CS Paper Radar

Measurement-Based Assessment of Decadal Inertia and Primary Frequency Response Trends in the US Eastern Interconnection

Saurav Dulal, Mark Baldwin, Narges Ghiasi, Mohammed Olama, Ali R. Ekti, Nils M. Stenvig, Yilu Liu

eess.SY ·submitted 2026-10-30 17:30 UTC · v1

Abstract

Changes in the generation mix of the U.S. Eastern Interconnection (EI) raise questions about long-term frequency performance, particularly inertia and primary frequency response (PFR). This paper jointly examines these characteristics using synchronized FNET/GridEye frequency measurements and confirmed generation-trip events from 2013 to 2025. A representative EI frequency trajectory is constructed using the median of geographically distributed measurements. Effective inertia is estimated quarterly from the early post-disturbance rate of change of frequency (RoCoF), using a 3-second window and least-squares fitting. PFR is evaluated using the beta metric, which measures aggregate frequency response from disturbance size and the A-to-B frequency deviation. Annual beta estimates are obtained after filtering events by starting frequency and disturbance size to improve comparability across years. Results show that EI effective inertia varies seasonally and follows a non-monotonic trend rather than a uniform long-term decline. Over the same period, coal generation decreased while natural gas, wind, and solar generation increased. Changes in synchronous generator commitment and operating conditions may have offset some expected inertia reductions. Filtered beta generally increased from the mid-2010s to the early 2020s, with year-to-year variability thereafter. The different trends show that early inertial behavior and broader aggregate frequency response have not evolved in parallel. Joint analysis of inertia and beta offers a more complete measurement-based assessment of EI frequency performance during the generation transition.

Comment
Presented in CIGRE 2026 Grid of the Future Symposium.The paper has 12 pages and 6 figures in total

Closest papers

Nearest neighbours by meaning across the whole index.

Frequency Measurement Practices for Inertia Assessment in Inverter Based Resources Dominated Power Systems

eess.SY ·2026-09-28 ·Christos M. Nikolakakos, Hassan Haes Alhelou, Nikos Hatziargyriou
similarity 0.62
Abstract · Under Review in IEEE Transactions on Power Systems

Transmission system operators and protective relays compute the rate of change of frequency (RoCoF) from frequency averaged over tens to hundreds of milliseconds, as standards and grid codes specify. Any response delivered inside that window lowers the measured RoCoF, so the inferred inertia depends on the window and the responses in service. This paper defines the windowed inertia estimate and derives an exact identity the system inertia divided by one minus the fraction of the disturbance energy delivered inside the window and a closed-form prediction that applies the same estimator to the trajectory of a linear response model. Eleven IEEE 9-bus RMS runs synchronous, grid-following and grid-forming configurations, disturbance sizes and parameter sweeps are reproduced by that model, and the identity closes on the measured response powers. Fast frequency response inflates the estimate most: at 500 ms a grid-following system with 20 % less synchronous inertia reports the same value as the all-synchronous system, the grid-forming system a higher one. On a reduced Greek transmission system the 500ms estimate exceeds the inertia by 17-26%, and a scenario with 10% less synchronous inertia reports more than the all-synchronous scenario's inertia. Operators can thus compute what their measurement reports.

0.26

Beyond Scalar Inertia: Frequency-Response-Based Assessment of Finite-Duration Inertial Support in Grid-Forming Converters

eess.SY ·2026-11-13 ·Ziqi Zhou, Mahdieh S. Sadabadi, Sante Pugliese, Xiaoqiang Li, Xiaojie Wu +1 more
hot direction similarity 0.59
Abstract · This paper has 6 pages with 5 figures. The target journal will be determined at a later stage

Conventional scalar inertia characterizes only the low-frequency terminal behavior of grid-forming converters (GFMs) and cannot fully predict inertial energy delivery during short-duration frequency disturbances. This letter proposes a frequency-response-based method to assess finite-duration inertial support using complex terminal power--frequency responses, such as those provided by Network Frequency Perturbation (NFP) plots. For GFMs with nonzero steady-state droop, a duration-dependent energy-equivalent inertia is defined after subtracting the ideal static-droop contribution. An exact spectral relationship is established, expressing this metric as a duration-weighted integral of frequency-dependent inertia, without requiring knowledge of the internal controller structure and parameters. The duration dependence of the metric is further shown to encode observable oscillation frequencies and damping ratios. A coefficient-decoupling GFM control with identical scalar inertia and droop across different settings is used for verification.

