CS Paper Radar

Daily listing

2026-10-19 · eess.SY

25 papers first submitted this day (UTC) in eess.SY — Systems and Control. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Robotics, Control & Signals 18

Fast Reassessment of Prolonged Electricity Shortages under Shared Fuel Interruptions

eess.SY ·2026-10-19 ·Dogan Urgun
code/data
Abstract · 11 pages, 4 figures, 5 tables. Submitted to IEEE Transactions on Reliability. Code and data: https://github.com/DoganUrgun/Fast_Reassessment…

When several generators share a fuel supply, one interruption can disable them together and cause electricity shortages lasting days. Such interruptions can be made less frequent, for example by weatherizing gas supply, or shorter, for example by on-site backup fuel. Yet traditional resource adequacy indices, expected unserved energy and loss-of-load hours, fail to distinguish such measures whenever they remove the same expected time without fuel, because for interruptions independent of system conditions these indices depend on the interruptions only through this time. Their difference is revealed by prolonged-shortage exposure, the expected annual hours in shortages of at least a given duration, whose exact chronological calculation must be repeated for every interruption scenario. To reduce this cost, a fast reassessment method with guaranteed accuracy is proposed. Network calculations are performed once and condensed into a restoration response, the additional prolonged-shortage hours caused by one interruption of each duration, from which any scenario is evaluated as a weighted sum without new simulation. An hour-by-hour error bound determines whether this evaluation is accurate enough, and exact dynamic programming is applied otherwise, so that every result lies within a requested tolerance of the exact value on the same Monte Carlo samples. On the Reliability Test System of the Grid Modernization Laboratory Consortium, most evaluations were accepted, fully accepted scenarios typically ran more than 200 times faster than exact calculation, and total computation time decreased in every workload. Measures against fuel interruptions can thus be screened quickly and accurately by their effect on prolonged shortages.

0.37

Who Breathes the Detour? A Coupled Traffic-Emission-Dispersion-Exposure Pipeline

eess.SY ·2026-10-19 ·Cédric-Yséry Zeiter, Kevin Riehl, Anastasios Kouvelas
code/data
Abstract

Road traffic is among the largest sources of health-damaging air pollution in inhabited areas. Direct measurement of resident exposure at the scale of an entire corridor remains costly, and existing simulation approaches often target either high-fidelity local snapshots or regional averages, leaving the corridor scale underserved. We present a coupled, end-to-end pipeline that links four stages: (i) microscopic traffic simulation with SUMO, (ii) per-vehicle emissions from the HBEFA4 model, (iii) deterministic three-dimensional Eulerian diffusion solved with an implicit finite-difference scheme on a geometric vertical grid, and (iv) resident-level exposure expressed as an air quality index over a synthetic population. The design deliberately trades the fidelity of full CFD dispersion for a workflow that runs end-to-end for the residential areas of several settlements on a single laptop, and the complete implementation is released open source. We showcase the pipeline at the example of the Swiss Gotthard transit corridor, covering the residential areas of six villages, two days, four scenarios, and three pollutants, to enable assessment of congestion mitigation measures. Code & Material: https://github.com/cedriczeiter/zeiter_coupled_pipeline.

0.35

Every minute counts: Wind farm power control during imbalance settlement using distributional soft actor-critic

eess.SY ·2026-10-19 ·Max Bruninx, Seyed Soroush Karimi Madahi, Timothy Verstraeten, Jan Decuyper, Chris Develder +2 more
Abstract

Wind farms can provide flexibility by curtailing their output during periods of excess generation in the power grid. This can be done through implicit balancing, where the power setpoints of the farm are adapted to anticipate the imbalance price. By doing so, the wind farm helps reduce the resulting system imbalance while also lowering its own costs. However, implicit balancing is challenging since the imbalance prices are unknown in advance and hard to predict. Furthermore, the control strategy of the wind farm can affect the imbalance price formation. To address both challenges, we develop a control policy with 1-minute setpoints using distributional soft actor-critic. Evaluated on real data of the Belgian grid and an offshore wind farm, we show that our method outperforms a price threshold controller, often used in industry, by 88% and performs on par with soft actor-critic. Furthermore, unlike soft actor-critic, our approach can learn a risk-averse policy by optimizing a risk measure, such as conditional value at risk. The risk-averse policy was found to better account for its own impact on the price, showing a reduction in overshoots, while achieving a similar degree of imbalance cost savings. Last, we find that using 1-minute instead of 15-minute setpoints further reduces imbalance costs for all evaluated control policies.

