Conflict-Aware Impedance-Sensitivity-Based Tuning for Multi-Mode Damping Enhancement

Quang Manh Hoang, Xuan Thanh Trinh, Sina Zarrabian, Akhtar Hussain, Van-Hai Bui

eess.SY ·submitted 2026-11-04 04:22 UTC · v1

Abstract

Impedance-based eigenvalue sensitivity provides a practical way to relate converter parameters to poorly damped system modes, but tuning becomes nontrivial when one parameter improves one target mode while degrading another. This paper introduces a conflict-aware tuning strategy for simultaneous damping enhancement of multiple modes. The method converts impedance-derived eigenvalue sensitivities into normalized damping-ratio sensitivities, diagnoses opposing modal tuning directions, and selects either one parameter or a coordinated pair at each iteration. A low-dimensional max--min problem maximizes the predicted damping of the worst target mode subject to parameter limits, protected-mode constraints, and implementation-specific feasibility requirements. Each accepted update is verified on the full system model and the sensitivities are recomputed. Studies on a four-bus system and a modified IEEE 14-bus system demonstrate the value of pairwise coordination, including a case in which single-parameter tuning stops before the predefined damping target is reached.

Comment
Manuscript is submitted to PESGM2027

Closest papers

Nearest neighbours by meaning across the whole index.

A New Index for Quantifying Stability Adaptation Effort in Power Electronics-Dominated Power Systems Based on Frequency-Domain Impedance Identification

eess.SY ·2026-10-02 ·Luis A. Garcia-Reyes, Macarena Martin-Almenta, Edgar Nuño-Martínez, Javier Renedo, Antonio Cordón-Rodríguez +2 more
published similarity 0.53
Abstract · Paper in Proceedings of CIGRE Paris Session, C4-PS1, Paper ID 11553

The increasing use of converter based resources has made stability assessment in modern power systems more challenging, particularly because many devices are available only as black box models. Conventional eigenvalue based methods require full dynamic representations, while frequency domain impedance techniques based on the Generalized Nyquist Criterion (GNC) provide stability insight but do not quantify how much a converter must be retuned to restore stability. This paper introduces the Adaptation Effort Index (AEI), a metric that measures the sensitivity of dominant modes to parameter variations and quantifies the effort required for a converter to reconfigure itself under unstable operating conditions. The AEI combines the Nyquist Stability Margin obtained from frequency domain screening with a modal sensitivity index derived from fitted state space models synthesized from black box impedance data. The method is applied to a system comprising a grid forming and a grid following converter. Results show that, although both units can be tuned to stabilize the system, the grid following converter requires significantly less adaptation effort. The AEI therefore provides a practical and model agnostic tool for identifying which converter should be reconfigured in converter dominated grids, offering valuable guidance for system operators and manufacturers.

0.30

Hyperscale Data Centers as Wide-Area Damping Actuators for Low-Inertia Power Systems

eess.SY ·2026-10-24 ·Mohamed Shamseldein
publishedbenchmark similarity 0.52
Abstract · 24 pages, 7 figures. Author manuscript of the published journal article

Low-inertia power systems need fast damping actuators as synchronous generation is displaced by inverter-based resources. This paper evaluates hyperscale data-center loads controlled through Dynamic Voltage and Frequency Scaling (DVFS) as wide-area damping actuators. A DAE-consistent bus-input matrix is validated against the ANDES reduced state matrix and a finite-difference input check. On the Kundur two-area benchmark, Bus 10 ranks highest among non-generator buses for the 0.647 Hz inter-area mode. A classical washout-plus-lead-lag controller raises damping from 3.43% to approximately 6%. Modern 10-50 ms battery and DVFS actuators require comparable peak modulation for the same small-signal damping target. Compared with a closest same-system data-center-frequency-droop baseline, the wide-area controller offers a clearer advantage: at comparable peak MW, droop reaches 4.76% damping, while reaching 6% requires approximately twice the peak modulation. In the Pade-delay model, damping crosses the open-loop value at 443 ms for the 10 ms DVFS actuator versus 374 ms for the 50 ms BESS case. Reduced-order saturation stress tests show that a 2 MW envelope is non-binding for modal, fault-cleared-equivalent, and line-outage-equivalent disturbances, but can bind under generator-trip-equivalent stress. IEEE 39-bus tests confirm the DAE-based ranking procedure and show that high-residue buses may require more phase compensation than a single lead-lag stage can supply.