0.27

On PMU Adequacy for Wideband Dynamics Tracking Beyond Attenuation Assumptions

eess.SP ·2026-11-06 ·Chetan Mishra, Luigi Vanfretti, Jaime Delaree Jr. and, Kevin D. Jones
similarity 0.51
Abstract

Recent work highlights the inadequacy of standard synchrophasors in capturing high-frequency grid dynamics, including data center oscillations, primarily due to filtering and windowing attenuation during phasor estimation. This letter shows how synchrophasor ambient data spectrum itself contains information on attenuation, which provides a way to identify critically impacted measurements and potentially estimate and undo the effect. Results are shown for synthetic data as well as actual synchrophasor estimates from digital fault recorders (DFRs) within the Dominion Energy system.

0.14

Enhancing Transient Stability of VSG-Controlled Converters Under Grid Frequency Disturbances

eess.SY ·2026-11-13 ·B. Li, Y. Zhang, X. Wang, S. Yang, Z. Hao +1 more
similarity 0.50
Abstract

Strong damping feedback can substantially improve the transient synchronization stability of renewable energy converters employing virtual synchronous generator (VSG) control. However, conventional damping feedback uses the nominal frequency as its reference. When the frequency of a weak grid deviates from nominal, strong damping tends to keep the VSG frequency near nominal. This can sustain a frequency difference between the VSG and the grid and compromise transient synchronization. To address this problem, this paper proposes a complex-frequency-based method to estimate the grid reference frequency from local terminal measurements. The estimated frequency replaces the nominal reference in the VSG synchronization loop, so that damping acts on the frequency difference between the VSG and the real grid. Controller hardware-in-the-loop tests validate the effectiveness of the proposed method under grid frequency disturbances and its robustness to grid parameter uncertainty and adverse grid conditions.

0.26

Regional Frequency Constrained Dispatch Method Considering Spatial-joint Stochastic Disturbances and Contingencies

eess.SY ·2026-09-04 ·Nian Liu, Yubing Chen, Kai Jiang, Jiahao Liu, Cheng Wang +1 more
similarity 0.50
Abstract

The increasing penetration of renewable energy challenges frequency stability due to high variability and declining inertia. Traditional frequency security constrained dispatch methods fail to capture regional frequency heterogeneity and spatially correlated stochastic disturbances, resulting in inaccurate frequency security enforcement. To address this, a regional frequency constrained dispatch method is proposed, considering the spatially joint stochastic disturbances and contingencies. Firstly, a multi-regional frequency response model is constructed, incorporating the Vine-Copula based characterization of regional stochastic disturbances and regional frequency support. Then, a progressive latent-bottleneck physics-informed neural network is applied to characterize differential frequency nadir terms and regional frequency support integral terms via an encoder-decoder architecture, which enables optimization compatible expressions of system frequency dynamics. Finally, a day ahead dispatch model is developed in which regional stochastic frequency constraints are embedded using a CVaR-based formulation. A case study on the IEEE 118-bus system shows that the proposed method outperforms the unified center of inertia embedded approach in mitigating regional frequency violations, with the regional frequency nadir and RoCoF improved by 32.76% and 2.06%, respectively.

