CS Paper Radar

Magnetically Self-Sealed MR Haptic Actuator With PWM-Based Excitation and High-Fidelity Torque Control

Dong Qiang, Tian Yuan, Song Yang, Kequan Xia, Thomas Reddyhoff, Yikun Zhang, Cheng Cheng, Min Yu

cs.RO eess.SY ·submitted 2026-08-20 05:04 UTC · v1

Abstract

Accurate and stable torque rendering is essential for safe and perceptive human--machine interaction. Magnetorheological fluid (MRF)-based actuators offer a compact and rapidly controllable solution for haptic feedback, but their practical implementation requires reliable fluid sealing, low-hysteresis excitation, accurate torque control, and stable long-duration operation. This article presents an integrated MRF haptic system featuring a compact magnetically self-sealed rotary actuator, low-hysteresis PWM operation, high-fidelity model-based torque rendering, and stable performance during long-time operation. Magnetostatic simulation guides the arrangement of magnetic and nonmagnetic materials to focus flux in the multidisk torque and permanent-magnet sealing regions, enabling a maximum 600 N$\cdot$mm/A output. Experiments show that higher PWM frequencies reduce hysteresis and improve repeatability. At 10 kHz, the response is represented by a nonlinear model that varies with the direction and speed of torque change. The real-time controller combines feedforward, hysteresis compensation, PI feedback, and sliding-mode correction. Compared with PID, it reduces square-wave overshoot, undershoot, and steady-state RMSE by 77.4\%, 61.9\%, and 68.3\%, respectively. It tracks sinusoidal and biomechanics-model-based references, and a 1.5-h test shows only a 2.5 $^\circ$C rise near the coil with no clear tracking loss. This high-fidelity torque rendering will fundamentally transform human--robot collaboration by making interactions safer, more efficient, and more intuitive.

Comment
Submitted to IEEE/ASME Transactions on Mechatronics. 16 pages, 9 figures, including supplementary material

Closest papers

Nearest neighbours by meaning across the whole index.

Compact and Wide-Force-Range Magnetorheological Hand Exoskeleton for Kinesthetic Feedback in Teleoperation

cs.RO eess.SY ·2026-11-09 ·Xianlong Mai, Rui Yu, Rui Chen, Daniele Leonardis, Wenbo Li +3 more
similarity 0.59
Abstract

Hand kinesthetic feedback is crucial for restoring and enhancing human perception of force and displacement in robotic hand teleoperation. Wide perception range of force feedback is vital in rendering objects of different stiffness, especially for high-stiffness rendering. However, existing approaches struggle to achieve wide range of force feedback while maintaining compact and wearable design. This paper presents a hand exoskeleton system employing magnetorheological (MR) brakes to provide a wide range kinesthetic feedback during teleoperation. The MR brake provides a braking torque ranging from 0.01 to 0.918 Nm, while maintaining a compact structure with a total mass of only 39.8 g. The proposed exoskeleton can render fingertip forces up to 21 N while maintaining back-driving force of 1.01 N. Experimental results show that the system allows users to discriminate object stiffness using kinesthetic feedback alone. In a tele-grasping task, when both conditions achieved a 100% success rate, kinesthetic feedback led to a 28.2% reduction in object contact force compared to visual feedback only, enhancing object safety and operator immersion. Questionnaire results further indicate that kinesthetic feedback improves reliability, realism, and user confidence during teleoperation.

0.22

Surgical Master Console Using General-Purpose Robot Arms and a Separable Articulated Distal Interface: Porcine In-Vivo Evaluation

cs.RO ·2026-09-27 ·Minsung Kim, Seonho Shim, Dongho Yee, Younghoon Noh, Juahn Oh +7 more
similarity 0.52
Abstract · Submitted to IEEE ICRA 2027

