CS Paper Radar

DGC-Net: A Depth-Geometric Conditioning Network for Projection-Supervised OCTA Segmentation

Lucas Santiago, Bisheng Wang, Jaime S. Cardoso, Tomás Ribeiro

cs.CV ·submitted 2026-11-20 17:02 UTC · v1
published

Abstract

OCTA segmentation is commonly formulated as a projection supervised task: models observe 3D volumetric scans but are supervised by 2D en-face semantic maps. Existing 2D and 3D-to-2D methods either discard axial information or compress depth responses into latent projections, leaving vessel crossings, diffuse capillary regions, and FAZ boundaries vulnerable to projection-induced ambiguity. We propose DGC-Net, a Depth-Geometric Conditioning Network that recasts 3D-to-2D OCTA segmentation as depth-geometrically conditioned prediction, where projected features are decoded with compact descriptors of axial vascular evidence. DGC-Net preserves local depth geometry through Depth-Moment Conditioning (DM), which injects axial localization and dispersion cues into the projection stream, and captures global depth layout through Holistic Depth-Geometry Modulation (HDM), which derives a raw-volume axial prior for final 2D decoding. Experiments on the OCTA-500 6mm and 3mm subsets show that DGC-Net achieves 83.58% and 88.62% mIoU, respectively, reaching state-of-the-art performance.

Comment
Accepted at WACV 2027

Closest papers

Nearest neighbours by meaning across the whole index.

Vessel2Brain: Edge-Aware Multi-Scale Flow Matching for 3D Brain Image Generation from Vessel Masks

cs.CV ·2026-11-13 ·Zhi Chen, Tianyang Zhang, Theodoros N. Arvanitis, Le Zhang
similarity 0.67
Abstract

Generating realistic 3D brain MRI volumes from sparse anatomical priors is a highly ill-posed yet clinically valuable problem, with important applications in data augmentation, simulation, and downstream neuroimaging analysis. In this work, we investigate the challenging task of synthesising full 3D brain MRI volumes conditioned solely on vascular label maps. While vascular structures provide strong anatomical and topological cues, they occupy only a small fraction of the brain volume and offer no direct information about surrounding tissue appearance. To address this challenge, we propose Vessel2Brain, an edge-aware multi-scale conditional flow matching framework that explicitly incorporates vascular structure information into the generative process. Our approach formulates vessel-guided brain image synthesis as a conditional continuous flow, enabling stable training and flexible generation while preserving structural correspondence. A multi-scale flow matching strategy is introduced to jointly model global anatomical coherence and fine-grained local details, with auxiliary velocity predictions providing additional supervision across spatial resolutions. Furthermore, we design an edge-aware objective that emphasises vascular boundaries during training, encouraging anatomically faithful tissue synthesis around vessel structures. We evaluate Vessel2Brain on two public 3D brain MRI datasets with paired vascular annotations. Extensive quantitative and qualitative experiments demonstrate that our method consistently outperforms state-of-the-art generative models in terms of reconstruction accuracy, structural consistency, and distributional realism.

0.13

PPCAR-Net: Projection-Refined Parametric 3D Coronary Artery Reconstruction from Sparse X-ray Angiographic Views

cs.CV ·2026-10-07 ·Yu Ren, Hwee Kuan Lee, Tat-Jen Cham, Jonathan Yap, Khung Keong Yeo
code/data similarity 0.67
Abstract · 22 pages, 5 figures, 10 tables, including references and appendix. Code and pretrained models: https://github.com/G2304138H/PPCAR-Net . Proj…

Sparse-view 3D coronary reconstruction commonly relies on cross-view correspondence and triangulation, which are vulnerable to vessel overlap and foreshortening, or on volumetric prediction followed by vascular-graph extraction, which does not directly provide centrelines and radii. We introduce PPCAR-Net, a projection-refined parametric coronary artery reconstruction network that directly predicts a branch-structured centreline-and-radius representation without explicit point matching, triangulation, or an intermediate volume. Given a variable number of segmented views, a coarse predictor combines frozen VGGT features with learned branch queries to estimate branch presence, B-spline centreline trajectories, and dense radius profiles. Projection-guided geometry and radius refiners then sample local evidence from the input views and apply residual corrections learned with 3D supervision. We evaluate representation fidelity and sparse-view reconstruction quantitatively and qualitatively. On simulated angiographic masks generated from CT-derived coronary anatomy, PPCAR-Net produces better connected artery reconstructions and achieves strong centreline accuracy, particularly for RCA, while maintaining competitive volumetric overlap. Coarse-to-fine inference takes 121 ms, enabling real-time reconstruction.