0.32

Beyond Observability: Sharp Sample Bounds for Minimax State Reconstruction

eess.SY ·2026-10-19 ·Jerzy Baranowski
Abstract · Submitted to the International Journal of Control. 6 figures

We study how many output samples match the worst-case state reconstruction error obtainable from a continuous history under bounded measurement noise. For observable scalar-output linear time-varying systems with $n$ states, $n$ samples suffice for exact reconstruction, whereas at most $n^2$ attain the continuous-history minimax error in the $\ell_\infty$ norm. An explicit construction proves sharpness even for real-analytic systems. For time-invariant systems, strict total positivity yields one $n$-sample schedule optimal for every state coordinate; endpoint-observed tridiagonal cooperative chains satisfy this conclusion in physical coordinates. Interior sensing behaves differently: an explicit three-state family requires four samples despite positivity and distinct real eigenvalues. The strict three-state gap persists under small stabilizing damping. A nilpotent four-state example and an interval proof for a six-state mechanical system give gaps. The results identify how temporal sampling and the prescribed state-error geometry determine the measurements required for minimax reconstruction. Time-domain experiments illustrate the resulting estimation bounds.

0.28

The Exact Boundary of Linear Optimality in Witsenhausen's Counterexample

eess.SY math.OC ·2026-10-19 ·Yikai Lu, Tongxin Li
Abstract · 39 pages

Witsenhausen's counterexample has resisted a closed form solution for decades. However, it has remained unknown whether a mathematically tractable representation exists or not. In this paper, we solve this open problem, showing that the optimal policies are either linear or not tame and characterizing the exact regions where the two properties hold. Moreover, in the linear optimal region, we give an essentially unique closed form solution for the optimal policy, and show that no optimal first-stage policy is definable in any $o$-minimal expansion of the ordered real field in the nonlinear optimal region.

0.27

Reassessing Clean Power 2030 Pathway Using Real Time Records

eess.SY ·2026-10-19 ·Anthony D Stephens, David R Walwyn
Abstract · 18 pages, 8 tables, 5 figures

The National Energy System Operator (NESO) Clean Power 2030 advice to the government, accepted as United Kingdom (UK) government policy in December 2024, outlines a rapid increase in wind and solar generation capacities with the associated infrastructure by 2030, with the objective of reducing carbon dioxide emissions from the UK electricity system to 5.2 million tons per annum. Our previous paper used real-time records from 2017 to analyze Clean Power 2030 proposal. This paper extends the previous assessment, using real time records of 2017, 2018 and 2019 to test the resilience of the UK energy system under more diverse weather patterns. Two different modelling methods predict that the 2030 carbon dioxide emissions will be five times greater than Clean Power 2030 prediction. Furthermore, the projections show that, due to increased curtailment, only about half of NESO proposed increases in wind and solar capacities will be economically justified. NESO also advised the government that 35GW of unabated gas-fired generation would maintain security of supply, whereas our models suggest that at least 42 GW will be required during winter wind lulls. Recent events, such as grid stability problems in 2026, also discussed in the paper, validate our estimated and suggest the risk of blackouts in the UK is increasing.

0.27

Dynamic Line Ratings Counteract Transmission Investment Needs Driven by Climate Change

eess.SY ·2026-10-19 ·Megan Jones, Vladimir Dvorkin, Michael Craig
Abstract · 16 pages, 7 figures, supplementary information included, under review at Energy & Environmental Science

Rising temperatures due to climate change will reduce power system transmission capacity. This reduction will interact with an ongoing shift from static to time-varying transmission rating standards. Previous research has yet to disentangle the effects of changing rating standards and climates on investment decisions. We quantify transmission investment needs for the Western U.S. power system (WECC) through mid-century under climate change and three rating standards: static ratings (SLR), ambient-adjusted ratings (AAR), and dynamic line ratings (DLR). By embedding alternative rating standards and high-resolution future weather data into a generation and transmission expansion model, PyPSA-USA, we find WECC will lose 1-3% of its transmission capacity across potential future climates under static ratings by mid-century, necessitating a 1-5% increase in transmission investment. Adoption of AAR or DLR eliminates most (81-99%) of the adaptation-driven transmission capacity needs, and further reduces aggregate transmission investments (by up to 31%). Additionally, we demonstrate that planning with time-varying ratings does not increase investment variability for individual lines under climate uncertainty relative to planning with static ratings. Our results emphasize the value and practicality of considering alternative rating standards in climate adaptation planning.

