Multivariable Geometric Laplace Transform and Fault Detection in Distributed-Converter Lines

Francisco Manuel Arrabal-Campos, Francisco G. Montoya, Santiago Sánchez-Acevedo, Raymundo E. Torres-Olguin, Alfredo Alcayde

eess.SY eess.SP ·submitted 2026-09-02 10:50 UTC · v1
code/data

Abstract

Monitoring a DC line with many distributed power converters is a genuinely spatio-temporal problem: the information about a localized fault travels along the whole conductor and reaches a few measurement points mixed with the dynamics of the line itself. This paper develops a two-dimensional geometric Laplace transform (t,x) -> (s_t,s_x) over a commutative subalgebra of the geometric algebra Cl(4,0), isomorphic to Segre's bicomplex numbers, in which two bivectors B_t and B_x act as independent imaginary units for the temporal and the spatial phase. Because the two phases live in algebraically distinguishable planes, a fault at position x_f leaves a transformed residual that factorizes as F_f(s_t) e^{-s_x x_f}: its temporal nature stays in the first factor and its location can be read as a geometric argument of the second. On this representation we build a transmission-line model of the converter line and its space-time dispersion relation, a distributed control by admittance shaping, including an exact treatment of discrete converter sites (spatial sampling, aliasing, and a per-converter droop realization that is exact on the sub-Nyquist band), and a fault diagnosis chain that detects, localizes and classifies injection-loss, shunt, sensor and local-controller faults, extends to multiple simultaneous faults with automatic order selection, and distinguishes the outage of a plant from a cable defect. As an integral object the transform is known in bicomplex analysis, and with a single independent variable it reduces to the complex Laplace transform; the contribution lies in its geometric embedding and in its operational use for fault diagnosis in distributed-converter networks. All results are reproduced by an accompanying open implementation.

Comment
56 pages, 13 figures, 5 tables. Code and data available at https://github.com/fmarrabal/geo-laplace-distributed-converters

Closest papers

Nearest neighbours by meaning across the whole index.

The geometric Laplace transform: Definition, existence and properties of the Geometric Algebra Laplace transform

eess.SY math.OC ·2026-08-18 ·Manel Velasco, Arnau Dòria-Cerezo, Isiah Zaplana
unusual similarity 0.63
Abstract · 42 pages, 0 figures

Recent publications have started to explore the application of Geometric Algebra (GA) to the modeling, analysis and control of dynamical systems and, in particular, electrical circuits. Since a crucial element there is to transform the ordinary differential equations governing the dynamical system which models the systems' behavior from the real domain to the Laplace domain, a definition of the Laplace transform in GA is needed. In the present work, we extend previous works dealing with extension to some hiper-complex algebras by introducing a definition of the Laplace transform within the framework of Geometric Algebra (GA). In particular, our definition and its properties are applicable to geometric algebras with signature lower or equal than 5.

0.31

From Rigid to Adiabatic: Canonical Regularization of AC Networks via Action-Angle Variables

eess.SY ·2026-08-29 ·Feng Ji, Lu Gao, Lihui Yang
similarity 0.46
Abstract

Traditional power system analysis relies on timescale separation and the rigid-network assumption, freezing electromagnetic transients into algebraic power-flow equations via Steinmetz's phasor theory. As grid-forming converter penetration increases, magnetic energy dynamics on transmission lines interact with converter control loops on comparable timescales, challenging this rigid-network assumption. Returning to Faraday's law of electromagnetic induction driven by rotating magnetic fields, this paper models the transmission lines' rotating magnetic fields in action-angle canonical coordinates, regularizes the rigid algebraic constraints of power-flow equations into canonical equations on adiabatic symplectic manifolds, and establishes a port-Hamiltonian standard form for AC power grids. Based on the minimal-counterexample principle and using the equal-area criterion's classical two-machine system, this paper reveals a latitudinal instability channel via Bloch-sphere coordinates: Q-V control releases voltage-amplitude freedom, shifting the stability boundary from the equatorial UEP (unstable equilibrium point) to a saddle point, thereby unifying the analytical frameworks of P-delta angle stability and Q-V voltage stability in power system analysis.

0.27

Unifying Power Flow and Electromagnetic Transient Modeling

eess.SY ·2026-09-08 ·Tina Gao, Aayushya Agarwala, Timothy McNamara, Lawrence Pileggi
similarity 0.43
Abstract

Grid tools are separated by timescales: steady-state analysis is performed by power flow (PF), whereas the fastest dynamics are captured by electromagnetic transient (EMT) simulation. Although operating at varying timescales, different tools should produce consistent results when analyzing the same grid conditions. However, the PF steady-state solution does not match the time-to-infinity EMT response. This mismatch exists because simplified device models in PF are inconsistent with the "ground truth" EMT models derived from first principles. As inverter-based resources (IBRs) and data centers strip away inertia and operating reserves, approximations used in PF risk grid security by missing violations. To address this, we introduce a steady-state framework that uses full-physics EMT models for high-fidelity steady-state grid analysis. The challenge lies in systematically formulating algebraic frequency-domain representations of dynamic power devices that are naturally described in state-space form. Our tool, SALT (Steady-state After Last Transients), constructs steady-state representations that exactly capture grid device physics when embedded into transmission networks. The approach exploits the structural properties of power device models and the single-harmonic, balanced nature of the transmission system. Results demonstrate SALT achieves EMT steady-state accuracy while delivering a 1x10^6 times speedup. We demonstrate that SALT can capture security threats in contingency scenarios without exception --- whereas PF-based analyses reported 75% fewer rated line violations, 18% fewer Q-limit violations, and 7% fewer voltage violations.

