CS Paper Radar

Weekly top 10 · eess.SY

2026-W36 Aug 31 – Sep 06, 2026

Ranked from 4,110 papers submitted on 7 days.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works
1

Blackbox Small-Signal Modeling of Grid-Connected Inverters in Asymmetrical Power Grids

eess.SY ·2026-09-01 ·Airan Frances, Dionisio Ramirez, Javier Uceda
top venuehighly cited
Abstract · 11 pages, 14 figures, IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 38, NO. 10, OCTOBER 2023

Power electronic converters are envisaged to be key enablers of modern electric power distribution systems. Grid-connected three-phase inverters are widely used in Smart Grids and microgrids, but also in standard grids. They provide controllability and dynamic decoupling capabilities, which are fundamental in the integration of renewable sources and storage systems and in specialized applications such as FACTS. Nevertheless, power electronics-based systems can exhibit dynamic interactions, which may lead to power quality issues. Although the electrical model of each element of these systems is important for their system-level analysis, they are rarely available. Blackbox modeling strategies are useful for obtaining behavioral models of commercial electronic converters. Most blackbox modeling strategies are focused on dc-dc electronic converters; however, some works have extended these concepts to three-phase converters by means of the dq framework, under the assumption of symmetrical and balanced conditions. This work proposes a new structure in the sequence domain to represent the dynamic behavior of grid-connected commercial converters in asymmetrical conditions. Experimental tests have been performed on a three-phase inverter to identify its blackbox model and its performance has been validated during an asymmetric voltage sag.

0.82
2

Leveraging Time-Causal State Variable Aggregation for Real-Time Schedule of Massive Air Conditioners

eess.SY ·2026-09-02 ·Jingguan Liu, Xiaomeng Ai, Shichang Cui, Xizhen Xue, Shengshi Wang +3 more
top venuehighly cited
Abstract · Published in: IEEE Transactions on Smart Grid (vol. 16, no. 3, pp. 2389-2403, 2025)

Air conditioner (AC) loads offer promising flexibility for active distribution networks to manage uncertainties, such as those in renewable energy generation, electricity prices, and load demand. However, real-time scheduling of ACs is challenging due to their massive temporal coupling constraints and time-causal uncertainties. To address this, a novel time-causal aggregation-based approximate dynamic programming (TCA-ADP) algorithm is proposed for efficient scheduling. The time-causality requirements for aggregating state variables are first analyzed to align with the real-time sequential decision-making process. Subsequently, an enhanced aggregation model is developed to ensure both high accuracy and adherence to time causality. The aggregation process is further reformulated as a linear program to optimize aggregation parameters and enable tractable computation. Accordingly, the TCA-ADP leverages aggregated state variables to approximate the value function as a new way, balancing computational efficiency and economy against the large value function space of massive ACs. By training the value function offline using historical data, the TCA-ADP efficiently achieves near-optimal real-time scheduling of massive ACs through parallel and closed-form disaggregation. Case studies demonstrate the effectiveness and scalability of the TCA-ADP, highlighting its aggregation accuracy, uncertainty handling, and the trade-off between economy and tractability.

0.74
3

Situation Awareness for Intelligent Data Distribution in Connected Vehicles

cs.RO cs.AIcs.CVcs.NI+1 ·2026-09-01 ·Falk Dettinger, Akshay Narla, Michael Weyrich
publishedcode/datahot direction
Abstract · Peer-reviewed and Published in the 2025 IEEE 101st Vehicular Technology Conference (VTC2025-Spring)

The limitations of on-board sensors and blind spots caused by occlusion cause the reduction of perception quality in autonomous vehicles. In such cases, cooperative perception provides additional data via Vehicle-to-Everything communication to enhance local perception, causing a large volume of data transmission. The vehicle can focus on acquiring and utilizing relevant data according to the prevailing road context by identifying the current traffic situation. To achieve this, we propose a concept for the situation identification of the vehicle using Bird's-Eye-View images. Firstly, the situation around the vehicle is identified using object detection with semantic segmentation, followed by understanding the context of the traffic using a situation identification module consisting of an open-source projective transformation network Cam2BEV and a situation identification neural network. The concept was evaluated and validated by running the software on the CARLA simulator using the in-built RGB camera and the semantic segmentation camera. Additionally, the portability of the situation identification module for real-world applications was verified on Cityscapes and nuScenes urban driving datasets. Overall, the proposed situation identification approach enables efficient sensor data management by prioritizing relevant data to the current traffic situation. The source code is available in the following link: https://github.com/akshaynarla/DySi_Select

0.72
4

Equivalent DQ Sequence-Domain Model of Unbalanced Three-Phase Passive Elements for Power Converter Controllers

eess.SY ·2026-09-01 ·Air\án Franc\és, Luis Saz, Rafael Castillo, Dionisio Ramirez, Javier Uceda
publishedtheory
Abstract · 8 pages, 7 figures, 2023 IEEE Applied Power Electronics Conference and Exposition (APEC)