0.26

Exact model reduction by Lie symmetry groups

eess.SY ·2026-10-19 ·Hamed Taghavian, Jens Sjölund
Abstract

We develop a model-reduction technique based on Lie group theory for general engineering models described by a system of algebraic, ordinary, and/or partial differential equations with an arbitrary number of inputs, outputs, and constant parameters. The proposed method reduces the parameter space of these models without changing their external behavior, that is, their input-output maps. We apply this method to phase-field models used for high-fidelity simulations in electrochemistry to accelerate the analysis and design of metal-ion batteries.

0.24

Motion Planning with Temporal Logic Precedence Specifications in Dynamic Environments via Spacetime Augmented Graphs of Convex Sets

eess.SY ·2026-10-19 ·Shilin You, Lars Lindemann, Tyler H. Summers
Abstract

We extend the augmented graph of convex sets GCS framework for motion planning with temporal logic precedence specifications to dynamic environments in which obstacles, keys, and doors undergo piecewise-linear translation and/or dilation over time. The main insight is that piecewise-linear motion of polytopic sets in R^d lifts exactly to a static polytopic partition of spacetime R^d X R_>=0. We show that the main result from the static case carries over to spacetime essentially without modification: a shortest path in the spacetime augmented GCS provides an exact optimal solution to the motion planning problem with precedence specifications. Moreover, the layered subgraph lattice that encodes signal temporal logic (STL) precedence specifications retains precise correspondence with the Bellman--Held--Karp (BHK) algorithm, and the full library of restricted but expressive STL specifications generalizes to the dynamic setting. Further, the framework allows time-gated keys and doors, collectible or passable only within a temporal window. The geometric side of the framework requires two modifications: a causality constraint (the time coordinate of a trajectory must be non-decreasing) and a spacetime speed constraint (bounded physical velocity), both of which are convex in the Bézier control points.

0.23

Optimizing Airport Electric Ground Support Fleets with Digital-Twin-Guided Predictive Control

eess.SY ·2026-10-19 ·Juan Pablo Bertucci, Mauro Salazar, Theo Hofman
Abstract

Electrifying airport ground operations is a key step toward reducing aviation-related emissions, but it makes task assignment and charging coordination strongly coupled in real time. This paper develops a digital twin of airport ground handling operations for electric ground-support vehicles (EGSVs), combining an agent-based model of airport operations with live flight-schedule updates and vehicle-energy dynamics. On this platform, we compare three control strategies for EGSV dispatching and charging: a rule-based heuristic, a rolling-horizon model predictive controller (MPC), and a Monte Carlo tree search (MCTS) controller. The controllers are evaluated on three representative Schiphol Airport operating days and for multiple fleet sizes. The results show a clear trade-off between delays and energy use. Across all tested scenarios, MCTS yields the lowest average flight delay, with a pooled delay of 4.09 min, improving on the heuristic and MPC controllers by 64.7\% and 31.5\%, but at an increased energy consumption of 1\% and 0.3\%, respectively.The MPC and MCTS controllers coordinate charging more effectively throughout the day and reduce the peak charging infrastructure required by 6.0 and 4.7 charger units, respectively. Additionally, we find more vehicles can result in lower overall energy consumption and lower charging infrastructure requirements for all controllers. These findings highlight the value of digital twins not only as offline design evaluation tools, but also as practical environments for real-time control policies in electrified airport operations.

0.23

Adaptive Long-range UAV Flight Planning using Monte Carlo Search Trees

eess.SY ·2026-10-19 ·Chi Keng Dong, Justin Kernot, Dominic Liao-McPherson
published
Abstract · Authors' accepted manuscript. Published in AIAA, DOI: 10.2514/1.G010042

Long-range fixed-wing UAV missions require energy-efficient, dynamically feasible trajectories that can adapt online to evolving wind and airspace constraints. We present a Monte Carlo Tree Search (MCTS)-based framework that addresses this challenge by formulating mission planning as a finite-horizon Markov decision process incorporating aircraft kinematics, onboard energy dynamics, forecast wind fields, terrain, and time-varying no-fly zones. The MCTS planner searches over waypoint references generated by pre-stabilizing feedback controllers and a constraint-aware navigation field, yielding dynamically feasible trajectories. Simulation results from medical delivery scenarios show that the MCTS planner outperforms baseline geometric planners and population-based optimization algorithms. Moreover, the MCTS planner can be used in closed-loop to rapidly compute safe diversion trajectories under evolving constraints.

