CS Paper Radar

ExoStack: A Modular and Reconfigurable Software Framework for Wearable Robotics Using ROS 2

Debadrata Sarkar, Upamanyu Ray, Soumen Sen, Aman Arora

cs.RO ·submitted 2026-11-09 12:27 UTC · v1
code/data

Abstract

Wearable robots depend on a software chain that links body-worn sensing to gait interpretation, assistance generation, and actuation. Personalization further requires each measured response to remain associated with the assistance parameters that generated it. This paper presents ExoStack, a modular ROS 2 framework for implementing that chain across embedded hubs and a host computer. Its Embedded Sensing and Actuation (ESA) library configures ESP32 boards as microROS sensing and actuation hubs. ExoCore supplies multi-hub synchronization, gait-event detection, profile generation, motion planning, cost evaluation, and human-in-the-loop (HIL) optimization as configuration-instantiated nodes. The PASE desktop application edits configurations, launches the processing stages, and visualizes ROS 2 topics. Hardware drivers and algorithm plugins can be added through defined interfaces without modifying the generic processing nodes. We characterize hub and planner timing on three embedded computers and demonstrate reuse on two pneumatic exosuits.

Comment
The source code and accompanying documentation website for ExoStack are publicly available at https://github.com/debadrata/ExoStack and https://debadrata.github.io/ExoStack_documentation/, respectively

Closest papers

Nearest neighbours by meaning across the whole index.

OpenZilo: An Open Smart-Ring Platform for Human-Centric Sensing and Interaction with Robots

cs.RO cs.HC ·2026-11-02 ·Qianggang Ding, Xingyao Wang, Rui Feng, Chi Qin, Weijian Lin +5 more
similarity 0.63
Abstract · 17 pages, 5 figures, 8 tables

Wearable robot interfaces must connect user input to timely physical action. We present the proposed platform, an open smart-ring platform for studying this connection across task stages. The ring integrates a microphone, an inertial measurement unit, photoplethysmography, and skin-temperature sensing. Its software architecture separates acquisition, event interpretation, interaction policy, and robot execution. We characterize seven operating modes and evaluate speech and gesture control with 10 participants. Across five commands and 250 trials per modality, speech and gestures achieved task success rates of 90.4% and 88.8%, respectively. Recognition accuracy exceeded task success for both modalities. Gaussian hidden Markov models achieved higher accuracy than a support vector machine across three vocabulary sizes, with longer scoring times. Following a shared spoken task start, gesture-based adjustments had shorter median response times than speech. Whole-task success was 70.0% with gestures and 64.0% with speech. We further examine physiological-event-triggered robot interaction using simulated event notifications. Mean notification-receipt-to-arrival times were 11.71 s for the robot and 9.20 s for an on-site person. These descriptive findings support evaluating wearable robot interfaces through both recognition and physical outcomes, with timing measures appropriate to each task stage.

0.32

OpenRoIS: A Community-Driven Open-Source Middleware Implementing the Robotic Interaction Service (RoIS) Framework for Physical Robots and Virtual Agents

cs.RO cs.HC ·2026-09-18 ·Sebastian Carrera Villalobos, Christopher Nolan Arellano, Arne Hitzmann, Edilson Morais Brito, Akira Utsumi +3 more
code/data similarity 0.60
Abstract · Submitted for presentation at the 2027 IEEE/SICE International Symposium on System Integration (SII), Kobe, Japan

Service applications for human-robot interaction are commonly written against the hardware-specific interfaces of one platform, so a change of hardware forces a rewrite of the application. The Robotic Interaction Service (RoIS) Framework 2.0, standardized by the Object Management Group (OMG), addresses this fragmentation by defining a platform-independent model in which Service Applications interact with Human-Robot Interaction (HRI) Engines through standardized interfaces and hardware-independent symbolic messages. A specification alone, however, does not provide the maintained implementation, Software Development Kits (SDKs), and adapters needed for practical adoption. This paper presents OpenRoIS, a community-driven open-source middleware providing a concrete implementation of the RoIS Framework 2.0. It takes the position that an openly developed, paradigm-neutral implementation is what carries the standard from specification to practice. OpenRoIS contributes a recursive engine architecture in which a single engine class realizes the main and sub HRI Engine roles, an internal five-method component contract distinct from the five external RoIS interfaces, a mapping of those interfaces onto JSON-RPC 2.0 over WebSocket, a single-source-of-truth type pipeline that generates three consistent language stacks, TypeScript and C# client SDKs that include web and Unity support, and a Python adapter SDK that includes ROS 2 support. Through the common RoIS interfaces, a Service Application can address physical robots and virtual agents over the internet. All source code, interface types, and documentation are released under the Apache-2.0 license and openly developed at https://openrois.org/.