Equivalent dq0 models of three-phase passive impedances are widely used for the design of three-phase inverter and rectifier controllers in the synchronous frame. However, these equivalent models assume that the impedance in each phase are the same, which is not always applicable. The fact that the impedance in each phase is different, generates second order harmonic content in the dq0 components, which hinders the advantages of the dq0 transformation. To avoid the second harmonic in these scenarios, it is possible to use the Fortescue's theorem to represent any asymmetrical set of three-phase signals as a linear combination of three symmetrical sequences. In the literature, only a few works have attempted to derive the equivalent model of unbalanced three-phase passive elements in the sequence domain, and none is able to account for the interaction between the zero sequence and the positive and negative sequences. This work presents the derivation of the equivalent dq sequence-domain model of unbalanced three-phase passive elements both analytically and with an intuitive graphical approach. Experimental results are shown to validate the proposed models.

0.72
5

Continuous-Time Aggregation of Massive Flexible HVAC Loads Considering Uncertainty for Reserve Provision in Power System Dispatch

eess.SY ·2026-09-02 ·Jingguan Liu, Xiaomeng Ai, Jiakun Fang, Shichang Cui, Shengshi Wang +2 more
top venuehot directionhighly cited
Abstract · Published in: IEEE Transactions on Smart Grid (vol. 15, no. 5, pp. 4835-4849, 2024)

Heating, ventilation, and air conditioning (HVAC) loads, with their rapid response capabilities, can provide considerable intra-hour flexibility on the demand side for reserve provision in order to follow the fast variations of renewables. However, scheduling massive HVACs is challenging due to computation complexity and the uncertainty of outdoor temperature. In this paper, we first introduce a novel continuous-time (CT) aggregation model to reveal the potential intra-hour flexibility of HVACs. For accurate aggregation, a new affine transformation is designed to handle the heterogeneity in high-dimensional feasible region. Further, for reliable aggregation in practical environment, the outdoor temperature uncertainty is constructed by distributionally robust chance constrains and integrated into the aggregation model. Secondly, for the tractable calculation of the proposed CT aggregation model, a cascade of tailored reformulation techniques is proposed, including the Bernstein polynomial spline, polytope projection, and linearization transformation. Thirdly, a customized hierarchical dispatch framework is proposed via incorporating the proposed CT aggregation model into reserve provision in power system dispatch, so as to efficiently schedule massive HVACs to cope with the renewable uncertainty. Case studies verify the effectiveness and scalability of the proposed CT aggregation model in aggregation accuracy, intra-hour flexibility utilization, and uncertainty handling.

0.67
6

Full-field laser-Doppler-vibrometry FRF dataset for a four-bolt aluminum plate under bolt-torque variation

eess.SP eess.SY ·2026-09-04 ·Berkay Kullukcu, Dina Hannebauer
publishedunusual
Abstract

The dataset described in this article was constructed using the results of laser Doppler vibrometry experiments conducted on an aluminum plate having four bolts. The database captures the variation in the vibration characteristics of the plate as a function of changes in tightening torque on the bolts. In total, there were 18 different states for the tightening torque, ranging from a situation where all bolts are tightened to all bolts being loose. Other possible combinations include states with varying torque applied to just one bolt, and those involving multiple loose bolts. Data consist of 1,836 files exported from Polytec PSV-500, categorized as amplitude and phase data, for frequency ranges spanning 1 Hz to 51,200 Hz at intervals of 1 Hz. The identified zones were analyzed at 51 scan points for all states of torque. Supporting documents included specifications of the test plate, scan point and torque state information, selected resonance peaks tables, measured frequencies for seven resonance groups, correlation values for all FRF, visualizations, and code scripts.

0.66
7

Large Language Models for HVAC Operations in Building Energy Systems: A Critical Review of Methods, Applications, and Deployment Readiness

cs.AI cs.CLeess.SY ·2026-09-04 ·Alexander Neubauer, Tianzhen Hong, Han Li, Mengbo Yu, Amin Darbandi +2 more
survey
Abstract · 38 pages, 9 figures, 16 tables. Submitted to Energy and Buildings