0.22

Data Center Oscillation Isolation and Grid Support: Fundamental Limits and Source-Selective Control

eess.SY math.DS ·2026-10-19 ·Cheng Feng
Abstract

The grid integration of large data centers poses a growing power-system stability challenge. Rapidly varying computing demand can induce oscillations, while the facilities must provide a prescribed response to grid disturbances. Existing controls address load fluctuations and grid support but do not establish their jointly achievable performance. This paper derives fundamental limits and develops a source-selective controller for simultaneous oscillation isolation and grid support. A coupled closed-loop model gives a condition for distinguishing disturbance sources and reveals a direct isolation-support conflict under grid-import-power feedback alone; additional electrical measurements can remove this pointwise conflict but leave a conditional cross-frequency sensitivity limit. Guided by these limits, we design a local residual-feedback storage controller through convex frequency-domain optimization with stability, isolation, and grid-response constraints across operating points. Tests on a single-generator interconnection and a modified nine-bus network show stronger oscillation isolation than equal-order optimized comparators while meeting the prescribed grid response across operating points.

0.22

Design and Control of a Multimodal Legged-Aerial Robot Through Separate Control Contraction Metrics

cs.RO eess.SY ·2026-10-19 ·Kaushik Venkatesh Krishnamurthy, Eric Sihite, Alireza Ramezani, Morteza Gharib
published
Abstract · Presented at 2026 IEEE International Conference on Intelligent Robots and Systems, Pittsburgh PA

The integration of dynamic legged locomotion and aerial mobility offers versatility that is deterred by challenges in payload distribution, actuation, and the contrasting requirements of both domains. In this paper, we present the design and operation of a multimodal quadrupedal aerial-legged robot. The presence of legged aerial systems also allows for thruster-assisted legged locomotion, which we make possible with a unified control framework using Control Contraction Metrics (CCM). We search for separate domain-specific contraction metrics for walking and flight independently offline and unify them using an online energy-based Control Lyapunov Function Quadratic Program (CLF QP). This enables optimal, cross-domain control allocation, which we show using simulations. We also show experimental results that validate the mechanical viability of our hardware and the paradigm of thruster-assisted trotting. The stability of said experiments motivates the deployment of the control framework for multimodal operations.

0.20

Convex Inner Approximations for Safe AC Dispatch With Device Dynamics

eess.SY ·2026-10-19 ·Ziqing Zhu
Abstract

Safe AC dispatch requires both feasible operating points and enough ramping capability to reach the next target. This paper constructs convex inner approximations that connect nonlinear network feasibility, constrained device response, and dispatch-interval tracking. A fixed-point certificate enforces AC operating limits under bounded load uncertainty. Componentwise response envelopes convert heterogeneous device dynamics into affine conditions on measured states and power references. A command governor then combines these conditions with available ramping capability and a hard terminal-error bound. It selects an admissible target through a minimum-deviation objective and holds the corresponding reference while reserved fast regulation remains active. The resulting quadratic program optimizes controllable references and auxiliary variables. Tests on the IEEE 39- and 118-bus systems include 96 single-target executions and 64 transitions in continuous dispatch sequences at five- and fifteen-minute intervals. All 160 transitions satisfy the AC constraints, independent balancing-generator capability checks, and the prescribed regulation-adjusted terminal accuracy. Complete admission-cycle medians are 3.45 and 8.79 ms. A connected synthetic system with 3,200 buses and 1,000 generating units extends the computational assessment to 999 independent references, with a median cycle time of \LargeMedian{} s. The construction provides a tractable link between available ramping capability and safe, timely execution of AC dispatch.

0.19

PhyPro-FM: A Physics and Prompt-Guided Graph Foundation Model for Contingency Analysis

eess.SY cs.AIcs.LG ·2026-10-19 ·Xu Yang, Zhanyuan Sheng, Chenhui Lin, Haotian Liu, Qi Wang +2 more
Abstract

The continuous evolution of next-generation power systems, characterized by the high penetration of renewable energy resources and dynamic topology variations, poses formidable challenges to traditional N-1/N-2 contingency analysis in terms of computational efficiency and scalability. While deep learning-based methods offer accelerated inference, existing studies predominantly treat contingency analysis as a pure regression problem, often overlooking the physical essence of grid operation and engineering requirements of real-world scenarios. To bridge this gap, this paper proposes a physics and prompt-guided graph foundation model (PhyPro-FM) for generalizable and engineering-viable contingency analysis. The proposed architecture integrates graph neural networks with a learnable global query mechanism and, notably, introduces a prompt-guided learning paradigm. By leveraging historical snapshots as few-shot prompts, the model dynamically captures correlations between target and historical operating conditions, significantly enhancing generalization capabilities under unseen topologies. Furthermore, we design a physics-informed training mechanism that prioritizes branch power flow errors over nodal voltage errors, aligning the optimization objective with critical grid security constraints. To ensure engineering applicability, a physics-informed inference mechanism is also developed, incorporating a residual-based correction module and a specialized post-processing strategy for singular branches to circumvent numerical instability. Comprehensive experiments demonstrate that PhyPro-FM outperforms state-of-the-art methods in accuracy and generalization, validating its superior physical consistency and robustness for practical engineering applications.