0.29

Sensorimotor Stickies: A Reconfigurable On-Body Platform for Closed-Loop Sensorimotor Training

cs.HC ·2026-08-13 ·Tianhong Catherine Yu, Jiwei Zheng, Chi-Jung Lee, Qifeng Yang, Tingyu Cheng +3 more
top venue similarity 0.56
Abstract

Closed-loop sensorimotor training systems can improve learning by sensing movement and delivering real-time feedback, yet most are built as fixed implementations tied to a single task, even though the core technology (inertial and tactile sensing, vibrotactile cueing, rule-based logic) remains the same. We present Sensorimotor Stickies, a reconfigurable on-body platform that treats sensing and vibrotactile feedback as modular stickies that can be patched onto the body as needed. The platform includes miniaturized adhesive modules for IMU sensing, optional tactile sensing, and vibrotactile actuation; low-power firmware and BLE infrastructure for raw streaming and motor control without task-specific rewrites; and a companion mobile app that provides a shared body-centered model for placement, calibration, and feedback authoring. Together, these components enable reconfiguration across training scenarios, user needs, and feedback setups. We evaluate the platform through technical characterization, configured application demonstration, practitioner-mediated configuration sessions, and an end-user study, demonstrating technical feasibility, reconfiguration breadth, and end-user configurability for first-time setup, calibration, and within-task feedback reconfiguration.

0.34

Technical Report of Mobile Manipulator Robot for Industrial Environments

cs.RO cs.CVeess.SY ·2026-11-17 ·Aria Dadnavi, Matin Jamshidi, Kian Khatibi, Shahriar Karimi Makhsous, Saina Najafi Shabestari +6 more
similarity 0.55
Abstract · 25 pages, 22 figures, 4 tables. Technical report of Team Auriga's 2025 mobile manipulator (@Work) platform (Robotics and Intelligent Automat…

This paper presents the design and implementation of Auriga Robotics' mobile manipulator robot, developed at the Robotics and Intelligent Automation Laboratory, Department of Electrical Engineering, Shahid Beheshti University. Hereafter, this platform is referred to as the @Work Robot. The robot targets industrial tasks, with an emphasis on improving efficiency in repetitive or hazardous work environments. It uses a 4-wheel Mecanum drive for omnidirectional movement and a 5-degree-of-freedom manipulator arm with a 3D-printed gripper for object handling and navigation. The electronics consist of custom PCB boards built around ESP32 microcontrollers, together with an NVIDIA Jetson Orin NX that handles high-level processing and real-time system control. On the software side, Hector SLAM provides mapping and localization, A* handles path planning, and YOLO performs real-time object detection. These modules draw on fused sensor data to deliver robust navigation and reliable collision avoidance. Overall, the system shows effective hardware-software integration, with consistent performance in autonomous navigation, object handling, and task execution in industrial-like settings.

0.22

GOLEM: Modular Humanoid Autonomy Towards Electric Vehicle Battery Disassembly

cs.RO ·2026-08-21 ·Max Conway, William Xie, Allen Devaraj, Yutong Zhang, Niraj Pudasaini +12 more
code/data similarity 0.55
Abstract

Disassembling end-of-life electric vehicle (EV) battery packs is dull and dangerous work, performed almost entirely by humans. We present GOLEM (Generalized Open Library of Embodied Modules), an end-to-end, open-source system architecture for EV battery disassembly with the Unitree H1-2 humanoid robot in which walking, manipulation, dynamic stability, navigation, and spatial memory are independent modules with abstract interfaces, so that methods are easily developed, interchanged, and compared. GOLEM is deployed as a Docker-based ROS 2 abstraction in which MuJoCo and IsaacLab digital twins expose interfaces matching the physical robot. GOLEM's composability and per-module customization enable development and demonstration of humanoid EV battery disassembly, from simulation to reality. GOLEM provides fair comparison between humanoid modules, enabling evaluation as a capability ladder, in which one module is characterized at a time and added as a rung: LiDAR-inertial navigation places the robot within 13.0cm of a 6m goal; a learned standing controller recovers from external disturbances that sampling-based lower-body MPC does not; and grasping loosened fasteners from a real Hyundai Ioniq 5 pack degrades from 97% tethered to 87% free-standing to 37% under navigation-induced pose variance. Source code is available at the project page https://golem-humanoid.github.io

