CS Paper Radar

High-Velocity Whip-Mode Microresonator in LTOI Unimorph: Measurement Methodology and Large-Signal Characterization

Tzu-Hsuan Hsu, Zihuan Liu, Harshvardhan Gupta, Ziqian Yao, Wei Wang, Vakhtang Chulukhadze, Jack Kramer, Neal Hall, Ruochen Lu

eess.SP ·submitted 2026-09-16 22:15 UTC · v1
theoryunusual

Abstract

This paper presents the design, characterization, and large-signal measurement methodology of a high-order whip-mode flexural microresonator on a lithium tantalate-on-insulator (LTOI) unimorph platform. A tapered cantilever concentrates kinetic energy at the free tip through a structural velocity amplification effect, with a targeted whip mode at 9.175 MHz exhibiting a measured Q of 691 in air. The results indicate a substantially reduced susceptibility to viscous damping at high modal frequencies. In-air large-signal testing on a separate device confirms tip velocities up to 20 m/s before the reliable measurement range of the laser Doppler vibrometer (LDV) at the tapered tip is exceeded, while the device itself sustains drive levels up to 240 Vpp before failure. Transitioning to vacuum reveals photothermal-induced static bending of the LTOI cantilever under LDV laser illumination, an effect that prohibits direct velocity measurement for these resonators. Hence, it motivates an indirect extraction methodology to be implemented. In this work, a 3.85 times base-to-tip geometric amplification factor, independently calibrated at low drive, is applied to base velocity measurements to infer tip velocity under large-signal conditions. Using this approach with narrowband chirp excitation, a maximum extracted tip velocity of 58.9 m/s is obtained at 192 Vpp, with spectral analysis of the base velocity placing a conservative lower bound of 36.2 m/s on this estimate. Large-signal failure-mode analysis identifies Pt/Au electrode melting at 210 Vpp as the current velocity ceiling. These results suggest that geometric amplification in high-order flexural modes offers a viable pathway toward the high proof-mass velocities targeted for next-generation MEMS inertial sensors.

Comment
10 pages, 9 figures, 2 tables. Submitted to IEEE Journal of Microelectromechanical Systems

Closest papers

Nearest neighbours by meaning across the whole index.

Bilayer Periodically Poled Piezoelectric Thin-Film Lithium Tantalate Platform for Passive-Layer-Free Flexural and Torsional Actuation

eess.SP ·2026-11-11 ·Tzu-Hsuan Hsu, Jiajun Huang, Zihuan Liu, Yen-Chen Wang, Vakhtang Chulukhadze +2 more
published similarity 0.53
Abstract · 4 pages, 7 figures, 1 table. Accepted to the 2027 IEEE 40th International Conference on Micro Electro Mechanical Systems (MEMS 2027)

This work demonstrates, to the best of our knowledge, the first passive-layer-free thin-film lithium tantalate (LT) actuator platform, supporting both out-of-plane flexural and in-plane torsional actuation from a single bilayer periodically poled piezoelectric film (P3F) X-cut LT stack. The polarity reversal across the bond interface flips the piezoelectric stress below the neutral axis, generating a bending moment without any passive elastic layer. Moreover, the two layers share identical elastic and thermal-expansion constants, making the stack thermally matched by construction. Suspended cantilever devices were fabricated on a single 2$\times$1.5 $μ$m X-cut LT stack and verified by laser Doppler vibrometry (LDV). The tapered flexural resonator exhibits a 5.5$\times$ tip velocity amplification and a measured peak tip velocity of 10.3 m/s at $Q=634$, and a 0.49 MHz torsional cantilever resonator with $Q=514$ is demonstrated on the same stack. These results position bilayer P3F LT as a thermally matched, passive-layer-free actuation platform for vacuum-operated and optically interrogated MEMS such as scanners, gyroscopes, and ultrasonic transducers.

0.37

Thickness-Field-Excited Bimorph Piezoelectric Micromachined Ultrasonic Transducer in Submicrometer Thin-Film Lithium Niobate

eess.SP ·2026-11-09 ·Vakhtang Chulukhadze, Jiajun Huang, Zihuan Liu, Will Leskowitz, Tzu-Hsuan Hsu +6 more
similarity 0.50
Abstract · 8 pages, 11 figures

This work presents the first demonstration of a submicrometer-thick thickness-field-excited (TFE) lithium niobate (LN) flexural-mode piezoelectric micromachined ultrasonic transducer (PMUT). A 670-nm-thick bilayer periodically poled piezoelectric film (P3F) 128Y LN is used to demonstrate a suspended membrane with an area of 0.25 mm$^{2}$, achieving a low resonance frequency of 33.4 kHz for airborne transduction. Its electrical measurements reveal an extracted effective electromechanical coupling efficiency ($k_{\mathrm{eff}}^{2}$) of 3% and a moderate static capacitance $C_0$ of 17 pF. Meanwhile, mechanical measurements using a laser Doppler vibrometer (LDV) yield a high quasi-static peak out-of-plane displacement ($ξ_{\mathrm{static}}$) of 145 nm/V and a high corresponding open-circuit sensitivity ($S_{\mathrm{OC}}$) of 1.4 mV/Pa in the audio band. The fabricated device is compared with state-of-the-art (SoA) airborne piezoelectric transducers with sub-100-kHz resonance frequencies, underscoring the potential of the TFE P3F LN transducer platform by simultaneously demonstrating strong actuation capability while featuring high sensitivity.

