CS Paper Radar

ECG-LabWAS: A Laboratory-Wide Association Study Using a Fine-Tuned Single-Lead Electrocardiogram Foundation Model

Wenhui Liu, Yujie Xiao, Gongzheng Tang, Jianwei Chen, Jun Li, Guangkun Nie, Deyun Zhang, Qinghao Zhao, Shenda Hong

eess.SP ·submitted 2026-11-20 07:18 UTC · v1

Abstract

Laboratory testing guides clinical diagnosis but requires blood sampling and processing. The electrocardiogram (ECG) is fast and noninvasive and may carry information about laboratory abnormalities, yet most AI-ECG models target one test at a time using 12-lead recordings. We conducted an exploratory ECG laboratory-wide association study (ECG-LabWAS), fine-tuning an ECG foundation model pretrained on 10.8 million ECGs to screen 50 laboratory tests from single-lead waveforms alone. The model was developed in an emergency-department cohort (MC-MED; 31,826 patients) and applied unchanged to an independent hospital cohort (MIMIC-IV; 115,921 patients). Of 89 abnormality directions (low or high values of each test), 33 met the same screening criteria in both cohorts. Areas under the receiver operating characteristic curve in the two cohorts were 0.841 and 0.838 for elevated NT-proBNP, 0.769 and 0.740 for elevated cardiac troponin, 0.755 and 0.731 for elevated creatinine, and 0.713 and 0.710 for low potassium. Discrimination changed little when the ECG--laboratory matching window was widened from $\pm$1 to $\pm$24 hours. Model predictions reproduced the co-occurrence of observed abnormalities but were about twice as tightly coupled, largely along one shared component consistent with overall illness severity; low potassium, elevated NT-proBNP and troponin, and markers of renal function retained discrimination beyond that of correlated tests. In exploratory analyses, ECG-assisted versions of the modified Glasgow Prognostic Score and the systemic inflammatory response syndrome criteria were associated with in-hospital and one-year mortality. These results identify which laboratory abnormalities warrant analyte-specific study with single-lead ECG.

Closest papers

Nearest neighbours by meaning across the whole index.

Pediatric ECG foundation model via adult-to-pediatric fine-tuning: downstream tasks and clinical evaluation

cs.AI ·2026-11-05 ·Yu Cao, Haiyan Xu, Xiaohan Li, Jian Yang, Yuqing Feng +2 more
similarity 0.68
Abstract · 20 pages,3 figures

Pediatric electrocardiogram (ECG) interpretation is complicated by age-dependent electrophysiological changes that limit direct transfer of adult AI models. We asked whether an adult ECG foundation model could be adapted to pediatric ECGs. Using 339,563 12-lead ECGs from 238,189 children, we compared direct application, pediatric fine-tuning, and training from scratch under an identical architecture. Direct transfer was poor (mean AUC 0.8256). Fine-tuning reached 0.9695, above de novo training (0.9661), and attained 0.9079 using only 1% of training data. On 10,999 external ECGs, fine-tuning achieved a mean AUC of 0.9385 across 30 labels. It generalized to age regression (MAE 1.12 years) and congenital heart disease classification (AUC 0.9562). Across 17 clinicians and 100 cases, diagnostic accuracy rose from 56.8% to 65.4% (p < 0.001) and did not decline when AI erred. Adult ECG foundation models require pediatric adaptation; fine-tuning offers a data-efficient route to scalable pediatric ECG AI.

0.21

ECG for laboratory values:A comprehensive physiological and technical analysis

cs.LG cs.AI ·2026-10-20 ·Walentin Palanchuk
code/data similarity 0.65
Abstract · 78 pages, 17 figures, source code under https://github.com/WPalanchuk/ECG-for-Labvalues

Laboratory measurements are essential for clinical decision making but typically require invasive blood sampling. Recent research suggests that ECG recordings may contain information beyond cardiac rhythm and provide information related to laboratory values. This thesis investigates NT-proBNP prediction from ECG recordings and patient metadata using a multimodal deep learning framework, while considering the physiological plausibility of ECG-based prediction. It also compares a 1-lead configuration using lead II with the corresponding 12-lead configuration. Additional experiments on glucose, hemoglobin, and potassium are presented in the appendix. Regression, binary classification, and three-class classification experiments were conducted using MIMIC-IV, with the three-class task based on clinically established thresholds. The 12-lead configuration consistently achieved better performance. Regression reached a mean absolute error of 534.98 pg/mL for 1-lead and 514.27 pg/mL for 12-lead. Binary classification achieved AUROCs of 0.849 and 0.876, respectively, while three-class classification achieved macro-averaged AUROCs of 0.738 and 0.752. The results indicate that precise NT-proBNP regression remains challenging, whereas broader concentration ranges can be classified more effectively. The findings are consistent with the physiological hypothesis that ECG characteristics and NT-proBNP concentrations reflect shared cardiovascular processes. ECG-based NT-proBNP prediction may therefore provide complementary information, particularly for classifying broader concentration ranges. However, laboratory measurements remain necessary, and validation on independent datasets is required.