0.39

Keeping the Franka Emika Panda alive: a ROS 2 stack with a reliable position interface

cs.RO ·2026-08-20 ·Antonio Langella, Davide Risi, Vincenzo Petrone, Enrico Ferrentino, Pasquale Chiacchio
publishedcode/datahot direction similarity 0.55
Abstract · 12 pages, 10 figures

This paper presents an open-source software stack that restores ROS 2 support for the Franka Emika Panda robot while resolving the long-standing unreliability of its external position control interface. We first analyze the root causes of unstable position control and show that the observed vibrations and protective stops arise from the timing of the external control loop and sampling jitter, rather than from limitations of the robot itself. Building on this analysis, we introduce an asynchronous hardware interface that decouples real-time communication from the ROS 2 control loop, a rate-matching mechanism for slower command sources, and a position-domain reference generation strategy that produces reliable, smooth position commands. Experimental validation shows that the proposed architecture reliably tracks velocity references by reducing motion artifacts introduced by the official implementation, and the stack is validated across motion planning, compliance control, position-controlled manipulation, and haptic teleoperation on two independent Panda platforms. By restoring a modern, reliable, and open ROS 2 ecosystem for the Panda, this work lowers the barrier to developing safe, responsive, and reproducible human-robot collaboration applications that integrate planning, perception, interaction, and shared autonomy. Code and videos are available on our website at https://sites.google.com/unisa.it/fer-ros2.

0.53

Tread: A Visuo-Inertial Framework for Terrain and Locomotion Context-Aware Gait-Phase and Speed Estimation in Wearable Robotics

cs.RO ·2026-10-13 ·Debadrata Sarkar, Akash Bachhar, Aman Arora
similarity 0.54
Abstract · Supplementary video: A video demonstrating real-time operation of the complete visuo-inertial inference pipeline is available at https://doi…

A wearable assistive robot must continuously estimate terrain, locomotion mode, gait phase, and walking speed. These quantities are commonly addressed by separate, terrain-specific models, with datasets rarely collected under a common protocol. This paper presents a visuo-inertial framework that connects these estimates through a causal pipeline using a chest-mounted camera and four lower-limb inertial measurement units (IMUs). Anticipatory Terrain Perception (ATP) classifies incoming terrain with 96.3% accuracy and anticipates terrain transitions by 1.46 s on average. Terrain-Aware Locomotion Mode Identification (TALMI) achieves 93.7% and 98.8% accuracy for its level-ground and stairs experts respectively, with mean transition latencies being below 200 ms. The relevant TALMI posterior is retained as a Probabilistic Locomotion Context (PLC) vector and provided to a shared Gait Kinematic Encoder (GKE), which supports 50-Hz bilateral gait-phase estimation and 2-Hz walking-speed estimation. Leave-one-subject-out evaluation yields gait-phase RMSEs of 1.75%, 2.97%, and 4.55% for level walking, stair ascent, and stair descent respectively while estimating speed over 3.5-5.5 km/h with a RMSE of 0.218 km/h. All inertial sensing based models use sensor-fused Euler angles as input rather than raw accelerometer and gyroscope signals, reducing dependence on sensor mounting variation.

0.26

Levio: Smart Actuated Back-Exoskeleton via Retrofit of a Commercial Passive Device

cs.RO ·2026-11-17 ·Ionnais Kyriazis, Mohamed Irfan Refai, Herman van der Kooij
similarity 0.54
Abstract

Passive back exoskeletons show promising benefits for reducing occupational musculoskeletal disorders. However, their assistance cannot be modulated towards the task requirements. Active exoskeletons offer opportunities for pose-specific assistance, but, developing these systems from scratch for research can be time consuming. Therefore, here, we present an accelerated design pipeline that retrofits a Commercial Off-The-Shelf (COTS) passive back exoskeleton, Laevo Flex, with COTS actuation (CubeMars AK10-9) and sensing (IMUs and load-cell) paradigms. Levio was able to provide assistance based on the user's pose. Nine participants performed stoop lifting with the original Laevo and the retrofit Levio system, in transparent and assisted modes. Compared to Laevo, Levio modulated the assistance provided between the bending and lifting phases of the stoop task. The passive assistance offered by Laevo was $25.2 \pm 4.3$ Nm and $30.6 \pm 9.5$ Nm respectively during the bending and lifting phases of the stoop tasks. Levio reduced the resistive torque during bending to $17.9 \pm 4.6$ Nm and offered increased assistance of $37.7 \pm 6.4$ Nm during lifting. Moreover, participants reported higher usability scores and lowest mean global discomfort score while using the Levio when compared to Laevo. These benefits demonstrates retrofitting passive exoskeletons is a viable direction for rapid prototyping of wearable exoskeletons for lifting.

0.24