Building automation systems generate rich sensor data yet remain insight-poor because heterogeneous point naming, missing metadata, and fragmented documentation obstruct their operational use. This systematic review analyses and codes 66 peer-reviewed studies on large language models (LLMs) for HVAC operations published between 2023 and March 2026. Each study is classified across five application families and three LLM method families and assessed for evidence realism, deployment readiness, and the responsibility boundary between the LLM and physical HVAC decisions. The corpus is concentrated in building energy modelling (BEM, 32 of 66 papers), while load forecasting remains too sparse for subfield-level conclusions. Only four studies reach pilot-level evidence, and none reports sustained operational deployment. No study was classified as ready-now for industry adoption; three were near-term and 63 research-only. Nevertheless, several bounded, human-in-the-loop uses merit near-term trials, including point-name normalisation, document-grounded operator support, BEM workflow assistance, and advisory interfaces around physics-based controllers. Conventional machine learning (ML), model predictive control (MPC), reinforcement learning (RL) and ontology-based tools remain more adopted for high-frequency control, short-horizon numerical forecasting, and well-posed ontology mapping, while autonomous agentic operation and unvalidated occupant proxies remain research-stage. Current evidence therefore supports LLMs primarily as semantic and workflow layers rather than autonomous HVAC controllers. Future work should prioritise field-validated benchmarks, orchestration evaluation under operational constraints, and LLM-MPC/RL architectures with bounded latency and verifiable safety properties.

0.64
8

Tests on the POD-P controller of INELFE Spain-France VSC-HVDC interconnector

eess.SY ·2026-09-02 ·Javier Renedo, Agustín Diaz-García, Gilles Torresan, Eduardo Lorenzo Cabrera, Antonio Cordón +9 more
unusual
Abstract

INELFE interconnector consists of a 2x1000 MW high voltage direct current system based on voltage source converters (VSC-HVDC) interconnecting France and Spain. INELFE VSC-HVDC link is embedded into the high voltage alternating current (HVAC) system. Electromechanical oscillations, also known as power oscillations, are a major concern worldwide. INELFE VSC-HVDC link has specific controllers to damp power oscillations by modulating active (P)- and reactive (Q)-power injections of the VSC converters (POD-P and POD-Q controllers, respectively). The Spanish and French Transmission System Operators (TSOs) carried out a join task force to - Increase the gain of POD-P controller of INELFE VSC-HVDC link. - Make it possible to use the POD-P controller together with angle difference control (ADC) of INELFE VSC-HVDC interconnector. The objective of these modifications is to improve the effectiveness of POD-P controller and, therefore, to increase its contribution to the damping of inter-area oscillations in the Continental Europe (CE) power system. Such changes require (a) extensive simulation studies and (b) extensive tests in different operation modes, in order to ensure the correct behavior of the system. This paper presents simulation studies and field tests on the POD-P controller of INELFE VSC-HVDC interconnector in different modes of operation.

0.62
9

Coupling-Aware Aggregation of Multi-Zone HVAC Loads under Uncertainty: A Two-level Framework

eess.SY ·2026-09-03 ·Jingguan Liu, Han Jiang, Xiaomeng Ai, Shengshi Wang, Xizhen Xue +4 more
top venuehighly cited
Abstract · Published in: IEEE Transactions on Smart Grid (vol. 17, no. 3, pp. 2077-2091, 2026)

Aggregating building heating, ventilation, and air-conditioning (HVAC) loads unlocks substantial demand-side flexibility for power systems. Yet multi-zone coupling creates intricate interdependencies and uncertainty propagation, complicating the quantification of aggregate flexibility. To address this issue, this paper proposes a coupling-aware two-level aggregation framework. At the building level, tailored Gaussian elimination and coordinate transformation techniques are employed to recast the high-dimensional thermal dynamics as an equivalent lower-dimensional analytical expression. This expression streamlines the subsequent aggregator-level stage by (i) clarifying the propagation of zone-level uncertainties to the building-level interface, (ii) decoupling intra-building multi-zone coupling from inter-building aggregation, and (iii) providing full-dimensional building-level flexibility sets that enable tractable reformulation. At the aggregator level, existing geometric aggregation approaches are generalized by a newly developed matrix-transformation technique. This technique effectively constructs inner approximations between polytopes of different dimensions, producing closed-form images of high-dimensional multi-zone HVAC flexibility in power subspace. The resulting inner approximation is then recast as a customized separatable linear program that efficiently determines the optimal aggregate parameters. Case studies validate the effectiveness of our framework, highlighting its accuracy, reliability, and scalability.

0.60
10

Stability of Droop-Controlled Low-Frequency Transmission Lines

eess.SY ·2026-09-01 ·Rafael Castillo-Sierra, Giri Venkataramanan, Dionisio Ramirez
published
Abstract · 6 pages, 3 figures, 2023 IEEE Energy Conversion Congress and Exposition (ECCE)

Low-Frequency AC (LFAC) transmission systems employing power converters are being considered for a varity of applications. This work studies the small-signal stability of an LFAC transmission line controlled by the Droop Control Strategy. Eigenvalue Analysis is used to determine how the controller droop gains, operating frequency, transmission line parameters, and the operating point affect system stability. The results show that the overall system's dynamic is governed by the sum of the droop gains of the AC/AC converters. Analytical results that give insights on how the different system's parameters affect the critical stability point are presented. The results indicate that system stability is affected by the line's length, the line's R/X ratio, operating frequency and voltage.

0.56