CS Paper Radar

Advanced Reactance Method - A Novel Approach for Distance Protection in Presence of Grid-Following Inverter-Based-Resources

Jonathan Loebel, Jannik Polster, Johann Jaeger

eess.SY ·submitted 2026-11-21 14:27 UTC · v1

Abstract

Renewable Energy Sources and consequently inverter-based resources (IBRs) are increasing worldwide. Grid-following (GFL) IBR control is the state-of-the-art. GFL IBRs exhibit different fault behavior compared to classical synchronous generators -- particularly in terms of Fault-Ride-Through (FRT) characteristics, which are critical for grid protection relaying. Grid protection must work securely, selectively and dependably, regardless of the feeding source. As common protection algorithms are designed for fault behavior determined by synchronous generators, their performance is expected to be compromised in the presence of GFL IBRs. Distance Protection is a widely used protection algorithm at all voltage levels. Literature shows that the FRT behavior of GFL IBRs impacts the Distance Protection relaying adversely. This paper proposes the Advanced Reactance Method, a further development of the Classical Reactance Method for Distance Protection in the presence of GFL IBRs. The key idea of the proposed method is to make the algorithm independent of the feeding source impedance. Therefore, the negative sequence voltage is taken into account along with the negative sequence current. This makes the algorithm independent of the FRT behavior of GFL IBRs, even in case of suppression of negative sequence current during unsymmetrical faults. Moreover, correct settings for the classical method in the presence of GFL IBRs are presented as a solution for relays without the advanced method. The novel algorithm is evaluated against the correctly parameterized Classical Reactance Method and the Distance Protection algorithm.

Closest papers

Nearest neighbours by meaning across the whole index.

Power-Swing Blocking Scheme Based on Continuous and Higher-Order Incremental Quantities for Systems with Inverter-Based Resources

eess.SY ·2026-11-05 ·Henrik Johansson, Qianli Xing, Nathaniel Taylor, Xiongfei Wang
similarity 0.69
Abstract · 9 pages, 11 figures

Conventional power-swing blocking (PSB) schemes for distance protection face new and emerging challenges as the penetration levels of inverter-based resources (IBRs) increase. Several papers highlight interoperability issues concerning faster power swings and unconventional impedance trajectories. Revised relay settings are proposed in attempts to deal with the problems. However, the blinder-based PSB methodology suffers from being dependent on the speed of the apparent impedance trajectory over the tiny region between the blinders, making it difficult to distinguish between fast swings and faults. Moreover, blinders have the inherent limitation that they cannot operate if the measured impedance is inside the blinders when the fault is cleared and immediately enters the distance zones during the first swing cycle - an issue often overlooked in the current literature. This paper proposes a novel PSB scheme based on higher-order incremental quantities (IQs) for difficult swing scenarios with IBRs and synchronous generators (SGs). PSCAD/EMTDC simulations of an SG and an implemented grid-forming (GFM) inverter validate its superior performance compared to conventional dual-blinder PSB schemes. The impacts of GFM inverters on the impedance measured by distance relays during the fault-to-swing transition and first power swing cycle are also discussed.

0.39

Protection challenges and solutions on power systems towards 100% inverter-based resources and energy storage systems

eess.SY ·2026-11-02 ·Alexander Novikov, Luis A. Garcia-Reyes, Anup Joshi, Ahmar Farooque, Junaid Khalid +1 more
published similarity 0.67
Abstract · Danmarks Tekniske Universitetet, Katholieke Universiteit Leuven, Department of Electrical Engineering, Electrical Energy Computer Architectu…

The decarbonization of the energy sector, driven by the Paris Agreement and the European Green Deal, is increasing the share of renewable energy sources (RES) in power systems. Unlike traditional systems, RES-based systems rely on power electronic converters, which creates unprecedented challenges for reliability and resilience. The future power system is expected to combine a low-level AC layer with an upper-level High Voltage Direct Current (HVDC) backbone, which requires new understanding of fault protection, stability, and interaction between AC and DC components, as well as new models and simulation tools. This is especially critical in systems moving towards 100 percent converter-based generation. Protection systems detect, locate, and isolate faults to protect assets while the rest of the system keeps operating. Traditionally, they rely on the large fault currents supplied by synchronous machines. In modern systems, converter controls limit the fault current contribution to about 120 percent of rated current, so relays that distinguish faults from normal overcurrents based on current level may operate incorrectly. In addition, inverter-based resources (IBR) may not inject enough negative and zero sequence current for directional relays to work properly, and converters hold the voltage at a fixed value only within their reach, beyond which it drops quickly. As a result, existing protection schemes may not provide the expected accuracy and reliability. This report reviews the protection challenges identified in recent academic literature for power systems with high shares of converter-based resources. It covers the specific characteristics of RES, the challenges for protection with intelligent electronic devices (IED), the challenges of converter control during faults, and the main solutions proposed in research over the last decade.