0.29

Zero-Shot Brain MRI Inpainting with 2.5D Unconditional Flow Priors

cs.CV ·2026-10-06 ·Arnela Hadzic, Franz Thaler, Simon Johannes Joham, Martin Urschler
code/data similarity 0.67
Abstract

Generative inpainting of brain MRI volumes is essential for synthesizing healthy tissue in pathological regions, improving the accuracy and reliability of automated downstream brain analysis applications such as image registration, brain extraction, and segmentation. However, standard 3D approaches are computationally prohibitive, while efficient 2D slice-wise methods suffer from severe inter-slice discontinuities. Furthermore, traditional models rely on conditional training, requiring task-specific learning of masked inputs. We propose a zero-shot brain MRI inpainting framework utilizing 2.5D unconditional flow priors to capture spatial context along the superior-inferior axis without the overhead of full 3D convolutions. During training, our flow matching model learns the joint distribution of adjacent axial slice triplets, modeling the manifold of healthy brain anatomy while explicitly excluding pathological regions from the loss function. At inference, the model processes the input triplets autoregressively along the depth axis. We employ the Restora-Flow solver to constrain the unconditional prior using the input mask, achieving accurate zero-shot inpainting. Evaluations show our 2.5D strategy resolves the structural discontinuities of 2D baselines, synthesizing plausible healthy tissue while maintaining volumetric consistency across the axial, sagittal, and coronal planes. As a final step, we generate and average an ensemble of multiple stochastic reconstructions to form the final prediction. Quantitative results benchmarked on the official BraTS 2026 Inpainting Challenge validation set demonstrate the effectiveness of our proposed approach, yielding an SSIM of 0.816 $\pm$ 0.112, MSE of 0.007 $\pm$ 0.005, and PSNR of 22.923 $\pm$ 4.343. Code is available at https://github.com/imigraz/brats2026-inpainting.

0.16

Parameter-Efficient 3D Segmentation of Liver and Liver tumors: Depthwise factorization Scales Better Than Dense Convolution with Spatial Dimensionality

cs.CV cs.LG ·2026-09-27 ·Adham M. Alkhadrawi, Mohammed A. B. Mahmoud
benchmark similarity 0.67
Abstract

Three-dimensional dense convolutional networks are the strongest performers on volumetric medical image segmentation, but their parameter counts scale poorly: moving a dense k x k convolution to k x k x k multiplies its weights by k. We observe that depthwise separable factorization does not share this penalty. Because the cubic kernel term applies only to the depthwise stage while the pointwise projection, which dominates the parameter count, is unchanged, the same architecture grows by 5 % from 2D to 3D where a dense convolutional U-Net grows by 200 %. We exploit this asymmetry to build a 3D U-Net with 536,990 parameters, 24x fewer than an identical dense 3D U-Net. On MSD Task03 Liver (the Medical Segmentation Decathlon liver task, derived from LiTS), evaluated per case under five-fold cross-validation over all 131 public volumes, the model reaches a tumor Dice of 0.577 (95% CI [0.518, 0.633]) and a liver Dice of 0.947 (95% CI [0.941, 0.952]). Its liver Dice exceeds previously reported performance. Its tumor Dice exceeds their low-resolution configuration (0.4701) by 0.107 and their 2D configuration (0.5394), at approximately one twenty-fourth of the parameters and roughly half the in-plane resolution. Trained under identical conditions on a common held-out split, it exceeds a dense 3D U-Net on liver by +0.031 Dice (paired p = 0.006) and on tumor by +0.041 (95 % CI [+0.005, +0.081], paired p = 0.056), suggesting the factorization also acts as a regularizer in the small-data regime characteristic of medical imaging. We further show, on both LiTS and a 2D endoscopy benchmark, that a large fraction of the network's learnable spatial filters can be replaced by fixed shifts at no cost in accuracy, but that replacing all of them is measurably worse, the placement of spatial capacity matters more than its total amount.

0.11

Automated 2D and 3D Segmentation of AMD and DME Lesions in OCT

cs.CV ·2026-08-27 ·Lucia Sundberg, Zhihao Zhao, M. Ali Nasseri
similarity 0.66
Abstract

Age-related macular degeneration (AMD) and diabetic macular edema (DME) are leading causes of vision loss, and optical coherence tomography (OCT) is the standard modality for detecting and monitoring the subtle lesions that drive treatment decisions. Most deep-learning segmentation work for OCT is validated only in-domain, leaving generalization to clinical data collected under different acquisition protocols largely untested. This work develops and systematically ablates four lesion-segmentation pipelines -- 2D and 3D variants for AMD and DME -- reaching Dice scores of 0.76 to 0.82 with strong volumetric and surface calibration (r vol, r surf greater than or equal to 0.97 across all four pipelines) on an in-domain validation set. The ablation process establishes a full-volume, calibration-aware adoption standard that catches mechanisms an ordinary slice-level evaluation would keep, and identifies ensemble composition as the most consistent driver of improvement. To test generalization, the models are evaluated on OLIVES, an external clinical cohort with no lesion-level ground truth, using a proxy-metric framework built around biomarker AUROC, central subfield thickness (CST) correlation, and longitudinal concordance. Predictions track clinical biomarkers outside the training distribution, though less strongly than in-domain -- evidence for, not validation of, automated lesion-burden tracking as a clinical tool.

