CS Paper Radar

Plug-in Estimation Method for Topology and Admittance Estimation in Electric Grids

Norak Rin, Iman Shames, Ian R. Petersen, Nanduni I. Nimalsiri, Elizabeth L. Ratnam

eess.SY ·submitted 2026-10-21 20:46 UTC · v1
benchmark

Abstract

This paper proposes a scalable method for topology and admittance estimation in electric power grids. Our proposed plug-in estimation method incorporates precise phasor measurement unit data to estimate planned or unplanned grid topology and admittance parameter changes. Our plug-in estimation method decouples the problem into two stages: (i) constructing and averaging voltage coefficient matrices and current vectors from phasor data, and (ii) estimating admittance parameters via a least-squares regression approach with thresholding to recover the network topology. Rigidity matrix theory underpins the design of our plug-in estimation method --- to determine the data requirements (e.g., necessary and sufficient conditions) for accurate estimation of the grid topology and admittance parameters. By means of numerical simulations on the IEEE 13-node, 123-node, and European low voltage test feeders, we demonstrate the scalability of our plug-in estimation method and benchmark the computational time against a structured total least squares method. Our simulation results highlight the practicality of the proposed method for topology and admittance estimation in large-scale electric networks, including electric grids with partial topology information.

Closest papers

Nearest neighbours by meaning across the whole index.

Topology-adaptive Estimation of Maximum Voltage Unbalance for Distribution Networks with Finite-sample Guarantee

eess.SY ·2026-10-14 ·Jinbao Wang, Jun Liu, Shiliang Zhang, Xuehui Ma, He Zhang
similarity 0.58
Abstract

High penetration of single-phase distributed power production and frequent topology changes can significantly increase voltage unbalance in distribution networks. Reliable probabilistic power flow (PPF) assessment for the network, therefore, must account for topology-dependent power-flow equations, numerical error in the voltage unbalance factor (VUF), and finite-sample uncertainty in power measurements. In this paper, we propose Topology-Adaptive Certified Quantile Estimation (TACQE) to estimate the maximum VUF across monitored electric buses. Following a local network change, TACQE updates the cross-couplings among power-flow sequences, and certifies candidate PPF solutions against the updated nonlinear equations. The resulted power-flow state enclosures provide rigorous bounds on the maximum VUF. Furthermore, we derive independent reference-solver evaluations to calibrate discrepancies from the reference PPF solution. This leads to a uniform sampling bound that yields simultaneous upper-tail probabilities and quantiles, which provides a finite-sample guarantee for the estimated maximum-VUF distribution over an entire range of VUF thresholds. From our numerical simulations across 101 fixed-topology quantiles, it demonstrates that the designed TACQE can provide a fast candidate post-change power flow solution where it reuses most of the previous network model and modifies only the affected bus blocks.

0.17

Limitations of RMS-based Stability Assessment of Converter-based Grids: A Case Study

eess.SY ·2026-08-19 ·Pol Jane-Soneira, Ognjen Stanojev, Francisco Canales Perez, Qian Long, Mario Schweizer +1 more
similarity 0.56
Abstract

The increasing penetration of power electronic converters in industrial grids introduces stability challenges at frequencies well above the electromechanical range of traditional power systems. Commercial software tools typically perform eigenvalue-based stability analysis using root-mean-square (RMS) models that assume a quasi-stationary network, thereby neglecting electromagnetic dynamics of assets --- which is standard practice in power system analysis. This paper presents a case study of an industrial grid where the conventional RMS-based eigenvalue analysis predicts stable operation, while a detailed electromagnetic transient (EMT) simulation reveals growing oscillations, indicating instability. To bridge this gap, we introduce an alternative modeling approach that formulates the network dynamics in the rotating $dq$ reference frame, retaining the differential equations of electromagnetic dynamics. The resulting model enables eigenvalue analysis that correctly identifies the unstable modes, consistent with the EMT simulation results. Our findings highlight a fundamental limitation of RMS-based stability assessment for converter-dominated grids and demonstrate that dynamic impedance models in the dq frame provide a viable path toward accurate small-signal analysis encompassing high-frequency converter-network interactions.