0.33

13,000-Fold Frequency Down Conversion From 280 MHz to 21 kHz Using Mechanical Frequency Combs

eess.SP ·2026-11-05 ·Ian Anderson, Zihuan Liu, Vivek Tallavajhula, Yen-Chen Wang, Tzu-Hsuan Hsu +2 more
unusual similarity 0.50
Abstract · 4 pages, 6 figures

Optical frequency combs bridge the microwave and terahertz regimes by down-converting terahertz optical energy into microwave signals. A photodetector converts the comb's equally spaced lines, generated through optical nonlinearities, into a low-frequency tone at their spacing. Here, we present the first mechanical version of this process, using mechanical frequency combs to downconvert energy over 4 orders of magnitude, from the MHz to kHz regime. Thin-film lithium niobate (LN) is used to design an acoustic resonator with a wide range of mode frequencies. We achieve phononic comb excitation from 250 MHz to 900 MHz and compare the electrical and laser Doppler vibrometer (LDV) measurements at 277 MHz. We then show the low-frequency spectrum of the devices, highlighting mechanical motion at the comb's spacing and demonstrating energy transfer from 277 MHz to 21 kHz.

0.30

20 ghz longitudinal surface acoustic wave resonators in 100-nm x-cut lithium niobate on silicon carbide

eess.SP ·2026-11-19 ·Jiajun Huang, Ziqian Yao, Tzu-Hsuan Hsu, Ian Anderson, Joshua Campbell +1 more
similarity 0.44
Abstract

Surface acoustic wave (SAW) resonators above 15~GHz require a fast acoustic mode that retains strong electromechanical coupling ($k^2$). This work reports longitudinal SAW (L-SAW) resonators designed for high $k^2$ in 100-nm X-cut lithium niobate (LN) on 4H silicon carbide (SiC), operating up to 21.7~GHz and reaching a $k^2$ of 8.1\%, a maximum Bode $Q$ of 70, and a figure of merit (FoM) of 5.7 at 20.24~GHz. In this thin-film waveguide, shrinking the wavelength ($λ$) keeps the normalized LN thickness ($h_\mathrm{LN}/λ$) large, sustaining both $k^2$ and acoustic confinement. Conversely, increasing $λ$ from 292 to 471~nm lowers $h_\mathrm{LN}/λ$ from 0.34 to 0.21 and raises the L-SAW phase velocity from 6.32 to 7.05~km/s, within 1.1\% of the 7126-m/s shear-wave velocity of 4H-SiC. As the velocity approaches this limit, more of the acoustic energy spreads into the non-piezoelectric SiC, and $k^2$ falls from its 8.1\% peak at $λ= 322$~nm to 1.7\% at $λ= 471$~nm. No L-SAW resonance is observed for $λ\geq 518$~nm ($h_\mathrm{LN}/λ\leq 0.19$), where the mode becomes leaky. Overall, the FoM stays within 5\% of its maximum for $h_\mathrm{LN}/λ$ between 0.26 to 0.31, defining a design window for L-SAW resonators in thin LN on SiC at K-band and beyond.

0.27

Lithium Niobate Surface-Acoustic-Wave Resonator for Very-High-Frequency Isolated Power Conversion

eess.SY physics.app-ph ·2026-10-02 ·Liyang Jin, Zhiyang Cao, Zichen Xi, Jun Ji, Yizheng Zhu +2 more
unusual similarity 0.42
Abstract

Piezoelectric devices offer a promising magnetic-free alternative for high-frequency power electronics, enabling compact energy transfer with inherent galvanic isolation. Here we demonstrate a lithium niobate surface acoustic wave (SAW) resonator that enables isolated power transfer and addresses the challenges in existing piezoelectric devices for power applications, including operation frequencies, power delivery figure of merit (FOM), power handling, and electrical isolation. Our application-optimized 40-MHz SAW resonator, with the two electrically isolated interdigital transducers (IDTs) and acoustic Bragg mirrors, achieves a 25.7 W output power at a less than 15 °C temperature rise with only passive cooling through the back mounting side, and an isolation voltage of 2.17 kV. In DC-AC power conversion, we demonstrate a peak efficiency of 93.8 %, a power delivery FOM of 13.47 mW/V$^2$ and a peak chip power density of 81.7 W/cm$^3$. DC-DC conversion is also demonstrated by connecting a diode rectifier to the output IDT, despite efficiency degrading to 52.7 %. Our results advance SAW devices as one of the core components for next-generation very-high-frequency, miniaturized, high-density, magnetic-free, isolated power converters.