0.25

Steer the Sampling, Not the Kernel Grid: Geometry-Guided Sampling Operator for Volumetric Segmentation

cs.CV ·2026-08-26 ·Sizhe Wang, Himashi Peiris, Zhaolin Chen
top venue similarity 0.66
Abstract · Accepted at MICCAI 2026

Accurate 3D segmentation is central to quantitative lesion assessment and anatomy mapping for clinical planning and follow-up. Thin, elongated, and fine anatomical/pathological structures (e.g., vessels) are a particularly challenging case: a one-voxel boundary error can disconnect a branch and change clinically relevant topology. In encoder-decoder networks (e.g., U-Net), repeated downsampling and fixed-grid convolution blur or alias fine structures and weaken orientation cues, so early mistakes propagate across scales. We propose a geometry-guided local operator that steers where features are sampled, rather than deforming convolutional kernels, under a single formulation for both feature refinement (stride 1) and resolution reduction (stride > 1). At each voxel, it predicts a local orientation and bounded step sizes, samples symmetrically along these directions, and transforms paired samples into compact geometric and boundary cues with lightweight mixing; a cross-scale consensus aligns encoder and decoder features at skip connections to reduce geometric mismatch. Replacing all stride 1 and stride 2 operators in a 3D U-Net yields consistent improvements on BraTS, MSD Hepatic Vessel, and TDSC-ABUS, with notably better boundary metrics (e.g., BraTS Dice 86.1 to 88.9, HD95 7.1 to 6.2; TDSC-ABUS HD95 39.1 to 27.8) while reducing parameters from 2.3M to 0.8M. We further demonstrate that the operator can be integrated into other backbones (e.g., nnU-Net, Swin-UNETR, and MedNeXt) without changing their macro-architectures while providing consistent performance gains.

0.24

Improving Cross-Site Whole-Heart Segmentation

eess.IV cs.CV ·2026-08-25 ·Tanish Mudaliar, Justin Li, Daniel Lin, Julianna Vo, Kaitao Liao +2 more
publishedcode/data similarity 0.65
Abstract · 12 pages, 2 figures. Accepted to the MICCAI 2026 for the CARE Whole Heart Segmentation Challenge proceedings

Whole-heart segmentation from CT and MRI is essential for quantitative cardiac image analysis, but remains challenging under multi-center and multi-modality distribution shift. In the CARE whole-heart segmentation task, models must generalize from limited labeled sites to unseen acquisition distributions, where variation in spacing, intensity, reconstruction texture, and anatomy can degrade out-of-distribution performance. We propose a modality-routed 3D cardiac segmentation pipeline that combines TotalSegmentator-initialized nnU-Netv2 models with site-characterized, label-preserving appearance augmentation. We first characterize the available sites using measurable image properties and use this analysis to motivate candidate data-space generalization routes. The final retained recipe applies Bias Field + Bezier appearance augmentation, combining smooth spatial intensity perturbation with nonlinear intensity remapping, followed by lightweight class-wise largest-connected-component cleanup. On the primary held-out-site validation splits, the final configuration improves CT mean Dice from 0.8350 to 0.9135 and MRI mean Dice from 0.7695 to 0.7830, while also reducing HD95. These results suggest that site-motivated appearance augmentation is a practical strategy for improving cross-site robustness in limited-data whole-heart segmentation. Our code can be found in https://github.com/Purdue-M2/Improving-Cross-Site-Whole-Heart-Segmentation

0.51

Inference-Time Orthogonal Seeding Enables Geometry-Aligned 3D Organ Segmentation for Slice-Propagation Methods

cs.CV ·2026-08-12 ·Md Rakibul Haque, Tushar Kataria, Shireen Y. Elhabian
published similarity 0.65
Abstract · 8 Pages Accepted at MLMI Workshop MICCAI 2026

Dense voxel-level annotation remains a major bottleneck in 3D medical image segmentation. Single-slice propagation methods such as Sli2Vol reduce this burden by propagating one annotated seed slice through a volume using label-free registration. However, axial-only propagation accumulates errors with distance from the seed, especially in surface-distance metrics, because it ignores coronal and sagittal evidence and therefore underuses the 3D information available in CT/MRI volumes. To better leverage volumetric geometry, we study how key training and inference choices affect slice-propagation models, including single-axis versus multi-axis label-free registration, single-seed versus multi-seed propagation, and orthogonal seed configurations. Instead of propagating from a single axial seed, we use three orthogonal seeds---one axial, one coronal, and one sagittal---and fuse their propagated labels with a simple label-free rule. Our results show that the training paradigm has limited impact: an axially trained network applied to off-axis seeds captures nearly all the improvement, while explicit three-axis training adds little. Instead, performance is driven by inference-time seed geometry, especially orthogonality rather than the number of annotated slices, as a budget-matched three-axial control provides no benefit and can even degrade performance. On a multi-organ CT cohort, orthogonal seeding with the axial Sli2Vol backbone improves Dice by 21.9%, Normalized Surface Dice by 25.5%, and reduces Average Hausdorff Distance by 53.5% over the single-axis baseline.

0.54