0.37

BiMa-ECGSR: reconstructing the 12-lead ECG from reduced lead sets with bidirectional state-space models

cs.LG cs.AI ·2026-11-17 ·Ugo Lomoio, Pierangelo Veltri, Pietro Hiram Guzzi
similarity 0.65
Abstract

Wearables and monitors record few electrocardiogram (ECG) leads; most diagnostic tools assume 12 leads. BiMa-ECGSR reconstructs the 12-lead ECG from reduced lead sets with a bidirectional Mamba state-space encoder--decoder, as regression (BiMa-SR) or diffusion (DiBiMa-SR). Models were trained on PTB-XL for six input sets (I; II; I+II; I+II+V1; I+II+V2; I+II+V1+V4), see only the measured leads at inference, and were tested on the PTB-XL test fold (2,198 records) and two external cohorts (Georgia, 10,275 records; Chapman-Shaoxing/Ningbo, 43,559). From lead II alone, the pooled median Pearson correlation (PCC) over the 11 predicted leads was 0.914 on PTB-XL, against 0.784 for a least-squares linear filter (lead I: 0.906 against 0.789). As limb leads are exactly derivable from I and II, multi-lead inputs were compared on predicted chest leads: 0.939 against 0.849 for I+II and 0.979 against 0.962 for I+II+V1+V4. BiMa-SR exceeded the linear comparator in all 18 configuration--cohort pairs (by 0.012--0.136), a margin that shrank as chest leads were added. From lead II, regression was more accurate than diffusion (DiBiMa-SR: 0.903 one-step, 0.862 with six DDIM steps). A 12-lead classifier trained only on real ECGs reached a superclass macro AUROC of 0.912 on real PTB-XL ECGs, 0.843 on reconstructions from lead II and 0.908 from I+II+V1+V4; externally, reconstructions from three or four leads scored within 0.004 of real ECGs. BiMa-SR (2.68\,M parameters) takes 45.8 ms per 10-s record on a GPU. Reconstruction makes reduced-lead recordings usable by 12-lead tools; it cannot add information absent from the measured leads.

0.38

Beat-Synchronous Tokenization for ECG Transformers

cs.LG eess.SP ·2026-08-31 ·Ahmed Sameh, Nolan Wilson, Max Enderlein, Yogatheesan Varatharajah
published similarity 0.64
Abstract · 6 pages, 1 figure, 3 tables. Accepted at the 2026 IEEE International Workshop on Machine Learning for Signal Processing (MLSP 2026)

Transformer-based electrocardiogram (ECG) models commonly tokenize waveforms into fixed temporal patches. Though convenient, fixed patching can split heartbeat structures across token boundaries. We study beat-synchronous tokenization as a physiologically grounded alternative, comparing fixed patches with three beat-aligned strategies: resampled beats, adaptive pooled beats, and resampled beats augmented with R--R interval information. Experiments span two settings: 10-second 12-lead diagnostic classification on PTB-XL after MIMIC-IV-ECG masked pretraining, and 60-second single-lead rhythm classification on Icentia11k after patient-level contrastive pretraining. On PTB-XL, resampled beat tokens achieve the highest mean macro Area Under the ROC Curve (AUROC; 0.8945) and nearly match the best fixed-patch macro Area Under the Precision-Recall Curve (AUPRC; 0.7414), reducing average sequence length from 100 to 11.2 tokens. On Icentia11k, beat-synchronous tokenizers obtain comparable AUPRC to fixed patching with better stability across runs. These results suggest morphology-preserving beat tokenization is a compact, competitive alternative to fixed temporal patching.

0.21

TIBECG: Temporal Information Bottleneck for Lead-Specific Demographic Privacy in ECG Waveform Release

cs.LG cs.AIcs.CReess.SP ·2026-11-16 ·Tsai-Min Chen, Jun Seita
similarity 0.64
Abstract · 12 pages, 9 figures, 2 tables. Corresponding author: Tsai-Min Chen