High-performance surgical master consoles offer intuitive articulated manipulation but are expensive and difficult to reproduce, while accessible commercial haptic devices lack built-in interfaces for surgical wrist articulation and continuous grasp. We present a laparoscopic master in which general-purpose robot manipulators provide the programmable base and surgical-specific interaction is concentrated in a separable distal adapter. Each 6-DoF arm carries a custom 2-DoF direct-drive wrist, continuous grasp sensing, and clutch-based workspace management; the complete bimanual hardware costs approximately US$5,500, below common bimanual commercial haptic references. To support sustained hand-guided use, we characterize current scaling, gravity, and break-away friction and use them for posture-dependent gravity compensation and motion-gated assistance, reducing continuous actuation and thermal loading. A common master state drives either Isaac Sim or an RCM-constrained dual-FR3 platform. Master-state publication to FR3 target update adds at most 8 ms, and tip tracking shows 0.31-0.66 mm mean delay-aligned residuals. In a porcine cholecystectomy experiment, five common operator-side metrics and hand/tip-speed distributions were compared descriptively with human in-vivo telemetry from 120 clinical Versius recordings of 99 cholecystectomy procedures; no interruption originated from the master console, and no abnormal clinical signs were recorded during the 7-day postoperative observation period. These results demonstrate a surgical master built from general-purpose robot arms with surgical-specific interaction concentrated in a separable distal interface.

0.32

A Disk-Shaped Magnetoelastic Torque Sensor for Robotic Joints Using Permanent Magnetization

cs.RO eess.SY ·2026-09-27 ·Bruno Brajon, Enrico Gasparin, Nicole Yazigy, Lisa Salamin, Florian Copt +3 more
similarity 0.50
Abstract

Direct torque sensing is a growing need in the robotics community to enable precise control and interactions where torque estimation from motor current is not sufficient. This paper presents a novel disk-shaped magnetoelastic torque sensor with a compact axial envelope of about 1 cm, suitable for integration in robotic joints. A four-magnetometer architecture is used to measure the field modulated by the stress affecting a narrow magnetized region while rejecting the effects of parasitic cross forces. A custom-designed magnetic shield enhances the torque sensitivity while reducing the external stray fields by a factor 7x. The device measures the torque with an accuracy of 1.34 %FS relative to the 50 Nm full scale (FS). The paper details the development of the sensor through the mechanical design, the magnetization procedure, and the experimental validation. The results demonstrate the potential of the proposed sensor for robotic applications.

0.24

A Task-Agnostic Control Strategy for Dynamic Assistance with Pneumatically Actuated Soft Exosuits

cs.RO cs.HC ·2026-08-18 ·Anoush Sepehri, Zachary Huang, Raymond de Callafon, Michael T. Tolley, Tania K. Morimoto
similarity 0.49
Abstract

Pneumatic artificial muscles have provided new opportunities to develop upper-extremity soft exosuits for reha- bilitation, augmentation, and assisted daily living. However, the complex dynamics and limited bandwidth of these actuators has made providing responsive assistance based on user intention a longstanding challenge. In this work, we present an inverse-plant control strategy for pneumatically actuated soft exosuits that only relies on kinematic sensing for task-agnostic and dynamic assistance during daily living. We model the human-robot system using a Hammerstein dynamic model, consisting of a Preisach hysteresis model and a linear time-invariant filter, to capture the static and dynamic behavior of the system. We personalize our model to each user using 140 s of data and approximate an inverse to integrate into our control loop. When evaluated on a test rig that emulated a soft assistive exosuit for the wrist, our controller reduced the interaction torque by up to 73% and the activation of key flexor and extensor muscles by up to 47% relative to the condition with no assistance for speeds ranging from 8°/s to 120°/s. Overall, this work presents a control strategy that can provide task-agnostic, dynamic assistance with pneumatically actuated soft exosuits without the need for physiological or force sensors to interpret user intention.

0.19

A Transparent 3-DoF Assistive Device for Upper-Limb Tremor and Ataxia Compensation: Design and Experimental Validation

cs.RO ·2026-10-22 ·Thomas Dobosz, Veronika Hofmann, Ahmed Barhoma, Ann-Kathrin Henke, Johannes A. Gaus +10 more
similarity 0.49
Abstract · 8 pages, 7 figures, 3 tables, Preprint

Assistive devices for patients with neurodegenerative movement disorders must combine high mechanical transparency with the ability to generate corrective interaction forces. Achieving both properties simultaneously remains challenging. This paper presents the completed iAssistADL platform, a 3-DoF assistive device for future tremor and ataxia compensation during activities of daily living. The system employs a transparency-oriented mechanical architecture with all actuators located at the base, resulting in low moving mass, decoupled kinematics, and high mechanical transparency. To compensate for friction-induced transparency limitations along the vertical axis, a hybrid control strategy is proposed that combines open-loop force rendering in the horizontal plane with closed-loop force control in the vertical direction. The platform is experimentally evaluated through transparency measurements and static and dynamic force-rendering experiments at representative configurations. Results demonstrate resistive torques below 0.1 Nm in the horizontal plane, end-effector forces of up to approximately 10 N throughout the workspace, and accurate horizontal force rendering up to 4 Hz. While the vertical axis remains limited by friction-induced dynamics at higher frequencies, the proposed system successfully combines high transparency with controlled force generation, establishing a promising hardware platform for future tremor and ataxia compensation.

