a clip over an estimated cardiac cycle before being processed by the EchoPrime foundation model, which is fine-tuned end-to-end within the proposed architecture. View-specific features are fused through an attention-based aggregation module to generate a patient-level embedding, from which two task-specific prediction heads estimate continuous LVEF and binary LV dysfunction. To broaden the LVEF distribution encountered during training, samples from the MIMIC-IV-ECHO dataset are incorporated using a balanced sampling strategy. Evaluated on the EchoRisk-MICCAI Challenge, our method achieves an MAE of 4.003 for LVEF estimation (Task 1) and an AUC of 0.764 for LV dysfunction detection (Task 2) on the validation set, demonstrating the effectiveness of foundation model fine-tuning with attention-based multi-view fusion for automated cardiac function assessment in cardio-oncology.

0.37
9

Ultrasound Elastography: Excitation Methods and Low-Cost Alternative

cs.CV eess.IV ·2026-11-11 ·Corin F. Otesteanu
published
Abstract

Ultrasound elastography (or elasticity imaging) is a method that characterizes the tissue mechanical properties with the purpose of aiding the diagnosis of certain pathologies. Many novel clinical applications use the assumption that these tissue properties are changed in the presence of pathological processes. Characterization of tissue mechanical properties is achieved by imaging the response of the tissue to an induced stress or excitation. A plethora of approaches have been used in the scientific community to induce excitation in tissue, which usually require additional tools or devices than are costly. Furthermore these are usually integrated in the imaging pipeline using additional software or hardware for control. An alternative that is simpler, faster to integrate (and low-cost) is proposed in this work, by using readily available smartphones as a source of mechanical excitation. The induced displacements are used to solve the elasticity inverse problem (IP) using a finite element method (FEM) approach. Preliminary elasticity reconstructions of a phantom that mimics tissue are similar to when using a dedicated actuator as means of inducing harmonic displacements, illustrating the feasibility of our low-cost ultrasound elasography approach.

0.36
10

Image Quality and the Reliability of Fabric-Density Measurement: Counting Threads from Smartphone Photos Through a Pick Glass

cs.CV eess.IV ·2026-11-09 ·Anoubhav Agarwaal
publishedbenchmark
Abstract · Accepted at the WVAQ workshop at WACV 2027

Thread density, the threads per inch along and across a woven fabric, is a basic specification that buyers check whenever fabric is sold. Without laboratory instruments, inspectors count it slowly, by eye, through a pick glass, a folding 10$\times$ magnifier with a one-inch window. A smartphone photo through that glass could make the check faster and leave a record. We judge such a photo by what it is used for, as in task-based image quality: it is good if the thread count from it is within $\pm$5% of the true count, a common tolerance in fabric specifications. We introduce PickGlass-TPI: 76 factory scenes of 44 fabric patches, each counted in an open annotation tool by a textile-trained annotator, whose counts are the reference. On it we benchmark frontier and open vision-language models, CNNs, counting specialists and a training-free spectral counter (PG-Lattice). No method agrees with the reference within the tolerance. The best methods are off by about a quarter: a small open model that we tuned only on synthetic images (Molmo2-4B, 25%) is level with the best frontier model, GPT-6.1-sol (27% when asked directly, 25% given four magnified close-ups of the window). Both err less than a non-expert annotator (37%), but only the tuned model also beats, on both error measures, a baseline that guesses each scene's density as the average of the others. PG-Lattice most often repeats its count within 5% across two photos of the same patch, but its misses, like GPT-6.1-sol's errors, are often a factor of two. Even the reference repeats a count across such re-shoots only to a median 9%, so one photo cannot yet be shown to meet $\pm$5%; the image quality that matters is reliability across re-shoots. Generic no-reference quality scores chosen before labeling do not rank PG-Lattice's error, and generative enhancement raises perceptual scores but does not reliably improve the count.