0.32

Sparse Generalized-Admittance AC Power Flow for Fast Contingency Analysis and Remedial-Action Assessment

eess.SY ·2026-09-12 ·Pierre Artoisenet, Noémie Verstraete
similarity 0.56
Abstract · 8 pages, 1 figure

Repeated AC power-flow calculations are common tasks in transmission system operations, in particular for contingency analysis and remedial-action assessment. For large networks, their cumulative runtime can become a computational bottleneck in operational processes. This paper develops a sparse reformulation of the generalized bus-admittance power-flow method known as PFPD. Loads and generators are represented by fixed shunt admittance terms on the diagonal of the admittance matrix, while corrective nodal currents are iteratively computed to match the constant-power and regulated-voltage constraints. In contrast to the original formulation, the slack bus is treated as a fixed-voltage boundary and removed from the admittance block decomposition. The resulting iteration reuses sparse LU factorizations of the initial generalized non-slack matrix and its PQ block, without explicitly forming dense inverse matrices. The same formulation admits two initialization modes: an unsolved base case using the same flat-start shunt heuristic as in the primary PFPD method, and repeated post-action calculations initialized from a solved operating point. Localized topology and parameter changes are expressed as low-rank admittance updates and the resulting admittance matrices are inverted by means of the Woodbury identity. An optional local-network formulation can provide an warm start before full-network refinement. N-1 experiments on the 1354-bus and 9241-bus PEGASE systems and the 6717-bus synthetic Texas system yield average per-contingency speedups between 14.4 and 18.0 relative to pandapower. On transformer tap-position actions, the method is 2.8--2.9 times faster than pandapower and 7.2--29.9 times faster than PowSyBl OpenLoadFlow.

0.34

Reinsertion-Aware Parameter Estimation of the WECC Composite Load Model via Closed-Loop Equivalent-Network Co-Estimation

eess.SY ·2026-10-25 ·Jong Ha Woo, Victor Daldegan Paduani, Zishuo Yang, Yu Ma, Qi Xiao +1 more
benchmark similarity 0.53
Abstract · 10 pages, 10 figures, 7 tables. Submitted to IEEE Transactions on Power Systems

Measurement-based parameter estimation of the WECC composite load model (CMLD) commonly relies on voltage replay, where measured voltage is imposed on an isolated CMLD and its parameters are optimized to reproduce measured active and reactive power. However, this open-loop formulation neglects the two-way dynamic interaction between the load and grid, potentially causing large errors when the estimated model is reinserted into dynamic grid simulations. To address this limitation, we propose a closed-loop parameter estimation framework that alternately estimates the CMLD parameters and a five-parameter equivalent network representing the external grid. This framework restores load-grid interaction during estimation and enables voltage, active power, and reactive power to jointly constrain the parameter estimation. Compared with four baseline methods, the proposed approach achieves the highest reinsertion accuracy in both the CMLD benchmark and transmission and distribution (T&D) co-simulation environments. In the T&D case, it reduces active-power, reactive-power, and voltage errors by 73%, 64%, and 62%, respectively. The identified model also maintains improved reinsertion accuracy under disturbances not used for estimation, demonstrating transferability beyond the identification event.

0.47

A Multi-Stage Linear Programming Framework for Three-Phase State Estimation in Low-Voltage Distribution Grids

eess.SY ·2026-09-24 ·Mohsen Banaei, Eghbal Hosseini, Ahlam Jameel, Konstantin Filonenko, Shahrzad Pour +1 more
published similarity 0.50
Abstract · Presented at the International Energy Future Conference, 2025, Rome

Low-voltage (LV) distribution feeders are increasingly difficult to monitor because real-time load data are unavailable, historical measurements are sparsely sampled, and high-rate voltage sensors cover only a few nodes. This paper proposes a multi-stage linear programming (MSLP) estimator for three-phase unbalanced LV grids that reconstructs per-phase nodal voltages under such limited observability. The estimator linearises the three-phase power flow through voltage-to-power sensitivity matrices and adjusts the nodal active and reactive power injections so that the resulting voltages match the available measurements. To limit the error introduced by linearisation, the sensitivities are rebuilt and the power corrections refined over successive iterations, and power-balance constraints at intermediate metered nodes are added to tighten the feasible region. The method is validated on a real 50-node Danish LV feeder, where it attains a mean absolute error of 0.641V, a standard deviation of 0.816V, a root-mean-square error of 0.842~V, and a maximum error of 3.437V. Compared with a single-stage linear estimator, MSLP lowers the error metrics by roughly 16 percent on average, and additional studies quantify the influence of the input-preparation strategy and of the number of estimation meters.