0.27

XRoboToolKit-T: Teleoperation with High Stability and Precision with Tactile Sensing for Contact-rich Manipulation

cs.RO cs.HC ·2026-09-14 ·Xiwen Dengxiong, Xueting Wang, Ke Jing, Rui Li, Yunbo Zhang
similarity 0.48
Abstract

Collecting high-quality robot data for contact-rich manipulation tasks is essential for enabling robots to acquire real-world skills. However, existing data collection solutions often lack the capability to obtain stable and high-frequency tactile feedback, limiting their effectiveness in contact-rich manipulation scenarios. In this work, we propose a versatile teleoperation system with tactile-driven assistance to enable high-frequency and stable contact-rich manipulation. The proposed XRoboToolKit-T teleoperation system incorporates a tactile-informed force control architecture, designed to ensure both stable and precise force control in contact-rich manipulation during teleoperation. The stabilizer haptic module rapidly analyzes the normal force distribution and infers pseudo shear force, enabling real-time tactile-based assistance during manipulation. The refiner haptic module integrates a vision-language-action model to predict and refine manipulation actions based on tactile sensing data and task descriptions. We apply the proposed teleoperation system to challenging contact-rich manipulation tasks, including grasping a deformable rubber pipette for liquid transfer and inserting a medical syringe into a vascular training pad, to demonstrate the effectiveness of tactile-informed force control. Furthermore, the system achieves higher data collection efficiency and improved manipulation stability compared to state-of-the-art teleoperation without tactile assistance.

0.23

Hall Effect-Based Tactile Force Detection Sensor for Robot-Assisted Minimally Invasive Surgery

cs.RO ·2026-10-07 ·Charles DeLorey, Michael Brockdorff, Adam Metcalf, Benjamin Calmé, Pietro Valdastri +1 more
similarity 0.48
Abstract · 9 pages, 12 figures

Robotic minimally invasive surgery has revolutionized surgical practice. However, as the surgeons are mechanically separated from the surgical tools, loss of tactile feedback occurs. We present a compact force sensor with three, millimeter scale sensing elements (taxels) that can be affixed to the grasping face of a robotic surgical tool. The sensor features a miniaturized design using Hall effect sensors and magnets embedded in a deformable elastomer contact layer. Sensor calibration is achieved with a 6 degree of freedom (DoF) parallel robot. Each taxel can detect applied normal and shear forces with average RMSE of 2.133 kPa. The calibrated sensor was validated on phantom and ex vivo porcine tissue, demonstrating tactile sensing during retraction as well as slip. This work introduces a small-scale Hall effect based tactile sensor, enabling sensing for force-sensitive robotic surgical applications.

0.17

Ultra-Low-Impedance Robotic Gripper for High-Bandwidth and Transparent Physical Interaction

cs.RO ·2026-08-10 ·Joon Lee, Ari Choi, Seokhwan Jeong
published similarity 0.47
Abstract · ICRA 2026 (Late Breaking Result Poster)

Conventional robotic grippers often use high-ratio transmissions to generate grasping torque and external force sensors to measure physical interaction. High-ratio transmissions increase friction, reflected inertia, and mechanical impedance, while external sensors add hardware complexity. To address these trade-offs, this study proposes a novel 9-DOF, three-fingered Differential Direct-Drive (DDD) gripper that combines DD motors with a low-ratio (1:2) differential transmission. The mechanism centralizes actuator mass at the base to minimize moving-link inertia, while the differential architecture couples two motors in parallel to amplify torque during flexion. Experiments show that the prototype delivers a nominal grasping force of approximately 18 N and a fingertip force of 4.7 N, while maintaining a low motor contribution to system inertia (0.236%) and low passive mechanical impedance, with a maximum measured value of 50.1 N/m when the motors are unpowered. The proposed hardware addresses the trade-offs among torque, physical transparency, and kinematic dexterity, providing a foundation for high-bandwidth interaction and sensorless proprioceptive force estimation.

0.19