CS Paper Radar

In Defense of OCTA: The Reconstruction-Utility Gap in OCT-to-OCTA Synthesis

Michael Chertok, Alon Tiosano, Orly Gal-Or, Lior Kramarski, Einav Baharav Shlezinger, Irit Bahar, Lior Wolf

cs.LG ·submitted 2026-08-16 08:45 UTC · v1
published

Abstract

Optical coherence tomography angiography (OCTA) images retinal blood flow, giving capillary-perfusion and foveal-avascular-zone biomarkers that grade diabetic-retinopathy ischemia. Because OCTA hardware is less common than structural OCT, recent work synthesizes it from OCT, reporting strong reconstruction (3D PSNR > 31 dB, SSIM > 0.9). We ask not whether the synthetic image looks similar, but whether it supports the measurements OCTA is acquired for. A frozen real-OCTA segmenter, applied as a probe to two synthesizers (XOCT, TransPro), shows downstream Dice falling with structural fineness: large vessels survive (0.862 -> 0.831) while the fine capillary network collapses (0.798 -> 0.635, five times the large-vessel loss; paired Wilcoxon p < 1e-3), TransPro worse throughout. A matched-blur control shows this detail is fabricated, not blurred. Retrained on a private Spectralis dataset, neither synthesizer reproduces the neovascular lesion (qualitative, n=3). Reconstruction fidelity is not clinical utility; we establish downstream-task fidelity as the evaluation OCT-to-OCTA synthesis needs.

Comment
10 pages, 2 figures, 3 tables. Accepted at OMIA 2026 (13th Ophthalmic Medical Image Analysis Workshop, MICCAI 2026). This is the pre-peer-review submitted version; the camera-ready revises the characterization of the capillary failure

Closest papers

Nearest neighbours by meaning across the whole index.

An Ultra-Widefield Swept-Source OCTA Dataset and a Polar-Gated Mamba Network for Retinal Vessel Segmentation

cs.CV ·2026-09-11 ·Yang Liu, Yibing Shen, Keming Zhao, Cenk Jiang, Zhenghang Qian +10 more
code/data similarity 0.58
Abstract · Submitted to IEEE Journal of Biomedical and Health Informatics. Under review

Ultra-widefield (UWF) swept-source optical coherence tomography angiography (SS-OCTA) enables large-area retinal vascular imaging, yet vessel segmentation at this scale lacks dedicated public benchmarks and comprehensive evaluation for quantitative vascular analysis. We introduce WOIVES, to our knowledge the first publicly available UWF SS-OCTA vessel-segmentation dataset, comprising 206 eyes from 152 participants with a 24x20mm^2 field of view. WOIVES spans emmetropia to high myopia and provides soft probability vessel annotations. We further propose PG-Mamba, a visual state space model that enhances conventional directional scans with two complementary polar-coordinate scan orders. An auxiliary Dynamic FOV Gating module performs spatial modulation at the bottleneck. PG-Mamba outperformed seven competitive approaches on broad segmentation metrics under cross-validation. It achieved the lowest median absolute errors for vessel density, fractal dimension, and vessel length density. WOIVES is publicly available on Zenodo (DOI: 10.5281/zenodo.21904672), and the PG-Mamba code is available at https://github.com/syb1234567/PG-Mamba.

0.36

RBA: A Read-out Basis Adapter for Parameter-Efficient Interactive OCTA Vessel Segmentation with SEEM

cs.CV cs.LG ·2026-11-09 ·Jaafar M. Al-Ghabban, Mohammad Reza Mohammadi
similarity 0.58
Abstract

Retinal disease monitoring with optical coherence tomography angiography (OCTA) relies on segmentation of vessels and the foveal avascular zone (FAZ). Promptable models such as SEEM (Segment Everything Everywhere All at Once) allow click-based refinement, but without adaptation SEEM segments thin vessels poorly and needs many clicks. Fully fine-tuning its 342 million parameters on a few hundred images is costly and risks overfitting, and parameter-efficient methods such as low-rank adaptation (LoRA) usually adapt only the encoder. Yet SEEM reads every candidate mask from one feature map at quarter resolution, too coarse for vessels one to three pixels wide. This study introduces the Read-out Basis Adapter (RBA), whose read-out branch generates 32 image-specific basis maps at half resolution. Each candidate accesses them through its own vector and a zero-initialised projection, so the model starts exactly as SEEM. The encoder branch, a standard rank-1 LoRA, supplies the information needed to tell arteries from veins. RBA adds 0.47 million trainable parameters. Under simulated error-driven clicks, with the ground truth used only to place them, RBA outperforms LoRA, Conv-LoRA andAdaptFormer on OCTA-500 3mmlarge vessels. Averaged over three seeds, it reaches an intersection over union (IoU) of 85.16% and a Dice score of 91.93%, 2.90 and 1.72 percentage points above Conv-LoRA. On the 6 mm subset, one run gives margins of 4.35 and 2.76 points. The gain extends to arteries, veins and ROSE-O but not to the FAZ. In SEEM, adaptation capacity pays more at the mask read-out than in the encoder.

