The one-step surface-air lag in the EnergyPlus zone heat balance: order of accuracy, correction and consequences

Wooyoung Jung

cs.CE ·submitted 2026-11-07 18:19 UTC · v1
unusual

Abstract

The order of accuracy sets how fast numerical error falls as the timestep shortens. This study measured that order for the zone heat balance of EnergyPlus 26.2 against exact or converged references and tested a correction on 45 U.S. Department of Energy prototype cases. All three zone air formulas, the third-order default included, give first order or lower, because the surfaces use the previous timestep's air temperature. Solving surfaces, air and HVAC to agreement within each timestep raises the default to about second order, and in a room with an exact solution two extra passes cut the error eightfold at 1.65 times the runtime. In the prototype cases, the correction changed annual site energy by at most 0.45% but an outpatient clinic's heating by 5.1%. Window-upgrade savings changed by 10% or more in 13 of the 34 applicable cases, about as often as under a change of timestep.

Comment
24 pages, 7 figures, 10 tables. HUBS Lab Paper No. 2026-010. Code and data: doi:10.5281/zenodo.24041718

Closest papers

Nearest neighbours by meaning across the whole index.

Adjacent Heat Transfer Effects Can Bias Savings Estimates When Controlling Only Part of a Multi-Zone Building

eess.SY ·2026-11-12 ·Arash J. Khabbazi, Kevin J. Kircher
publishedtheory similarity 0.62
Abstract · 10 pages. Accepted at the 2027 ASHRAE Winter Conference

Field demonstrations of advanced heating, ventilation, and air-conditioning control often operate a few thermal zones within a larger building and report savings for those zones alone. A recent theorem showed that this practice overestimates whole-building savings, because heat drawn from the neighboring zones is paid for by their equipment and is not counted. The error grows with the thermal conductance between the controlled and uncontrolled zones, with how much colder the controlled zones run over the test, and with the price of the heat their neighbors supply. For one controlled zone with one neighbor, a single thermal price, and slowly changing prices, the relative error reduces to the ratio of two conductances, a screening number that can be evaluated from the two conductances before a demonstration begins. This paper tests how far that reduction can be taken. A two-story house with one thermal zone per floor is simulated over a 90-day heating season in West Lafayette, Indiana, with receding-horizon model predictive control on the first floor and setpoint control on the second, under four combinations of electricity tariff (time-of-use or flat) and heating plant (heat pump or electric resistance). The exact correction from the theorem recovers the true savings in every case, and the full theorem, evaluated from the controlled zone's temperatures, the prices, and the building parameters, reproduces the measured relative error in every case. The conductance ratio bounds that error from above in all four cases, tightly under a flat tariff, within 3%, and loosely under a time-of-use tariff, where most of the controller's savings come from shifting load through the thermal mass rather than from lowering the temperature.

0.30

Data-driven estimation of design heating loads for HVAC equipment sizing

eess.SY ·2026-09-07 ·Alex H. Lee, Elias N. Pergantis, Kevin J. Kircher
similarity 0.48
Abstract

Oversized heating and cooling equipment can unnecessarily increase up-front costs, energy costs, pollutant emissions, and strain on electrical infrastructure. This paper develops two data-driven methods for estimating heating loads at design conditions to improve equipment sizing. One method uses smart thermostat data; the other uses utility bills. We test the methods on a dataset that we gathered from 74 detached single-family houses in five United States climate zones. The dataset includes smart thermostat time-series data, monthly utility bills, weather data, existing equipment specifications, and Manual J design load calculations (the United States industry standard) purchased from practitioners. The two methods have strong goodness-of-fit statistics individually and show fair agreement with each other. On average over the 74 houses, existing heating equipment is 2.75 (2.5th to 97.5th empirical percentile: 1.34-6.52) times larger than the thermostat-method estimate and 2.96 (1.36-7.76 times larger than the bill-method estimate. As implemented by practitioners, the Manual J estimate is 2.26 (0.87-5.21) times larger on average than the thermostat-method estimate and 2.35 (1.02-5.28) times larger than the bill-method estimate. We discuss prospects for implementing the data-driven methods at scale and for incorporating data-driven sizing into industry standards.

