CS Paper Radar

Connected but Late: Sample Age of Commercial BLE Wearables under Wi-Fi Coexistence for Real-Time Clinical Applications

Monica Perez-Serrano, Hümay Zehra Özer, Seung Ju Paek, Diego Paez-Granados

cs.NI ·submitted 2026-11-23 14:41 UTC · v1

Abstract

Wearable sensors are increasingly being used in real-time clinical applications, such as rehabilitation robots and live therapy monitoring. As Healthcare 5.0 moves towards personalized therapies, their use will continue growing, potentially compromising communication reliability. Most wearables transmit over Bluetooth Low Energy, sharing 2.4 GHz with institutional Wi-Fi. Previous coexistence studies have focused on whether data arrive, rather than when. We measured sample age for a commercial electrocardiogram strap, from acquisition through the gateway to storage in our platform MEDWEAR, in an anechoic chamber and a hospital rehabilitation gym, and we compared it with illustrative clinical deadlines. Without load, the strap's own framing was the largest source of delay, making samples on average 280 ms and up to 550 ms old before transmission. Wi-Fi load had no measurable effect while adaptive frequency hopping could avoid the loaded channel. In a stress test, which forced the link onto the loaded channel, the link became the dominant source of delay, adding up to 11 s. The link stayed connected, but a median of 29% of samples and up to 98% (worst case) were older than 1 s on arrival at the gateway. The gym behaved mostly like the quiet chamber, but during one traffic burst, while hopping was restricted, up to 4.6% of samples were older than 1 s. These results show that a connected link can deliver late data. Therefore, sensors intended for real-time clinical applications should be profiled in situ and monitored based on sample age rather than connection status alone.

Closest papers

Nearest neighbours by meaning across the whole index.

Protocol-Flexible Custom NFC for Wire-Free Wearable Sensor Networks

cs.NI ·2026-09-20 ·Riku Maeda, Akihito Noda
publishedunusual similarity 0.57
Abstract · 4 pages, 5 figures, 1 table. Accepted manuscript; accepted for publication in IEEE Sensors Letters

This study presents a custom near-field communication (NFC) system with software-defined protocol implementation for wearable sensors distributed across the body. Conventional wired implementations can degrade wearability because of mechanical constraints, whereas radio-based wireless approaches such as Bluetooth are affected by body-induced signal attenuation and limited communication coverage. The proposed system is compatible with previously demonstrated fabric-integrated meander coils, which provides a feasible path toward garment-scale NFC communication areas. The system combines a microcontroller unit with compact modulation and demodulation circuits, allowing medium access control and other communication protocols to be implemented in software. Experimental results demonstrate continuous acquisition of three-axis acceleration data from three sensor tags, achieving a per-tag polling rate of $222\,\mathrm{Hz}$ and an effective throughput of approximately $16\,\mathrm{kbps}$, delivering $156$ valid samples per second per tag at a measured packet error rate of $30\%$.

0.64

Analytical Modeling of Latency and Energy Trade-offs in FiRa-Like BLE-UWB Ranging and Localization Systems

cs.NI ·2026-10-24 ·Adelina Giurea, Jorg Wieme, Ben Van Herbruggen, Jeroen Hoebeke, Eli De Poorter
similarity 0.56
Abstract · submitted to IEEE Transactions on Mobile Computing

Accurate position and distance information provided by Ultra-Wideband (UWB) can enhance a wide range of applications. However, its receive-mode power consumption makes continuous channel monitoring impractical for energy-constrained devices. Consequently, UWB systems often rely on Bluetooth Low Energy (BLE) to discover peers and establish sessions before ranging begins. Although both technologies have been studied in isolation, an framework capturing the latency and energy consumption of the complete workflow is still lacking. To address this gap, we develop a unified analytical model for BLE-assisted UWB systems, from device-to-device ranging to infrastructure-based localization. The model includes closed-form expressions for discovery, parameter exchange, and ranging, and evaluates the resulting latency and energy consumption. Evaluation of three representative BLE configurations shows that the scanner consumes 28-57x more energy per discovery than the advertiser. In addition, the 99th-percentile discovery latency is 2-3.4x higher than the mean and reaches up to 110 s in the lowest-power configuration. The one-time BLE setup overhead is amortized after 24-562 ranging rounds, depending on the discovery configuration. Overall, the analysis demonstrates that the BLE discovery phase can dominate both the latency and the energy budget during short UWB interactions, making discovery configuration as important as the ranging scheme.