0.25

CNN-Based Retinal OCT Classification: Research Gap Analysis and a From-Scratch Baseline, ED126-A

cs.CV cs.LG ·2026-11-01 ·Shkelqim Sherifi
benchmark similarity 0.56
Abstract · 18 pages, 26 figures

Automated classification of retinal pathologies from Optical Coherence Tomography (OCT) images remains challenging because diagnostically relevant morphological patterns may exhibit substantial inter-class similarity. Although high classification accuracies have been reported on benchmark OCT datasets, cross-study comparison is limited by heterogeneous evaluation protocols and by the limited characterization of compact convolutional neural network (CNN) baselines trained from random initialization. This study addresses this gap through two contributions. First, it provides a focused review of CNN-based retinal OCT classification and identifies methodological considerations relevant to controlled benchmarking. Second, it presents ED126-A, a purpose-built four-class CNN baseline trained from scratch under a documented experimental protocol on the Kermany labeled OCT dataset. The model contains 1,241,380 total parameters, including 1,239,460 trainable parameters, and is evaluated using training-dynamics analysis, class-wise performance metrics, confusion-matrix analysis, confidence analysis, t-SNE representation-space visualization, Grad-CAM, hierarchical feature-map analysis, and one-vs-rest ROC/Precision-Recall analysis. On the image-level held-out test set, ED126-A achieved 95.03% accuracy, with a macro-F1 of 0.9205 and a weighted-F1 of 0.9521. The principal class-conditional limitation occurred for Drusen, which attained a recall of 0.9605 but a precision of 0.7493 and an F1-score of 0.8419. The confusion matrix identified Normal to Drusen and CNV to Drusen as major error channels. These results support the use of ED126-A as a documented from-scratch reference baseline and provide an empirical basis for controlled evaluation of transfer learning, increased depth, attention, multi-scale feature fusion, and calibration in subsequent studies.

0.30

Automated 2D and 3D Segmentation of AMD and DME Lesions in OCT

cs.CV ·2026-08-27 ·Lucia Sundberg, Zhihao Zhao, M. Ali Nasseri
similarity 0.55
Abstract

Age-related macular degeneration (AMD) and diabetic macular edema (DME) are leading causes of vision loss, and optical coherence tomography (OCT) is the standard modality for detecting and monitoring the subtle lesions that drive treatment decisions. Most deep-learning segmentation work for OCT is validated only in-domain, leaving generalization to clinical data collected under different acquisition protocols largely untested. This work develops and systematically ablates four lesion-segmentation pipelines -- 2D and 3D variants for AMD and DME -- reaching Dice scores of 0.76 to 0.82 with strong volumetric and surface calibration (r vol, r surf greater than or equal to 0.97 across all four pipelines) on an in-domain validation set. The ablation process establishes a full-volume, calibration-aware adoption standard that catches mechanisms an ordinary slice-level evaluation would keep, and identifies ensemble composition as the most consistent driver of improvement. To test generalization, the models are evaluated on OLIVES, an external clinical cohort with no lesion-level ground truth, using a proxy-metric framework built around biomarker AUROC, central subfield thickness (CST) correlation, and longitudinal concordance. Predictions track clinical biomarkers outside the training distribution, though less strongly than in-domain -- evidence for, not validation of, automated lesion-burden tracking as a clinical tool.

0.25

Retinal OCTA Phenotyping with LLM Reporting for Alzheimer's Disease

cs.CV cs.CL ·2026-09-04 ·Progga Paromita Dutta, Jeba Maliha, Md Rafiul Kabir
top venue similarity 0.54
Abstract · 4th IEE International Conference on Artificial Intelligence, Blockchain, and Internet of Things, (AIBThings)

Early identification of Alzheimer's disease (AD) remains challenging because established assessment methods can be costly, resource-intensive, or unsuitable for population-scale screening. Optical coherence tomography angiography (OCTA) provides non-invasive visualization of retinal microvasculature, but existing approaches often require diagnostic labels and provide limited measurement-level interpretation. We present an explainable OCTA pipeline that integrates annotation-aware vessel segmentation, layer-specific vascular biomarker extraction, label-free phenotyping, and measurement-grounded LLM reporting. Using 117 ROSE-1 images from 39 subjects, we apply annotation-matched segmentation models to superficial vascular complex (SVC), deep vascular complex (DVC), and combined SVC+DVC representations. The models achieve ROC-AUC values of 0.916-0.970 and Dice scores of 0.695-0.781. Six density and fractal-dimension biomarkers form subject-level profiles for exploratory clustering. Analysis of nine held-out subjects identifies an internally consistent lower-density, lower-fractal-dimension phenotype, although the absence of diagnostic labels prevents clinical interpretation. Reports generated using GPT, Gemini, and Llama are evaluated for measurement grounding, citation faithfulness, and diagnostic caution. Overall, the framework provides a transparent, non-diagnostic connection between retinal vascular measurements, exploratory phenotyping, and evidence-linked interpretation for Alzheimer's research.