0.32

Unifying Power Flow and Electromagnetic Transient Modeling

eess.SY ·2026-09-08 ·Tina Gao, Aayushya Agarwala, Timothy McNamara, Lawrence Pileggi
similarity 0.50
Abstract

Grid tools are separated by timescales: steady-state analysis is performed by power flow (PF), whereas the fastest dynamics are captured by electromagnetic transient (EMT) simulation. Although operating at varying timescales, different tools should produce consistent results when analyzing the same grid conditions. However, the PF steady-state solution does not match the time-to-infinity EMT response. This mismatch exists because simplified device models in PF are inconsistent with the "ground truth" EMT models derived from first principles. As inverter-based resources (IBRs) and data centers strip away inertia and operating reserves, approximations used in PF risk grid security by missing violations. To address this, we introduce a steady-state framework that uses full-physics EMT models for high-fidelity steady-state grid analysis. The challenge lies in systematically formulating algebraic frequency-domain representations of dynamic power devices that are naturally described in state-space form. Our tool, SALT (Steady-state After Last Transients), constructs steady-state representations that exactly capture grid device physics when embedded into transmission networks. The approach exploits the structural properties of power device models and the single-harmonic, balanced nature of the transmission system. Results demonstrate SALT achieves EMT steady-state accuracy while delivering a 1x10^6 times speedup. We demonstrate that SALT can capture security threats in contingency scenarios without exception --- whereas PF-based analyses reported 75% fewer rated line violations, 18% fewer Q-limit violations, and 7% fewer voltage violations.

0.20

Co-Optimization of Network Topology and Variable Impedance Devices under Dynamic Line Ratings Using Iterative McCormick Relaxation

eess.SY ·2026-10-27 ·Junseon Park, Hyeongon Park, Rahul K. gupta
benchmark similarity 0.50
Abstract

Grid Enhancing Technologies (GETs), such as Network Topology Optimization (NTO), Dynamic Line Rating (DLR), and Variable Impedance Devices (VIDs) are increasingly deployed in power transmission grids to address congestion and improve grid utilization. However, their growing adoption necessitates coordinated operation to fully exploit their benefits. This paper presents a unified co-optimization framework that integrates NTO, DLR, and VID to alleviate congestion and minimize operational costs. NTO is modeled using a node-breaker formulation to provide enhanced switching granularity, while DLR incorporates weather-dependent parameters, including wind speed and ambient temperature, to dynamically adjust transmission limits. The resulting formulation is a mixed-integer nonlinear program due to power flow constraints with bilinear VID terms, and discrete topology decisions. To improve tractability, we propose using a McCormick relaxation approach to linearize bilinear terms. Furthermore, we propose an iterative refinement of the McCormick relaxation scheme to enhance solution accuracy. The proposed framework is validated through detailed analyses on the IEEE 118-bus system, along with additional case studies on other benchmark systems to assess scalability. Results demonstrate that the proposed approach improves solution accuracy compared to standard McCormick relaxation, achieves solution quality close to the nonlinear formulation, and maintains computational efficiency.

0.29

Efficient Quantile-Resolved Hosting Capacity Assessment on Nodal Level for Low-Voltage Grids

eess.SY ·2026-09-08 ·Maximilian Köhler, Edwin Mora, Mathias Duckheim, Stefan Niessen
similarity 0.50
Abstract · Submitted to IEEE PES ISGT Europe 2026. 5 pages, 3 figures. Keywords: Hosting Capacity, Uncertainty, Distribution Grid, Distributed Energy R…

Hosting capacity - the maximum additional capacity a network can accommodate without violating operational limits - is a key metric in distribution system planning and operation. Decisions on grid reinforcements and the deployment of flexibility management require not only the worst-case HC but also an understanding of the distribution of HC under different likelihoods in load and generation patterns. Quantile-resolved HC distributions provide this view by expressing HC as a function of an acceptable operational limit exceedance likelihood. Monte Carlo sampling is the established approach for computing such distributions but demands large computational resources. Approximations sacrifice either accuracy, the ability to capture uncertainty correlations, or scalability when assessing real-world networks. This paper introduces a computationally efficient method for calculating distributions for quantile-resolved HC. It uses a representation of load samples as multivariate normal distribution, propagated through a linearized power flow model. This allows for leveraging a re-parametrized AC-OPF problem for each hosting capacity quantile. Benchmarking against Monte Carlo-based methods on realistic LV networks demonstrates that the proposed method achieves comparable accuracy with a mean deviation of approx. 3%, while reducing computational time by orders of magnitude. For the exemplary networks the computational time decreases from 11 min to 2 s, and 38 h to 50 s, respectively. The method's scalability is also suitable for recalculation in 15-minute cycles encountered in DSO practice for e.g., real-time grid management.

0.21