CS Paper Radar

Smartphone-Enabled Depth-Aware Transillumination Imaging for Detection of Chicken Breast Fillet Myopathies in Chicken Fillets

Chaitanya Pallerla, Ramesh Bahadur Bist, Yihong Feng, Yang Tian, Shiva Paudel, Casey M. Owens, Cengiz Koparan, Jeyamkondan Subbiah, Dongyi Wang

cs.LG ·submitted 2026-11-09 18:03 UTC · v1
unusual

Abstract

Woody Breast (WB) myopathy is a major quality defect in broiler chickens characterized by fibrosis, increased tissue hardness, and altered structural properties that affect product quality. Conventional palpation is subjective and labor-intensive, while many non-destructive methods require specialized equipment or substantial computational resources. This study developed a smartphone-based transillumination and 3D point-cloud framework for non-destructive WB severity classification. A total of 267 chicken breast fillets, including normal breast (NB, n = 87), mild WB (MWB, n = 85), and severe WB (SWB, n = 95), were evaluated using RAW transillumination images and 3D point clouds acquired with an iPhone 16 Pro. A total of 91 features, comprising 14 image-derived, 76 geometric, and one physics-informed Beer-Lambert attenuation feature, were extracted. Partial correlation controlling for thickness revealed a significant association between image characteristics and WB severity (r = 0.413, p < 0.0001), indicating optical information independent of fillet geometry. SWB tissue exhibited approximately 26% greater light attenuation per unit thickness than NB. The 2D-only models achieved approximately 82% test accuracy, while the multimodal ensemble combining Fusion-DGCNN, XGBoost, and physics-guided logistic regression (PGLR) achieved approximately 90% accuracy. These findings demonstrate the complementary value of optical, geometric, and physics-informed features and establish the feasibility of smartphone-based, non-destructive WB severity assessment.

Closest papers

Nearest neighbours by meaning across the whole index.

Mobile Imaging Solutions for Medical Diagnosis: Trends and Applications

cs.CV cs.AIcs.LG ·2026-09-21 ·Syed Muhammad Ibne Zulfiker, Fariha Tabassum Islam, Md Sultanul Arifin, Khandker Aftarul Islam, Nishat Anjum Bristy +5 more
survey similarity 0.50
Abstract

Advances in processing power, camera technologies, and mobile image analysis have made smartphones and other mobile devices, such as laptops, increasingly suitable for medical diagnosis and healthcare applications. Researchers have developed low-cost solutions for the early detection and monitoring of various health conditions, including eye and ENT diseases, malnutrition, heart rate variability, skin and oral conditions, and injuries, using images captured by non-medical devices such as smartphones and webcams. This survey examines existing research on mobile image-based medical diagnosis, with an emphasis on its potential to enable low-cost and accessible healthcare. We comparatively analyze state-of-the-art solutions across different healthcare application categories, examining their advantages and limitations. Based on this analysis, we identify desirable characteristics of mobile image-based diagnostic tools and highlight areas where existing approaches have made progress as well as areas requiring further research. We also discuss application-specific and common challenges and outline directions for future research. Overall, this study provides a comprehensive overview of mobile image-based healthcare solutions and their potential to support low-cost disease diagnosis and monitoring, particularly for underserved populations in remote and resource-constrained settings.

0.25

Tracking Ethological Behaviors of Broiler Chickens Through Computer Vision (YoloV11) Using an Android Mobile Device

cs.CV ·2026-11-17 ·Ryan Davi Oliveira de Meneses, Glauber da Rocha Balthazar
published similarity 0.48
Abstract

This study developed and evaluated a computer vision model for automated ethological behavior classification of broiler chickens in climate-controlled poultry houses. Using publicly available videos preprocessed and manually annotated into three classes (sitting, standing, and feeding), the YOLOv11 model was trained and deployed on an Android application via TFLite conversion. Exploratory analysis ensured dataset consistency and visual quality, while evaluation showed class-dependent performance: higher robustness for static postures (sitting, AP=0.531; precision=100%) and lower accuracy for dynamic behaviors (feeding, AP=0.292; recall=0.20). Tests with unseen images demonstrated significant improvements, achieving accuracies of 98.04% for sitting, 83.33% for standing, and 67.65% for feeding. The model showed effective generalization in real farm environments, supporting its potential for continuous behavioral monitoring, early welfare assessments, and decision-making in precision poultry farming. These findings establish a technical foundation for future mobile-based applications at commercial scale, reinforcing the role of computer vision in automated animal welfare evaluation.