0.20

Moment Matching for Descriptor Systems: A Möbius Mapping Approach

eess.SY ·2026-09-06 ·David Militaru, Denisa Jungheatu, Andrei Sperilă, Tudor C. Ionescu
unusual similarity 0.42
Abstract · 9 pages, 1 figure with 3 subfigures

For a class of single-input single-output systems described by proper or improper transfer functions, we propose moment-matching procedures applicable in both continuous- and discrete-time contexts. The resulting technique is not only more flexible and reliable than other procedures which are currently available in literature, but it also enables the placement of constraints on the reduced-order model's poles and zeros. This constraint-based feature, hitherto available only for continuous-time state-space systems, is illustrated via a numerical example based on a practical problem from literature.

0.30

Impact of Reduced-Order Modelling on Sum-of-Squares Region-of-Attraction Certification for Grid-Forming and Grid-Following Converters

eess.SY math.OC ·2026-11-10 ·Chenxi Yuan, Jeremy D. Watson, Neville R. Watson
similarity 0.41
Abstract · 13 pages, 5 figures, 3 tables

With the increasing penetration of power-electronic equipment, the transient stability of grid-forming (GFM) and grid-following (GFL) converters is increasingly characterized through the region of attraction (ROA) of the post-fault equilibrium. Sum-of-squares (SOS) programming yields certified inner approximations of the ROA, yet its computational cost grows rapidly with system order. Reduced-order models are therefore widely used to reduce computational cost and, more importantly, to enable analytical investigation. However, ROA analyses based on these models often assume that reproducing the converter's transient response, or retaining more dynamics in the correct time-frame, is sufficient to preserve the ROA of the full-order system. Using time-domain ODE simulations as a reference, the SOS-based ROA of each reduced-order GFM and GFL model is assessed against both its own simulated ROA and that of the corresponding full-order model, thereby separating SOS-induced conservativeness from model-order-induced ROA distortion. The results indicate that increasing reduced-order model complexity does not necessarily improve SOS-based ROA fidelity. In the cases examined, more complex reduced-order models yield lower SOS coverage of the full-order reference ROA, despite closer ODE-boundary agreement in some regions. Model selection should therefore consider both full-order ROA fidelity and certified coverage of the practical operating range, rather than model complexity alone.

0.27

Computing Scaled Relative Graphs of Discrete-Time LTI Systems: A Frequency-Domain Approach

eess.SY ·2026-09-29 ·Guoming Shi, Fredy Ruiz
similarity 0.41
Abstract

The scaled relative graph (SRG) represents the joint gain and phase properties of an input--output operator in the complex plane. This paper characterizes the SRG closure of causal, stable, square discrete-time linear time-invariant (LTI) systems on one-sided square-summable sequences. The Beltrami--Klein image of this closure equals the convex hull of the numerical ranges of the transformed frequency-response matrices. For real-coefficient single-input single-output systems, this yields the hyperbolic convex hull of the discrete-time Nyquist locus. The proof addresses the Hardy-space restriction imposed by one-sided inputs, which excludes persistent sinusoids, by replacing them with explicitly constructed finite-duration sinusoids. This construction shows how points in frequency-wise SRGs arise as limits of operator SRG points generated by admissible inputs. The characterization enables model-based computation of the closure from a state-space realization using frequency-response evaluations, numerical ranges, and planar convex hulls, without solving linear matrix inequalities.

0.52

Harmonic Stability of Power Systems: A Control-Theoretic Definition and Assessment Criteria

eess.SY ·2026-08-20 ·N. Bhoir, A. Sarkar, J. E. Machado, J. Schiffer
similarity 0.41
Abstract

Harmonic interactions have become a defining dynamic stability phenomenon in converter-based power systems (CBPSs). However, a formalization of the notion of harmonic stability in the context of nonlinear dynamical systems is not available thus far. In this paper, we propose a definition of harmonic stability formulated as a combination of two standard stability notions, namely, bounded-input bounded-output (BIBO) and internal stability properties with respect to any nominal periodic trajectory. Moreover, we rigorously show that the local harmonic stability of any nominal periodic trajectory of nonlinear CBPSs is implied by the stability properties of its linear time-periodic (LTP) approximation. In addition, to enable computationally tractable stability assessment, we develop a framework based on harmonic state-space (HSS) representations of LTP models. In particular, we provide time-invariant linear matrix inequality (LMI) conditions to certify harmonic stability. The proposed methodology is illustrated on a grid-following converter system, where the HSS-based analysis numerically confirms harmonic stability around the periodic operating trajectory.

0.29

Equivalent DQ Sequence-Domain Model of Unbalanced Three-Phase Passive Elements for Power Converter Controllers

eess.SY ·2026-09-01 ·Air\án Franc\és, Luis Saz, Rafael Castillo, Dionisio Ramirez, Javier Uceda
publishedtheoryhighly cited similarity 0.40
Abstract · 8 pages, 7 figures, 2023 IEEE Applied Power Electronics Conference and Exposition (APEC)

Equivalent dq0 models of three-phase passive impedances are widely used for the design of three-phase inverter and rectifier controllers in the synchronous frame. However, these equivalent models assume that the impedance in each phase are the same, which is not always applicable. The fact that the impedance in each phase is different, generates second order harmonic content in the dq0 components, which hinders the advantages of the dq0 transformation. To avoid the second harmonic in these scenarios, it is possible to use the Fortescue's theorem to represent any asymmetrical set of three-phase signals as a linear combination of three symmetrical sequences. In the literature, only a few works have attempted to derive the equivalent model of unbalanced three-phase passive elements in the sequence domain, and none is able to account for the interaction between the zero sequence and the positive and negative sequences. This work presents the derivation of the equivalent dq sequence-domain model of unbalanced three-phase passive elements both analytically and with an intuitive graphical approach. Experimental results are shown to validate the proposed models.

0.73