0.26

Less is more: error-distance scaling relation for data-efficient kilometer-scale downscaling of extreme heat

cs.LG physics.ao-ph ·2026-09-30 ·Ahmed Marey, Henry Lu, Abhishek Gaur, Sherif Goubran, Malek Aloui +4 more
similarity 0.47
Abstract

Extreme heat is where urban adaptation needs kilometer-scale data the most, but the simulations training a downscaler can cost more than they save, and how much is needed has not been identified. We measured it with CASPER, a U-Net with a structure-preserving loss downscaling 32 km reanalysis to 1 km temperature, humidity and wind, across 24 configurations of one to eight months. Held-out error grows linearly with climatological distance to the training data, RMSE = 0.83 + 2.95 d, explaining 90% of its variance against 7% for volume and predicting unseen months in advance. On held-out extreme summer weeks CASPER preserves the fine-scale structure and cross-variable physics that matched-budget baselines degrade, and matches station observations during documented heat waves to within 1.8 K. Transfer to a new region degrades geographically; 11 days of local simulation cuts Vancouver's held-out error from 3.8 to 1.3 K. Training periods should span the target climate: the same accuracy for four times less simulation, putting kilometer-scale downscaling of extreme heat within reach of groups without large computing facilities.

0.24

Modeling Liquid-Cooled Data Centers in EnergyPlus

eess.SY cs.CEcs.DCcs.LG ·2026-10-23 ·Yun-Dam Ko, Dipashreya A. Sur, Cade Napier, Carlos D. Díaz-Marín, Rishee K. Jain
code/data similarity 0.46
Abstract · 14 pages, 7 figures, 6 tables. Code: https://github.com/Urban-Informatics-Lab/energyplus-liquid-cooling

As AI workloads accelerate data center transition toward high-density racks with direct-to-chip (DTC) liquid cooling, existing simulation tools remain limited in evaluating whole-building and multi-year efficiency. To bridge this gap, we develop a native EnergyPlus object, ElectricEquipment:ITE:LiquidCooled, that models DTC liquid cooling for chilled-water and warm-water architectures as plant-loop components. It couples facility-water loops, rack-side secondary loops, coolant distribution units, and chip-junction temperatures within a single solver. Validation against an independent Modelica implementation across 21 operating conditions, including two full-year runs compared at one-minute resolution, yields loop-temperature RMSE at or below 0.021 K, well within the 0.1 K acceptance threshold. Our case study demonstrates that warm-water liquid cooling reduces annual PUE from 1.43 to 1.25, eliminates on-site water use, and cuts total facility energy by 37.9% relative to an air-cooled baseline. By embedding liquid-cooling logic into EnergyPlus, our work provides whole-building, long-term energy modeling for high-density AI infrastructure within an open-source framework.

0.31

Coupling-Aware Aggregation of Multi-Zone HVAC Loads under Uncertainty: A Two-level Framework

eess.SY ·2026-09-03 ·Jingguan Liu, Han Jiang, Xiaomeng Ai, Shengshi Wang, Xizhen Xue +4 more
top venuehighly cited similarity 0.46
Abstract · Published in: IEEE Transactions on Smart Grid (vol. 17, no. 3, pp. 2077-2091, 2026)

Aggregating building heating, ventilation, and air-conditioning (HVAC) loads unlocks substantial demand-side flexibility for power systems. Yet multi-zone coupling creates intricate interdependencies and uncertainty propagation, complicating the quantification of aggregate flexibility. To address this issue, this paper proposes a coupling-aware two-level aggregation framework. At the building level, tailored Gaussian elimination and coordinate transformation techniques are employed to recast the high-dimensional thermal dynamics as an equivalent lower-dimensional analytical expression. This expression streamlines the subsequent aggregator-level stage by (i) clarifying the propagation of zone-level uncertainties to the building-level interface, (ii) decoupling intra-building multi-zone coupling from inter-building aggregation, and (iii) providing full-dimensional building-level flexibility sets that enable tractable reformulation. At the aggregator level, existing geometric aggregation approaches are generalized by a newly developed matrix-transformation technique. This technique effectively constructs inner approximations between polytopes of different dimensions, producing closed-form images of high-dimensional multi-zone HVAC flexibility in power subspace. The resulting inner approximation is then recast as a customized separatable linear program that efficiently determines the optimal aggregate parameters. Case studies validate the effectiveness of our framework, highlighting its accuracy, reliability, and scalability.