0.36

Clinical Feasibility of Low-Magnification Fluorescence Imaging for Breast Cancer Margin Detection Using Texture Analysis and Deep Learning

cs.CV cs.AIcs.LG ·2026-08-11 ·Pouya Afshin, Tianling Niu, Tongtong Lu, David Helminiak, Julie Jorns +4 more
published similarity 0.47
Abstract · This research has been accepted and published in Journal "Biomedical Optics Express" in July 2026 with Manuscript ID is 596807

High-resolution images of unprocessed surgical breast tissue can be obtained using microscopy with ultraviolet surface excitation (MUSE). This technique is considered a promising method for checking surgical margins during breast cancer surgery. In this study, MUSE images at 4x and 10x magnifications were compared using patch-level classification methods. Texture analysis (TA) based on local binary patterns (LBP) and deep learning (DL) with a base Vision Transformer (ViT) model were used. Both methods achieved similar performance at both magnifications. Using DL method, both 4x and 10x magnifications achieved 96.30% sensitivity, 100% specificity and 98.18% accuracy. Using TA method, 4x achieved better specificity (100% vs 93.33%) and 10x yielded higher sensitivity (100% vs 93.33%), but both had the same accuracy (96.67%). No clear improvement in performance was observed with 10x magnification. These results show that 4x imaging achieves the same diagnostic accuracy as 10x imaging. At the same time, 4x offers a larger field of view and faster image capture. Therefore, lower magnification can be effectively used in MUSE systems for accurate and efficient intraoperative margin assessment.

0.28

Reconstructed holograms and explanation-aware evaluation for low-cost computational pollen analysis in veterinary cytology

cs.CV cs.LGq-bio.QM ·2026-09-19 ·Swarn Warshaneyan, Joial Danyal, Blaž Cugmas, Mindaugas Tamošiūnas, Edgars Kviesis-Kipge +2 more
unusual similarity 0.45
Abstract · 25 pages, 17 figures, 20 tables. Supplementary material included. Submitted to a journal for peer review

Automated pollen analysis supports veterinary cytology, but brightfield microscopy is costlier and more complex than lens-less digital in-line holographic microscopy. We evaluate whether reconstructed holograms can narrow this gap and whether model explanations remain reliable under modality change. Six pollen species were imaged by brightfield and holographic microscopy. Raw, single back-propagation and iterative phase retrieval holograms were evaluated with YOLOv26s detection and MobileNetV4 classification after anchor-based annotation transfer. Six attribution methods were assessed for spatial grounding and faithfulness with the Attribution Health Inspection and Repair (AHIR) protocol, which tests model brittleness under weak noise and corrects attribution-map granularity when needed. Brightfield achieved 0.6890 mAP50-95 (0.8865 mAP50) for detection and 0.9687 macro-F1 (0.9705 accuracy) for classification. Reconstructed holograms narrowed the gap with a task-dependent split: p-type was strongest for detection at 0.5324 mAP50-95 (0.8229 mAP50), while r-type was strongest for classification at 0.7695 macro-F1 (0.7866 accuracy), both far above raw-hologram baselines. Activation-based explanations localized strongly on grains, and region-based methods retained ~60 to ~80% of faithfulness under holography. The holographic detector was highly brittle to weak perturbations, saturating deletion-based evaluation while insertion remained informative. Pixel-level gradient explanations approached random floor, yet spatial smoothing restored p-type gradient faithfulness from 0.05 to 0.51. For holographic classification, perturbation-based explanations remained faithful while gradient-based methods fell below random floor. Reconstruction improves low-cost holographic pollen analysis, while AHIR distinguishes genuine attribution failure from artifacts caused by model brittleness and map granularity.

0.34

CAppleNet: A Coordinate Attention-Based YOLO11 for Real-Time Apple Stem Cavity and Calyx Detection

cs.CV cs.AI ·2026-11-10 ·Alican Güneş, Robert Selim Hill, Gökhan Hasanoğlu, Murat Kurt
similarity 0.45
Abstract · 19 pages, 6 figures, 15 tables

Automated fruit grading, sorting, and orientation systems require real-time, accurate detection of fruit-level morphological landmarks rather than the fruit boundary alone. This paper presents a custom, fully self-collected and self-annotated dataset of 1506 apple images (1054 training, 301 validation, 151 test) captured under controlled, fixed-camera conditions and annotated for three target classes: fruit body, stem cavity, and calyx. A YOLO11s detector trained with default hyperparameters is adopted as the baseline, and a systematic, one-factor-at-a-time ablation study is conducted across input resolution, data augmentation policy, optimizer configuration, and lightweight architectural enhancement to identify the factors that most improve detection of these fine-grained landmarks under high inter-cultivar color and texture variability. Neither increased input resolution, nor any of six tested augmentation variants, nor manual optimizer tuning improved on the untuned baseline (F1 = 0.9047); only a same-slot architectural substitution of the backbone's C2PSA block with Coordinate Attention (CA) matched the baseline's overall F1 (0.9038) while reducing parameter count by 10.2% and achieving the study's best mAP@0.5 (0.935) and best stem-cavity F1 (0.8217). A confidence-threshold sweep identified 0.15 as the deployment operating point for this model, and a confirmatory experiment combining the CA-swap architecture with the best-performing augmentation variant showed the two effects do not combine additively, reversing the architectural gain rather than compounding it. The resulting design recommendations --- the CA-swap architecture alone, at a 0.15 confidence threshold --- target real-time apple landmark detection for orientation-aware industrial sorting and alignment systems.