0.49

Power-Swing Blocking and Out-of-Step Tripping Scheme Using the Swing Center Voltage in Systems With Inverter-Based Resources

eess.SY ·2026-11-23 ·Henrik Johansson, Qianli Xing, Jaekeun Lee, Ki-Hyun Kim, Nathaniel Taylor +1 more
similarity 0.64
Abstract · 10 pages, 13 figures

Misoperation of power-swing blocking (PSB) and out-of-step tripping (OST) schemes in distance relays is a critical concern in power systems with increasing penetration levels of inverter-based resources (IBRs). Recently, several papers have studied the impact of IBRs on conventional dual-blinder PSB/OST schemes. They highlight interoperability issues concerning fast power swings and unconventional impedance trajectories, and propose revised relay settings in attempts to deal with the problems. However, the blinder-based PSB methodology suffers from being dependent on the speed of the apparent impedance just as it crosses between the blinders. It is therefore important to consider alternative methods. This paper thoroughly analyzes the characteristics of the swing center voltage (SCV) and the impacts of grid-forming (GFM) and grid-following (GFL) inverters on its local estimation. Then, an SCV-based PSB/OST scheme is proposed, where the main PSB criterion can be tuned from simple system parameters. This is made possible by a separate PSB activation function. The OST scheme uses only one setting and is motivated from the analytical analysis of the SCV with IBRs. Extensive PSCAD/EMTDC simulations verify the performance of the proposed SCV-based PSB/OST scheme and how it overcomes limitations of blinder-based schemes with GFM and GFL inverters.

0.11

The Race between Protection and Control: Fast Reactive Reserves Against Overvoltage Cascade

eess.SY ·2026-11-14 ·Abdallah Alalem Albustami, Mads Almassalkhi, Ahmad F. Taha
similarity 0.56
Abstract

In an overvoltage cascade, each relay trip removes reactive power absorption and raises the voltage at other plants, often faster than controls can act. This paper determines how much fast reactive power to hold, where, and how fast, so that no contingency trips a plant. A trip certificate allows a relay to pick up if it resets before its delay expires, making the sizing a linear program. A necessary condition identifies the relays that only preventive action can protect, and the reserve of one control decreases with the relay delay and increases with its latency. In nonlinear simulations of four systems, the corrective actions prevent every trip within the analysis window for relays without reset hysteresis, and each plant's own set point is the most effective reserve. A 2\% hysteresis or a small error in the relay voltage can change the reserve as much as the relay delay.

0.24

Causal Discovery for Resiliency-Prioritized Transmission Expansion Planning in Power Systems with Grid-Forming Inverter-Based Resources

eess.SY ·2026-11-15 ·Roy McCann, Mustafa Mhawesh, Sandra Canas Rivera
benchmark similarity 0.55
Abstract

Transmission planners at regional transmission organizations (RTOs), independent system operators (ISOs), and NERC-registered entities have limited analytical resources for exploring expansion options that improve resiliency for withstanding and recovering from fault conditions in electric power systems that are dominated by grid-forming (GFM) and grid-following (GFL) inverter-based resources (IBRs). Conventional existing TPL-001 contingency analysis will assess if a performance benchmark is violated. However, it will not identify which dynamic states and inputs caused the violation, nor how much a protective action will avoid propagation into a cascading outage. This paper proposes an analytical method that combines time-series causal discovery using the Peter and Clark Momentary Conditional Independence (PCMCI) algorithm with right/left eigenvector participation-factor analysis of validated small-signal state-space models. Synthetic data are generated from linearized models derived from substation phasor measurement unit (PMU) data. This includes node-breaker topologies under alternative transmission switching configurations. GFM and GFL inverter controls including phase-locked loops (PLLs) and fault ride-through logic. A planning index referred to as the Resiliency Causal Contribution Index (RCCI) is defined that weights PCMCI-derived causal effects on a TPL benchmark quantity by modal participation. The planning procedure iterates contingency categories, measures margins to RTO/ISO benchmarks for transient voltage recovery, oscillatory damping, inverter ride-through, and TPL-008-1 extreme temperature. The process infers automatic protective actions and repeats until a cascade is ruled out or confirmed. A simplified case study illustrates the entire process for considering the options in transmission expansion planning.