0.35
11

Data Archive for 2D and 3D Electrical Impedance Tomography with moderate conductivity contrast phantoms

eess.IV cs.LG ·2026-11-12 ·S. J. Hamilton, A. Hauptmann, A. Hänninen, V. Kolehmainen, J. Niskanen +2 more
code/data
Abstract · 11 pages, 6 figures. Data available at https://doi.org/10.5281/zenodo.24120439

This document describes open Electrical Impedance Tomography (EIT) measurement data that were collected from biomedical imaging inspired phantoms with moderate conductivity contrasts. The data were collected with the KIT4 and KIT5 EIT measurement devices at the University of Eastern Finland, and are intended for EIT image reconstruction algorithm development and testing. The data from thoracic imaging inspired cylindrical and chest-shaped phantoms are suitable for 2D algorithms, and the data from an intracerebral hemorrhage imaging inspired head-shaped phantom with resistive skull are suitable for 3D algorithms. In addition to the measurement data, computational meshes and example reconstruction codes are provided and sample reconstructions included.

0.34
12

Artifact Filtering versus Artifact-Compensated Training in JPEG to JPEG AI Recompression

eess.IV cs.MM ·2026-11-09 ·Igor Podtsepko, Yuriy Kim, Karam Mahfod, Evgeny Belyaev, Kristian Kirs +2 more
Abstract · Preprint. Submitted to IEEE Multimedia on 21 February 2026. This is the author's draft version; it has not undergone peer review. 15 pages, …

In this paper, we consider the problem of recompression of images from JPEG to JPEG AI format. We show that direct recompression from JPEG to JPEG~AI trained on uncompressed images is accompanied by the preservation of the JPEG image artifacts in the resulting JPEG~AI image. In order to avoid it, we evaluate an approach where an artifacts removal neural network is first applied to the input JPEG image as an external pre-filter. However, in this case, the processing time is increased by 29 times. Therefore, we propose an artifact-compensated training for JPEG AI and show that it is able to combine pre-filtering against target distortions with efficient compression without increase in the processing time.

0.33
13

Aggregate Accuracy Hides Diagnosis-Specific Failure in Medical Vision-Language Models

eess.IV cs.CLcs.CVcs.LG ·2026-11-11 ·Shreya Ajay Kale, Angad Ripudaman Singh Bajwa
published
Abstract · Accepted at the NeurIPS 2026 Workshop on Medical Reasoning with Vision Language Foundation Models (Med-Reasoner). 16 pages including NeurIPS…

Medical vision-language models (VLMs) are compared mainly by accuracy averaged across findings, a summary that can hide complete failure on a single diagnosis. We audit five open medical VLMs (MedGemma-4B, Lingshu-7B, HuatuoGPT-Vision-7B, Qwen2.5-VL-7B, and MedVLM-R1) on 6,048 ChestX-ray14 questions balanced by sex, age, finding, and label. On the 432 pneumothorax-positive X-rays, HuatuoGPT-Vision and Qwen2.5-VL detect zero cases while MedGemma and Lingshu detect 38% and 67% of the same images. The two failing models answer "no" to all 864 pneumothorax cases (balanced accuracy 0.500, chance), yet produce fluent, anatomically specific explanations that name the signs of a collapsed lung and then deny them, with no hedge or abstention. This failure is not an artifact of prompting, image resolution, label ambiguity, or model scale. It persists across four prompt formats, at native resolution, and on single-label cases. A within-model control shows the same forced prompt gives HuatuoGPT 79% recall on nodule but only 6% on pneumothorax. It survives a tenfold scale increase (Qwen2.5-VL-72B detects 4%) and replicates on SIIM-ACR, an independent dataset with radiologist-drawn masks, where the failing models detect 0 of 432 confirmed pneumothoraces, including 0 of the 144 largest lesions. Reading the models' logits and internal states shows this is not blindness. The two failing models are highly confident yet no better than chance and a linear probe recovers pneumothorax from their hidden representations even where recall is zero, so the finding is represented internally but suppressed at the output. Aggregate accuracy therefore cannot establish that a medical VLM can see a given finding, because a model that misses one can still describe it convincingly. Reporting per-finding recall and specificity on balanced cases is needed to tell the difference.