0.26

Modeling and Design of a Diaphragm-Integrated Photonic Waveguide Microphone

eess.AS ·2026-10-13 ·Xiaoyu Niu, Yuqi Meng, Zihuan Liu, Ehsan Vatankhah, Neal Hall
benchmark similarity 0.37
Abstract · 14 pages

Can an integrated optical readout improve the useful operating range of a miniature microphone? We address this question with an analytical model of a diaphragm carrying the sensing arm of a Mach-Zehnder interferometer (MZI). The model links pressure-induced bending to waveguide elongation and then to photocurrent, allowing mechanical sensitivity and optical detection limits to be assessed separately. Optical shot noise and back-cavity thermomechanical noise set the pressure resolution, while a 10% total harmonic distortion criterion defines acoustic overload. Two operating regimes are examined: a compact MEMS microphone with 1 mW optical input and a measurement microphone with 100 mW optical input. For the compact case, a 1 mm diameter, 1 micrometer thick, stress-free silicon diaphragm and 100% modulation efficiency give a predicted signal-to-noise ratio of 78 dB and acoustic overload pressure of 124 dB. The higher-power case lowers the modeled noise floor and increases dynamic range relative to the selected measurement microphone benchmark. These estimates rely on favorable assumptions and do not establish a substantial overall advantage in conventional microphone applications. Remote optical interrogation offers a separate motivation for harsh-environment sensing, but the temperature tolerance of the proposed sensing head remains unverified. The analysis identifies the design tradeoffs and measurements needed to test the predicted performance.

0.09

Non-Imaging Optical Tactile Sensors for Robotics: Transduction Principles, System Integration, and Robotic Applications

cs.RO ·2026-11-16 ·Hao Wu, Yu Feng, Haotian Guo, Huichan Zhao, Changsheng Wu +1 more
similarity 0.36
Abstract · 35 pages, 9 figures

Non-imaging optical tactile sensors encode contact through changes in optical intensity, wavelength, spectra, or photon counts, offering diverse architectures for robotic touch. Their usefulness depends on whether contact variables can be reliably distinguished from coupled mechanical and environmental effects, and whether the resulting information can be delivered in time to guide action. This review develops a unified framework linking mechanical load transmission, optical encoding, readout, and tactile inference to robotic task requirements. It examines reflective and waveguide-based devices, micro/nanofibers, fiber gratings, interferometric and resonant structures, and mechanoluminescent composites. Three considerations emerge across these approaches. First, high optical sensitivity supports accurate tactile estimation only when target variables remain identifiable under the relevant contact and calibration conditions. Second, spatial coverage and feedback timing must be assessed at the system level, accounting for multiplexing, acquisition, demodulation, and inference. Third, device characterization, offline recognition, and closed-loop robotic performance provide distinct levels of evidence and require different evaluation criteria. Representative studies illustrate how these considerations shape force estimation, contact localization, slip correction and distributed interaction. This review concludes with priorities for calibration transfer, reliable interfaces, scalable readout, and task-based validation, providing a basis for selecting and developing non-imaging optical tactile architectures for robotics.

0.16

WAVES: Wearable Active Vibroacoustic Elasticity Sensing for Low-Cost and Non-Invasive Muscle Stiffness Monitoring

cs.ET ·2026-11-04 ·Shubham Rohal, Dong Yoon Lee, Shijia Pan
similarity 0.36
Abstract

Muscle stiffness is a physiologically meaningful biomarker associated with a wide range of musculoskeletal and neurological conditions. However, existing muscle stiffness assessment methods, such as shear wave elastography (SWE), manual palpation, and handheld mechanical probes, remain impractical for continuous, everyday monitoring due to bulky hardware, operator dependence, and limited self-use. Meanwhile, wearable muscle-sensing modalities such as Electromyography (EMG) and Mechanomyography (MMG) primarily capture muscle activation rather than passive mechanical properties of tissue at rest, leaving a critical gap in portable monitoring of resting muscle stiffness. In this work, we present WAVES, a wearable system for continuous monitoring of muscle stiffness via active vibroacoustic sensing. WAVES injects controlled vibroacoustic excitation into soft tissue and estimates muscle stiffness by measuring shear-wave propagation velocity through Time-Difference-of-Arrival (TDoA) analysis across spatially distributed wearable sensors. To achieve accurate TDoA estimation with low-cost wearable hardware, we develop a physiology- and quality-guided vibroacoustic sensing framework that effectively screens and refines TDoA for accurate stiffness estimation. We evaluate WAVES through characterization experiments using ballistic jelly and end-to-end on-body evaluation with human participants. Results demonstrate that WAVES can robustly estimate muscle stiffness across multiple users and different superficial muscles while enabling lightweight, wearable deployment for everyday use. WAVES is able to achieve a muscle stiffness estimation error of 13.1% or less across multiple users and multiple muscle groups.

0.25