0.25

Multi-Sensor Fusion for False-Alarm Reduction by Timed Electromechanical Corroboration

eess.SP physics.med-ph ·2026-11-21 ·Zixuan Fu, Anthony Raffaele, Unnikrishna Pillai
similarity 0.55
Abstract · 8 pages, 8 figures, 3 tables. Submitted to IEEE Journal of Biomedical and Health Informatics

A physician checks the clinical electrocardiogram against other observations. A wearable monitor has no physician. This paper shows that a mechanical sensor worn beside the electrocardiogram can take over that check, and that the right added sensors lower false alarms further. A beat is accepted only when a mechanical contraction follows at the delay learned for the wearer. Beat-shaped artifacts injected into resting and exercise recordings passed the electrocardiogram alone almost every time. A seismocardiogram or phonocardiogram as the second channel rejected most while keeping nearly all true beats, strongly at rest and partly during exercise. Shifting the mechanical signal in time removed the benefit. A detection criterion scores an added sensor by the part of its response that the sensors in place cannot predict. With four sensors, this score ranked the sets as their measured false-alarm rates did. With the two sensors it selected, 6.2 percent of the artifacts passed while 95 percent of true beats were kept, half the rate of the best single sensor. In integer arithmetic on a low-cost microcontroller, the detector made the same decisions as the software. These rates come from injected artifacts, not alarms in patients. Natural motion and clinical events remain untested.

0.42

An Energy Efficient Wearable for Monitoring Elderly People Health

eess.SP cs.CY ·2026-08-26 ·M. Much, A Moraes Filho, J. Sieg, F. Hessel, A. Cataldo Neto +1 more
similarity 0.55
Abstract · 8 pages, 11 figures

The aged population is exposed to risk situations, like falls, sudden changes in vital signs, and faints. These situations become common at this life stage due to a decrease in body capacity and illnesses increase. This scenario imposes attention on families and the national health system. Some studies propose to overcome this problem through elderly health monitoring systems based on smartphones, smartwatches, and other equipment that usually cover low-efficient communication systems and low battery life. This paper proposes an efficient health monitoring system based on Sigfox IoT service and a watch-type wearable device for sensing elderly motion, location, and vital signs to predict risk situations designed to achieve at least 30-days of battery life. Our experimental results show that this architecture is a low-cost, low-power, efficient, and feasible elderly health monitoring solution.

0.36

Leveraging Fast Healthcare Interoperability Resources (FHIR) for the Exchange of Wearable Inertial Sensor Data: Design and Development Study

cs.CY cs.DBcs.LG ·2026-11-23 ·Gabriela Ciortuz, Joshua Wiedekopf, Hannes Ulrich, Hawzhin Hozhabr Pour, Sebastian Fudickar
survey similarity 0.53
Abstract

Continuous monitoring with wearables can support the assessment of frailty, functional decline, and movement disorders, but raw inertial measurement unit (IMU) recordings are typically stored in proprietary files that electronic health records cannot exchange or interpret. HL7 Fast Healthcare Interoperability Resources (FHIR) standardizes health data exchange, yet existing FHIR profiles for personal health devices target spot measurements and short waveforms, not long multichannel motion recordings with their recording context and activity labels. We present WHIR (Wearable Health Interoperable Recordings), a FHIR R5-based information model and implementation guide for wearable IMU recordings. Metadata requirements were derived from a review of 23 published human activity recognition datasets and formalized in a FHIR-independent information model, which was then mapped to FHIR R5 and authored in FHIR Shorthand. Raw signals are kept in files referenced through DocumentReference resources, so that FHIR holds the metadata and activity labels. Terminology reuses SNOMED CT, LOINC, and ISO/IEEE 11073 concepts wherever available. The implementation guide defines 9 profiles, 4 extensions, 10 code systems, and 15 value sets; all artifacts and 67 example instances passed the conformance checks of the HL7 FHIR IG Publisher without errors. Two use cases, machine learning training data and automated home-based geriatric assessment, were implemented as conformant example instances, and we compare the model with the HL7 Personal Health Device Implementation Guide. WHIR provides a FHIR R5-conformant representation of wearable IMU recordings together with device metadata, sensor placement, and time-aligned activity labels, covering concepts that the Personal Health Device Implementation Guide does not address. The implementation guide and its sources are openly available for reuse and extension.