0.33

Report on Stability Analysis of Islanded Power Systems with Grid-Forming Converters

eess.SY ·2026-10-30 ·Anup Joshi, Luis A. Garcia-Reyes, Qingyuan Gong, Xavier Guillaud, Javier Renedo +1 more
published similarity 0.54
Abstract · Danmarks Tekniske Universitetet, Katholieke Universiteit Leuven, Department of Electrical Engineering, Electrical Energy Computer Architectu…

Islanded power systems are inherently challenging to operate due to limited interconnection, low inertia, and weak short-circuit strength. As renewable and inverter-based resources replace synchronous machines, these challenges worsen, causing faster frequency deviations, greater voltage volatility, and higher risk of instability. This report summarizes the differences between islanded and interconnected systems and reviews key stability issues in islanded grids: frequency stability, converter-driven interactions, voltage stability, large-disturbance behavior, and small-signal dynamics. Grid-forming (GFM) voltage source converters are a promising solution because they can establish voltage and frequency, emulate synchronous machine behavior, and provide grid strength, virtual inertia, fast frequency response, voltage regulation, and black-start capability. The report examines relevant GFM control strategies and evaluates their capabilities in weak, low-inertia islanded grids. Challenges remain, particularly interoperability, control coordination among multiple inverter-based resources, lack of standardized grid code requirements, and coordination of protection devices. Successful deployment requires advances in interoperability, harmonized grid codes, and grid planning that considers the unique features of islanded systems, along with clear GFM functionality requirements. Finally, a case study illustrates the stability-enhancing capability of GFM converters in weak grids through small-signal stability analysis. Overall, GFM technology is a key enabler of reliable, renewable-dominant island power systems, but broader adoption depends on continued technical and regulatory development.

0.36

Safe Barrier Function Control for Grid-Following Inverters under Weak Grid Conditions

eess.SY ·2026-10-18 ·Grigoris Michos, Christos K. Verginis
similarity 0.54
Abstract · 10 pages

This paper proposes a barrier control approach for the safe regulation of grid-following voltage-source-converters (VSC), operating in weak grid conditions. The proposed controller aims to enhance the transient performance and synchronization properties of the VSC, providing frequency and current limiting guarantees by employing smooth control barrier functions. First, a dynamic model is derived that includes the dynamic state interactions that are omitted in quasi-steady-state approaches, revealing the destabilizing elements both during transient and steady-state performance. Then, it is analytically proven that the proposed control law guarantees frequency limitation and inner current evolution in prescribed safety regions, while counteracting the destabilizing strong coupling between PCC voltage and injected current. In addition, sufficient conditions are formulated that guarantee the stability of the closed-loop system with respect to desired operating points. The theoretic results are verified in simulations of case studies operating in varying grid strength.

0.32

Local Energy Function-Based Power System Transient Stability Analysis with Grid Forming and Grid Following Inverters

eess.SY ·2026-09-06 ·Yingyi Tang, Junbo Zhao, Baosen Zhang
similarity 0.54
Abstract

The widespread deployment of inverter-based resources (IBRs) is reshaping power system dynamics by their control strategies. Grid-following (GFL) and grid-forming (GFM) inverters are expected to co-exist from now on. However, ensuring the transient stability of such systems remains a critical and underexplored challenge. In this paper, a comprehensive transient stability analysis of the mixed-GFM-GFL inverter system is conducted using a newly derived local energy function. The transient stability analysis model of the system is first derived to reveal the dynamic interactions between GFL and GFM inverters during transient responses. A local energy function is then proposed for analytical transient stability assessment. Instead of ignoring or making harsh assumptions on inverters' coupled damping effect, the proposed local energy function carefully addresses its impact on system transient stability by locally bounding the region where the system's energy dissipation property holds. Such a property fully considers the combined damping effect of GFL and GFM inverters. The derived critical energy and stability index provide a fast and quantitative transient stability assessment. Furthermore, the adverse impact of insufficient damping of GFM inverters on system transient stability is thoroughly investigated. The effectiveness of the proposed method is validated on the modified IEEE 14-bus system with mixed GFL and GFM inverters, and the numerical simulation results further demonstrate the small conservativeness of the proposed method.

0.24