0.37

Adaptive Grid-Mode-Aware Hybrid Energy Storage Control for AI Data Center Oscillation Mitigation

eess.SY ·2026-11-04 ·Quang Manh Hoang, Sina Mohammadi, Phi Long Nguyen, Wencong Su, Van-Hai Bui
similarity 0.52
Abstract · Manuscript is submitted to PESGM2027

Oscillatory power components in AI data-center demand can produce large frequency deviations when they coincide with vulnerable grid modes. Mode-aware hybrid energy storage systems (HESSs) can selectively suppress these components, but their effectiveness degrades when the grid mode changes while the control target remains fixed. This paper proposes a closed-loop grid-mode-adaptive HESS control framework that integrates measurement-based modal identification with mode-selective control. A sliding-window N4SID estimator identifies the local grid dynamics from grid-side power and frequency measurements, and the resulting natural-frequency estimate is used to retune the modal suppression branch assigned to the supercapacitor. The framework is evaluated under a grid-mode shift from 0.50 to 1.35Hz while maintaining equal physical damping and approximately equal load excitation at both frequencies. Compared with the fixed-target controller, the adaptive method reduces the post-change grid-side modal power component from 8.78 to 2.02MW, corresponding to a 76.94% reduction, and substantially lowers the resulting frequency deviation.

0.21

Reduced-Order Model Characterization of Nonlinear Sustained Oscillations

eess.SY math.DS ·2026-09-27 ·Kaiyang Huang, Dan Wilson, Kai Sun
similarity 0.49
Abstract

Nonlinear sustained oscillations involving inverter-based resources can happen when device and network interactions produce an attracting limit cycle around an unstable equilibrium. A damping controller must then describe nonlinear dynamics over the region between the two invariant sets, where a local equilibrium linearization can be insufficient. In this paper, a controlled phase--isostable model is first developed on a two-dimensional invariant manifold connecting the equilibrium and the limit cycle. Dynamics on this surface are represented by phase and isostable coordinates, while physical states and control inputs are related to these coordinates through nonlinear reconstruction and response functions. The required functions are computed from connecting trajectories and periodic-orbit data. A control strategy is then designed to provide extra damping while limiting phase distortion. Case studies on a two-area system and an IEEE 39-bus system demonstrate more effective oscillation damping than the compared equilibrium-linearized designs under the same conditions.

0.27

Co-designing a Layered Control Architecture

eess.SY math.OC ·2026-10-14 ·Chris Verhoek, Charis Stamouli, George J. Pappas, Nikolai Matni
similarity 0.49
Abstract · 19 pages, extended version

Layered control architectures (LCAs) are ubiquitous in complex engineering systems. However, in practice they are largely designed ad hoc and mostly dictated by the experience of the designer. This is because there is currently no systematic and practically applicable theory available to holistically design LCAs. Hence, systematically reasoning about the optimality, stability, and feasibility of the LCA design is not possible. We set a first step toward such a theory by presenting a framework for co-designing a two-layer LCA for a linear time-invariant plant. The resulting co-design problem optimizes over architectural design variables (e.g., reduced order model dimension and sampling ratio between the layers) and tuning-based design variables (e.g., the numerical values of the feedback gain or the matrices of the reduced order model), all subject to constraints that ensure stability, feasibility, and compute properties of the closed-loop LCA. The proposed formulation allows to make informed tradeoffs along the Pareto front traced over different axes of optimality, e.g., speed, accuracy or computational effort. We demonstrate the effect of making various tradeoffs in a simple numerical example.