0.18

Decentralized Stability Certificates for Interoperability in Power-Electronics-Dominated Power Systems

eess.SY ·2026-10-19 ·Linbin Huang, Verena Häberle, Ruohan Leng, Huanhai Xin, Hua Geng +2 more
Abstract

The rapid integration of power electronics converters has fundamentally altered the power grid's dynamic landscape, making modularity of operation and interoperability of heterogeneous devices two critical hurdles for power system reliability. In control language, these challenges can be paraphrased as decentralized certificates on the input/output behavior of every device, assured by local control, so that stability and guaranteed performance of the interconnected system emerge. For the power system application, such certificates should eventually be part of the rule book, the so-called grid code, and thus be generic and minimally restrictive for the control architecture of each device. Classical system-theoretic angles of attack to these questions go back to dissipativity concepts, which have historically been co-developed in automatic control, circuit theory, and power systems. Since standard dissipativity (e.g., passivity or small gain) criteria fall short in terms of conservatism, a range of more flexible and advanced tools have been developed to assure less conservative decentralized certificates guaranteeing stability under interconnection as well as dynamic performance following a disturbance. In this article, we review a range of methods that have been put forward to tackle these questions, compare and validate them, and point towards practically relevant research gaps which are amenable to control-theoretic approaches. Moreover, we provide a tutorial exposition of practically relevant power systems/electronics issues accessible to control engineers.

0.17

Timing Skew Estimation of Time-Interleaved ADC based on Inter-Channel Correlations without Computing Derivative of Input Signal

eess.SP eess.SY ·2026-10-19 ·Bibhu Datta Sahoo, Gabriele Manganaro
Abstract

Time-interleaved analog-to-digital converters (TI-ADCs) enable multi-gigasample-per-second throughput in high-speed applications, but sub-picosecond timing skews among interleaved channels introduce large spectral artifacts that degrade dynamic performance. To continuously track parametric drifts without interrupting normal operation, background calibration is required. However, extracting timing skews under unknown inputs is challenging, and many existing correlation-based methods rely on resource-heavy derivative filters that restrict input bandwidth. This article proposes a novel background timing-skew estimation technique for two-channel TI-ADCs that overcomes these limitations. Closed-form timing-skew expressions are derived using: (a) adjacent-channel cross-correlation combined with single-channel auto-correlation for sinusoidal inputs, and (b) adjacent-channel cross-correlation for Wide-Sense Stationary (WSS) inputs, specifically bandpass-filtered wideband noise and Orthogonal Frequency Division Multiplexed (OFDM) signals. The derived analytical models are validated through comprehensive simulations, offering an efficient framework for real-time background calibration in high-speed data converters.

0.17

System Identification for Nonlinear Stochastic State-Space Models Using Ensemble Kalman Inversion with Application to Lithium-Ion Batteries

eess.SY ·2026-10-19 ·Farzaneh Barat, Rachel Carter, Sara Wilson, Huijeong Kim, Xinfan Lin +1 more
Abstract · 16 pages, 8 figures, 3 tables

Nonlinear state-space system identification has attracted decades of interest, yet remains challenging because of the interplay among unknown parameters, nonlinear dynamics, and latent state variables. Its difficulty increases dramatically when the state and parameter dimensions increase. To address this challenge, we develop an ensemble Kalman inversion (EnKI)-based approach. This approach leverages EnKI to perform maximum a posteriori parameter estimation through successive local Gaussian approximations, enabling an iterative and incremental search for unknown parameters. The search combines Monte Carlo sampling with Kalman-type updates to evolve an ensemble of parameter samples, thereby offering empirical stability and the ability to handle strongly nonlinear models. The EnKI search is coupled with state estimation conditioned on the latest parameter estimates. This enables parameter identification along with latent state recovery. To improve scalability for large datasets, we further develop a cascaded EnKI (CasEnKI) method, which assimilates subdatasets sequentially to accelerate computation. We validate the proposed methods using a lithium-ion battery model with ten state variables and 18 unknown parameters. Simulation results show that the EnKI approach offers high identification accuracy and empirical stability in parameter search. Further, experimental results illustrate the computational efficiency and scalability of the CasEnKI method for large battery datasets.

0.12