0.33
14

Automated PD-L1 Tumor Proportion Scoring with Uncertainty-Guided Triage in Non-Small Cell Lung Cancer

cs.CV eess.IV ·2026-11-12 ·Kesi Xu, Ayesha Azam, Tanvier Kaur, Monika Kondratowicz, Kinza Asim +5 more
hot direction
Abstract · 55 pages (29-page main text with 5 figures and 3 tables, followed by 26 pages of supplementary material)

Programmed death-ligand 1 (PD-L1) tumor proportion score (TPS) informs immunotherapy selection in non-small cell lung cancer. Near the 1% and 50% cutoffs, the score should also indicate when closer review is warranted. We designed a three-stage framework to follow the sequence of TPS assessment. Stage 1 identifies tumor regions and excludes macrophage-rich patches. Stage 2, a dual-branch cell counting network (D2Count-Net), counts PD-L1-positive and PD-L1-negative tumor cells in these regions to calculate TPS. Stage 3, TPS-Guard, an uncertainty-guided triage mechanism, reports model uncertainty as the disagreement among independently trained models, refers the most uncertain slides, and flags scores near the 1% or 50% cutoff when model estimates disagree across that cutoff. Flags state the reason for referral or alert the pathologist to possible scoring errors on auto-reported slides. In a retrospective, single-center study, 154 whole-slide images were scored by three pathologists, and the model and each pathologist were compared in turn with the mean of the other two. On the 114 slides unseen in training, model mean absolute error (MAE) was 6.96 percentage points, within the range of the three pathologists (4.24 to 8.29), and model uncertainty correlated with absolute TPS error (Spearman rho = 0.77) and inter-pathologist disagreement (rho = 0.71). After referral of the 15% most uncertain slides, model and pathologist MAE both decreased. Applied without retraining to an external, publicly available dataset, TPS-Guard still directed review to higher-error cases, and referring more uncertain cases raised sensitivity at the 50% cutoff. TPS-Guard provides reasons for reviewing individual automated scores and identifies slides that also produce greater disagreement among pathologists. Prospective reader studies should assess TPS-Guard's effect on TPS reporting.

0.31
15

Few-Shot Open-Set Hyperspectral Pixel-Wise Classification with Spatial Aware Label Propagation

eess.IV cs.NE ·2026-11-13 ·Matheus Pereira, Jefersson Santos, Laurent Najman
publishedbenchmarkhot direction
Abstract

Pixelwise classification of hyperspectral images (HSI) is a fundamental task in remote sensing, but its deployment in real-world applications is often limited by the scarcity of labeled data and the presence of unknown classes at inference time. In this work, we propose Few-shot Open-set hyperspectral recognition from Self-Supervised Learning training (FOSSeL), a unified framework for few-shot, open-set hyperspectral pixelwise classification that does not require supervised training. The proposed approach first leverages self-supervised learning to construct a discriminative feature space from unlabeled data. Then, given a small set of labeled seed pixels, class predictions are obtained through spatially-aware graph-based label propagation over superpixel representations, enabling the joint exploitation of spectral similarity and spatial consistency. To address the open-set scenario, we introduce simple yet effective strategies to identify pixels that do not belong to the known classes. We evaluate FOSSeL on three benchmark hyperspectral datasets under multiple few-shot settings. The results show that the proposed framework achieves competitive or superior performance compared to fully supervised methods while maintaining robustness in the presence of unknown classes. These findings highlight the potential of combining self-supervised feature learning with graph-based inference for practical HSI analysis in low-annotation and open-world scenarios.