0.60

When Should a Satellite Estimate Be Changed? Stress-Testing Neural Corrections for Evapotranspiration

cs.LG ·2026-09-28 ·Marco Trotta
unusual similarity 0.45
Abstract · 11 pages

Neural residuals can improve satellite evapotranspiration (ET) estimates, but selectors must predict when a correction helps and reject unsupported inputs. We evaluate ten-member models on 16,366 flux-tower observations from 151 stations paired with OpenET, across nine rolling years and five spatial folds. At one held-out station, Gain accepted corrections on all 32 physically invalid records: it predicted a mean benefit of 0.83 mm/day, but the corrections increased mean absolute error by 21.6 mm/day versus OpenET. On spatially held-out unit errors, SupportGain reduced station-macro MAE versus Gain by 0.148 mm/day under wind x3.6 (simultaneous 95% interval, 0.070 to 0.226), with 9.3% acceptance versus Gain's 51.8%; on clean inputs, its 0.006 mm/day advantage had an interval that includes zero. These fault analyses are exploratory; none of 40 preplanned temporal comparisons passed Holm correction, while a separate predeclared cropland contrast found 0.041 mm/day lower station-macro MAE with crop-only training (95% interval, 0.009 to 0.079).

0.28

Heating in human-HVAC interaction for smart homes: An interdisciplinary overview

cs.HC cs.AIcs.SIeess.SY ·2026-09-20 ·Delong Korus-Du, Gunnar Stevens, Alexander Boden, Lenneke Kuijer, Apostolos K. Vavouris +4 more
published similarity 0.45
Abstract

As part of HVAC systems, residential heating provides foundational infrastructure for human habitation in cold weather. However, research on how residents interact with HVAC systems, particularly heating systems, remains fragmented across architecture, engineering, informatics, physiology, psychology, sociology, and design. Based on 541 studies from these fields, this review integrates interdisciplinary research on Heating in Human-HVAC Interaction in smart homes.The resulting synthesis is conceptualized through the Situated Interaction Dynamics of control and feedback between users and systems. User-initiated interactions involve monitoring past and present system performance and planning future operation, while system-initiated interactions rely on sensor networks to trigger automation or provide information enabling user action. These interaction dynamics connect Residents' Experience and Practices with Heating in HVAC System Mechanics. Residents' Experience and Practices include thermal comfort and energy management, where thermal comfort involves both individual physiological and psychological experiences of indoor climate and social practices shaped by norms, empathy, and negotiation among cohabitants. Heating in HVAC System Mechanics includes thermal conditions and energy performance. Thermal conditions concern the regulation of air temperature, mean radiant temperature, air velocity, and relative humidity, while energy performance concerns efficiency and environmental impact. This overview highlights four interdisciplinary tensions: sensed versus lived conditions, personalization versus negotiation, efficiency versus health, and automation versus agency. The resulting framework offers a conceptual lens to interpret heating interactions and design Human-HVAC Interaction that balances IEQ-driven healthy thermal conditions, affordability, and sustainability.

0.43

Carbon reductions through optimized solar heat gain glass properties considering future climate and grid emissions: case study of Chicago's residential buildings

cs.CE ·2026-08-14 ·Yiwei Lyu, Jialiang Xiang, Holly Samuelson
publishedhighly cited similarity 0.44
Abstract · 19 pages, 10 figures. Published in Energy and Buildings 327 (2025) 115080

Existing resources leave confusion over the benefits of high versus low Solar Heat Gain Coefficient (SHGC) windows for energy performance in residential buildings retrofits in cold climates. Additionally, few studies have considered the impact of expected future climate conditions and time-variable grid emission rates on energy-related metrics. Utilizing the ResStock, residential building stock models from the National Renewable Energy Laboratory (NREL), this study investigates retrofits increasing the SHGC of windows in Chicago, a cold US city. The results indicate that increasing window SHGC increases summer cooling needs; however, in most cases, this effect is more than offset by reduced winter heating needs. This balance is particularly beneficial considering the state's expected long-run marginal carbon emission rates. The study also examines the combined effects of high SHGC with improved window insulation values, demonstrating that such strategic window retrofits not only enhance overall building energy performance but also contribute to greater emission reductions. On average, the current Chicago residences (n = 4,826) save 4.6 % on heating and cooling carbon emissions by increasing the SHGC of the windows. If we assume that those homes are upgraded with heat pumps (electrification), a popular retrofit that reduces heating-related carbon emissions in particular, the increased window SHGC saves 2.5 % of long-run marginal carbon emissions. These results provide new insight into the carbon benefits of higher SHGC replacement windows in a cold climate. The benefits are significant, even considering future trends of a warming climate, higher demand grid emissions, and building electrification.

0.68