0.32

Reconstructing Boundary Layer Wind Profiles with Machine Learning: A Comparative Study on IGRA Radiosonde Data

cs.LG cs.NEphysics.ao-ph ·2026-11-09 ·Fedor Buzaev, Dmitry Efremenko, Daria Pugacheva, Fedor Ratnikov, Egor Bugaev +2 more
publishedbenchmark similarity 0.47
Abstract · 10 pages, 8 figures. Accepted at the 2nd Workshop on AI-Ready Data for Science Discovery (ADSD), IEEE ICDM 2026

Wind profiles in the atmospheric boundary layer (ABL) drive short-range forecasting and wind-energy siting, yet sparse radiosonde coverage forces practitioners to interpolate them from a handful of physical predictors. We benchmark modern tabular learners against analytical parameterizations on 158,097 IGRA soundings. CatBoost, TabM, and FT-Transformer reduce RMSE to 1.3-1.6 m/s, against approximately 3 m/s for power-law and Monin-Obukhov fits; once the predictor set is fixed the three architectures differ by less than 0.05 m/s, so accuracy is driven by predictors rather than architecture. A cohort analysis of within-bin profile dispersion places an empirical floor of approximately 1.77 m/s on any point-wise predictor that uses standard radiosonde features, consistent with prior eddy-viscosity inversions. A one-dimensional Fourier Neural Operator applied as a post-hoc corrector to frozen tabular predictions reduces near-surface RMSE on U.S. stations from 1.5 to 1.2 m/s, while leaving upper-layer error unchanged. Further gains should come from new predictors rather than larger models.

0.28

Quantifying Power to Voltage and Frequency Dynamics for Oscillation Propagation Assessment

eess.SY ·2026-09-03 ·Onur Alican, Dionysios Moutevelis, Marc Cheah-Mañe, Oriol Gomis-Bellmunt, Eduardo Prieto-Araujo
benchmark similarity 0.46
Abstract

The integration of Inverter-Based Resources (IBRs) into power systems introduces multi-timescale dynamics and oscillations which may propagate to distant areas and endanger the safe system operation. These oscillations pose a significant challenge as their source, frequency, and propagation pathways are often challenging to identify in large interconnected systems, comprising numerous synchronous machines and IBRs. For the above reasons, analytical tools that identify the sensitivity of the system to oscillations within a large frequency spectrum, affecting both voltage and frequency variables across various network locations, are of interest. This paper addresses this topic by introducing a frequency-domain framework based on linear analysis, which characterizes the sensitivity to oscillations of each network bus voltage and of each generation unit frequency. Within this framework, two quantitative indicators are proposed, namely the Frequency Sensitivity Index (FSI) and Voltage Sensitivity Index (VSI). These indexes are derived analytically from the transfer functions which relate the active and reactive power injections to each bus with the voltage and frequency variables across the network, derived from the linear Electromagnetic Transient (EMT) power system model. The proposed indices quantify the sensitivity of the system to oscillations of different type and frequency, providing insights for both oscillation detection and propagation analysis. The methodology is applied to a case study based on the modified IEEE 68-bus benchmark system under partial and full IBR penetration, while its accuracy is validated through EMT time-domain simulations using linear and nonlinear models developed in Matlab/Simulink environment.

0.29

Evaluating Grid Strength with Rising Penetration of Inverter Based Resources

eess.SY ·2026-09-22 ·Mohammed N. Khamees, Gad Ilunga, Zhongxia Zhang, Richard E. Tuck
published similarity 0.46
Abstract · Accepted for publication in 2026 CIGRE USNC Grid of the Future (GOTF) Symposium

Over the years, Dominion Energy Virginia (DEV) has experienced recurring power quality disturbances, including voltage and power oscillations, particularly in areas with significant inverter-based generation. While these phenomena suggest a potential relationship to system strength, no definitive correlation has yet been established. This paper presents methodologies for assessing system strength across the DEV network and identifying regions that may be vulnerable to such disturbances. To this end, three grid-strength metrics are evaluated: the Simple Short-Circuit Ratio (SSCR), the Weighted Short-Circuit Ratio (WSCR), and the Composite Short-Circuit Ratio (CSCR). Historical event data will be analyzed using steady-state snapshots from DEV's proprietary Analysis on Demand (ANODE) platform, which provides 10-minute interval load-flow data. These snapshots will be processed using a developed software tool to compute system strength metrics. The analysis will investigate potential correlations between system strength and observed disturbances. Where such correlations are identified, the study will further evaluate the impact of deploying synchronous condensers (SynCons) as a mitigation strategy.

0.31