0.31
16

Streaming across viewing conditions - The effect of viewing distance and display luminance on video quality

eess.IV cs.CVcs.MM ·2026-11-15 ·Dounia Hammou, Lukáš Krasula, Christos G. Bampis, Zhi Li, Rafał K. Mantiuk
unusual
Abstract

The visibility of streamed video distortions is affected by the user's display and viewing conditions, such as their display's luminance or the viewing distance. Distortions become less visible at lower luminance levels or farther viewing distances. However, most image and video quality metrics assume fixed optimal display and viewing conditions, making them insensitive to the viewing conditions. In this work, we demonstrate how existing metrics can be adapted to account for both factors and compare such an adaptation with the metrics that natively model viewing conditions. First, we collected a new video quality dataset, HDR-VDC, which contains streaming distortions in 4K HDR videos. The dataset consists of 12 4K and 4 FHD HDR source video content, each distorted with AV1 encoding and Lanczos upscaling from a lower resolution. The quality loss due to the distortions was measured at two viewing distances, corresponding to 60 and 120 pixels per visual degree, and two display mean luminance levels, varying by a factor of 8 in terms of luminance. Next, we developed a pre-processing framework that lets us adapt many quality metrics so that they can evaluate content across the viewing distances and luminance levels. The framework employs a display model and perceptually uniform encoding, PU21, to account for the effect of display luminance, and perspective projection scaling (PPS) to account for the effect of viewing distance. We used the framework to compare the performance of 35 state-of-the-art metrics. This allowed us to identify a selection of existing quality metrics that can be effectively adapted to account for the viewing conditions.

0.31
17

A four-step validation protocol for radiomic survival analysis in small cohorts: a body composition case study

eess.IV cs.CVcs.LG ·2026-11-09 ·Mariela Talavera-Muñoz, Cecilia Diana-Albelda, Miguel Antonio Sampedro-Nuñez, Victor Rodriguez-Laval, Jesus Bescos +1 more
code/data
Abstract

Gastroenteropancreatic neuroendocrine tumors (GEP-NET) lack prognostic biomarkers, and computed tomography (CT)-based body composition radiomics at the third lumbar vertebra (L3) is a promising candidate. Small cohorts make high-dimensional radiomic models prone to overfitting and single-split evaluations variable and optimistic. This methodological study proposes a four-step validation protocol for radiomic survival analysis in small cohorts: (1) false discovery rate (FDR)-corrected feature selection, (2) a dual-path comparison of prior feature selection versus embedded regularization, (3) repeated nested cross-validation (CV) and (4) a negative control with Gaussian noise features. In 78 GEP-NET patients, 535 radiomic features from five L3 compartments were used to evaluate five survival models with Harrell's concordance index (C-index), time-dependent area under the curve (AUC) and integrated Brier score (IBS). Step 1 selected at least one feature in 18% of outer folds under noise (nominal level 20%) versus 84% with radiomic features. The dual-path comparison showed no consistent difference between strategies. Repeated nested CV reduced variability across seeds (41% median reduction in C-index standard deviation), but not enough to distinguish models. The nested CV C-index exceeded chance by 0.07-0.15 with radiomic features but not clearly under noise (0.40-0.42 with prior feature selection, 0.47-0.55 with embedded regularization). Frequently selected features tentatively linked greater subcutaneous fat, skeletal muscle compactness and texture to better prognosis. These findings suggest a modest prognostic signal in L3 radiomics, with considerable uncertainty that the protocol quantifies. The protocol may transfer to other small-cohort radiomic survival studies. Code: https://github.com/marielatalaveram/radiomics-survival-validation-protocol.