0.45

Data Center Oscillation Isolation and Grid Support: Fundamental Limits and Source-Selective Control

eess.SY math.DS ·2026-10-19 ·Cheng Feng
similarity 0.49
Abstract

The grid integration of large data centers poses a growing power-system stability challenge. Rapidly varying computing demand can induce oscillations, while the facilities must provide a prescribed response to grid disturbances. Existing controls address load fluctuations and grid support but do not establish their jointly achievable performance. This paper derives fundamental limits and develops a source-selective controller for simultaneous oscillation isolation and grid support. A coupled closed-loop model gives a condition for distinguishing disturbance sources and reveals a direct isolation-support conflict under grid-import-power feedback alone; additional electrical measurements can remove this pointwise conflict but leave a conditional cross-frequency sensitivity limit. Guided by these limits, we design a local residual-feedback storage controller through convex frequency-domain optimization with stability, isolation, and grid-response constraints across operating points. Tests on a single-generator interconnection and a modified nine-bus network show stronger oscillation isolation than equal-order optimized comparators while meeting the prescribed grid response across operating points.

0.22

Guidelines for the implementation of power oscillation damping controllers in power converters

eess.SY ·2026-09-02 ·Javier Renedo, Macarena Martín Almenta, Sergio Martínez Villanueva, Agustín Díaz-García, Antonio Cordón +1 more
similarity 0.49
Abstract

One of the most effective ways to damp electromechanical oscillations in power systems is by means of supplementary controllers attached to the different devices in the power system is by means of power system stabilizers (PSS) in synchronous machines or by means of power oscillation damping (POD) controllers in facilities with power converters. In the recent years, the use of POD controllers in voltage source converters (VSCs) with grid-following (GFL) control has been investigated. Although the potential of POD controllers to help to damp inter-area oscillations in power systems is enormous, their correct implementation is not trivial, because their effectiveness is strongly linked to their settings. This paper provides guidelines for the implementation of POD controllers in power converters for application in real-world power systems. The paper proposes compliance criteria for POD controllers using a synthetic test system and a systematic methodology used in Spanish technical standard for monitoring compliance (NTS), considering practical considerations. The paper also includes numerical examples to illustrate compliance criteria for POD controllers in a synthetic test system. A generic power converter with grid-following (GFL) control is used for the analysis by simulation and POD controllers using modulation of active-power injection (POD-P), reactive-power injection (POD-Q) or both simultaneously (POD-PQ) will be analysed. Results were validated in a large-scale power system. The paper concludes that by using appropriate synthetic systems, methodologies and compliance criteria, POD controllers in power converters could be effective to damp electromechanical oscillation in large-scale power systems.

0.33

Passivity-Guaranteed Variable Impedance and Compliance Control via Online Parameter Optimization

cs.RO eess.SY ·2026-11-07 ·Huseyin Tugcan Dinc, Ersin Daş, Nikolas Thelenberg, Christian Ott
similarity 0.49
Abstract · submitted to Control Engineering Practice

Variable impedance control enhances the interaction capability of robot manipulators by adapting impedance parameters online. However, time-varying impedance parameters may inject energy into the system and violate passivity, particularly when tasks demand rapid stiffness changes. Existing methods address this by increasing damping or limiting the stiffness profile, which often degrades the dynamic response. In this work, we propose a quadratic programming-based parameter optimization framework that guarantees passivity by modulating the desired inertia to compensate for energy injected by stiffness variations, while preserving a critically damped system. For the case of diagonal impedance matrices, we optimize the rates of change of inertia and stiffness subject to a passivity constraint formulated as a convex quadratic program. We extend the framework to compliance control, where the desired inertia is coupled to the robot's configuration-dependent inertia matrix. We use an eigendecomposition based on Cholesky factorization to optimize the spectral weights while maintaining passivity. Experiments on the Kinova Gen3 7-degree-of-freedom manipulator validate both methods with human interaction perturbations. Comparisons with an energy tank approach and a nonpassivity-based method demonstrate that the proposed framework achieves less conservative stiffness tracking without requiring an energy reservoir or damping overhead.

0.23