0.20

TACTUS: A Robotic Palpation System for Spatially Heterogeneous Hardness Mapping of Woody Breast Myopathy

cs.LG ·2026-11-09 ·Chaitanya Pallerla, Yihong Feng, Avisekh Tripathy, Yang Tian, Pouya Sohrabipour +4 more
similarity 0.44
Abstract

Woody breast (WB) myopathy is a spatially heterogeneous fibro-degenerative condition of the broiler Pectoralis major muscle. Existing mechanical reference methods rely on single-point or sequential compression measurements, limiting characterization of spatial hardness variability. This study presents TACTUS (Tactile Adaptive Conformal 3D Uniform Sensing), an automated tactile array that generates thickness-normalized, three-dimensional hardness maps at 20 anatomically distributed locations within approximately 30 s. TACTUS integrates 20 independently motorized tactuators with force-sensing resistors and encoder-driven linear actuators, alongside a LiDAR depth camera for surface profiling and adaptive compression. The system was evaluated using 100 broiler breast fillets across four WB severity classes (Normal, Mild, Moderate, Severe). TACTUS identified significant force differences among severity classes (ANOVA, p < 0.001), with the strongest differentiation in the cranial region and a significant caudal effect not detected by texture-analyzer measurements. Fillet-level TACTUS force showed moderate but significant correlation with texture-analyzer measurements (Pearson r = 0.441, p < 0.001). Semivariogram, local change entropy, and heterogeneity analyses revealed increasing and anatomically structured hardness variability with WB severity. These findings demonstrate TACTUS as an automated, operator-independent platform for spatially resolved mechanical characterization and ground-truth generation to support hyperspectral and near-infrared spectroscopy-based WB classification systems.

0.23

An Automated Thickness Evaluation Procedure Using an Integrated Structured Light 3D Camera in a Robotic Bioprinting Framework

cs.RO ·2026-09-10 ·Ehsan Zobeidi, Omid Rezayof, Farshid Alambeigi
published similarity 0.44
Abstract · This paper has been accepted for publication at the 2026 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2026)

Bioprinting is emerging as a tissue engineering technique to replace common treatment methods for large scale injuries. While thickness of the BioPrinted Constructs (BPCs) have shown to be of importance in the cell maturation and integration, the literature lacks a robust, automated, and quantitative method for measuring these metrics. In this paper, we propose a fully automated vision-based method for measuring the thickness of the BPCs with complex geometries. Leveraging the point cloud and RGB images of a structured light 3D camera, our proposed method performs an image-based segmentation for delineating the BPCs from the RGB images, accompanied by novel geometry-based thickness measurement algorithms performed on the point cloud scans. These algorithms combine the segmentation mask with the robot's forward kinematics data and a 3D point cloud scan to precisely measure the aforementioned metrics for complex-shaped BPCs. The proposed method was evaluated in simulation and experimental studies. In simulation studies, the algorithms were used to measure the thickness of some virtually created BPCs with known thickness. The comparison between the measured and true thicknesses demonstrates the high accuracy of the proposed method, achieving mean absolute errors between 0.025 mm and 0.057 mm in simulation at a spatial resolution of 0.1 mm x 0.1 mm per pixel. Furthermore, we successfully deployed the algorithms on our robotic bioprinting setup utilizing a structure light 3D camera, where complex patterns were printed and the developed methods utilized to accurately measure the thickness of printed BPCs.

0.58

A Miniaturized Wi-Fi HaLow-Based Wireless Imaging Transfer System for Capsule Endoscopy

eess.IV ·2026-10-09 ·Michele Bertozzi, Lorenzo Amelio, Sebastiano Strangio, Nikita J. Greenidge, Benjamin Calmé +3 more
similarity 0.43
Abstract

Wireless capsule endoscopy is constrained by severe limitations in size, available power, and reliable data transmission through biological tissues. Although recent advances in miniature imaging sensors have improved image quality, the wireless transmission of color images at practical frame rates remains a challenging task under the tight capsule constraints. We present the design and the experimental validation of a miniaturized Wireless Imaging Transfer (WIT) system for capsule endoscopy based on a sub-GHz IEEE 802.11ah (Wi-Fi HaLow) wireless link. In addition, a preliminary in-vivo validation of Wi-Fi HaLow communication is reported, showing that a stable through-body wireless link can be established across biological tissues in a clinically relevant porcine model. These in-vivo results provide direct experimental support for the adoption of sub-GHz Wi-Fi HaLow for capsule endoscopy applications. Experimental results demonstrate stable wireless image transmission at a resolution of 320x320 pixels, with measured end-to-end data rates above 12 Mbps and a transmission energy efficiency of 20.7 nJ/bit. We also report a detailed power consumption analysis, with a breakdown of the contributions from the imaging sensor, illumination, digital processing, and RF transmission. When all active subsystem contributions are considered, including the camera, digital processing, RF transmission, and illumination at 60% LED brightness, the total power consumption is approximately 477 mW, corresponding to a complete-chain energy consumption of approximately 39.6 nJ/bit. Overall, the measured performance confirms that sub-GHz Wi-Fi HaLow provides a promising trade-off among throughput, robustness, and energy efficiency for wireless imaging in capsule endoscopy.

0.22