0.30
18

Equal Dose, Different Coverage:Tracing Rate and Duration in Image Editing

eess.IV cs.AIcs.MM ·2026-11-15 ·Yi Liu
Abstract

Benchmarks for scientific image editing test whether a model draws the outcome of a described process, leaving open which representations carry its errors and whether correcting them yields the right quantity. We study this question with an airbrush of fixed deposition profile, under which exchanging rate and duration preserves the dose and should preserve the endpoint, yet changes the edited coverage. Matched-norm activation patches across text positions and denoising stages show that, in distilled FLUX with Chinese prompts, representations at unchanged text positions (context) carry this discrepancy: early context transfers 3.51 of the 3.98 percentage-point (pp) signed route difference, against 0.09 pp for equal-norm updates at the two changed digits. Early image latents transmit native (unpatched) route differences across two FLUX configurations and OmniGen, while text-position effects depend on configuration. The trace predicts an intervention: share early context between routes while each retains its own digits. On independent English layouts, this reduces the distilled-FLUX absolute route gap from 1.13 to 0.60 pp, outperforms early digit sharing, and improves agreement more than in base FLUX under directly paired tests. Calibrated evaluation, which prescribes an area for each dose, separates this gain from accuracy: sharing the full prompt encoding produces identical route images with target errors of 8-16 pp, and stating the target percentage directly retains a compressed area response. Localization predicts a consistency gain on new layouts, and calibration measures the quantity error that agreement leaves unresolved.

0.29
19

Probing Where Surprise Happens: Localized Violation-of-Expectation Evaluation of Video World Models

cs.CV cs.AIeess.IV ·2026-11-13 ·Yanbin Xu, Ming bo Cai
published
Abstract · 8 pages, 4 figures

Violation-of-expectation (VOE) benchmarks evaluate intuitive physics in video world models by testing whether physically impossible events produce greater prediction errors than matched possible events. However, conventional VOE evaluations aggregate prediction errors across space and time, making it unclear whether successful discrimination reflects model's understanding of physical violations at the locations and time where they occur. To address this limitation, we introduce localized VOE evaluation, a framework that measures prediction error differences between possible and impossible events within spatial regions and temporal intervals associated with physical violations. We compare global, temporally localized, and spatiotemporally localized evaluations of V-JEPA models pretrained on developmental egocentric videos or large-scale natural video datasets. Our results reveal that global and localized judgments can diverge in both directions: global aggregation can either obscure correct localized discrimination or produce apparent discrimination without corresponding localized evidence. During continued pretraining on developmental egocentric videos, agreement between global and localized judgments changes non-monotonically, while confidence in localized judgments increases despite modest improvements in accuracy. Together, these findings establish localized VOE evaluation as a complementary diagnostic for assessing intuitive physics in video world models and demonstrate that global prediction errors do not necessarily reflect the spatiotemporal evidence of physical violations.

0.27
20

Sequential Semantic-Non-Semantic Watermarking: Robustness Against UnMarker Attacks

cs.CR cs.CVcs.MMeess.IV ·2026-11-15 ·Md Ifraham Iqbal
Abstract · 13 pages, 16 figures. Preprint based on M.Sc. thesis research

Advancements in artificial intelligence (AI) have accelerated digital content generation and intensified concerns around fraud, misuse, counterfeiting, and content provenance. Defensive image watermarking provides a practical mechanism for identifying and tracing digital content, but recent watermark-removal attacks challenge its robustness. This study investigates Sequential Semantic Non-Semantic Watermarking (SSNSW), which combines HiDDeN and StegaStamp as complementary non-semantic and semantic watermarking schemes. Using 50 images from MS-COCO and CelebA-HQ, both embedding orders are evaluated, followed by UnMarker's non-semantic and semantic attacks applied individually and sequentially. Results show that both watermarks remain highly decodable after dual embedding, with only limited embedding-order effects. Under individual attacks, one watermark generally remains strongly decodable: StegaStamp under the non-semantic attack and HiDDeN under the semantic attack. Sequential attacks are therefore required to substantially reduce both watermark signals, while attack order has a limited and configuration-dependent effect. The semantic attack also shows a broader effect across the two watermark types than the non-semantic attack. LPIPS remains relatively low in several settings, although qualitative inspection reveals noticeable distortions, particularly in selected facial images, indicating that LPIPS should not be used alone to assess visual quality. Overall, the findings show that combining complementary watermark types can increase robustness against single-stage removal attacks and motivate broader multi-layer watermarking, stronger perceptual evaluation, and further study of sequential watermark-removal strategies.

0.27