0.31

Perturbation-Based Reconstruction of Depth-Resolved OCT Attenuation without Requiring a Fully Decayed Signal Tail

eess.IV physics.optics ·2026-11-04 ·Jinglun Yu, Yaning Wang, Shuwen Wei, Jin U. Kang
unusual similarity 0.54
Abstract · 26 pages, 10 figures, including 1 supplementary figure. Submitted to Biomedical Optics Express

Depth-resolved attenuation in optical coherence tomography (OCT) can provide quantitative optical contrast beyond structural imaging. However, conventional reconstruction methods can be biased when the OCT signal does not fully decay within the imaging range or when the distal signal tail is dominated by noise or residual reflections from distal sample or support interfaces. Here, we present a perturbation-based Beer-Lambert framework that combines a zeroth-order exponential estimate with a first-order correction, reducing reliance on the unreliable distal signal tail below the current depth. Numerical A-line simulations, Monte Carlo modeling, multilayer silicone-dye-TiO2 phantoms, and ex vivo bovine retina experiments were used to evaluate the method under finite-depth and heterogeneous imaging conditions. The numerical A-line tests showed reduced depth-dependent error against prescribed attenuation profiles; the Monte Carlo comparisons showed less distal drift relative to model-defined benchmarks, while the phantom profiles were compared with separately acquired single-layer OCT calibration values. In a Monte Carlo component test that withheld vessel-mask and vessel-boundary information from reconstruction and used that information only for post hoc evaluation, the first-order correction recovered 61% of the segmentation-informed target vessel contrast and reduced vessel ROI mean absolute error by 65% relative to the fixed zeroth-order baseline. These results suggest that perturbation-based reconstruction may provide a practical approach for depth-resolved reconstruction of effective OCT attenuation when the fully decayed A-line condition is not satisfied.

0.30

X-Strata: Separating Aneurysms and Overlapping Vessels into Layers from 2D X-ray Angiography

eess.IV cs.CV ·2026-11-13 ·Zhihong Wen, Congzhou Chen, Hucheng Li, Xun Han, Jianning Zhang +7 more
similarity 0.52
Abstract · 22 pages, including 10 pages of supplementary material

An X-ray angiogram sums every structure along a ray into one pixel. When vessels cross an aneurysm, they obscure part of it and mix their contrast into its filling curve. We present X-Strata, a network that separates a cine angiogram into three layers: the complete aneurysm sac, the vessels in front of it, and the vessels behind it. Contrast timing indicates how much each layer contributes to a pixel, and parallax between two views indicates their order, which a single view cannot determine. X-Strata first estimates the layers and their contrast curves, then uses the second view to assign vessels to the front or back layer, and lifts all layers into 3D. It learns from layer labels projected from same-session 3D rotational angiography, but needs only 2D cine runs and their acquisition geometry at inference. On 220 held-out patients from three centers (122 external), two-view X-Strata ranks first among 14 baselines, including VGGT and C$^2$RV, in recovering the sac where vessels overlap it (Dice 0.693 internal, 0.641 external) and in ordering the layers (balanced accuracy 0.703, 0.659). Its order accuracy exceeds that of all 11 end-to-end baselines by at least 4.1 points internally and 3.3 externally (Holm-adjusted $p < 0.001$) and grows with view separation. Recovered 3D sac surfaces have a median Chamfer distance of 0.34 mm on the internal cohort. X-Strata may therefore provide layered aneurysm and vessel information, including 3D sac shape, for patients who undergo only 2D angiography.

0.20

Low-rank MERA Decomposition of 3D OCT Image Volume for Compression, Denoising, Feature Extraction and Diagnosis of Retinal Diseases

cs.CV ·2026-10-26 ·Ivica Kopriva, Fei Shi, Marija Štanfel, Qin Peng, Jianhao Bao +2 more
similarity 0.51
Abstract · 10 pages, 4 figures, 5 tables

Optical coherence tomography (OCT) is a non-invasive imaging modality used for visualization of retinal tissue. However, OCT volumes are affected by speckle noise, which degrades image contrast and obscures fine structural details. Furthermore, modern clinical practice requires large field-of-view, high-resolution OCT volumes, whose storage and transmission are demanding for archiving and teleophthalmology applications. To address aforementioned challenges, we propose a low-rank multi-scale entanglement renormalization ansatz (MERA) tensor network approximation of 3D OCT image volume, where the image volume is represented as contractions of a top core factor encoding global features and multiple interacting low-rank orthogonal or semi-orthogonal factors modeling inter- and intra-B scan correlations. This representation jointly enables compression, denoising, and feature extraction. Unlike deep learning approaches, the proposed approach is training-free and processes each OCT volume independently. We evaluate the proposed framework on OCT image volumes acquired by two different scanners and demonstrate improved visual quality and reduced retinal layer segmentation errors in comparison with several competing methods. We also extract MERA features from two clinical OCT volume datasets. They are subsequently classified using a Grassmann-manifold nearest-subspace classifier. With the subspace dimension as its only hyperparameter, the classifier is theoretically shown to be robust in small-sample clinical scenario. We demonstrate competitive accuracy of classification of retinal diseases in these small-sample settings, where deep learning methods are often limited by the scarcity of labeled data. The proposed structure-aware model-driven representation learning for high-dimensional data under limited supervision provides good generalization performance while maintaining high interpretability.

0.35