Transmitting an electrocardiogram (ECG) waveform can expose demographic information beyond an intended diagnostic task. We evaluate TIBECG, an architectural temporal information bottleneck, on individual leads extracted from hospital twelve-lead recordings. A 2,302,337-parameter processor varies its latent length while retaining the same nine-score consistency objective, without age or sex labels in protector fitting. Across 6,386 recordings, ten folds, 12 leads and 21 lengths, retrospective selections retained at least 95% of each lead's clean macro-F1. Their weaker age/sex interval gain exceeded the best eligible conventional transformation on all leads, by a median 22.08 percentage points. The implemented sampling-rate comparison shows that direct downsampling usually suppresses demographic inference more strongly but at a larger loss of diagnostic utility, whereas TIBECG favors utility preservation. Selection stability also varies by lead. Lower latent Kullback-Leibler (KL) divergence does not reliably rank residual sex leakage at a fixed length. These findings support lead-specific evaluation of waveform processing, not validated consumer deployment or expert-readable reconstruction. When the waveform-input diagnostic classifier is hosted as part of a proprietary cloud service rather than deployed on the device, waveform transmission is required to obtain its scores.

0.37

ECGJev: Question-Conditioned Option Scoring for 12-Lead ECG Interpretation

cs.LG eess.SP ·2026-11-01 ·Zhuoyuan Li, Xidong Wu, Hanyu Cui, Jiansong Gao, Rongrong Fu +2 more
code/datahot direction similarity 0.63
Abstract · 5 pages (4 pages plus ethics statement and references), 2 figures. Submitted to IEEE ISBI 2027. Zhuoyuan Li and Xidong Wu contributed equall…

Clinical interpretation of a 12-lead electrocardiogram (ECG) often requires answering targeted diagnostic questions with clear, quantifiable decisions. We introduce ECGJev, the first ECG framework built on a decision decoder, a pretrained language model trained to return a probability for every listed option. A question-conditioned bridge compresses frozen waveform and spectrogram features into 16 ECG tokens, and a two-stage procedure adapts the bridge and low-rank adapters on the decoder's native option readout using diagnostic labels alone, scoring all options for a question in one forward pass. Evaluated across four ECG benchmarks, ECGJev achieves the highest macro-F1 on CPSC2018 (80.46%), PTB-XL (71.68%) and Chapman (96.86%), and generalizes competitively to the small-sample PTB cohort. Concept probes and perturbation analyses further show that its predictions rely directly on the ECG input, remain stable under option-order and wording variations, and transfer zero-shot to unseen waveform concepts. Our code is available at https://github.com/zhuoyuanli-lab/ECGJev.

0.34

Evaluator-Dependent Patient-Adaptive ECG Lead-Channel Allocation

cs.CV ·2026-08-27 ·Xiaoyang Li, Zeyan Tao
similarity 0.61
Abstract · 17 pages: 5-page main paper and 12-page supplementary material; 6 figures and 16 supplementary tables. Updated figures and supplementary mat…

The diagnostic value of an ECG channel depends on the model that interprets it. We test whether adaptive acquisition retains its advantage over fixed protocols when that model changes. Two policies developed with a logistic evaluator are frozen and assessed with a masked waveform ResNet1D, using exhaustive, metric-matched fixed comparators. On PTB-XL, replacing the evaluator reverses the mean adaptive advantage in negative log-likelihood and Brier score across the tested budgets, while calibration responds less uniformly. The shift persists with common fixed references and broader training-mask exposure. Training a policy against the stronger evaluator partly recovers the lost advantage. These retrospective exploratory results show that acquisition quality cannot be assessed independently of the downstream evaluator and motivate validating adaptive policies with the model intended for diagnosis.

0.26

MS-ECG-FM: Towards a More Universal Electrocardiogram Foundation Model for Health Monitoring using Multi-source Contrastive Learning

cs.LG ·2026-10-06 ·Robert A. Lewis, I-Min Chiu, Kyle Verrier, Karthik Jayaraman Raghuram, Francoise Marvel +5 more
similarity 0.60
Abstract · Andrew C. Miller, Joseph Futoma: equal contribution. 52 pages, 4 figures, 20 tables, including supplementary information

Electrocardiography (ECG) records the electrical activity of the heart, aiding diagnosis by detecting abnormalities in cardiac function. ECG foundation models have demonstrated promising results, but are limited by a reliance on ECG interpretation reports as their sole supervision. Because interpretation reports only capture the subset of waveform information routinely recognized by clinicians, this constrains representation learning to overlook the broader diagnostic signals present in ECG. We introduce a new ECG foundation model --- MS-ECG-FM --- that is trained through contrastive alignment to multiple distinct clinical note types, including ECG, echocardiography, radiology, and discharge reports. We evaluate MS-ECG-FM on an extended set of ECG detection benchmarks, showing that it comprehensively outperforms existing methods on the full span of conditions that ECG can detect, including in reduced-lead configurations. Different reports improve representations for different diagnostic domains, while multi-source alignment captures their complementary information and produces consistently strong representations across clinically diverse tasks.

0.32