0.29

Physiological Information Reliability: Cross-Layer Adaptive Resource Allocation for Cardiovascular Sensing

eess.SP cs.LGcs.NI ·2026-08-31 ·Navaneeth Krishnan Kamalakannan, Janakiraman Kamalakannan, Harinisri Velmurugan
code/data similarity 0.52
Abstract · 6 pages, 4 figures, 3 tables. Submitted to the Machine Learning for Health (ML4H) 2026 Symposium, Findings Track. Code and experimental arti…

Cardiovascular sensing systems must preserve clinically useful information despite signal degradation, wireless losses, energy constraints, and edge-computation latency. We introduce Physiological Information Reliability (PIR), a cross-layer framework that represents physiological information value jointly with wireless, energy, and computation states and uses a contextual bandit to adapt sensing and communication decisions. We integrate multimodal ECG/PPG signal-quality estimation with physiological information value and an adaptive network-coding layer under burst-erasure conditions. Across controlled multiseed experiments, PIR-LinUCB demonstrates a promising low-energy operating point while maintaining medical latency constraints and competitive physiological estimation performance relative to fixed and heuristic policies. We analyze the resulting accuracy-energy-latency trade-offs and identify limitations of proxy PIV estimation and simulated communication dynamics. These results provide an initial computational demonstration of physiological-information-aware resource allocation and motivate future clinical and real-channel validation.

0.30

Personalized health coaching via coachable health age and counterfactual wearable trajectories

cs.LG q-bio.QM ·2026-11-05 ·Simon A. Lee, Zeinab Esmaeilpour, Menglian Zhou, Marius Guerard, Sohrab Sidhu +15 more
similarity 0.51
Abstract

Personalized health coaching requires moving beyond retrospective wearable summaries toward quantitative, actionable behavioral prescriptions. We introduce Coachable Health Age (CHA), an interpretable health-age metric built from modifiable physiological and behavioral signals passively captured by consumer wearables. Across the WEAR-ME (N=2,780), All of Us (N=22,748), and longitudinal Fitbit (N=1,464) cohorts, CHA aligns with established cardiometabolic health constructs and improves prognostic discrimination for incident cardiovascular and metabolic disease beyond age, sex, and body mass index. To enable prospective behavioral optimization, we developed Sensor World Model (SensorWM), an action-conditioned wearable world model pretrained on over 2.2 million person-weeks of longitudinal sensor data from approximately 100,000 participants. SensorWM accurately forecasts multi-week physiological responses to candidate lifestyle changes ($R^2=0.664$), outperforming generic time-series foundation models while preserving downstream clinical signal for diabetes, hypertension, and other health outcomes. Finally, we integrate CHA and SensorWM into an agentic counterfactual coaching system to synthesize personalized 12-week coaching plans. In blinded paired reviews, certified lifestyle coaches preferred counterfactual-grounded plans over plans grounded in wearable history alone for overall quality (71.4%, P < 0.001) and anticipated adherence (71.0%, P < 0.001), and board-certified clinicians judged 99.2% of counterfactual-grounded plans to meet clinical safety criteria (vs. 97.6% of comparison plans). Automated evaluations across the full cohort (N=2,780) also favored counterfactual-grounded plans. By closing the loop between longitudinal tracking, trajectory prediction, and counterfactual coaching, our framework provides a scalable path to systematically improve cardiometabolic health.

0.14

Demo: Matter-Based IoMT Telemetry and Security Analysis

cs.AR cs.ETcs.RO ·2026-11-12 ·Muhammad Hassan, Masooda Bashir, Carl Gunter
similarity 0.50
Abstract

Connected health devices increasingly support health monitoring outside clinical settings, making secure and accessible physiological data important for patients and caregivers. However, device-specific applications and interfaces complicate the integration of readings from different devices. The Matter standard provides standardized device commissioning and protected communication, but its cluster library does not represent the health attribute measurement. We present a preliminary demo study of a Matter-based IoMT testbed with a specific HealthVitals cluster. Implemented in the connectedhomeip SDK on a Raspberry~Pi~5, the cluster exposes simulated heart rate, blood oxygen saturation, and body temperature. We examine commissioning, attribute retrieval, communication under simulated packet loss, and operational traffic through a reference controller. The study demonstrates that this custom telemetry model can operate within the tested Matter configuration without modifying commissioning or secure-session mechanisms. The resulting testbed gives researchers and device developers a concrete platform for investigating health-oriented extensions. It also supports exploration of local telemetry integration that could help patients and caregivers access readings across connected devices.

0.23